External seismic pre-isolation retrofit design

Similar documents
The X-arm interferometer test of HEPI at LIGO Livingston

Enhanced LIGO HAM ISI Prototype Preliminary Performance Review T

Improving seismic isolation in Advanced LIGO using a ground rotation sensor

7th Edoardo Amaldi Conference on Gravitational Waves (Amaldi7)

Control Servo Design for Inverted Pendulum

Arm Cavity Finesse for Advanced LIGO

Advanced Virgo commissioning challenges. Julia Casanueva on behalf of the Virgo collaboration

Results from the Stanford 10 m Sagnac interferometer

Mechanical modeling of the Seismic Attenuation System for AdLIGO

A gravitational wave is a differential strain in spacetime. Equivalently, it is a differential tidal force that can be sensed by multiple test masses.

DRAFT Expected performance of type-bp SAS in bkagra

The VIRGO suspensions

Seismic Noise & Vibration Isolation Systems. AIGO Summer Workshop School of Physics, UWA Feb Mar. 2, 2010

PRM SRM. Grav. Wave ReadOut

ACOUSTIC MITIGATION STATUS FOR S3

CALIFORNIA INSTITUTE OF TECHNOLOGY Laser Interferometer Gravitational Wave Observatory (LIGO) Project

CHAPTER 3. Multi-stage seismic attenuation system

The AEI 10 m Prototype. June Sina Köhlenbeck for the 10m Prototype Team

LIGO Photodiode Development and Optical Platform for LIGO Photodetectors Testing

SmartSenseCom Introduces Next Generation Seismic Sensor Systems

Commissioning of Advanced Virgo

Optical bench Seismic Isolation System (SAS) Prototyped for the HAM chambers of the Advanced LIGO Interferometers

Understanding Initial LIGO and Possible Influences on Enhanced LIGO. Sam Waldman and Rai Weiss February 2008

Active Vibration Isolation of an Unbalanced Machine Tool Spindle

Multiply Resonant EOM for the LIGO 40-meter Interferometer

How to Build a Gravitational Wave Detector. Sean Leavey

TNI mode cleaner/ laser frequency stabilization system

Wavelength Control and Locking with Sub-MHz Precision

Development of Optical lever system of the 40 meter interferometer

Installation and Characterization of the Advanced LIGO 200 Watt PSL

Recent Work at the Stanford Engineering Test Facility

Interferometer signal detection system for the VIRGO experiment. VIRGO collaboration

LIGO PROJECT. Piezo-Electric Actuator Initial Performance Tests. Eric Ponslet April 13, Abstract

Designing Optical Layouts for AEI s 10 meter Prototype. Stephanie Wiele August 5, 2008

Quiet Hydraulic Actuators for LIGO

Angular control of Advanced Virgo suspended benches

This is a brief report of the measurements I have done in these 2 months.

Experimental Test of an Alignment Sensing Scheme for a Gravitational-wave Interferometer

GAS (Geometric Anti Spring) filter and LVDT (Linear Variable Differential Transformer) Enzo Tapia Lecture 2. KAGRA Lecture 2 for students

Readout and control of a power-recycled interferometric gravitational wave antenna

NINTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, ICSV9 ACTIVE VIBRATION ISOLATION OF DIESEL ENGINES IN SHIPS

Conventional geophone topologies and their intrinsic physical limitations, determined

PUSHING THE ADVANCED VIRGO INTERFEROMETER TO THE LIMIT

ISC RF Photodetector Design: LSC & WFS

The Virgo detector. L. Rolland LAPP-Annecy GraSPA summer school L. Rolland GraSPA2013 Annecy le Vieux

Koji Arai / Stan Whitcomb LIGO Laboratory / Caltech. LIGO-G v1

Servo Tuning. Dr. Rohan Munasinghe Department. of Electronic and Telecommunication Engineering University of Moratuwa. Thanks to Dr.

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Electronics and Instrumentation Name ENGR-4220 Fall 1999 Section Modeling the Cantilever Beam Supplemental Info for Project 1.

Sensing and control of a six-dof maglev-based suspension prototype

Omar E ROOD 1, Han-Sheng CHEN 2, Rodney L LARSON 3 And Richard F NOWAK 4 SUMMARY

A Machine Tool Controller using Cascaded Servo Loops and Multiple Feedback Sensors per Axis

9) Describe the down select process that led to the laser selection in more detail

Improving the Performance of a Geophone through Capacitive Position Sensing and Feedback. Aaron Barzilai. Stanford University

Response spectrum Time history Power Spectral Density, PSD

GROUND MOTION IN THE INTERACTION. ensured that the final focus quadrupoles on both. rms amplitudes higher than some fraction of the

Some Progress In The Development Of An Optical Readout System For The LISA Gravitational Reference Sensor

Applications of Passivity Theory to the Active Control of Acoustic Musical Instruments

ACTIVE VIBRATION CONTROL OF HARD-DISK DRIVES USING PZT ACTUATED SUSPENSION SYSTEMS. Meng-Shiun Tsai, Wei-Hsiung Yuan and Jia-Ming Chang

Stabilizing an Interferometric Delay with PI Control

high, thin-walled buildings in glass and steel

Strong Motion Data: Structures

The Air Bearing Throughput Edge By Kevin McCarthy, Chief Technology Officer

Calibration of the LIGO displacement actuators via laser frequency modulation

Tilt sensor and servo control system for gravitational wave detection.

VIRGO. The status of VIRGO. & INFN - Sezione di Roma 1. 1 / 6/ 2004 Fulvio Ricci

Review of 40m upgrade goals ffl The primary goal of the 40 m upgrade is to demonstrate a scheme for using resonant sideband extraction (RSE), in eithe

LIGO. Advanced LIGO. Keita KAWABE, LIGO Hanford, Caltech LIGO-G

Module 4 TEST SYSTEM Part 2. SHAKING TABLE CONTROLLER ASSOCIATED SOFTWARES Dr. J.C. QUEVAL, CEA/Saclay

New Long Stroke Vibration Shaker Design using Linear Motor Technology

Application Note #2442

Dynamic Vibration Absorber

Quantum States of Light and Giants

LIGO-P R Detector Description and Performance for the First Coincidence Observations between LIGO and GEO

Part 2: Second order systems: cantilever response

CONTROLS CONSIDERATIONS FOR NEXT GENERATION GW DETECTORS

Using a Negative Impedance Converter to Dampen Motion in Test Masses

Vibration measurement in the cryogenic interferometric gravitational wave detector (CLIO interferometer)

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine

Six degree of freedom active vibration isolation using quasi-zero stiffness magnetic levitation

A simple high-sensitivity interferometric position sensor for test mass control on an advanced LIGO interferometer

Noise Budget Development for the LIGO 40 Meter Prototype

Virgo status and commissioning results

Stable Recycling Cavities for Advanced LIGO

Plans for DC Readout Experiment at the 40m Lab

Toward the Advanced LIGO optical configuration investigated in 40meter prototype

Active Vibration Control in Ultrasonic Wire Bonding Improving Bondability on Demanding Surfaces

Preliminary Optical Fiber Stabilization for AdvLIGO Pre-Lock Acquisition System

Stable recycling cavities for Advanced LIGO

Contents: Movement & Positioning News M&P 23, 1997, Text Only Version

FIRST REAL-LIFE RESULTS OF NOVEL MICRO VIBRATION MEASUREMENT FACILITY

Development of the accelerometer for cryogenic experiments II

The VIRGO injection system

Servo Loop Bandwidth, Motor Sizing and Power Dissipation. Mark Holcomb Senior Engineer, Motion Control Specialist Celera Motion

Synchronization Control Scheme for Hybrid Linear Actuator Based on One Common Position Sensor with Long Travel Range and Nanometer Resolution

First results of a high performance optically-pumped cesium beam clock

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor

Advanced Virgo Technical Design Report

Angular Drift of CrystalTech (1064nm, 80MHz) AOMs due to Thermal Transients. Alex Piggott

Mechanical Spectrum Analyzer in Silicon using Micromachined Accelerometers with Time-Varying Electrostatic Feedback

Transcription:

External seismic pre-isolation retrofit design J. Giaime, B. Lantz, C. Hardham, R. Adhikari, E. Daw, D. DeBra, M. Hammond, K. Mason, D. Coyne, D. Shoemaker April 3, 2002 T020040-00-D Contents 1 Introduction 1 2 Active seismic isolation 2 3 External seismic pre-isolation strategy 4 3.1 System overview.... 4 3.2 Low-frequency actuation allocation..... 6 4 Proof-of-principle tests 7 4.1 2-DOF external seismic pre-isolation of a BSC SEI.............. 7 4.2 2-DOF control using hydraulic actuator prototypes.............. 9 5 LLO Noise measurements 10 1 Introduction This technical note outlines the design of an external seismic pre-isolation system proposed for use in LIGO Livingston. The goal is to reduce the effects of the site s excess ground noise in the 1-3 Hz frequency band, allowing detector noise performance equivalent to that of the 4 km LIGO Hanford detector. The center histogram in Figure 8 shows the most troubling aspect of the excess noise quite clearly. The typical 1-3 Hz RMS velocity at LHO is about 2 10 8 m/s, but at LLO it is typically 10-20 times that during the day. This both makes length control servo lock difficult, and requires greater test mass actuation that adds noise in the gravitational-wave band. In addition, Figure 9 shows that peak velocities in at LLO in the 1-3 Hz band are often as large as 2-5 µm/s. In order to achieve the promised detector performance at LLO, we are considering proceeding with the rapid development, testing, and installation of an additional stage of seismic isolation, shown in Figure 1. This stage would physically support 1

Figure 1: Elevation sketch of a BSC seismic isolation system, with its passive stack payload, external hydraulic actuators, and sensors. The pier-top sensor/actuator package is to be installed on each of the four corners, providing some redundancy on the system s 6 DOF s. and actively reduce the mechanical noise in the external seismic isolation support structure, replacing the currently installed coarse and fine actuation systems. Reference [1] lists in detail the requirements for the upgrade under consideration here. (The upgrade is very similar to a stage already under development for Advanced LIGO [5, 6], intended to meet the Advanced LIGO seismic isolation requirements set out in [8].) 2 Active seismic isolation Active vibration reduction in 6 DOF s has been demonstrated using several techniques. In general, one can measure both the payload s motion and the disturbance (e. g., the floor motion), and use that information to servo the platform s position to that desired by a global commanded position, itself perhaps based on other vibration measurements or the interferometer state. Figure 2 can help explain the relationships among the feedback, feedforward, and sensor correction techniques. We intend to use all three in this retro-fit design. Feedback: Environmental noise, which can come in the form of ground noise, acoustic noise, or even temperature, couples into the system s output y through the dynamics in G d. 2

environment sensor noise n d (ω) environmental disturbance d(ω) command input r(ω) y (ω) m measured environment feedback controller K(s) M(s) sensor correction K (s) ff - n (ω) f feed-forward controller force actuation actuator noise other measurements system dynamics G(s) G d(s) measured motion "real" output y(ω) motion sensor n s(ω) noise Figure 2: System-level generic diagram of the control signal flow within an external vibration reduction system. This includes the controller functions, mechanical dynamics, sensing and actuation, all presumed to be 6 DOF. The places where noise and environmental disturbance influence the system are indicated. We wish to control y to follow the commanded r, andcloseafeedback loop. y is measured with a sensor that adds noise n s ;thismeasuredvalue is subtracted from the desired value r, multiplied by the control law K, andapplied as a force (with added noise n f )tothesystem, which responds with dynamic function G to give its output, the system s remaining motion. With only feedback, the output can be described by the equation, y = (I GK) 1 GK r command tracking (I GK) 1 G d d disturbance suppression (I GK) 1 GK n s sensor noise (I GK) 1 Gn f, force actuator noise where I is the identity matrix for however many DOF s are being controlled. The addition of feedback gain in K suppresses the environmental noise d from the output. If K is sufficiently high, the system tracks r down to a noise floor set by n s. Feed-forward: If K ff G = G d,thenthe environmental disturbance is removed from the system. In practice, this technique is limited by the sensor noise n d,sincethesensorsignal must usually be bandpass filtered to avoid introducing excess noise in frequencies where the sensor is not effective. (This filtering can introduce extra phase shifts that prevent perfect 3

cancellation, which is not reflected in the equation above). While it is true that feedback gain reduces the value at y resulting from the feed-forward correction path by (I GK) 1, the environmental disturbance coupling through K d is reduced by the same factor, making feed-forward effective regardless of the feedback scheme. Sensor correction: When a particular sensor s output is corrupted by either environmental noise or unwanted DOF s, the block M can be used to subtract off these things, leaving a best guess measurement for use in the feedback path. Two examples of this corruption can be seen in our system, ground motion coupling into the relative position sensors by shaking the SEI piers, and the pitch or yaw DOF s being sensed at low frequencies as horizontal motion in the seismometers. Each of these can at least partially be corrected. In the case of position sensor correction, we can measure the floor motion with a seismometer to provide the correction signal. Sensor correction differs fundamentally from feed-forward in that it does nothing to the system unless the feedback loop is active. Badly implemented sensor correction can also destabilize the feedback control; feed-forward, done badly, just adds noise. 3 External seismic pre-isolation strategy 3.1 System overview global length control, global feed-forward and tidal correction feedback controller force actuation platform & pier dynamics platform motion corrected measured motion sensor correction geophone measurement supersensor L-4C sensors DIT-5200 sensors displacement measurement floor-mounted seismometer measurements Figure 3: More detailed diagram of the local control loop portion of Figure 2, showing where various sensor signals are employed. At left, in purple, the servo is commanded to follow global interferometer length signals and feed-forward correcting signals. The blue sensor correction signal, derived from local seismometer measurements, is used to (for example) correct the relative displacement sensor for the known motion of the local floor. We plan to use the sensors and actuators shown in Figure 1 to implement feedback and feed-forward in a 6-DOF servo of the external seismic isolation system crossbeam displace- 4

Impact of sensor noise on hydraulic system performance 10-6 10-7 closed loop DIT5200 noise closed loop L4-C noise closed loop noise floor input noise of DIT5200 input noise of L4-C motion ASD (m/ Hz) 10-8 10-9 10-10 10-11 10-12 10-13 10-1 10 0 10 1 10 2 freq (Hz) Figure 4: Modelled sensor-originated noise levels in external seismic pre-isolation. ment. Each existing coarse actuation system and fine actuation system is to be removed. The seismic crossbeam will be supported by a new stiff-spring suspension assembly and actuated by a vertical and tangential hydraulic force-bridge at each pier [2]. (Or, as a backup if the hydraulic device cannot be made to work, an electromagnetic actuator [3].) Figure 3 is a diagram of the local control system. Signals from the 8 local relative displacement sensors, measuring the extension of each of the actuators, and from the 8 geophones mounted in the moving (payload) part of the actuator, are combined in the form of a 8-DOF super-sensor. The part of the super-sensor that comes from relative displacement sensors is corrected (in at least 3 of its DOF s) for the STS-2 seismometer measured motion of the local floor. This corrected measured motion, is used to calculate error signals for the 8 local loops. The (corrected) displacement sensors dominate the error functions at low frequencies (f 0.5 Hz), augmented by the (already implemented) microseism feed-forward and Earth-tidal correction in the laser beam direction. Since most of the troublesome test mass velocity observed at LLO occurs at the stack s 1.2 and 2.1 Hz resonances (see Figure 6), we expect to enhance the loop gain in the geophone at those frequencies in the blend to form the super-sensor. We expect an upper unity gain frequency the super-sensor loop of about 20 Hz. The impact of sensor noise on the system performance can be seen in Figure 4. This was calculated using a 1-D model of a servo loop with two sensors, one actuator, and an upper unity gain frequency of 20 Hz. This calculation assumes a well behaved plant with no crosscoupling, which allows plant dynamics to be completely ignored. The sensors are the Sercel L-4C 1 Hz geophone readout by a LT1001, and a Kaman DIT-5200 displacement sensor. The input referred noise for the L-4C is calculated based on geophone characteristics and the noise of the LT1001. The input referred noise for the DIT-5200 is based on measurements 5

by W. Hua of a sensor 1 mm from the center (i.e., the worst-case location). These sensor noise terms are shown as the dashed lines in Fig. 4. The two sensors are blended at 0.5 Hz using reasonable blending filters. The input noise of the sensors appears as the input noise times the forward loop divided by 1 plus the loop gain. The closed loop noise curves are shown as the solid lines. The two noise terms are then added in quadrature to show the impact of sensor noise on the instrument performance (the dashed magenta curve). It is interesting to note that well above 0.5 Hz, even though the main signal for the loop comes from the geophone, the noise is dominated by the displacement sensor, due to its relatively large noise and the conservative nature of the blending used. The design of the 6-DOF servo loops has not been completed, so we rely on past experience in modelling and testing 6-DOF systems for confidence that stability can be obtained [5, 9, 10, 12]. We expect the geophone inertial servo to provide about a factor of -15 db in vibration transmission in the 1-3 Hz band, enhanced by another factor of a few by targetted resonant gain at the troublesome stack modes. In addition, sensor correction from the floor-mounted STS-2 is expected to give a similar reduction. The latter technique has been tried in a hydraulic test stand at Stanford [2, 6], with performance comparable to what is needed here. 3.2 Low-frequency actuation allocation Much attention was paid during LIGO s design to avoiding parasitic interferometers between the core optics and non-seismically-isolated structures and optical elements, such as the output optics (see, for example, [13]). A consensus seems to exist that as long as the moving (and light-scattering) object s velocity is less than about 10 µm/s thereisless concern about fringe-wrapping effects inserting noise in the GW band. If we actively or passively quiet the core optics to follow inertia, there will be a relative velocity between them and the floor-mounted components corresponding to the ground velocity. Figure 8 tells the unhappy story that there is from time to time RMS ground velocity 1 µm/s ineach of the frequency bands monitored. Because of this, both the LSC feedback to the test masses and the feed-forward correction for the DF microseismic peak are largely actuated in the ETM s. Other than the extremely small fraction of light ( 10 5 in intensity) transmitted through the ETM s, no beams exit the ETM tanks. So the fairly large relative motion between each ETM and the adjoining vacuum equipment and lab is less likely to produce parasitic interferometers. Our baseline design for the external pre-isolation retrofit calls for noise reduction locally at each tank, including the ITM s, with the possible exception of the microseismic correction, which will probably continue to be applied only at the ends. The retrofit system will be identical for all BSC tanks to allow operational flexibility in this. If the parasitic interferometer noise effect becomes a problem, one solution may be to put the external optics tables on seismic isolation mounts. 6

4 Proof-of-principle tests 4.1 2-DOF external seismic pre-isolation of a BSC SEI As a test of external actuation, the existing fine actuators were used to close two SISO active seismic isolation loops on LLO s Y-end BSC, as is shown in Figure 5. SISO controller, East and West global feed-forward and tidal correction controller feedback PZT actuation platform & pier dynamics platform motion GS-13 sensors geophone measurement Figure 5: Componentsetup for proof-of-principle test of external pre-isolation, together with servo diagram. We placed GS-13 geophones on the east and west sides of the northern cross beam, and used each filtered output as an error signal for an actuator pair. The existing fine actuation system employs a PZT stack whose length is controlled by a drive voltage as part of a PID servo based on an error signal from a colinear strain gauge. We added our geophone-derived error signal at the summing node of the PZT servo. This is topologically very similar to the super-sensor blend that is planned for the retrofit. By using two SISO loops, we were able to avoid instability due to the observed strong coupling to the stack s 6 Hz yaw mode. We found a very stable loop design having a lower unity gain frequency of about 0.7 Hz. (This is actually a blending point, to the strain-gauge-dominated low frequencies.) The upper UGF is about 7 Hz, and about 10 db of active noise reduction was obtained in this band. In addition, two resonant gain filters were inserted, allowing the performance seen in Figure 6, measured by monitoring the test mass position with respect to its frame. Figure 7 shows the reduced control signal needed to maintain lock in the Y-arm with the end ETM under active isolation. That particular night excitation of the 2.1 Hz stack mode was dominated by the end station, so it is reduced by a factor of 5 rather than the expeced 2thatisseen in the 1.2 Hz peak. This system demonstrates that external seismic pre-isolation can work, although in this case only in the beam direction. 7

70 60 ETMY POS MON (w/ feedback) ETMY POS MON rms (w/ feedback) ETMY POS MON (normal) Magnitude (cts/rthz) 50 40 30 20 ETMY POS MON rms (normal) 10 10-1 1 10 Frequency (Hz) Figure 6: The POS output of the ETMY SUS controller, with no global control signals, during a test of 2-DOF external pre-isolation during the evening of March 3, 2002. 10 3 Magnitude (cts/rthz) 10 2 10 CARM CTRL (w/ feedback) CARM CTRL rms (w/ feedback) CARM CTRL rms (normal) CARM CTRL (normal) 10-1 1 10 Frequency (Hz) Figure 7: Control signal needed to keep LLO s Y-arm in lock during a test of 2-DOF external pre-isolation during the evening of March 3, 2002. 8

4.2 2-DOF control using hydraulic actuator prototypes References [2, 7, 11] describe tests done at Stanford implementing displacement sensor local feedback with sensor correction in two (vertical and horizontal) degrees of freedom. This was carried out using a prototype hydraulic actuator on a test stand holding a spring-suspended realistically-heavy payload. 9

5 LLO Noise measurements Figure 8: Histograms of the root-mean-squared ground velocity (in m/s) at the two LIGO observatory sites in five frequency bins over 40 days. RMS values above 2 µm/s inthe1-3hzband are rare. Also note that velocities approaching and exceeding 1 µm/s occur in every band shown, at both sites. 10

Figure 9: Histogram of the peak velocities of 1-3 Hz band-limited ground vibration data at LLO, produced by Ed Daw. The data apparently fall into two distributions, probably night/weekend (the narrow central peak), and daytime. Even the latter, and the cause of LLO s difficulties, only very rarely has events greater than 2 µm/s. None were seen greater than about 5 µm/s during this 40-hour data set. We plan on continuous monitoring of this at LLO to gather more statistics. 11

References [1] B. Lantz, J. Giaime, P. Fritschel, R. Weiss, D. Coyne, D. Shoemaker, Initial LIGO Seismic Isolation Upgrade Design Requirements Document. 3/7/02. LIGO-T020033-01-D. [2] B. Lantz, and others, Quiet Hydraulic Actuators for Initial LIGO. LIGO-T020047-00-D. [3] D. Shoemaker, ed., Pre-Isolator with Electromagnetic Actuator: Conceptual Design, Test Plan. LIGO-T020041-00-D. [4] D. Coyne, ed., Initial LIGO Seismic Isolation Upgrade: Conceptual Design Document. LIGO-T020050-00-D. [5] J. Giaime, B. Lantz, C. Hardham, W. Hua, R. Adhikari, D. Debra, G. Hammond, J. Hammond, J. How, S. Richman, J. Rollins, G. Stapfer, R. Stebbins, Advanced LIGO Seismic Isolation System Conceptual Design. 1/20/01. LIGO-E010016-00-D. [6] R Abbott, R Adhikari, G Allen, S Cowley, E Daw, D DeBra, J Giaime, G Hammond, M Hammond, C Hardham, J How, W Hua, W Johnson, B Lantz, K Mason, R Mittleman, J Nichol, S Richman, J Rollins, D Shoemaker,G Stapfer and R Stebbins, Seismic Isolation for Advanced LIGO, Class. Quantum Grav. 19 1591-1597. (7 April 2002) [7] J. Giaime, B. Lantz, S. Richman, D. Debra, C. Hardham, J. How, and W. Hua, Baseline LIGO-II implementation design description of the stiff active seismic isolation system. 3/8/2000. LIGO-T000024-00-U [8] P. Fritschel, D. Coyne, J. Giaime, B. Lantz, D. Shoemaker, Seismic Isolation Subsystem Design Requirements Document. 1/17/2001 LIGO-E990303-03-D [9] Brian Lantz, Wensheng Hua, Sam Richman, Jonathan How, Computer Modeling and Simulation in Support of the Stiff-Suspension Active Seismic Isolation for LIGO II, 2/14/2000, LIGO T000016-01 [10] Wensheng Hua, Brian Lantz, Sam Richman, How to construct mechanical model of a mass-spring system, http://lsuligo.phys.lsu.edu/active/pen3.pdf [11] B. Lantz, R. Stebbins, C. Hardham, J. Giaime, The experimental program in support of stiff-suspension active seismic isolation for LIGO-II, 2/14/2000, LIGO T000015-00. [12] Richman, S.J.; Giaime, J.A.; Newell, D.B.; Stebbins, R.T.; Bender, P.L.; Faller, J.E.; Multi-stage active vibration isolation system, Review of Scientific Instruments, 69:6, 2531. (June 98) [13] Smith, M., Up-Conversion of Scattered Light Phase Noise from Large Amplitude Motions LIGO-T980101-00-D. [14] Hong Sang Bae, Active Vibration Isolation and Alignment Issues for LIGO, Masters Thesis, Department of Mechanical Engineering, Stanford University, August 1999. 12