PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 MANUAL INSTRUCTION

Similar documents
80i-110s AC/DC CURRENT PROBE

TT-SI 9001 / TT-SI MHz Active Differential Probes

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

TT-SI MHz Active Differential Probe

TT-SI MHz DIFFERENTIAL PROBE

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TT-SI MHz Active Differential Probe

User Manual Current Probe Instruction Manual

AC FLEXIBLE CURRENT PROBE CA 3000

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

MD 200A High voltage differential probe

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

User Manual Digital Clamp Multimeter. model no.: MSR-C600

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

80i-110s. AC/DC Current Probe Instructions. Introduction

NOTE: Fully read and understand this manual before using this Digital Multimeter.

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Agilent 1146A AC/DC Oscilloscope Current Probe

FlexProbe FLEXIBLE AC CURRENT PROBE. User Manual. FlexProbe ON OL 1000V CAT III 300A 3000A OFF

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

UT207A/208A/209A Operating Manual. Table of Contents

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

DM-46 Instruction Manual

AC/DC CLAMP METER USER S MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, this instruction manual is the description about t

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, the product specification is about the function, u

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Digital Clamp Meter Model: &

User s Guide. Digital AC/DC Clamp Meter Model 38394

400Amp True RMS AC Clamp Meter + NCV

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

AC/DC Current Probes Model MR411 Model MR521

200Amp AC Clamp Meter + NCV Model MA250

LH240 LH1040 LH2040 LH2015

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

CONTENTS MS2033A. 1.Introduction Safety Information...01

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

USER'S MANUAL DMR-6700

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Table of Contents Title Page

MR461 MR561 AC/DC OSCILLOSCOPE CURRENT PROBES. User Manual. AC/DC CURRENT PROBE Model MR 561. AC/DC CURRENT PROBE Model MR V CAT III - 600A

Model : OPERATING MANUAL Table of Contents (1)

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

User Manual Digital Multimeter. model no.: MSR-U1000

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

600A Clamp Meters w/tightsight Display

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro

MW3105 DIGITAL CLAMP MULTIMETER

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

ET-3888 True RMS Clamp Meter. User Manual

10.00 (1/2) PAC series

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

Model UT201/202: OPERATING MANUAL. Table of Contents

Operator s Manual. PP016 Passive Probe

KMD-S04 Multímetro de bolsillo

Multifunction Digital

Not for Reproduction

CT238A. AC/DC Current Probe. User Manual. For detailed specifications and ordering info go to

DM-46 Instruction Manual

MS2030 CAT III 600 V A V AUTO RS232

HHMA2 DC / TRUE RMS AC NON-CONTACT MILLIAMMETER

400Amp True RMS AC/DC Clamp Meter Model EX613

AMM-1022 Digital Multimeter USER`S MANUAL

BENNING. CM7 Electrical Tester. Service Information

RIGOL. User s Guide. RP1003C/RP1004C/RP1005C Current Probe. Mar RIGOL Technologies, Inc

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

Model 7000 Low Noise Differential Preamplifier

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

Advanced Test Equipment Rentals ATEC (2832)

TETRIS User's Guide. High Impedance Active Probe DO177-1

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

AC/DC Current Oscilloscope Probe Model SL261

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Model UT20B: OPERATING MANUAL Table of Contents (1)

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Model UT233 OPERATING MANUAL

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

600 AAC Clamp Meter Instruction Manual

DMM8900 SERIES USERS MANUAL

TABLE OF CONTENTS 1: INTRODUCTION

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Operator s Manual. PP022 Passive Probe

DVM1190 DIGITAL MULTIMETER

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

TA MHz oscilloscope probe TA MHz oscilloscope probe

Transcription:

PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 INSTRUCTION MANUAL

General Safety Instructions: Read the following safety instructions to avoid injury and prevent damage to this product or any products connected to it. Use this product only as specified. Only qualified personnel should perform service procedures. To Avoid Fire or Personal Injury Connect and Disconnect Properly Properly. Connect the probe output to the measurement instrument before connecting the probe to the circuit under test. Disconnect the probe input and the probe ground from the circuit under test before disconnecting the probe from the measurement instrument. Observe All Terminal Ratings Ratings. To avoid fire or shock hazard, observe all rating and markings on the product. Consult the instruction manual for further ratings information before making connections to the product. Replace Batteries Properly type and rating specified. Do Not Operate Without Covers the covers or panels. Avoid Exposed Circuitry Properly. Replace batteries only with the proper Covers. Do not operate this product without Circuitry. Do not touch exposed connections and components when power is present. Do Not Operate With Suspected Failures Failures. If you suspect there is damage to this product, have it inspected by qualified service personnel. Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry.

Safety Terms and Symbols: Terms in This Manual. These terms may appear in this manual: WARNING. WARNING. Warning statements identify conditions or practices that could result in injury or loss of life. CAUTION. CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property. Terms on the Product. These terms may appear on the product: DANGER DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION CAUTION indicates a hazard to property including the product. Symbols on the Product. These symbols may appear on the product: Attention refer to operation Instructions. This instrument has double insulation.

Getting Started: The current probe enables a general purpose oscilloscope to display AC and DC current signals up to 500 amps Peak (180 A RMS). The current probe can also make AC and DC measurements with a multimeter by using the recommended accessory MT-246N (BNC-to-banana) plug adapter. PIC 1 Output Into Press Button Battery Cover Test Position Max. 11 Wire DC Zero Offset Range Selection (Power On/Off)

Shows the controls and indicators on the current probe. Control/Indicator Description Current flow symbol. The arrow shows the probe s polarity convention for measuring current flowing from positive to negative. Zero adjustment. Rotate to adjust the probe output to zero when there is no current present. It may also be used to offset a DC signal component. Zeroing is not needed for AC measurements unless your instrument cannot isolate a DC component (if present). OFF/Range switch. Slide the switch from OFF to either the 10 mv/a or 100mV/A range. When either range is selected, the probe is turned on, and the green battery indicator lights. If the indicator does not light, see Battery Notes and Battery Installation on page11. Battery indicator. The green battery indicator lights when the probe is turned on. For more information, see Battery Notes and Battery Installation on page11. Overload indicator. The red overload indicator lights if the measured signal is greater than the selected range capacity. Switch the probe to 10 mv/a if possible, or remove the probe from the circuit. PT-2710 Basic Operation: Before using the probe, the batteries must be installed. WARNING! Do not clamp the probe onto circuits with voltages greater than 600 VAC. Personal injury or damage to the probe may result. Always connect the PT2710 current probe output to the instrument before clamping onto the circuit under test.

1. First connect the current probe BNC connector to BP-250 (double BNC connection cable) then connect to oscilloscope input. Start by setting the oscilloscope voltage input channel to DC volts, and the voltage sensitivity scale to 5m V/div. 2. Move the OFF/ Range switch to the 5 mv/a or 50 mv/a position to turn on the probe. ( The PT-2710 current probe has a green LED power/battery indicator. If the LED does not light, replace the battery or use specified power adaptor.) 3. Use the ZERO adjustment to zero or offset the probe output detection of residual magnetic DC charges. 4. Connect the probe to the circuit by opening the jaws and clamping around the conductor. See Figure 2. NOTE. Clamping around both the hot hot and neutral wires may give you a zero reading. (Remember to unclamp the probe from the conductor before disconnecting it from your meter or instrument). 5. Adjust the probe channel and oscilloscope s time base as necessary to get a clear and stable view of the signal. Set the oscilloscope input to DC volts to see both the AC and DC currents; set the channel to AC to see the AC current only. The current drawn by different devices look much different than that of others. While the RMS current can only be used in low frequency current, the momentary peaks may be quite high. Figure 3 shows the difference between the line current drawn by a resistive load and a motor controller. Congratulations on your purchase of the PT-2710, a multifunctional current probe. When connecting to a digital meter, use the recommended MT-246N (BNC-to-banana adapter). Connect the black lead to the meter COM (black letters on the meter), and the red lead to the VΩ input (red letters on the meter). To measure only AC current, set the meter to measure AC volts. To measure DC current, set the meter to measure DC volts. Note the current convention arrow on the probe to get the proper polarity reading. To increase the measurement sensitivity of the PT-2710 current probe, loop additional turns of the wire under test through the jaws. See Figure 4. The sensitivity of the PT-2710 current probe is multiplied times the number of loops in the jaws. For example: 50mV/A X5turns=250mV/A

Electrical Characteristics Current Range 5mV/A ; 50mV/A ±2% ±50 ma at 50mV/A DC Accuracy, typical (50mA to 10 A peak range) ±2% ± 1A at 5mV/A (1A to 60 A peak range) Current 60A Frequency Range DC to 100KHz (-3 db) Rise time,typical 2.5uS Noise(Max) 2mV pk-pk Battery 9Vbattery Voltage and current ratings Maximum working current(a) Maximum floating Rating Rating Range Range Maximum floating 5mV/A 50mV/A 測定 DC 50 5 600 600 DC + peak AC 50 5 600 600 AC peak 50 5 600 600 AC peak-peak 100 10 1200 - RMS CAT III 35.4 3.54 600 600 RMS 35.4 3.54 600 600 RMS CAT I 35.4 3.54 600 600 CAT II

PT-2720 Basic Operation: Before using the probe, the batteries must be installed. WARNING! Do not clamp the probe onto circuits with voltages greater than 600 VAC. Personal injury or damage to the probe may result. Always connect the PT2720 current probe output to the instrument before clamping onto the circuit under test. 1. First connect the current probe BNC connector to BP-250 (double BNC connection cable) then connect to oscilloscope input. Start by setting the oscilloscope voltage input channel to DC volts, and the voltage sensitivity scale to 2m V/div. 2. Move the OFF/ Range switch to the 2 mv/a or 20 mv/a position to turn on the probe. ( The PT-2710 current probe has a green LED power/battery indicator. If the LED does not light, replace the battery or use specified power adaptor.) 3. Use the ZERO adjustment to zero or offset the probe output detection of residual magnetic DC charges. 4. Connect the probe to the circuit by opening the jaws and clamping around the conductor. See Figure 2. NOTE. Clamping around both the hot hot and neutral wires may give you a zero reading. (Remember to unclamp the probe from the conductor before disconnecting it from your meter or instrument). 5. Adjust the probe channel and oscilloscope s time base as necessary to get a clear and stable view of the signal. Set the oscilloscope input to DC volts to see both the AC and DC currents; set the channel to AC to see the AC current only. The current drawn by different devices look much different than that of others. While the RMS current can only be used in low frequency current, the momentary peaks may be quite high. Figure 3 shows the difference between the line current drawn by a resistive load and a motor controller. Congratulations on your purchase of the PT-2720, a multifunctional current probe. When connecting to a digital meter, use the recommended MT-246N (BNC-to-banana adapter). Connect the black lead to the meter COM (black letters on the meter), and the red lead to the VΩ input (red letters on the meter). To measure only AC current, set the meter to measure AC volts.

To measure DC current, set the meter to measure DC volts. Note the current convention arrow on the probe to get the proper polarity reading. To increase the measurement sensitivity of the PT-2720 current probe, loop additional turns of the wire under test through the jaws. See Figure 4. The sensitivity of the PT-2720 current probe is multiplied times the number of loops in the jaws. For example: 20mV/A X5turns=100mV/A Electrical Characteristics Current Range 2mV/A ; 20mV/A ±2% ±50 ma at 20mV/A DC Accuracy, typical (50mA to 10 A peak range) ±2% ± 1A at 2mV/A (1A to 200 A peak range) Current 200A Frequency Range DC to 150KHz (-3 db) Rise time,typical 2.3uS Noise(Max) 2mV pk-pk Battery 9Vbattery Voltage and current ratings Maximum working current(a) Maximum floating Rating Rating Range 5mV/A Range 50mV/A Maximum floating DC 測定 50 5 600 600 DC + peak 50 5 600 600 AC AC peak 50 5 600 600

AC peak-peak 100 10 1200 - RMS CAT III 35.4 3.54 600 600 RMS 35.4 3.54 600 600 RMS CAT I 35.4 3.54 600 600 CAT II PT-2740 Basic Operation: Before using the probe, the batteries must be installed. WARNING! Do not clamp the probe onto circuits with voltages greater than 600 VAC. Personal injury or damage to the probe may result. Always connect the PT2740 current probe output to the instrument before clamping onto the circuit under test. 1. First connect the current probe BNC connector to BP-250 (double BNC connection cable) then connect to oscilloscope input. Start by setting the oscilloscope voltage input channel to DC volts, and the voltage sensitivity scale to 2m V/div. 2. Move the OFF/ Range switch to the 2 mv/a or 20 mv/a position to turn on the probe. ( The PT-2740 current probe has a green LED power/battery indicator. If the LED does not light, replace the battery or use specified power adaptor.) 3. Use the ZERO adjustment to zero or offset the probe output detection of residual magnetic DC charges. 4. Connect the probe to the circuit by opening the jaws and clamping around the conductor. See Figure 2. NOTE. Clamping around both the hot hot and neutral wires may give you a zero reading. (Remember to unclamp the probe from the conductor before disconnecting it from your meter or instrument). 5. Adjust the probe channel and oscilloscope s time base as necessary to get a clear and stable view of the signal. Set the oscilloscope input to DC volts to see both the AC and DC currents; set the channel to AC to see the AC current only. The current drawn by different devices look much different than that of others. While the RMS current can only be used in low frequency current, the momentary peaks may be quite high. Figure 3 shows the difference between the line current drawn by a resistive load and a motor controller.

Congratulations on your purchase of the PT-2740, a multifunctional current probe. When connecting to a digital meter, use the recommended MT-246N (BNC-to-banana adapter). Connect the black lead to the meter COM (black letters on the meter), and the red lead to the VΩ input (red letters on the meter). To measure only AC current, set the meter to measure AC volts. To measure DC current, set the meter to measure DC volts. Note the current convention arrow on the probe to get the proper polarity reading. To increase the measurement sensitivity of the PT-2740 current probe, loop additional turns of the wire under test through the jaws. See Figure 4. The sensitivity of the PT-2740 current probe is multiplied times the number of loops in the jaws. For example: 20mV/A X5turns=100mV/A Electrical Characteristics Current Range 2mV/A ; 20mV/A ±2% ±50 ma at 20mV/A DC Accuracy, typical (50mA to 60 A peak range) ±2% ± 1A at 2mV/A (1A to 500 A peak range) Current 500A Frequency Range DC to 150KHz (-3 db) Rise time,typical 2.3uS Noise(Max) 2mV pk-pk Battery 9Vbattery

Voltage and current ratings Maximum working current(a) Maximum floating Rating Rating Range Range Maximum floating 5mV/A 50mV/A DC 測定 50 5 600 600 DC + peak AC 50 5 600 600 AC peak 50 5 600 600 AC peak-peak RMS CAT III RMS 100 10 1200-35.4 3.54 600 600 35.4 3.54 600 600 RMS CAT I 35.4 3.54 600 600 CAT II PT-2770 Basic Operation: Before using the probe, the batteries must be installed. WARNING! Do not clamp the probe onto circuits with voltages greater than 600 VAC. Personal injury or damage to the probe may result. Always connect the PT-2770 current probe output to the instrument before clamping onto the circuit under test. 1. First connect the current probe BNC connector to BP-250 (double BNC connection cable) then connect to oscilloscope input. Start by setting the oscilloscope voltage input channel to DC volts, and the voltage sensitivity scale to 2m V/div. 2. Move the OFF/ Range switch to the 2 mv/a or 20 mv/a position to turn on the probe. ( The PT-2770 current probe has a green LED power/battery indicator. If the LED does not light, replace the battery or use specified power adaptor.) 3. Use the ZERO adjustment to zero or offset the probe output detection of residual magnetic DC charges. 4. Connect the probe to the circuit by opening the jaws and clamping around the conductor. See Figure 2.

NOTE. Clamping around both the hot hot and neutral wires may give you a zero reading. (Remember to unclamp the probe from the conductor before disconnecting it from your meter or instrument). 5. Adjust the probe channel and oscilloscope s time base as necessary to get a clear and stable view of the signal. Set the oscilloscope input to DC volts to see both the AC and DC currents; set the channel to AC to see the AC current only. The current drawn by different devices look much different than that of others. While the RMS current can only be used in low frequency current, the momentary peaks may be quite high. Figure 3 shows the difference between the line current drawn by a resistive load and a motor controller. Congratulations on your purchase of the PT-2770, a multifunctional current probe. When connecting to a digital meter, use the recommended MT-246N (BNC-to-banana adapter). Connect the black lead to the meter COM (black letters on the meter), and the red lead to the VΩ input (red letters on the meter). To measure only AC current, set the meter to measure AC volts. To measure DC current, set the meter to measure DC volts. Note the current convention arrow on the probe to get the proper polarity reading. To increase the measurement sensitivity of the PT-2770 current probe, loop additional turns of the wire under test through the jaws. See Figure 4. The sensitivity of the PT-2770 current probe is multiplied times the number of loops in the jaws. For example: 20mV/A X5turns=100mV/A

Electrical Characteristics Current Range 2mV/A ; 20mV/A ±2% ±50 ma at 20mV/A DC Accuracy, typical (50mA to 60 A peak range) ±2% ± 1A at 2mV/A (1A to 750 A peak range) Current 750A Frequency Range DC to 150KHz (-3 db) Rise time,typical 2.3uS Noise(Max) 2mV pk-pk Battery 9Vbattery Voltage and current ratings Maximum working current(a) Maximum floating Rating Rating Range 5mV/A Range 50mV/A Maximum floating DC 測定 50 5 600 600 DC + peak 50 5 600 600 AC AC peak 50 5 600 600 AC peak-peak 100 10 1200 - RMS CAT III 35.4 3.54 600 600 RMS 35.4 3.54 600 600 RMS CAT I 35.4 3.54 600 600 CAT II Maintenance: Use the information in this section to properly maintain the operation of your PT2000 AC/DC Current Probe. 1. Notes on Battery and Power Converter: The PT2000 current probe uses a single square 9 V battery. This machine is a high power product. Please use the specified alkaline battery.

As the battery in the PT2000 current probe is drained, significant gain errors may occur. The green LED will continue to light until a low battery voltage of 6.5 V is reached. If probe gain errors are detected, replace the battery with a fresh one. If not using this item(more than 1 week),we suggest you remove the battery from the compartment. This is because heating will result in battery leakage, and battery electrolyte will rust the circuit board,thus creating major damage. Furthermore, batteries are high pollution products and therefore by reducing their usage, we will in turn protect the environment. This will avoid leakage of battery since the quality of the batteries is something that is out of our control. 2. Battery Installation: (1) Remove the probe from the circuit. (2) Open the battery compartment by taking the cover off. Install/replace the battery. (3) While observing polarity, attach the new alkaline battery to the battery connector buttons and place the battery in the specified area. (4) Place the cover back and lightly tighten the cover in place. 3. Cleaning: To clean the probe exterior, use a soft cloth dampened in a solution of mild detergent and water. To clean the core, open the jaw and clean the exposed core surfaces with a cotton swap dampened with isopropyl alcohol (isopropanol). Lubricate the jaws mating surfaces with light oil. Do not clean with solvents or abrasives. Do not immerse the probe. 4. Preparation for Shipment Our company has designed a special box to be used for PT2000, convenient for storage and shipment. Please do not discard it. If the original packaging is unfit for use or not available, use the following packaging guidelines: (1) Use a sturdy shipping carton having inside dimensions at least one inch greater than the probe dimensions. (2) Put the probe into a plastic bag or wrap to protect it from dampness. (3) Place the probe into the box and stabilize it with light packaging material. (4) Seal the carton with shipping tape. Specifications: These characteristics apply to an adjusted PT2000 AC/DC Current Probe

installed on an oscilloscope of any brand. The oscilloscope must be warmed up for at least 20 minutes and be in an environment with the temperature at 10 ~30 and the humidity at 0~80. Detail: Size 231 mm x67 mm x 36 mm Maximum Conductor Size Cable Length Weight 10.3 mm 200 cm 310 g (without battery) Environmental Characteristics Temperature Working Storage 0 C to +50 C (+32 F to +122 F) -20 C to +80 C (-4 F to +176 F) Humidity 0 C to 40 C, 95% humidity 40 C to 50 C, 45% humidity Pollution Degree 2 Replaceable Parts: The PT2000 AC/DC Current Probe is shipped with the following items: One instruction manual One 9V battery Recommended accessory for use with digital meter: One BNC to banana plug adapter Product number MT-246N. Designed with color fool proof design to avoid polarity mistake when connecting to digital meter. The PT2000 series does not have any user repairable assemblies. If you should have trouble with your probe, contact your local Service Center or representative for help.

PT-2000 series buying guide Model Bandwidth Input Impedance Current Measurement Range Attenuation Ration PT-2710 100KHZ 2% 0.05A/10A;1A/60A 5mV/A;50mV/A PT-2720 150KHZ 2% 0.05A/10A;1A/200A 2mV/A;20mV/A PT-2740 150KHZ 2% 0.05A/60A;1A/500A 2mV/A;20mV/A PT-2770 150KHZ 2% 0.05A/60A;1A/750A 2mV/A;20mV/A