GRUNDFOS ALLDOS DATA BOOKLET DIP. Measuring amplifiers and controllers Preassembled systems 50/60 Hz

Similar documents
GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-PR, DIS-D. Measuring amplifiers and controllers Preassembled systems 50/60 Hz

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

Conex DIA-1, -2, -2Q. Measuring amplifiers and controllers, preassembled systems. One or two parameters (Cl 2, ClO 2, O 3, H 2 O 2, PAA, ph, ORP)

Measuring and Controlling Unit Multronic OC

Drinking water monitoring

Measuring and Controlling Unit Multronic

Ultrasonic level transmitter, non-contact

ABB ph/orp analyzer and probe package

ph or ORP Transmitter

DIGITAL ph / ORP / mv CONTROLLER PMH-2 USERS GUIDE. PMH-2 Instruction manual PAGE 1

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Instruction manual SMART 96-2 / WG-2 ph

dtrans Az 01 µp Indicator/Controller for analytical measurement

Please enter the identity code of your device here!

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

Metal Finishing. W600 Series Controllers. Summary of Key Benefits

OPTISENS ORP 8590 Technical Datasheet

Analytical Transmitters

Maintenance: Check the measurement signal: regularly required once a month Calibration: typically 6 to 12 months after installation

Please enter the identity code of your device here!

SDP Series. Solenoid dosing pumps. The right dosing choice

ABB conductivity analyzer and probe package

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

DIGITAL proportional ph CONTROLLER PPH-1 USERS GUIDE. PPH-1 Instruction manual PAGE 1

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION

1000TR. Instructions

DEPOLOX 4 BA E. MICROPROCESSOR BASED ANALYSING AND CONTROL SYSTEM FOR CHLORINE, ph AND REDOX IN POTABLE WATER AND SWIMMING POOLS

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP)

Instruction manual SMART 96-2 / WG-2 LF

Bulb ph and ORP Electrodes

New Technology for Monitoring Cycle Chemistry. David M. Gray McIlvaine Hot Topic Hour February 21, 2013

CHANFLO 2500 / 3000 Open Channel Flowmeters

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Conductivity Transmitter

OPTISENS PH ph sensor. Technical Datasheet

INSTRUCTION MANUAL Redox sensor M 1322 C

Please enter the identity code of your device here!

Please enter the identity code of your device here!

Model 50 Ground Loop ph Sensor Model 55 Solution Ground ph Sensor

Parts Per Million Dissolved Oxygen Systems

S8000 Series ph/orp Electrode Platform. Self Cleaning Flat Surface ph/orp Electrodes LIQUID ANALYTICAL SOLUTIONS THE NEXT GENERATION

Please enter the identity code of your device here!

Digital ORP sensor for the water and wastewater industry

Technical Information Memosens CCS50D

OPTISENS PH 8390 Technical Datasheet

General Specifications

WALLACE & TIERNAN MULTI-FUNCTION-CONTROLLER MFC from version V:2.00

Universal process controller econtrol

Signet ph/orp Electrodes

MODEL EPM-96 EPM-96F. ph 0 to ph14: Resolution 0.01pH 0 to 100 :Resolution temp. 1 (Selection display)

Signet ph/orp Electrodes General Purpose

Universal process controller econtrol

S8000 Series ph/orp Electrode Platform. Knowledge and Experience You Can Depend On. Self Cleaning Flat Surface ph/orp Electrodes

Shaft Absolute Vibration Monitor Specifications

AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

Universal process controller econtrol

Electronic Thermostat TE-1 Version according to EN

Grundfos Direct Sensor

OPTISENS PH 8100 Technical Datasheet

Analog outputs (option) Output 1 + 2: 0(4) 20 ma or 0 10 V

For monitoring and control of the water quality in aquariums, swimming pools, ponds and service water systems.

Electromagnetic Flow Transmitter

Signet 9950 Dual Channel Transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

Please completely read through operating instructions! Do not discard! The warranty shall be invalidated by damage caused by operating errors!

Features and Applications

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

mass flowmeter for compressed air

Magnetic Inductive Flow Sensors induq. Series VMI

Digital conductivity transmitter

Ambient Conditions. Operating Conditions. Pressure

ANALYTICAL - COMPLEXITY MADE SIMPLE

HD HD HD HD HD

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

Chlorine / Chlorine Dioxide Measurement liquisys M CCM 223 / 253

Overview of types. Technical data

General Specifications

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

COMPACT-LINE. Transmitter for ph-value

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

E l e c t r o m a g n e t i c f l o w m e t e r s

dtrans ph 01 µp transmitter / controller for ph value or redox voltage

Speed and Key Monitor Specifications

Please enter the identity code of your device here!

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

Control solutions Biofloor

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Signet 9950 Dual Channel Transmitter

ProMinent D1Cb and D1Cc Analyzers

Digital ORP sensor for the industrial wastewater industry

SMARTPAT ORP 8510 Technical Datasheet

Interface EKC 366 REFRIGERATION AND AIR CONDITIONING. Manual

Digital flow transmitter for continuous flow measurement

APPENDIX APPENDIX A 1

Transcription:

GRUNDFOS ALLDOS DATA BOOKLET Measuring amplifiers and controllers Preassembled systems 50/60 Hz

Contents Product features measuring amplifiers and controllers 3 -A preassembled systems 3 Identification Type key,, controllers 4 Type key, -A, preassembled systems 5 Functions, controllers 6 -A, preassembled systems 6 Technical data controllers and preassembled systems 7 Dimensions 8 Product selection, controllers 9 -A, preassembled systems 10 Accessories Cables 11 Buffer solutions 11 Impedance converter 11 Interface converter 11 Further product documentation WebCAPS 12 WinCAPS 13 2

Product features measuring amplifiers and controllers Triple measuring amplifier and controller for pools The (Dosing Instrumentation Pool) is specially designed for swimming pool applications. It measures up to three parameters and controls two parameters at the same time, giving you perfect control of the water quality of your pool. The speaks five languages (English, German, French, Polish and Russian), making it easy for nonexperts to carry out all operations. Other features: maintenance-free measuring electrodes a sample-water sensor to prevent overdosing a choice of control functions. Monitoring and control parameters The measures up to these three parameters at the same time: chlorine, chlorine dioxide or ozone ph redox (ORP). The controls these two parameters at the same time: chlorine, chlorine dioxide or ozone ph. Fig. 1 In the following chapters, the measuring amplifiers and controllers are simply referred to as controllers. TM04 1823 1108 -A preassembled systems Our preassembled systems take our tried-and-tested electrodes and controllers, combine them to suit specific applications, and mount them on a plate ready for quick installation. Each combination is available with a choice of measuring cells and cleaning methods. Fig. 2 -A-D2 -A preassembled system for chlorine (Cl 2 ), chlorine dioxide (ClO 2 ), ozone (O 3 ), ph and redox (ORP) Equipped with a controller, the system is particularly suitable for swimming pool water disinfection. The system incorporates one of these AquaCells: D1, pressure-proof, with cleaning motor D2, pressure-proof, with hydro-mechanical cleaning D3, pressureless, with hydro-mechanical cleaning. Note: For details on AquaCells, see separate data booklet, "Measurement and Control Accessories". Features Mounted on a base plate and wired ready for connection With prepared cable sets With Cl 2 electrode With a measuring range of 0 to 30 mg/l for Cl 2, ClO 2 or O 3 With temperature compensation. TM04 1824 1108 3

Identification Type key,, controllers Example: 1-D 2-P 3-R W-G Example: 1-D 2-P 3-R -W -G Measuring amplifier and controller Dosing Instrumentation Pool Input parameter 1 D Chlorine (Cl 2 ), chlorine dioxide (ClO 2 ) or ozone (O 3 ) Input parameter 2 P ph Input parameter 3 R Redox (ORP) Mounting W Wall-mounted Voltage G 1 x 230 V, 50/60 Hz H 1 x 120 V, 50/60 Hz 4

Identification Type key, -A, preassembled systems Example: -A, D1-P-AU-PCB-RRX-QS-T, W-H Example: -A D1 -P -AU -PCB -RRX -QS T W -H Measuring amplifier and controller Dosing Instrumentation Pool Assembly A Preassembled Cell type D1 Pressure-proof with cleaning motor D2 Pressure-proof with hydro-mechanical cleaning D3 Pressureless with hydro-mechanical cleaning Pressure retention valve P With pressure-retention valve X Without pressure-retention valve Disinfection electrodes AU Gold PT Platinum ph electrodes PCB ph, ceramic diaphragm, with buffer solution PTB ph, PTFE diaphragm, with buffer solution PKB ph, KCL filling, with buffer solution PGB ph, gel filling, with buffer solution PCX ph, ceramic diaphragm, without buffer solution PTX ph, PTFE diaphragm, without buffer solution PKX ph, KCL filling, without buffer solution PGX ph, gel filling, without buffer solution X No electrode Redox (ORP) electrodes RRB Redox (ORP), without reference system, with buffer solution RRX Redox (ORP), without reference system, without buffer solution X No electrode Flow sensor QS Flow sensor integrated X No flow sensor Temperature sensor T With Pt100 X No temperature sensor Mounting W Wall-mounted P Panel-mounted Voltage G 1 x 230 V, 50/60 Hz H 1 x 120 V, 50/60 Hz 5

Functions, controllers Features Input parameter 1 Chlorine (Cl 2 ) Chlorine dioxide (ClO 2 ) Ozone (O 3 ) Input parameter 2 ph Input parameter 3 Redox (ORP) Input, miscellaneous Flow sensor Controller stop (potentialfree contact) Mounting options Voltage Wall-mounted 1 x 230 V, 50/60 Hz 1 x 120 V, 50/60 Hz -A, preassembled systems Features Cell type Pressure-proof, with cleaning motor Pressure-proof, with hydro-mechanical cleaning Pressureless, with hydro-mechanical cleaning Electrodes Gold (disinfection only) Platinum (disinfection only) ph Variant Redox (ORP) Flow sensor Remote on/off Temperature sensor Pt100 Voltage -A 1 x 230 V, 50/60 Hz 1 x 120 V, 50/60 Hz 6

Technical data controllers and preassembled systems General data Electronics Max. distance from the to the sensors Display Indication mode Relay outputs (max. relay load 250 V/ 6 A, max. 550 VA) Signal outputs (max. load: 500 Ohm) Interface Temperature compensation ph compensation 16-bit microprocessor system 3 metres Two high-resolution plain-text LCD displays Measured value as a physical variable One alarm relay One stand-by relay Each parameter of parameter groups 1 and 2 have these relays: one alarm relay two potential-free controller switch relays for Cl 2 or ClO 2 or O 3 or ph. The potential-free controller switch relays can be configured as either of these: limit switch 2-position controller (pulse pause, pulse frequency) 3-position step controller for either - Cl 2 or ClO 2 or O 3 with or without return or - for ph without return. Four analog outputs (0-20 ma or 4-20 ma), galvanically isolated from the inputs, for these measuring parameters: disinfection parameter Cl 2 / ClO 2 / O 3 ph redox (ORP) temperature. two analog outputs (0-20 ma or 4-20 ma) for continuous controller: disinfection parameter Cl 2 / ClO 2 / O 3 ph (chlorine and ph). CAN bus The temperature can be measured automatically by a Pt100 sensor ( 5 to 120 C, measured in C or F) or set manually on the controller. Automatically by ph measurement A plausibility check function checks whether the ph value of the buffer solution is within acceptable limits. Automatic recognition of the buffer solution Calibration of ph ensures that the right buffer solution is used for the calibration. If the user calibrates the ph value with a wrong buffer solution, an error message will be displayed. Operation: 0 to 50 C Permissible temperature Storage: 20 to +65 C Permissible relative Max. 90% (non-condensing) humidity Power consumption Approx. 15 VA Enclosure class IP 65 Weight Approx. 2 kg Measuring parameters and ranges Parameter group Parameter 1 2 ph 3 1) As regards preassembled systems, the lower limit of the measuring range can be different, depending on the type of measuring cell. Control data Description Setpoint Chlorine (Cl 2 ) [mg/l] Chlorine dioxide (ClO 2 ) [mg/l] Ozone (O 3 ) [mg/l] Redox (ORP) [mv] Value Possible measuring range 1) 0.00-0.50 0.00-1.00 0.00-2.00 0.00-5.00 0.0-10.0 0.0-20.0 0.0-30.0 0.00-0.50 0.00-1.00 0.00-2.00 0.00-5.00 0.0-10.0 0.0-50.0 0.00-0.50 0.00-1.00 0.00-2.00 0.00-5.00 0.00-14.00 2.00-12.00 5.00-9.00 1500 to +1500 0-1000 Adjustable as physical variable within the measuring range (for example mg/l) Hysteresis 0 to 50 % of the upper limit of the measuring range Setpoint selection 0 to 100 % of the measuring range Proportional band, X p 0.1 to 3000 % Reset time, T N 1 to 3000 s, resolution 1 s Derivative action time, T V 1 to 1000 s, resolution 1 s Constant load 0 to 50 % Limitation of the maximum dosing capacity Control direction From the adjusted constant load up to 100 % Upward or downward control TM04 1823 1108 TM04 1824 1108 Fig. 3 Fig. 4 -A-D2 7

Technical data Dimensions 27 121 70 TM04 2298 2308 Fig. 5 Dimensions, controller TM03 3976 1306 216.5 177 15 242 255 Fig. 6 Dimensions, -A, preassembled system 8

Product selection, controllers Input parameter Voltage Controller mounting Enclosure material Enclosure class 1 2 3 Controller 115/120 V 230/240 V Panel-mounted Wall-mounted Polystyrene Noryl (enclosure) ABS (sensor interface) IP 65 IP 54 (enclosure) IP 65 (sensor interface) Chlorine (Cl 2 ), chlorine dioxide (ClO 2 ) or ozone (O 3 ) Type designation, 1-D 2-P 3-R, W-H, 1-D 2-P 3-R, W-G ph ph Redox (ORP) Product number 96622358 (353-2000-10002) 96622357 (353-2000-10001) 9

Product selection -A, preassembled systems Voltage Cell type Electrode Sensor 1 2 3 Controller 115/120 V 230/240 V D1, pressure-proof with cleaning motor D2, pressure-proof with hydromechanical cleaning D3, pressureless with hydromechanical cleaning With pressure-retention valve Without pressure-retention valve Gold (Cl 2, ClO 2, O 3 ) (disinfection) Platinum (Cl 2, ClO 2, O 3 ) (disinfection) ph ceramic diaphragm Type designation -A -A, D1-P-AU-PCB-RRB-QS-T, W-H Redox (ORP) ceramic diaphragm -A, D1-P-AU-PCB-RRB-X-T, W-H -A, D1-P-PT-PCB-RRB-QS-T, W-H -A, D1-P-PT-PCB-RRB-X-T, W-H -A, D2-P-AU-PCB-RRB-QS-T, W-H -A, D2-P-PT-PCB-RRB-QS-T, W-H -A, D3-X-AU-PCB-RRB-QS-T, W-H -A, D3-X-AU-PCB-RRB-X-T, W-H -A, D3-X-PT-PCB-RRB-QS-T, W-H -A, D3-X-PT-PCB-RRB-X-T, W-H -A, D1-P-AU-PCB-RRB-QS-T, W-G -A, D1-P-AU-PCB-RRB-X-T, W-G -A, D1-P-PT-PCB-RRB-QS-T, W-G -A, D1-P-PT-PCB-RRB-X-T, W-G -A, D2-P-AU-PCB-RRB-QS-T, W-G -A, D2-P-PT-PCB-RRB-QS-T, W-G -A, D3-X-AU-PCB-RRB-QS-T, W-G -A, D3-X-AU-PCB-RRB-X-T, W-G -A, D3-X-PT-PCB-RRB-QS-T, W-G -A, D3-X-PT-PCB-RRB-X-T, W-G Redox (ORP) without reference system Flow sensor Temperature sensor Product number 96622514 (314-339-10027) 96622519 (314-339-10031) 96622516 (314-339-10029) 96622522 (314-339-10033) 96622719 (314-939-10019) 96622721 (314-939-10021) 96622657 (314-639-10016) 96622661 (314-639-10020) 96622659 (314-639-10018) 96622663 (314-639-10022) 96622512 (314-339-10038) 96622518 (314-339-10035) 96622515 (314-339-10028) 96622520 (314-339-10018) 96622718 (314-939-10022) 96622720 (314-939-10020) 96622656 (314-639-10015) 96622660 (314-639-10012) 96622658 (314-639-10017) 96622662 (314-639-10021) 10

Accessories Cables Description Cable, 1 metre, for reference, ph and redox (ORP) electrode Cable, 3 metres, for reference, ph and redox (ORP) electrode Cable, 10 metres, for ph and redox (ORP) electrode * Cable, 25 metres, for ph and redox (ORP) electrode * * If the length of the cable between controller and electrode exceeds 3 metres, an impedance converter is required. Buffer solutions for ph and redox (ORP) Description ph Redox (ORP) Buffer solutions for calibrating the ph single-rod probes 1 set per 100 ml for ph 4.01, 7.00 or 9.18 Buffer solutions for checking the redox (ORP) single-rod probes or electrodes, 100 ml (+220 mv) Product number 96609182 (321-252) 96609183 (321-250) 96701441 (321-250/10) 95703576 (321-250/25) Product number 96609165 (549-050) 96609166 (549-051) Impedance converter for ph and redox (ORP) Description Impedance converter for ph or redox (ORP) measurement. The impedance converter is necessary if the length of the cable between controller and electrode exceeds 3 metres. ph Redox (ORP) Product number 95704730 (336-312) TM04 1839 1108 Fig. 8 Dimensions, impedance converter Interface converter TM04 1829 1108 Description CAN bus/rs232 converter for bidirectional connection of to a PLC Product number 95702009 (353-0501) Fig. 7 Buffer solutions 11

Further product documentation WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: Catalogue Literature Service Sizing Replacement CAD drawings. Catalogue This section is based on fields of application and pump types, and contains technical data curves (QH, Eta, P1, P2, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as data booklets installation and operating instructions service documentation, such as Service kit catalogue and Service kit instructions quick guides product brochures, etc. Service This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts. 12

0 1 Further product documentation Sizing This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyse your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc. Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings:.dxf, wireframe drawings.dwg, wireframe drawings. 3-dimensional drawings:.dwg, wireframe drawings (without surfaces).stp, solid drawings (with surfaces).eprt, E-drawings. WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185.000 Grundfos products in more than 20 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year. Fig. 9 WinCAPS CD-ROM 13

14

15

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96812344 0908 Repl. 96622278 1006 GB Subject to alterations. Grundfos Management A/S Poul Due Jensens Vej 7 DK-8850 Bjerringbro Telephone: +45 87 50 14 00 Grundfos Alldos Dosing & Disinfection Alldos Eichler GmbH Reetzstrasse 85 D-76327 Pfinztal (Söllingen) Telephone: +49 72 40 61 0 www.grundfosalldos.com