155Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

Similar documents
GPB-5303x-L2x(D) 155Mbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

622Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

622Mbps SFP Optical Transceiver, 40km Reach FS-622M-A40

SFP M~2.67Gbps SFP Optical Transceiver, 300m Reach

2.67Gbps CWDM SFP Optical Transceiver, 40km Reach GPC-xx48-04X(D)

1G SFP CWDM nm 80km Optical Transceivers

GPB-4324x-L4x(D) 1.25Gbps SFP Bi-Directional Transceiver, 40km Reach 1490nm TX / 1310 nm RX

1.25Gbps CWDM SFP Optical Transceiver, 80km Reach SFP-7080-Cxx

1.25Gbps SFP Optical Transceiver, 20km Reach GP L2x(D)

SNS SFP-GDCWXD-XX* 1.25 Gbps 80 km CWDM SFP Transceiver

1.25Gbps SFP Optical Transceiver, 550m Reach EP-8524-S5x(D)

1.25Gbps CWDM SFP Optical Transceiver, 40km Reach EPC-xx24-04C(D)

GPBC-xxxx24L-04CD 1.25Gbps SFP CWDM Bi-Di Single Fiber Transceiver, 40km Reach

AC05-A13L6-02 (-DD) 155Mbps SFP Optical Transceiver, 2km Reach

GLC-SX-MMD (1000BASE-SX SFP) Datasheet

GP C(D) 155Mbps SFP Optical Transceiver, 2km Reach

GLC LH SM. 1.25Gbps SFP Optical Transceiver, 20km Reach

GP-8524-S5x(D) 1.25Gbps SFP Optical Transceiver, 550m Reach

CWDM SFP 1.25G 40KM LC Duplex

SFP BIDI 2.488Gbps 20KM 1550nm TX/1310nm RX

GP-5524-L8x(D) 1.25Gbps SFP Optical Transceiver, 80km Reach

AOP-324-R20(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

XSB531-20xx Gbps SFP Bi-Directional Transceiver, 20 km Reach, 1550 nm TX/1310 nm RX. Features. Applications. Description

GP-3124-L2x(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

HT201-24D083M Gbps 850nm SFP Optical Transceiver, 550m Reach

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

XSS311-20LY. 1.25Gbps SFP Optical Transceiver, 20km Reach. Features. Applications. Description

3CP-485L1MN-SX 1.25Gbps SFP Optical Transceiver, 550m Reach

SFP-7020-WB 1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1310nm TX / 1550 nm RX CFORTH-SFP-35-20S

GPB-5324L-L8CD 1.25Gbps SFP Bi-Directional Transceiver, 80km Reach 1550nm TX / 1310 nm RX

1.25Gbps SFP Optical Transceiver, 550m Reach

1.25Gbps SFP Optical Transceiver, 550m Reach

FSPC-xx12-40D. 1.25G SFP CWDM 1470nm~1610nm 40km Optical Transceiver

MGS-MM MODULO GBIC SFP 500M 4.25GBPS LC MM 850NM VCSEL PIN TRANSCEIVERS

SFP Optical Transceivers

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

SGMII SFP 125Mbps 1310nm MMF 2KM SLSG D

GPH-3102-L1C(D) 100BASE-LX Spring-Latch SFP Transceiver, 10km Reach

GNTP-4321S-C2CDA GPON SFP OLT Transceiver

GPD-XX24-08CD GIGALIGHT DWDM SFP Optical Transceiver

EPON OLT 1.25Gbps 1000Base-PX20 Tx1490/Rx1310nm DDMI SLEP-1143-P

GDETP-XX21S-2CD DWDM EPON OLT SFP Transceiver

GPON SFP OLT Transceiver GNTP-4321S-B2CDA

GPON ONU SFF 2X10 GNUF-3412S-B2CDA

Product Specification Sheet

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

GLC-GE-100FX-LEG. 155Mbps SFP Transceiver

RoHS compliant TX-1310/RX-1550 nm Single-mode Bi-directional SFP LC Simplex Connector DDM. Features

6Gbps SFP+ Optical Transceiver,10 Km (OP3B10D ) Hot Pluggable, Duplex LC, +3.3V 1310nm DFB-LD. Features

SFP Module DB1310-SFP-SC.S20 DB1550-SFP-SC.S20. Features. Applications. Ordering information

EPON-OLT-20. OLT for IEEE 802.3ah-2004 PX Gbps Downstream and 1.25Gbps Upstream

SFP CWDM 1.25G nm Single mode Optical Transceiver

SFP 4.25G 850nm Multi mode Optical Transceiver

Singlemode 155Mbps Optical Transceiver SFP with MSA

SO-CSFP-100Base-BX20D-34-O2 -I

1.25Gbps SFP Optical Transceiver, 80KM Reach

GIGALIGHT 80km 1550nm SFP+ Optical Transceiver GPP ZRC

SPL EBX-IDFM SPL EBX-IDFM

10G SFP+ ER 1550nm 40km Optical Transceiver GPP ERC

ES3112-3LCD Gbps SFP Optical Transceiver, 10KM Reach

GPD-xx48-12CD 2.67G DWDM SFP 120km Optical Transceiver

GPD-XX48-08CD GIGALIGHT DWDM 2.67G SFP Optical Transceiver

PT (2)-1W. OC-3 SR/IR-1 / STM S-1.1 SFP Transceiver

GIGALIGHT 80km DWDM XFP Optical Transceiver GXD-XX192-08C

155Mbps 850nm Multimode Optical Transceiver Small Form Pluggable (SFP)

SDH STM-1/SONET OC-3 SFP Transceiver With Digital Diagnostic Function. Applications: Features: Product Description

GLC-LH-SM-TX. Product Features. Applications. General. Cisco Compatible 1000BASE-LX/LH SFP TurboX

Regulatory Compliance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge to the enclosure Electromagnetic Interference (EMI)

BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

SFP-1000BASE-LX-LEG. 1.25Gbps SFP Transceiver

GLC-SX-MM-LEG. 1.25Gbps SFP Transceiver

GLC-LH-SM-LEG-5PK. 1.25Gbps SFP Transceiver

OCTECH 1.25Gbps SFP Transceiver

BO05C13610 SFP 1.25G 1310nm 10KM RoHS Compliant Optical Transceiver

JD061A-C. 1.25Gbps SFP Transceiver

DATASHEET 4.1. SFP, 100Mbps-2.7Gbps, Multirate, 1310nm, SM, DDM, 8dB, 2km, ind.temp.

OP-MP115L1SD-120. Product Features. Applications. General. OC-3 120km RoHS Compliant Pluggable SFP Transceiver

RoHS Compliant SFP Transceiver for SONET OC-48/SDH STM-16 with Digital Diagnostic Monitoring Function

2 Mb/s IEEE C37.94 Multi-Mode Transceiver

LinkPower LPS LC MM 2630C/2630I. RoHS Compliant 1.25Gbps 850nm 550M Optical Transceiver

LEG. 10Gbps SFP+ Transceiver

DWDM SFP+ Series DWDM EML

Product Specification Sheet

OCTECH 1.25Gbps SFP Transceiver

EMPOWERFIBER 70km~80km 1550nm SFP+ Optical Transceiver EPP ZRC

SFP+ Series SFP-10G-SR

1.25Gb/s SFP Transceiver P/N: MO-C-S31123CDL20. Product Features. Applications. General. Regulatory Compliance. Up to 1.

SFP+ BIDI Series JB1270-SFP-LC.S40. Features. Applications. Ordering information

RoHS Compliant SFP Transceiver for ATM, SONET OC-3/SDH STM-1 with Digital Diagnostic Monitoring Function

STM-1/OC-3 Bidirectional SFP Transceiver With Digital Diagnostic Function. Features: Applications: Product Description

APSB53123xxL20. Product Features. Applications. General. 1.25Gb/s BiDi SFP Transceiver

SFP Dual LC 1.25G SMF 20Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

SFP+-DWDM-xx-80D. 10Gbps DWDM SFP+ Optical Transceiver, 80km Reach

GBP-XXXX192-L2C 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

Fiber Channel 2.125Gbps Multimode Optical Transceiver SFP with MSA

SFP Series IOLS-1348-XXXX. 4.25Gbps up to 30 km transmission. version 0.1 FEATURES PRODUCT DESCRIPTION

SFP Series. Features. Applications. Ordering information. Single-Mode 155Mbps SC Single-Fiber SFP Transceiver RoHS6 Compliant

155Mbps Single-mode 1310nm, SFP Transceiver

4.25Gbps SFP Transceiver

Transcription:

155Mbps SFP Optical Transceiver, 40km Reach GP-3103- L4x(D) Features Up to 155Mbps data-rate 1310nm FP laser and PIN photo detector for 40km transmission Compliant with SFP MSA and SFF-8472 with duplex LC receptacle Digital Diagnostic Monitoring: Internal Calibration or External Calibration Compatible with RoHS +3.3V single power supply Operating case temperature: Standard : 0 to +70 C Industrial : -40 to +85 C Applications SDH STM-1, S-1.1,L-1.1, L-1.2 SONET OC-3 IR1,LR1,LR2 Other optical links Description The SFP transceivers are high performance, cost effective modules supporting 155Mbps data-rate and 40km transmission distance with SMF. The transceiver consists of three sections: a FP laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements. The transceivers are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For further information, please refer to SFP MSA. Address: 5F, Main Building SheKou Technology Building, Page 1 of 10

Module Block Diagram TD+/- TxFault TxDis LD Driver LD LOS RD+/- Post Amp PIN+TIA SCL SDA EEPROM MCU ADC/DAC Vcc Temp Absolute Maximum Ratings Table 1 - Absolute Maximum Ratings Parameter Symbol Min Max Unit Supply Voltage Vcc -0.5 4.5 V Storage Temperature Ts -40 +85 C Operating Humidity - 5 85 % Recommended Operating Conditions Table 2 - Recommended Operating Conditions Parameter Symbol Min Typical Max Unit Operating Case Temperature Standard 0 +70 C Tc Industrial -40 +85 C Power Supply Voltage Vcc 3.13 3.3 3.47 V Power Supply Current Icc 300 ma Data Rate 155 Mbps Address: 5F, Main Building SheKou Technology Building, Page 2 of 10

Optical and Electrical Characteristics Table 3 - Optical and Electrical Characteristics Parameter Symbol Min Typical Max Unit Notes Transmitter Centre Wavelength λc 1260 1310 1360 nm Spectral Width (RMS) σ 4 nm Average Output Power Pout -5 0 dbm 1 Extinction Ratio ER 9 db Optical Rise/Fall Time t r/t f 1.3 ns Data Input Swing Differential VIN 300 1860 mv 2 Input Differential Impedance Z IN 90 100 110 Ω TX Disable TX Fault Disable 2.0 Vcc V Enable 0 0.8 V Fault 2.0 Vcc V Normal 0 0.8 V Receiver Centre Wavelength λc 1260 1580 nm Receiver Sensitivity -34 dbm 3 Receiver Overload -3 dbm 3 LOS De-Assert LOS D -36 dbm LOS Assert LOS A -45 dbm LOS Hysteresis 1 4 db Data Output Swing Differential Vout 400 1800 mv 4 LOS Notes: 1. The optical power is launched into SMF. 2. PECL input, internally AC-coupled and terminated. 3. Measured with a PRBS 2 23-1 test pattern @155Mbps, BER 1 10-10. 4. Internally AC-coupled. High 2.0 Vcc V Low 0.8 V Address: 5F, Main Building SheKou Technology Building, Page 3 of 10

Timing and Electrical Table 4 - Timing and Electrical Parameter Symbol Min Typical Max Unit Tx Disable Negate Time t_on 1 ms Tx Disable Assert Time t_off 10 µs Time To Initialize, including Reset of Tx Fault t_init 300 ms Tx Fault Assert Time t_fault 100 µs Tx Disable To Reset t_reset 10 µs LOS Assert Time t_loss_on 100 µs LOS De-assert Time t_loss_off 100 µs Serial ID Clock Rate f_serial_clock 400 KHz MOD_DEF (0:2)-High V H 2 Vcc V MOD_DEF (0:2)-Low V L 0.8 V Diagnostics Table 5 Diagnostics Specification Parameter Range Unit Accuracy Calibration Temperature 0 to +70-40 to +85 C ±3 C Internal / External Voltage 3.0 to 3.6 V ±3% Internal / External Bias Current 0 to 100 ma ±10% Internal / External TX Power -5 to 0 dbm ±3dB Internal / External RX Power -28 to -3 dbm ±3dB Internal / External Address: 5F, Main Building SheKou Technology Building, Page 4 of 10

Digital Diagnostic Memory Map The transceivers provide serial ID memory contents and diagnostic information about the present operating conditions by the 2-wire serial interface (SCL, SDA). The diagnostic information with internal calibration or external calibration all are implemented, including received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring. The digital diagnostic memory map specific data field defines as following. Address: 5F, Main Building SheKou Technology Building, Page 5 of 10

Pin Definitions Pin Diagram Address: 5F, Main Building SheKou Technology Building, Page 6 of 10

Pin Descriptions Pin Signal Name Description Plug Seq. Notes 1 V EET Transmitter Ground 1 2 TX FAULT Transmitter Fault Indication 3 Note 1 3 TX DISABLE Transmitter Disable 3 Note 2 4 MOD_DEF(2) SDA Serial Data Signal 3 Note 3 5 MOD_DEF(1) SCL Serial Clock Signal 3 Note 3 6 MOD_DEF(0) TTL Low 3 Note 3 7 Rate Select Not Connected 3 8 LOS Loss of Signal 3 Note 4 9 V EER Receiver ground 1 10 VEER Receiver ground 1 11 V EER Receiver ground 1 12 RD- Inv. Received Data Out 3 Note 5 13 RD+ Received Data Out 3 Note 5 14 V EER Receiver ground 1 15 V CCR Receiver Power Supply 2 16 V CCT Transmitter Power Supply 2 17 V EET Transmitter Ground 1 18 TD+ Transmit Data In 3 Note 6 19 TD- Inv. Transmit Data In 3 Note 6 20 V EET Transmitter Ground 1 Notes: Plug Seq.: Pin engagement sequence during hot plugging. 1) TX Fault is an open collector output, which should be pulled up with a 4.7k~10kΩ resistor on the host board to a voltage between 2.0V and Vcc+0.3V. Logic 0 indicates normal operation; Logic 1 indicates a laser fault of some kind. In the low state, the output will be pulled to less than 0.8V. 2) TX Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7k~10kΩ resistor. Its states are: Low (0 to 0.8V): Transmitter on (>0.8V, < 2.0V): Undefined High (2.0 to 3.465V): Transmitter Disabled Open: Transmitter Disabled 3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7k~10kΩ resistor on the host board. The pull-up voltage shall be VccT or VccR. Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID 4) LOS is an open collector output, which should be pulled up with a 4.7k~10kΩ resistor. Pull up voltage between 2.0V and Vcc+0.3V. Logic 1 indicates loss of signal; Logic 0 indicates normal operation. In the low state, the output will be pulled to less than 0.8V. 5) RD-/+: These are the differential receiver outputs. They are internally AC-coupled 100 differential lines which should be terminated with 100Ω (differential) at the user SERDES. 6) TD-/+: These are the differential transmitter inputs. They are internally AC-coupled, differential lines with 100Ω differential termination inside the module. Address: 5F, Main Building SheKou Technology Building, Page 7 of 10

Recommended Interface Circuit Address: 5F, Main Building SheKou Technology Building, Page 8 of 10

Mechanical Dimensions Regulatory Compliance Gigalight SFP transceiver is designed to be Class I Laser safety compliant and is certified per the following standards Laser Safety Product Safety Feature Agency Standard FDA BST CDRH 21 CFR 1040 annd Laser Notice No. 50 EN 60825-1:2007 EN 60825-2:2004 EN 60950-1:2006 Certificate / Comments 1120295-000 BT0905142001 Environmental protection SGS RoHS Directive 2002/95/EC GZ0902007478/CHEM EMC CCIC EN 55022:2006+A1:2007 EN 55024:1998+A1:2001+A2:2003 CTE09020023 Address: 5F, Main Building SheKou Technology Building, Page 9 of 10

Ordering information Part Number Product Description GP-3103-L4C 1310nm, 155Mbps, 40km, 0ºC ~ +70ºC GP-3103-L4CD 1310nm, 155Mbps, 40km, 0ºC ~ +70ºC, With Digital Diagnostic Monitoring GP-3103-L4T 1310nm, 155Mbps, 40km, -40ºC ~ +85ºC GP-3103-L4TD 1310nm, 155Mbps, 40km, -40ºC ~ +85ºC, With Digital Diagnostic Monitoring References 1. Small Form Factor Pluggable (SFP) Transceiver Multi-Source Agreement (MSA),September 2000. 2. Telcordia GR-253-CORE and ITU-T G.957 Specifications. Important Notice Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by GIGALIGHT before they become applicable to any particular order or contract. In accordance with the GIGALIGHT policy of continuous improvement specifications may change without notice. The publication of information in this data sheet does not imply freedom from patent or other protective rights of GIGALIGHT or others. Further details are available from any GIGALIGHT sales representative. sales@gigalight.com.cn Address: 5F, Main Building SheKou Technology Building, Page 10 of 10