Figure 1. Two- and Three-phase MagneX Interrupter.

Similar documents
Two- and three-phase MagneX interrupter

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

VariSTAR Type AZU heavy-duty distribution-class under-oil MOV surge arrester

Distribution/Substation Transformer

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Three-Phase VFI Padmount Transformers. Double Duty in a Single Package. www. ElectricalPartManuals. com

Eaton s Cooper Power Series DEADFRONT ARRESTERS

Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

35 kv Class M.O.V.E. DirectConnect elbow arrester

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

Transformer Protection

Distribution Transformers

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Comparison of recloser and breaker standards

VariSTAR Type AZL heavy-duty distribution-class MOV arrester

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

TABLE OF CONTENT

Mica Element Support High Current Interruption Element. Welded Element Joints

Course 11 Distribution Transformer Applications Instructor: David R. Smith, PE Due: April 24, 2017 (EV), April 25, 2017 (LC)

NOVA-TS Triple-Single Recloser and Form 5/TS Control Frequently Asked Questions

Protection of Electrical Networks. Christophe Prévé

POSI-BREAK Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

This document covers common questions concerning the design of an effectively grounded system.

Howard Smart Transformer Specification Guide

Electrical Description

Short-Circuit Current Calculations

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

UltraSIL Polymer-Housed VariSTAR Normal-Duty, Heavy-Duty and Riser Pole Distribution-Class Arresters

Table of Contents. Introduction... 1

Section 2 Outdoor Voltage Transformers

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

Variable Transformers Product Design & Engineering Data

BUCK-BOOST TRANSFORMERS

R Distribution Transformers. Mineral Oil-Immersed, Self-Cooled, 60 Hertz Voltages and Connections. Reference Data

Protective Relays Digitrip 3000

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

Article 225: Outside Branch Circuits And Feeders

SECTION 5 TRANSFORMERS

Busbars and lines are important elements

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

Protective Relaying for DER

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

Short Circuit Current Calculations

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Unit 29 Three-Phase Transformers

E N G I N E E R I N G M A N U A L

Certificate of Compliance

Transformer Protection Principles

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

ARC FLASH PPE GUIDELINES FOR INDUSTRIAL POWER SYSTEMS

HPS Universal BUCK-BOOST TRANSFORMERS

Note: The let-through of the protective device must be equal to or less than the short-circuit current rating of the component being protected.

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

PACSystems* RX3i IC695MDL765

How to maximize reliability using an alternative distribution system for critical loads

Phase and neutral overcurrent protection

Effective February 2017 Supersedes January 2012 (CP1122)

Rarely used, problems with unbalanced loads.

Warehouse Stock Transformers

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering)

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

Surge Arresters. VariSTAR Type AZS Normal Duty Distribution Class MOV Arrester

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

7. INSPECTION AND TEST PROCEDURES

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

INTERIM ARRANGEMENTS FOR GRID TIED DISTRIBUTED ENERGY RESOURCES. Technical Requirements for Grid-Tied DERs

Specifications. S&C BankGuard Plus Controls. For Substation Capacitor Banks and Shunt Reactors. Conditions of Sale

Earth fault protection for isolated neutral systems with frequency converters

PHOENIX CONTACT

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

No. SSIEC-SEW SHINSUNG. Solid Insulation Eco Load Break Switch (SILO) SILO SERIES 15kV, 27kV 400A, 630A

BC145 SIGNAL ISOLATOR BOARD

Supplemental Motor Protection Devices Specifications

Tertiary Winding Design in wye-wye Connected Transformers Restricted Siemens Energy 2013 All rights reserved.

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

PHOENIX CONTACT

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

ET 51 - Electrician Theory Examination Marking Schedule

Application Note. Applicable Product: AC Drives

QUINT-PS/ 3AC/24DC/10

Supplemental Motor Protection Devices Specifications

8 Input/8 Output AC Block I/O Module

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell

www. ElectricalPartManuals. com Generator Differential Relay MD32G Rotating Machine Differential Relay

The Isolator/Surge Protector (ISP)

The Isolator/Surge Protector (ISP)

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

ELECTRICIAN S THEORY EXAMINATION 20 November 2010 QUESTION AND ANSWER BOOKLET

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

3Ø Short-Circuit Calculations

Transformer Questions & Answers

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Transcription:

Fusing Equipment Two- & Three-Phase MagneX Interrupter Electrical Apparatus 2-33 General The Cooper Power Systems MagneX Interrupter is an overcurrent protective device that protects distribution transformers from damaging overloads and secondary faults, and is also used for switching the transformer on or off. As a transformer protective device, the MagneX Interrupter combines safety and efficiency with economic operation. It is an integral assembly, which does not use a troublesome linkage or require calibration, making installation and operation fast and trouble free. The housing is made of an ultraviolet stabilized, high-strength, glass-filled thermoplastic material. The operating shaft is sealed against leakage with a double-viton O-ring seal. Electrical ratings TABLE 1 Voltage Ratings and Characteristics Figure 1. Two- and Three-phase MagneX Interrupter. Application kv Amps Impulse 1.2 x Microsecond Wave 1 60 Hz, 1 Minute Voltage Withstand Continuous Current Rating 42 Switching Load Currents 42 TABLE 2 Interrupting Rating Voltage RMS RMS kv-lg Symmetric Asymmetric (A) (A) (A) 8.3 20 4200 15.5 10 22 23.0 0 7 The three-phase MagneX Interrupter combines the functionality of three Bay-O-Net fuses and one threephase on/off loadbreak switch into one protective device. This allows transformer manufacturers more flexibility in application of the product and potentially reduces the space required to install the device on the transformer front plate. This product is ideal for three-phase pad-mounted transformer applications. The two-phase MagneX Interrupter is designed for single-phase applications where disconnecting both primary coil leads is desirable. This feature is ideal for two-bushing transformers, where a fault on either leg of the transformer may cause activation of the protective device. Secondary faults and overloads will trip the MagneX Interrupter open. However, the device can be reset once the condition is corrected. The MagneX Interrupter, in coordination with either an isolation link or current-limiting fuse, also clears primary faults. The MagneX Interrupter can also be used as a primary switch to disconnect the transformer windings not just the load. This eliminates core (no-load) losses on transformers not in service. Residual voltage problems associated with secondary breakers during banking of transformers are also eliminated. Three-Phase MagneX Interrupter Operation Figure 2 demonstrates the circuit diagram for the three-phase MagneX Interrupter with single-phase sense, single-phase trip. The three-phase MagneX Interrupter with single-phase sense, single-phase trip contains one sensors per phase. It reacts to fault currents on one phase and will cause tripping of that phase only. The MagneX Interrupter then can be reset via the single operating handle by opening all three phases and closing all phases back in simultaneously. Interrupter Chambers Ganged Trip Figure 2. Three-phase MagneX Interrupter, single-phase sense, single-phase trip. 0711 Supersedes 11/10 1

Two- & Three-Phase MagneX Interrupter Figure 3 demonstrates the circuit diagram for the three-phase MagneX Interrupter with single-phase sense, three-phase trip, containing one sensor in two of the three phases. This product should only be applied to delta-connected primary transformers, where any fault current flow in one phase will also flow in an adjacent phase. It reacts to fault currents on one phase and will cause tripping of all three phases. The MagneX Interrupter then can be reset via the single operating handle by opening all three phases and closing all phases back in simultaneously. The three-phase MagneX Interrupter with single-phase sense, three-phase trip should always be used in series with at least one backup current-limiting fuse in each of the three-phases. The backup current limiting fuses (see ELSP catalog section 2-) provide high-current interruption capability. Figure 4 shows the circuit diagram for the two-phase MagneX Interrupter. The two-phase MagneX Interrupter was specifically designed for singlephase, two bushing transformers, where disconnection of both bushings is desired following fault/overload detection. The MagneX Interrupter will react to a fault sensed in either leg of the transformer primary. Interruption takes place in both interruption chambers simultaneously, disconnecting both legs of the transformer from the circuit. Optional Handle Assemblies A standard handle, as shown in Figures 5, is typically used in overhead poletype transformers. It is also used in underground pad-mounted transformer applications. The MagneX Interrupter handle is reversible to enhance functionality and provide for optimal orientation of the handle in pad-mounted transformer applications. It is made of an ultraviolet stabilized high-strength, glass-filled thermoplastic material. The lower slotted portion of the handle is made of a flexible ultraviolet stabilized elastomeric material. The handle requires five pounds (2.27 kg) of force to operate manually. It allows flexibility for excessive force during operation. Interrupter Chambers Ganged Trip Interrupter Chambers Ganged Trip Figure 3. Three-phase MagneX Interrupter, single-phase sense three-phase trip. Figure 4. Two-phase MagneX Interrupter. OPTIONAL HANDLE ORIENTATION MOVEMENT SWING 2.15" (54.6 mm) Ø 2.1" (54 mm) 6.32" (160.6 mm) CONNECTION POINT FOR ISOLATION LINK (2 PHASE ONLY) OR ELSP (PARTIAL RANGE CURRENT-LIMITING) FUSE (2 OR 3 PHASE) 4." (111.7 mm) 2.97" (75.3 mm) 4.52" (114.8 mm) 3.75" (95.3 mm) 6.20" (157.5 mm) SNAP RING HANDLE NUT TANK WALL HANDLE SHOWN IN STANDARD ORIENTATION.19" (4.8 mm) GASKET 1.85" (46.9 mm) 6.52" (165.61 mm) 1.53" (38.9 mm) 13.11" (LENGTH OF 2 PHASE) (333 mm) 19.70" (LENGTH OF 3 PHASE) (0.4 mm).32" (8 mm) Figure 5. MagneX Interrupter assembly front/side/back views (with standard handle hardware kit). Note: Dimensions given are for reference only, inches (mm) 2

2-33 Installation The MagneX Interrupter is mounted under-oil on the primary side of the transformer. No special tools are required. The MagneX Interrupter assembly is mounted through the transformer wall. The incoming high voltage lead is connected first to the isolation link or to the current-limiting fuse and then to the MagneX Interrupter. The coil lead is then connected to the lower MagneX Interrupter connection point (See Figure 8). Refer to Installation Instructions S2-33-1 for details. CONNECTION POINT FOR ISOLATION LINK (2 PHASE ONLY) OR ELSP (PARTIAL RANGE CURRENT LIMITING) FUSE (2 OR 3 PHASE) [THE HIGH VOLTAGE LEAD (FROM BUSHING) IS CONNECTED TO THE OTHER END OF THE ISOLATION LINK OR ELSP FUSE] CONNECTION POINT BETWEEN MAGNEX AND CORE COIL OPTIONAL HANDLE ORIENTATION MOVEMENT SWING 4.52" (114.8 mm) 3.75" (95.3 mm) 6.20" (157.5 mm) HANDLE IN STANDARD OPEN POSITION HANDLE IN STANDARD CLOSED POSITION STANDARD HANDLE ORIENTATION MOVEMENT SWING Figure 6. Open/Closed handle positions (Standard positions shown). 2.25 (57 mm) Figure 7. Tank mounting hole detail. 1.125 (28.5 mm) 0.156 rad. (4 mm) Note: Exterior mounting surface extending 1 / 2 outward from the tank hole outer edge shall be flat and clear of surface obstructions. Figure 8. Lead connection points. Production Tests Tests are conducted in accordance with Cooper Power Systems requirements. % Physical Inspection % Electrically Tested to Meet Minimum Trip and Maximum Trip Clear TCC Curves Periodic Fluoroscopic Analysis (X-ray) Ordering Information The three-phase MagneX Interrupter is available in two design variations. The first is a single-phase sense, single-phase trip version, for wyeconnected transformers. This design is ideal for applications where customers desire fault sensing on one phase and tripping on that phase only. This option can be used with either an isolation link (recommended as a minimum) or backup current- limiting fuse. The second three-phase MagneX Interrupter design option is a singlephase sense, three-phase trip version, for delta connected transformers. This design is well suited for threephase delta connected transformer applications (this design should NOT be used on wye-connected transformer primaries). The three-phase MagneX Interrupter with single-phase sense, three-phase trip should always be used with backup current-limiting fusing. For three-phase delta primary connected transformers, use Table 3 to determine the correct MagneX Interrupter sensor size and the appropriate ELSP backup current-limiting fuse required for the application. Use Table 7 to determine the exact MagneX Interrupter catalog number. For three-phase wye primary connected transformers, use Table 4 to determine the correct MagneX Interrupter sensor size and the appropriate ELSP backup current-limiting fuse required for the application, or refer to Table 6 for the appropriate isolation link. Use Table 7 to determine the exact MagneX Interrupter catalog number. For the two-phase MagneX Interrupter, refer to Table 5 to determine the correct MagneX Interrupter sensor size for the application. Use Table 6 to determine the appropriate isolation link, or Table 9 to determine the appropriate ELSP backup currentlimiting fuse for the application. Use Table 7 to determine the exact MagneX Interrupter catalog number. Note: When ordering a MagneX Interrupter, the standard handle kit and hardware must be ordered separately. See Table 8 for the appropriate handle and hardware kit catalog number. 3

Two- & Three-Phase MagneX Interrupter TABLE 3 3-Phase MagneX Interrupter Recommendations for Transformers with Delta Connected Primary Windings (Single-Phase Sense, Three-Phase Trip) Transformer kva Rating Primary Voltage Assumed Minimum Impedance Recommended MagneX ELSP Rating without Emergency Overload 1.60 65 75 1.60 112.5 1. E25 125 4.16 1 2.00 E 1 225 3.00 E 1 0 3. E 165 1.60 75 1.60 65 112.5 1. 1 7.2-7.96 2.00 225 3.00 E25 0 3. E 125 0 4.00 E 1 1.60 75 1.60 112.5 1. 1 2.00 65 12-12.47 225 3.00 0 3. E25 0 4.00 E 7 5.75 E 1 1.60 75 1.60 112.5 1. 1 2.00 225 13.2 3.00 65 0 3. 0 4.00 E 7 5.75 E 125 0 5.75 E 1 4

2-33 TABLE 3 (Continued) 3-Phase MagneX Recommendations for Transformers with Delta Connected Primary Windings (Single-Phase Sense, Three-Phase Trip) Transformer kva Rating Primary Voltage Assumed Minimum Impedance Recommended MagneX ELSP Rating without Emergency Overload 1. 75 2.00 112.5 2.00 1 3.00 65 225 4.00 20 0 4.00 E25 0 4.00 E 7 5.75 E 0 5.75 E 12 5.75 E 1 1. 75 2.00 112.5 2.00 1 3.00 65 225 4.00 22 0 4.00 0 4.00 E25 7 5.75 E 0 5.75 E 12 5.75 E 125 Notes: MagneX Interrupter recommendations based on Minimum trip curves, and Maximum trip and clear curves, R2-91-2. Deration factor of 0.5% per degree C above ambient (25 C). Allowable loading greater than 1% for four hours in accordance with IEEE Std C57.91 1981 standard Guide for Loading Distribution Transformers, Table 6. MagneX/ELSP coordinations based on coordination requirements of single-phase sense, three-phase trip version MagneX interrupter. Proper coordination requires delta connected transformer primary. Proper protection requires that a backup current-limiting fuse be used in series with each MagneX interruption chamber. DO NOT USE AN ISOLATION LINK WITH THE THREE-PHASE MagneX Interrupter. Failure to use backup current-limiting fuse in series with the MagneX Interrupter can result in an unprotected phase. Backup current limiting fuse may be rated for line-to-neutral voltage, as the three-phase MagneX Interrupter is three-phase rated. Added backup protection can be achieved using phase-to-phase rated backup current-limiting fuse. 5

Two- & Three-Phase MagneX Interrupter TABLE 4 3-Phase MagneX Interrupter Recommendations for Transformers with WYE Connected Primary Windings (Single-Phase Sense, Single-Phase Trip) Transformer kva Rating Primary Voltage Assumed Minimum Impedance Recommended MagneX ELSP Rating without Emergency Overload 1.60 75 1.60 112.5 1. E25 4.16 1 2.00 E 125 225 3.00 E 1 0 3. E 1 1.60 75 1.60 112.5 1. 1 7.2-7.96 2.00 225 3.00 E25 0 3. E 0 4.00 E 1 1.60 75 1.60 112.5 1. 1 2.00 12-12.47 225 3.00 0 3. E25 0 4.00 E 7 5.75 E 125 1.60 75 1.60 112.5 1. 1 2.00 13.2 225 3.00 0 3. 0 4.00 E 7 5.75 E 1.60 75 1.60 112.5 1. 1 2.00 225 20.8 3.00 0 3. E25 0 4.00 E25 7 5.75 E 0 5.75 E 1.60 75 1.60 112.5 1. 1 2.00 225 22.86 3.00 0 3. 0 4.00 E 7 5.75 E 0 5.75 E 125 6

2-33 TABLE 4 (Continued) 3-Phase MagneX Interrupter Recommendations for Transformers with WYE Connected Primary Windings (Single-Phase Sense, Single-Phase Trip) Transformer kva Rating Primary Voltage Assumed Minimum Impedance Recommended MagneX ELSP Rating without Emergency Overload 1.60 75 1.60 112.5 1. 1 2.00 225 3.00 0 24.94 3. 0 4.00 7 5.75 E25 0 5.75 E 10 5.75 E 125 2000 5.75 E 1 1.60 75 1.60 112.5 1. 1 2.00 225 3.00 0 27.6 3. 0 4.00 7 5.75 E25 0 5.75 E 10 5.75 E 2000 5.75 E 125 1.60 75 1.60 112.5 1. 1 2.00 225 3.00 0 3. 34.5 0 4.00 7 5.75 0 5.75 E25 10 5.75 E 2000 5.75 E 125 20 5.75 E 125 Notes: Line-to-neutral rated fuses can be used on Gnd Y-Gnd Y transformers with less than % delta loading MagneX Interrupter recommendations based on Minimum trip curves, and Maximum trip and clear curves, R2-91-310. Deration factor of 0.5% per degree C above ambient (25 C). Allowable loading greater than 1% for four hours in accordance with IEEE Std C57.91 1981 standard Guide for Loading Distribution Transformers, Table 6. MagneX/ELSP coordinations based on coordination requirements of single-phase sense, single-phase trip version of the MagneX interrupter. Proper coordination requires WYE connected transformer primary. Backup current limiting fuses may be rated for line-to-neutral voltage for Gnd Y-Gnd Y connections, with less than % delta loading ONLY. If this guideline is not followed, recovery voltages exceeding the backup current-limiting fuse may cause fuse failure. In all other cases, voltage rating of the backup current-limiting fuse must be line-to-line rated. Note: The MagneX Interrupter recommendations above 22 kv are for Gnd Y-Gnd Y transformers with less than % delta loading ONLY. 7

Two- & Three-Phase MagneX Interrupter TABLE 5 Two-Phase MagneX Interrupter Recommendations Primary Voltage kv kva/kv 2.4 4.16-4.8 6.9-8.0 12.00-14.4 19.92 10 15 25 37.5 75 E E E25 167 E E - E E Notes: Recommendations are based on: Minimum trip curves, and Maximum trip and clear curves, R2-91-310. Deration factor of 0.5% per C above 25 C. Allowable loading greater than 1% for four hours in accordance with IEEE Std C57.91 1981 standard, Guide for Loading Distribution Transformers, Table 6. TABLE 6 Isolation Link MagneX Interrupter Correlation Chart E25 E E E Number Isolation Link 36373B01 36373B08 36373B02 36373B09 36373B10 36373B03 36373B03 36373B05 36373B05 36373B05 TABLE 7 Hardware Kit Description Standard Handle Kit & Hardware, w/o Emergency Overload Hotstick Adapter Catalog Number 3638535A09 3639585A01 Two- and three-phase MagneX Interrupter is not yet available with emergency overload feature. TABLE 8 MagneX Interrupter Significant Digit Catalog Number System Example: To order a three-phase MagneX Interrupter with single-phase sense, three-phase trip, with float and sensor, the catalog number would be MX3BN1MD Standard Options Digits: 1 2 3 4 5 6 7 8 9 10 11 M X 3 B N 1 M D E 1 2 Product MagneX Phases 2-Two 3-Three Indicator B-w/o Indicator Overload N-Non EO Trip Type M-Multi-Phase Trip* S-Single-Phase Trip** NOTE: For 2-Phase MagneX must be M * If M, only select D for System Connection (digit 8) **If S, only select Y for System Connection (digit 8) Float 1-w/Float 2-w/o Float System Connection D-Delta Y-Wye NOTE: For 2-Phase MagneX must be D Size E25 E E E Digits 7 8 M D MD-Multi-Phase Trip with Delta System Connection S SY-Single-Phase Trip with Wye System Connection Note: Choose MD for Two-Phase MagneX Interrupter Y 8

2-33 TABLE 9 Recommended Two-Phase MagneX Interrupter and ELSP Current-Limiting Fuse Combinations Nominal Single Phase (kv Phase to ground) 10 kva 15 kva. 25 kva 37.5 kva kva 75 kva kva 167 kva 8.3 kv 15.5 kv 23 kv 2.4 4.16-4.8 6.9 8.0 12.0 14.4 16.34 19.92 1 1 E 1 1 E 1 2 E 65 125 E25 1 165 E 165 1 E Notes: Table shows minimum recommended ELSP Fuse ratings. Recommended ELSP Backup Fuse (described in Catalog Section 2-) will coordinate with the MagneX Interrupter and melt on internal transformer faults. The MagneX Interrupter recommendations are based on: Minimum trip curves, and Maximum trip and clear curves R2-91-310. Deration factor of 0.5% per C above 25 C. Allowable loading greater than 1% for four hours in accordance with IEEE Std C57.91 1981 standard, Guide for Loading Distribution Transformers, Table 6. 125 1 E 9

Two- & Three-Phase MagneX Interrupter 10

2-33 11

Two- & Three-Phase MagneX Interrupter 2011 Cooper Industries. All Rights Reserved. Cooper Power Systems and MagneX are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries. Viton is a registered trademark of E.I. DuPont Demours & Company. IEEE Std C57.91 standard is a trademark of the Institute of Electrical and Electronics Engineers, Inc., (IEEE). This publication/product is not endorsed or approved by the IEEE. One Cooper www.cooperpower.com Online 20 Badger Drive Waukesha, WI 53188 USA 12