Arc Suppression Coils

Similar documents
THE RCC GROUND FAULT NEUTRALIZER

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

3. COMBINED TRANSFORMERS Oil-paper insulation

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

GREEN TRAFO PRODUCTS SHR - THREE-PHASE SHUNT REACTOR

Capacitive voltage transformers

OIL-IMMERSED ARC-SUPPRESSION COILS

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

Substation Preventive Maintenance

Capacitive voltage transformers

4. CAPACITIVE VOLTAGE TRANSFORMERS AND COUPLING CAPACITORS Oil-paper insulation

Resistive capacitive voltage divider

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

Medium voltage circuit breaker technical guide

User s Manual For CT Model IMB

ELETTROMECCANICA. Since english OIL IMMERSED DISTRIBUTION TRANSFORMERS

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

Products for High Voltage Application. AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

Commissioning Manual Distribution Transformers - Three-phase Oil Filled

RESONANT TRANSFORMER

SAFETY ASPECTS AND NOVEL TECHNICAL SOLUTIONS FOR EARTH FAULT MANAGEMENT IN MV ELECTRICITY DISTRIBUTION NETWORKS

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

SHARDA Make Harmonics Filter

Stabilized Differential Relay SPAD 346. Product Guide

Your safety first! This is the reason why our manual begins with the following guidelines:

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Resistive capacitive voltage divider

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

Magtech Voltage Booster MVB

PPC TECHNICAL SPECIFICATION D/ NCMD / THREE-PHASE DISTRIBUTION TRANSFORMERS

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

Series P. Applications

Protection of Electrical Networks. Christophe Prévé

DEIF A/S. Insulation monitor. Type SIM-Q

Introduction. Centrado leading-edge transformer. Introduction

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

DISTRIBUTION TRANSFORMER 11 / kv

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Onsite Mobile AC High Voltage Test System

TS RES - OUTSTANDING ISSUES

ELECTRICAL POWER TRANSMISSION TRAINER

DISTRIBUTION TRANSFORMER kv

Oil-immersed Transformers

Technical Questionnaire 9.101/6 Transformer Test System. Personal Data. Application. Test of. Delivery scope

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

AC Resonant Test Systems Tank Type Up to 500 kv

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

Inductive Voltage Transformers. Types VEOT and VEOS

Combined Instrument Transformers. Types IVOKT and TMC

Resistive capacitive voltage divider

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

EI HIGH VOLTAGE INSULATION TESTING POLICY

Tertiary Winding Design in wye-wye Connected Transformers Restricted Siemens Energy 2013 All rights reserved.

AC Resonant Test Systems Tank Type Up to 150 kv

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

Magtech Voltage Booster MVB

VOLTAGE DETECTING SYSTEMS

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

Distribution transformers Part 2 Ground mounted transformers not closecoupled

MESP TECHNICAL SPECIFICATION FOR A 1500V DC RECTIFIER TRANSFORMER

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Transformer condition assessment with an integrated test van

Basic Principles and Operation of Transformer

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

Phase and neutral overcurrent protection

(

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

1ZSC AAJ en, Rev. 1. Vacuum on-load tap-changers, type VUBB Technical guide

2 Grounding of power supply system neutral

Earth Fault Protection

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Voltage Transformers type UMZ User s Manual, Operation and Maintenance

TECHNICAL SPECIFICATION SHEET

Transformer Protection

Transcription:

Arc Suppression Coils (22kV Arc Suppression Coils )

Introduction Resonance grounding by Petersen coils (Arc Suppression Coils) has been used in Scandinavia and other European countries for some eighty years. The excellent properties of this grounding concept are mirrored by very low outages rates. Resonance grounding is mainly used in overhead networks where most of the faults are single phase to ground and often of transient nature. The Petersen coil chokes the fault current below the level of self extinction (< 35 A) by compensating for the capacitive fault current of the network. By this action all transient faults can be cleared without feeder tripping. this remaining fault current it is necessary to trip the feeder to minimize the risk for fire and personal hazards in the network. To obtain safe continuous operation during earth faults Swedish Neutral can offer the Ground Fault Neutralizer system which compensates for the complete fault current (capacitive+active). The Ground Fault Neutralizer reduces the fault current to practically zero, for all types of earth faults, faster than any other protection, while also maintaining power supply to the customers no feeder tripping! However sustained faults on overhead lines and cable faults cannot be cleared by any Arc Suppression Coil since no coil can compensate for the active part of the fault current. Due to

Arc Suppression Coil (ASC) To reduce the capacitive fault current during an earth fault effectively the ASC needs to be tuned to the capacitive leakage of the network at the time of the earth fault. The capacitive leakage to ground is determined by the present size of the network, which in turn is determined by the number of feeders, overhead/cable, length of the feeders and other factors. The Swedish Neutral ASC has a modern solid core design with one fixed winding and one auxiliary winding. To the auxiliary winding a capacitor bank is connected. The ASC is tuned by connecting the different elements of the capacitor bank in different combinations to the auxiliary winding. The sum of the capacitive leakage in the network can change for different reasons. One example is when a feeder is disconnected (reducing the sum of the capacitive leakage of the network). When the capacitive leakage is reduced an appropriate number of capacitors is connected to tune the coil to the network. If instead a feeder is connected to the network (increasing the sum of the capacitive leakage of the network) an appropriate number of capacitors are disconnected. In 2006 Swedish Neutral sold its first oil free ASC for outdoor use. This coil has the same solid core design as the hermetically sealed oil immersed ASC with the difference that the winding is made up of a medium voltage cable using the screen as auxiliary winding. Taking away the oil has a number of advantages no oil catch needed, no need for emptying the oil catch from water/analyzing the water for oil, environmentally friendly possible to install in sensitive areas. N 2.1 2.2 1.2 1.1 Main Circuit Diagram Oil Free ASC

Hermetically Sealed Design ASC Modern solid core No moving parts robust design Hermetically sealed tank No maintenance no oil samples needed Standard tuning range 10 100% Other tuning ranges on request From min to max position in <1s Fastest coil on the market Resolution <1% More step less than a step less coil Swedish Neutral has been producing Arc Suppression Coils since 1991 and has sold over a 1000 around the world. Oil Free Design ASC Modern solid core No moving parts robust design Oil free No oil catch needed environmentally friendly Stainless Steel Enclosure No rust Standard tuning range 10 100% Other tuning ranges on request From min to max position in <1s Fastest coil on the market Resolution <1% More step less than a step less coil

Arc Suppression Coils Layout Hermetically Sealed Design Swedish Neutral Oil Free Design Swedish Neutral Legend 1. Current transformer (optional) 2. Local control panel 3. Mounting holes (16mm) for fixation of the Arc Suppression Coil to the foundation (optional wheels). 4. Low voltage bushing for auxiliary and control voltage. 5. High voltage bushing Elastimold: Load break/dead break, DIN, Pfisterer connect to neutral of the power or grounding transformer. 6. Earthing terminal M12 Screw connect to system earth 7. Rating plate (movable) 8. Parking stand 9. Lifting lugs (inside hatch) 10. Service hatch 11. Haulage lugs 12. Cable tray (optional) 13. Protective earth connect to protective earth.

Technical specifications Voltage Up to 130/ 3 kv Current Up to 1000A Tuning range 10-100%, other tuning ranges on request Resolution <1% Duty Continuous or short time (2 hours) Cooling methods Hermetically sealed ASC Oil free ASC ONAN (ANSI/IEE C57.12.00) Class AA or Class AFA (ANSI/IEE C57.12.01) Frequency 50 or 60 Hz Installation Indoor or Outdoor Secondary winding voltage 690 V and 345 V Insulation level According to the rated voltage (IEC70076-3) Ambient temperature -40 to +40 C, other temperatures on request Insulation oil in hermetically sealed ASC Nynas: Nytro Taurus Starke & Sohn: Transformer Oil U Midel 7131 Other oils on request Routine Tests Visual inspection (SS EN 60439) Protective earth continuity test (SS EN 60439) Verification of correct wiring (SS EN 60439) Verification of correct function (IEC 60076 6) Measurement of capacitance (SN test routine) Measurement of reactance (SN test routine) Primary winding resistance (IEC 60076 1) ASC secondary winding ratio (IEC 60076 6) Rated voltage / current test (IEC 60076 6) HV insulation test (IEC 60076 6) LV winding insulation test (3kV ~ 60s) (IEC 60076 6) Control circuit voltage withstand test (SS EN 60204) (1kV ~ 1s *PELV circuits not included) Measurement of losses (IEC 60076 1) Type tests According to IEC 60076 6 Measurement of current at rated voltage Temperature rise test Dielectric test Special tests On request, as per agreement

Contact and visiting us: Swedish Neutral AB Västra Rydsvägen 122 19631 Kungsängen Sweden Telephone +46 8 581 71344 Fax: +46 8 581 713 44 E-mail: mail@swedishneutral.se Internet: www.swedishneutral.se