GP C(D) 155Mbps SFP Optical Transceiver, 2km Reach

Similar documents
GP-5524-L8x(D) 1.25Gbps SFP Optical Transceiver, 80km Reach

AC05-A13L6-02 (-DD) 155Mbps SFP Optical Transceiver, 2km Reach

GLC LH SM. 1.25Gbps SFP Optical Transceiver, 20km Reach

GP-8524-S5x(D) 1.25Gbps SFP Optical Transceiver, 550m Reach

HT201-24D083M Gbps 850nm SFP Optical Transceiver, 550m Reach

3CP-485L1MN-SX 1.25Gbps SFP Optical Transceiver, 550m Reach

AOP-324-R20(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

XSS311-20LY. 1.25Gbps SFP Optical Transceiver, 20km Reach. Features. Applications. Description

1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1310nm TX / 1550 nm RX CFORTH-SFP-35-20S

1.25Gbps SFP Optical Transceiver, 550m Reach

SFP-7020-WB 1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

CWDM SFP 1.25G 40KM LC Duplex

SFP BIDI 2.488Gbps 20KM 1550nm TX/1310nm RX

1.25Gbps SFP Optical Transceiver, 550m Reach

GP-3124-L2x(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

GPB-5324L-L8CD 1.25Gbps SFP Bi-Directional Transceiver, 80km Reach 1550nm TX / 1310 nm RX

155Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

622Mbps SFP Optical Transceiver, 40km Reach FS-622M-A40

GPB-5303x-L2x(D) 155Mbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

1.25Gbps CWDM SFP Optical Transceiver, 80km Reach SFP-7080-Cxx

SFP M~2.67Gbps SFP Optical Transceiver, 300m Reach

FSPC-xx12-40D. 1.25G SFP CWDM 1470nm~1610nm 40km Optical Transceiver

622Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

1.25Gbps CWDM SFP Optical Transceiver, 40km Reach EPC-xx24-04C(D)

1.25Gbps SFP Optical Transceiver, 550m Reach EP-8524-S5x(D)

2.67Gbps CWDM SFP Optical Transceiver, 40km Reach GPC-xx48-04X(D)

1G SFP CWDM nm 80km Optical Transceivers

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

GLC-SX-MMD (1000BASE-SX SFP) Datasheet

SNS SFP-GDCWXD-XX* 1.25 Gbps 80 km CWDM SFP Transceiver

GPBC-xxxx24L-04CD 1.25Gbps SFP CWDM Bi-Di Single Fiber Transceiver, 40km Reach

GPB-4324x-L4x(D) 1.25Gbps SFP Bi-Directional Transceiver, 40km Reach 1490nm TX / 1310 nm RX

1.25Gbps SFP Optical Transceiver, 20km Reach GP L2x(D)

XSB531-20xx Gbps SFP Bi-Directional Transceiver, 20 km Reach, 1550 nm TX/1310 nm RX. Features. Applications. Description

SFP Optical Transceivers

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

MGS-MM MODULO GBIC SFP 500M 4.25GBPS LC MM 850NM VCSEL PIN TRANSCEIVERS

GPH-3102-L1C(D) 100BASE-LX Spring-Latch SFP Transceiver, 10km Reach

SGMII SFP 125Mbps 1310nm MMF 2KM SLSG D

EPON OLT 1.25Gbps 1000Base-PX20 Tx1490/Rx1310nm DDMI SLEP-1143-P

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

Product Specification Sheet

GDETP-XX21S-2CD DWDM EPON OLT SFP Transceiver

GNTP-4321S-C2CDA GPON SFP OLT Transceiver

GPON ONU SFF 2X10 GNUF-3412S-B2CDA

6Gbps SFP+ Optical Transceiver,10 Km (OP3B10D ) Hot Pluggable, Duplex LC, +3.3V 1310nm DFB-LD. Features

GPON SFP OLT Transceiver GNTP-4321S-B2CDA

RoHS compliant TX-1310/RX-1550 nm Single-mode Bi-directional SFP LC Simplex Connector DDM. Features

Singlemode 155Mbps Optical Transceiver SFP with MSA

155Mbps 850nm Multimode Optical Transceiver Small Form Pluggable (SFP)

SO-CSFP-100Base-BX20D-34-O2 -I

Multimode 1.25Gbps 850nm Optical Transceiver SFP with MSA

PT (2)-1W. OC-3 SR/IR-1 / STM S-1.1 SFP Transceiver

GLC-GE-100FX-LEG. 155Mbps SFP Transceiver

Fiber Channel 2.125Gbps Multimode Optical Transceiver SFP with MSA

LinkPower LPS LC MM 2630C/2630I. RoHS Compliant 1.25Gbps 850nm 550M Optical Transceiver

Product Specification Sheet

ES3112-3LCD Gbps SFP Optical Transceiver, 10KM Reach

EPON-OLT-20. OLT for IEEE 802.3ah-2004 PX Gbps Downstream and 1.25Gbps Upstream

SFP Module DB1310-SFP-SC.S20 DB1550-SFP-SC.S20. Features. Applications. Ordering information

AXFT Mbps~155Mbps Single Fiber Bi-directional SFP, ONU Transceiver

1.25Gbps SFP Optical Transceiver, 80KM Reach

155Mbps Single-mode 1310nm, SFP Transceiver

Singlemode 1.25Gbps Optical Transceiver SFP with MSA

125Mbps~155Mbps Multimode 850nm, SFP Transceiver

RoHS Compliant SFP Transceiver for ATM, SONET OC-3/SDH STM-1 with Digital Diagnostic Monitoring Function

AXGE Gbps Single-mode 1310nm, SFP Transceiver

Single Fiber 1.25Gbps Bi-directional Optical Transceiver SFP with Digital Diagnostics

DATASHEET 4.1. SFP, 100Mbps-2.7Gbps, Multirate, 1310nm, SM, DDM, 8dB, 2km, ind.temp.

SFP CWDM 1.25G nm Single mode Optical Transceiver

RoHS Compliant SFP Transceiver for SONET OC-48/SDH STM-16 with Digital Diagnostic Monitoring Function

SDH STM-1/SONET OC-3 SFP Transceiver With Digital Diagnostic Function. Applications: Features: Product Description

Singlemode 155Mbps Optical Transceiver SFP with Digital Diagnostic

SPM-3102WG / SPM-3102BWG / SPM-3102AWG (RoHS Compliant) 3.3V / 1310 nm / 125 Mbps Digital Diagnostic LC SFP MULTI-MODE TRANSCEIVER

SPL EBX-IDFM SPL EBX-IDFM

10Gbps 1270/1330nm SFP+ BIDI TRx 40km

LinkPower LPS SM BIDI 2612TC/2612TI & 2613RC/2613RI SC. RoHS Compliant 1.25G 1310/1550nm & 1550/1310nm 20km Transceivers

SFP 4.25G 850nm Multi mode Optical Transceiver

GLC-SX-MM-LEG. 1.25Gbps SFP Transceiver

1.25Gbps Single Fiber Bi-directional SFP, ONU Transceiver

JD061A-C. 1.25Gbps SFP Transceiver

SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

Multimode 155Mbps Optical Transceiver SFP with Digital Diagnostic

BO05C13610 SFP 1.25G 1310nm 10KM RoHS Compliant Optical Transceiver

SFP-1000BASE-LX-LEG. 1.25Gbps SFP Transceiver

Regulatory Compliance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge to the enclosure Electromagnetic Interference (EMI)

SO-SFP-10GE-LR20-I. SFP+, 10GBase-LR, 1310nm, SM, DDM, 11.4dB, 20km ind.temp. OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

GLC-LH-SM-TX. Product Features. Applications. General. Cisco Compatible 1000BASE-LX/LH SFP TurboX

UK - SFP MONOMODO 20 KM 1310 NM. DTS3112L - C(D)

DATASHEET 4.3. SFP+, 10GBase-LR, 1310nm, SM, DDM, 70km, RX sensitivity -22 dbm, Ind.temp.

SO-SFP-1000BASE-ZXD-I

BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

GLC-LH-SM-LEG-5PK. 1.25Gbps SFP Transceiver

10Gbps 1330/1270nm SFP+ BIDI TRx 80km

PT (2)-1W(+) GbE 1000Base-LX 10 km SFP Transceiver

APSB53123xxL20. Product Features. Applications. General. 1.25Gb/s BiDi SFP Transceiver

DS10-F007. Datasheet. Initial Date R&D Dept. GH Zheng. OE OFD6xx418 Written Team. PN OFD6xx418 Description XFP, DWDM 80KM

PRODUCT FEATURES APPLICATIONS. Pin Assignment: 1 Gigabit Long-Wavelength SFP Transceiver SFP-SX-MM

SNR-SFP-LX 1.25Gbps. Features. Applications. Product Description

RoHS Compliant Small Form Factor Pluggable Transceiver for Gigabit Ethernet and Fiber Channel

Transcription:

Features Up to 155Mbps data-rate GP-1303-02C(D) 155Mbps SFP Optical Transceiver, 2km Reach 1310nm FP(LED)laser and PIN photodetector for 2km transmission with MMF Compliant with SFP MSA and SFF-8472 with duplex LC receptacle Digital Diagnostic Monitoring: Internal Calibration or External Calibration Compatible with RoHS +3.3V single power supply Operating case temperature: Standard : 0 to +70 C Applications SDH STM-1, I-1 Sonet OC-3,SR1 Fast Ethernet Other Optical Links Description The SFP transceivers are high performance, cost effective modules supporting 155Mbps data-rate and 2km transmission distance with MMF. The transceiver consists of three sections: a FP laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements. The transceivers are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For further information, please refer to SFP MSA. Address: The West.2F Chuang Ye Yinzhang Bldg. Keji C.Road 1st. Page 1 of 9

TD+/- TxFault TxDis LD Driver LD LOS RD+/- Post Amp PIN+TIA SCL SDA EEPROM MCU ADC/DAC Vcc Temp Absolute Maximum Ratings Table 1 - Absolute Maximum Ratings Parameter Symbol Min Max Unit Supply Voltage Vcc -0.5 4.5 V Storage Temperature Ts -40 +85 C Operating Humidity - 5 85 % Recommended Operating Conditions Table 2 - Recommended Operating Conditions Parameter Symbol Min Typical Max Unit Operating Case Temperature Standard Tc 0 +70 C Power Supply Voltage Vcc 3.13 3.3 3.47 V Power Supply Current Icc 300 ma Data Rate 155 Mbps Address: The West.2F Chuang Ye Yinzhang Bldg. Keji C.Road 1st. Page 2 of 9

Optical and Electrical Characteristics GP-1303-02C(D): (FP(LED) and PIN, 1310nm, 2km Reach) Table 3 - Optical and Electrical Characteristics Parameter Symbol Min Typical Max Unit Notes Transmitter Centre Wavelength λc 1260 1310 1360 nm Spectral Width (RMS) λ 4 nm Average Output Power Pout -20-14 dbm 1 Extinction Ratio ER 9 16 db Data Input Swing Differential V IN 300 1860 mv 2 Input Differential Impedance Z IN 90 100 110 Ω TX Disable TX Fault Disable 2.0 Vcc V Enable 0 0.8 V Fault 2.0 Vcc V Normal 0 0.8 V Receiver Centre Wavelength λc 1260 1580 nm Receiver Sensitivity -31 dbm 3 Receiver Overload 0 dbm 3 LOS De-Assert LOS D -32 dbm LOS Assert LOS A -45 dbm LOS Hysteresis 1 4 db Data Output Swing Differential Vout 400 1800 mv 4 High 2.0 Vcc V LOS Low 0 0.8 V Notes: 1. The optical power is launched into SMF. 2. PECL input, internally AC-coupled and terminated. 3. Measured with a PRBS 2 23-1 test pattern @155Mbps, BER 1 10-10. 4. Internally AC-coupled. Address: The West.2F Chuang Ye Yinzhang Bldg. Keji C.Road 1st. Page 3 of 9

Timing and Electrical Table 4 - Timing and Electrical Parameter Symbol Min Typical Max Unit Tx Disable Negate Time t_on 1 ms Tx Disable Assert Time t_off 10 µs Time To Initialize, including Reset of Tx Fault t_init 300 ms Tx Fault Assert Time t_fault 100 µs Tx Disable To Reset t_reset 10 µs LOS Assert Time t_loss_on 100 µs LOS De-assert Time t_loss_off 100 µs Serial ID Clock Rate f_serial_clock 400 KHz MOD_DEF (0:2)-High V H 2 Vcc V MOD_DEF (0:2)-Low V L 0.8 V Diagnostics Table 5 Diagnostics Specification Parameter Range Unit Accuracy Calibration Temperature 0 to +70-40 to +85 C ±3 C Internal / External Voltage 3.0 to 3.6 V ±3% Internal / External Bias Current 0 to 100 ma ±10% Internal / External TX Power -18 to -14 dbm ±3dB Internal / External RX Power -30 to 0 dbm ±3dB Internal / External Address: The West.2F Chuang Ye Yinzhang Bldg. Keji C.Road 1st. Page 4 of 9

Digital Diagnostic Memory Map The transceivers provide serial ID memory contents and diagnostic information about the present operating conditions by the 2-wire serial interface (SCL, SDA). The diagnostic information with internal calibration or external calibration all are implemented, including received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring. The digital diagnostic memory map specific data field defines as following. Address: The West.2F Chuang Ye Yinzhang Bldg. Keji C.Road 1st. Page 5 of 9

Pin Definitions Pin Diagram Address: The West.2F Chuang Ye Yinzhang Bldg. Keji C.Road 1st. Page 6 of 9

Pin Descriptions Pin Signal Name Description Plug Seq. Notes 1 V EET Transmitter Ground 1 2 TX FAULT Transmitter Fault Indication 3 Note 1 3 TX DISABLE Transmitter Disable 3 Note 2 4 MOD_DEF(2) SDA Serial Data Signal 3 Note 3 5 MOD_DEF(1) SCL Serial Clock Signal 3 Note 3 6 MOD_DEF(0) TTL Low 3 Note 3 7 Rate Select Not Connected 3 8 LOS Loss of Signal 3 Note 4 9 V EER Receiver ground 1 10 V EER Receiver ground 1 11 V EER Receiver ground 1 12 RD- Inv. Received Data Out 3 Note 5 13 RD+ Received Data Out 3 Note 5 14 V EER Receiver ground 1 15 V CCR Receiver Power Supply 2 16 V CCT Transmitter Power Supply 2 17 V EET Transmitter Ground 1 18 TD+ Transmit Data In 3 Note 6 19 TD- Inv. Transmit Data In 3 Note 6 20 V EET Transmitter Ground 1 Notes: Plug Seq.: Pin engagement sequence during hot plugging. 1) TX Fault is an open collector output, which should be pulled up with a 4.7k~10kΩ resistor on the host board to a voltage between 2.0V and Vcc+0.3V. Logic 0 indicates normal operation; Logic 1 indicates a laser fault of some kind. In the low state, the output will be pulled to less than 0.8V. 2) TX Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7k~10kΩ resistor. Its states are: Low (0 to 0.8V): Transmitter on (>0.8V, < 2.0V): Undefined High (2.0 to 3.465V): Transmitter Disabled Open: Transmitter Disabled 3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7k~10kΩ resistor on the host board. The pull-up voltage shall be VccT or VccR. Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID 4) LOS is an open collector output, which should be pulled up with a 4.7k~10kΩ resistor. Pull up voltage between 2.0V and Vcc+0.3V. Logic 1 indicates loss of signal; Logic 0 indicates normal operation. In the low state, the output will be pulled to less than 0.8V. 5) RD-/+: These are the differential receiver outputs. They are internally AC-coupled 100 differential lines which should be terminated with 100Ω (differential) at the user SERDES. 6) TD-/+: These are the differential transmitter inputs. They are internally AC-coupled, differential lines with 100Ω differential termination inside the module. Address: The West.2F Chuang Ye Yinzhang Bldg. Keji C.Road 1st. Page 7 of 9

Recommended Interface Circuit Address: The West.2F Chuang Ye Yinzhang Bldg. Keji C.Road 1st. Page 8 of 9

Mechanical Dimensions Ordering information Part Number Product Description GP-1303-02C 1310nm, 155Mbps, 2km, 0ºC ~ +70ºC GP-1303-02CD 1310nm, 155Mbps, 2km, 0ºC ~ +70ºC, With Digital Diagnostic Monitoring E-mail: sales@gigalight.com.cn Web : http://www.gigalight.com.cn Address: The West.2F Chuang Ye Yinzhang Bldg. Keji C.Road 1st. Page 9 of 9