Power Tube. Beam Power Tube

Similar documents
9007 Power Tube. VHF Linear Power Amplifier Tube 33 Kilowatt Peak Sync Output Thru VHF-TV Band

8984 Power Tube. VHF Linear Beam Power Tube

8988 Power Tube. Linear Beam Power Tube

8807 Power Tube. Beam Power Tube

4665 Power Tube UHF Pulsed Power Amplifier Tube

8792 Power Tube. Linear Beam Power Amplifier Tube

8072 Power Tube. VHF Linear Amplifier Tube. Coaxial-Electrode Structure Ceramic-Metal Seals Full Input to 500 MHz Conduction Cooled

8791 Power Tube. Linear Beam Power Amplifier Tube

8791/V1 Power Tube. VHF-TV Amplifier Tube

8121 Power Tube. Linear Beam Power Tube

4662 Power Tube. Linear Beam Power Tube

6884 Power Tube. Beam Power Tube

Svetlana 4CX7500A Radial Beam Power Tetrode

General Data Electrical Heater for Oxide-Coated Unipotential Cathode: Voltage (AC or DC) 26.5 ± 10% Current at 26.5 volts

RADIAL BEAM POWER CPI RADIAL 4CW50,000J BEAM POWER TETRODE 4CX20,000C

MEDIUM-MU AIR-COOLED POWER TRIODE 3CX15,000H3

Svetlana 3CX3000F7/8162 High-Mu Power Triode

PL8877/ 3CX1500A7 High-Mu Power Triode

L A B O R A T O R I E S 9740 COZYCROFT AVENUE * CHATSWORTH * CALIFORNIA (800) * (818) * FAX: (818)

4X150A/7034 Radial Beam Power Tetrode

PET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F

HIGH-MU POWER TRIODE 3CW40,000A7

YC-179 / YC-179A CPI HIGH-MU 4CW50,000J POWER TRIODE YC-179 / YC-179A

HIGH-MU AIR-COOLED POWER TRIODE 3CX1500D7

PET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F

4-400C/6775 Radial Beam Power Tetrode

4CM500,000G MULTIPHASE-COOLED POWER TETRODE

MG5223F S-Band Magnetron

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

Transmitter Tetrode. Approx. weight 16 kg. 360 Siemens Aktiengesellschaft. ➀ Tube support ➁ Air inlet ➂ Do not use as terminal.

M5028 Precision Tuned Magnetron

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

Transmitter Tetrode TH 347

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

E2V Technologies MG5223F S-Band Magnetron

CX1140 Hydrogen Thyratron

Transmitter Tetrode RS 1034

90 Siemens Aktiengesellschaft

Abridged Data. General Data. MG7095 Tunable S-Band Magnetron for Switched Energy Applications. Cooling. Electrical. Accessories.

MG7095 Tunable S-Band Magnetron

LIQUID-COOLED POWER CPI LIQUID-COOLED 4CW50,000J POWER TETRODE 4CW30,000B

GRID CONTROLLED POWER SUPPLY IS A VERSATILE UNIT Uses Pair of RCA-2050 s for Wide Voltage Range

E2V Technologies CX1725, CX1725X Liquid Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

TECHNIlCAL DATA. Amperes Cathode Heating Time..300

E2V Technologies MG5222 X-Band Magnetron

Transmitter Tetrode. Approx. weight 1,1 kg Packing dimensions: approx. 310 mm 310 mm 320 mm. Siemens Aktiengesellschaft 375

E2V Technologies M5187F X-Band Magnetron

Siemens Aktiengesellschaft 299

MG5193 Tunable S-Band Magnetron

E2V Technologies MG6028 Fast Tuned Magnetron

Siemens Aktiengesellschaft 101

2 5 1 A Va c u u m T u b e

MG6090 Tunable S-Band Magnetron

E2V Technologies CX1175C Deuterium-Filled Ceramic Thyratron

2 5 4 A V a c u u m T u b e

Transmitter Triode RS 2041 V YD 1262

Definitions of Technical Terms

LBI-4938C. Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3. Printed in U.S.A. Maintenance Manual

Instruction Manual OM3500 HF SHORTWAVE POWER AMPLIFIER. OM POWER, s. r. o Bác 126 SLOVAKIA

Western Electric D V a c u u m T u b e

186 Siemens Aktiengesellschaft

S-band 500kW Magnetron

Siemens Aktiengesellschaft 137

5/1.0 kw AM Transmitter

M5187 X-Band Magnetron

MULTI-PHASE COOLED POWER TETRODE

Siemens Aktiengesellschaft 211

A 100-Watt Transmitter Using a Pair of VT1625s

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, POWER TYPES 7203 AND 7203A

Continental's 816R -5B, 35 kw Single Tube Broadcast Transmitter. Includes the 802A solid -state exciter

Filament Thoriated tungsten. Filament voltage...14 volts Nominal filament current... 6 amperes Average thermionic emission...

WATER COOLED POWER TETRODE 8974

Western E/ectrk A V a c u u m T u b e

MG MW S-Band Magnetron

Central Electronics Model 600L Linear Amplifier

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, POWER TYPE 8660

ABSOLUTE MAXIMUM RATINGS These ratings cannot necessarily be used simultaneously and no individual ratings should be exceeded.

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

YD1195/8913 YD1197/8937 RF Power Triodes

LM6118/LM6218 Fast Settling Dual Operational Amplifiers

VHF LAND MOBILE SERVICE

4/30/2012. General Class Element 3 Course Presentation. Practical Circuits. Practical Circuits. Subelement G7. 2 Exam Questions, 2 Groups

Transmitter Tetrode RS 2078 SK TH 558

Model FM350 FM Broadcast Pallet Amplifier

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE DOD-011

100W Wide Band Power Amplifier 6GHz~18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz Gain db

Frequency Range: MHz. Efficiency: 10% Temperature Range: 0 to 60 C Max VSWR: 5:1. Class: Supply Voltage: 28.0V

BTM Series Pulsed RF Power Amplifier Modules. Application Note

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 8943


Stand Alone RF Power Capabilities Of The DEIC420 MOSFET Driver IC at 3.6, 7, 10, and 14 MHZ.

8854 Photomultiplier. 129-mm (5-inch) Diameter, 14-stage QUANTACON TM Type Having a Bialkali Photocathode and High- Gain Gallium-Phosphide Dynodes

Mirage B-320-G FEATURES

HLV-350. Instruction & Operations Manual

A 75-Watt Transmitter for 3 Bands Simplified Shielding and Filtering for TVI BY DONALD H. MIX, W1TS ARRL Handbook 1953 and QST, October 1951

Frequency Range: MHz. Efficiency: 80% Temperature Range: -20 to 65 C Max VSWR: 3:1. Class: Supply Voltage: 32.0V

1 FUNCTIONAL DESCRIPTION WAY SPLITTER/INPUT BOARD FET RF AMPLIFIERS WAY POWER COMBINER VSWR CONTROL BOARD...

BROADCAST EOUIPMENT RADIO CORPORATION OF AMERICA. ENGINEERING PRODUCTS DEPARTMENT, Camden, N. J., U. S. A.

1208 P10-VHF-H-20. Frequency Range: MHz. Efficiency: 10% Temperature Range: 0 to 70 C Max VSWR: 5:1. Class: Supply Voltage: 28.

Transcription:

8977 Power Tube Beam Power Tube - 7 kw Aural Output Through VHF-TV Band - 19 db Gain - CERMOLOX Beam Power Tube - Full Input to 400 MHz - Forced-Air Cooled The BURLE 8977 is intended specifically to meet the high gain, aural requirements of modern, reliable, VHF-TV. In VHF-TV aural service at 216 MHz, the tube will deliver a full 7.0 kw output at 19 db gain. Rated for full input for the VHF-TV band and for other service to 400 MHz, the tube can be readily circuited for these frequencies. The tube and available variants are also well suited for other applications such as Single Sideband CW, pulsed RF or modulator service. Its sturdy, CERMOLOX construction and thoriated tungsten, mesh filament minimize tube inductances and feed-thru capacitances. Its coaxial, forced-air-cooled radiator reduces noise to a minimum and insures against spurious outputs. These features make possible the use of simple, economical, broadband circuit techniques in VHF and UHF operation. Close attention to the instructions contained in these publications will assure longertube life, safer operation, less equipment downtime and fewer tube handling accidents. For copies of these publications, contact your BURLE Representative or write BURLE INDUSTRIES INC., 1000 New Holland Ave., Lancaster, PA 17601-5688. General Data Electrical This data sheet gives application information unique to the BURLE 8977. It is to be used in conjunction with the publication, Application Guide for BURLE Power Tubes, TP-105, for general application information for tubes of this type. Additional information of a general nature applicable to tubes of this type is given in the following publications: TP-105 TP-122 TP-117 TP-118 Application Guide for BURLE Power Tubes Screen-Grid Current, Loading and Bleeder Considerations Handling and Operating Considerations when Using BURLE Tetrodes Application Guide for Forced Air Cooling BURLE Power Tubes (Grid No.2 to grid No.1)......................................20 Direct Interelectrode Capacitances: Grid No. 1 to plate f........................................................0.40 max. Grid No.1 to filament..........................................75 Plate to filament f..........................................................0.05 max. Grid No.1 to grid No.2........ 85 Grid No.2 to plate................................................11 Grid No.2 to filament f... 2.5 max.

General Data (Cont d) Mechanical Operating Attitude... Vertical, either end up Overall Length... 160.02 mm (6.300 in) Greatest Diameter... 141.5 mm (5.570 in) Terminal Connections... See Dimensional Outline Radiator... Integral part of tube Weight (Approx.)... 2.7 kg ( 6.0 Ibs) Thermal Seal Temperature g (Plate, grid No.2, grid No.1, filament-cathode and filament)... 250 max. C Plate-Core Temperatures g,h... 250 max. C RF Power Amplifier or Oscillator- Class B Telegraphy or FM Telephony j Maximum CCS Ratings, Absolute-Maximum Values Up to 400 MHz DC Plate Voltage k... 13,000 v DC Grid-No.2 Voltage m... 1650 V DC Grid-No. 1 Voltage n... -450 V DC Plate Current... 4.0 A DC Grid-No.1 Current... 500 ma Grid-No.1 Input... 50 w Grid-No.2 Input... 100 w Plate Dissipation p,h... 6000 W Maximum Circuit Values Grid-No.1 Circuit Resistance Under Any Conditions: With fixed bias... 5000 max. ohm With cathode bias... Not recommended Grid-No.2 Circuit Impedance... See note m Plate Circuit Impedance... See note k Calculated CCS Operation In a cathode-drive, Class AB 2, circuit at 216 MHz DC Plate Voltage... 8200 V DC Grid-No.2 Voltage... 1000 V DC Grid-No.1 Voltage... -40 V Zero-Signal DC Plate Current... 0.500 A DC Plate Current... 1.35 A DC Grid-No.2 Current... 30 ma DC Grid-No.1 Current... 40 ma Drive Power Output (Approx.) q... 85 W Output Circuit Efficiency... 95 % Useful Power Output... 7000 W a b Measured at the tube terminals. For accurate data the ac filament voltage should be measured using an accurate RMS type meter such as an iron-vane or thermocouple type meter. The dc voltage should be measured using a high input impedance type meter. For high-current, low-voltage filaments such as are used in this tube, it is recommended that the filament current be monitored, since very small changes in resistance can produce misleading changes in voltage, For maximum life, the filament power should be regulated at the lowest value that will give stable performance. For those applications where hum is a critical consideration, dc filament or hum-bucking circuits are recommended. See also Application Note TP-117. The range of current at 5.7 volts is from 106 to 126 amperes. It is recommended that an additional six amperes be available to allow C d e f 9 h j k m for the normal reduction of filament resistance with life. Thus, the filament supply should be designed for a mean value of 132 amperes at 5.7 volts. A minimum setting is 5.4 volts. Use an oscilloscope in system checkout. Systems such as autotransformers, step transformers, shortable limiting resistors, saturable reactors, or combinations thereof must be used. Recommended starting procedure for maximum stability and longest life. Standard: Filament heating time of 120 seconds followed by grid-no.1, plate, grid-no.2, and RF drive. Emergency 1: (Power Interruption of 15 seconds or less) The tube may be brought back on the air two seconds after power restoration. Precautions must be taken so that neither the filament surge current limit nor the maximum filament voltage rating is exceeded. The sequence of voltage application after filament warm-up is as follows: grid-no.1, plate, grid-no.2, and RF drive. Emergency 2: (Power Interruption of greater than 15 seconds) The tube may be brought back on the air four seconds after power restoration. Precautions must be taken so that neither the filament surge current limit nor the maximum filament voltage rating is exceeded. In order to insure that the tube does not operate in excess of typical conditions, control of the RF drive level will be required until tube temperature stability is achieved and special consideration must be given to the design of grid-no.1 circuitry. Application Engineering assistance is available from BURLE. The sequence of voltage application after filament warm-up is as follows: grid-no.1, plate, grid-no.2, and RF drive. For plate voltage = 2000 V, grid-no. 2 voltage = 1375 V, and plate current = 6.0 A. As measured with a special, shielded adapter. The value noted is the true tube internal capacitance and does not include external circuit or stray capacitance. See Dimensional Outline for Temperature Measurement Points. For good contact-finger life, a maximum temperature of 180 C at the terminal is recommended when using commercially available beryllium-copper socket contacts. The value of 250 C is the average of three readings taken 120 apart around the anode core. No one reading may exceed 275 C. See TP-105. See TP-105. The maximum voltage ratings must be modified for operation at altitudes higher than sea level and for temperatures in excess of 20 C in accordance with the curves of Figure 1. For altitude derating of the plate voltage, use the voltage difference between the plate and the grid No. 2. The maximum fault energy that can be dissipated within the tube is approximately 100 joules. Therefore, the energy available for a high-voltage arc or fault must be limited to this value by means of current limiting resistors or fault-protection circuitry. This is especially important in pulse service where high, stored energy and large capacitors are used. For typical TV transmitters, series resistor values are: Plate = 10 ohm Screen = 30 to 50 ohm

n P q See TP-105. Protection devices such as spark gaps or positive clamping diodes should be used. Permitted plate dissipation is a function of cooling. For specific ratings, see Forced Air Cooling information in this data sheet. Drive power output represents circuit losses in the driver output circuit and the grid input circuit in addition to the power necessary to drive the tube. Operating Considerations Filament Voltage Adjustment The life of the filament can be conserved by adjusting to the lowest filament supply voltage that will give the desired performance. Follow the filament voltage adjustment procedure below: 1. Before the application of any other voltages to a new tube, the filament voltage should be adjusted to 5.7 volts at the tube socket. A true RMS voltmeter should be used for accurate measurement. It may be more convenient to make the measurement at other contacts in the equipment, but the value will be higher because of increased impedance such as wire loss or contact resistance. 2. Apply voltages and adjust tuning controls as necessary for proper operation as described in the appropriate instruction manual. 3. Reduce the heater voltage in 0.1 -volt increments - repeating the procedures in Step 1 and 2 - until performance degradation is noted. Then increase the heater voltage 0.1 volt above this point. Typically, depending upon the application, this voltage will be in the range of 5.4 to 5.7 volts. During life when evidence is observed that a tube is becoming emission limited, increasing the filament voltage may extend the useful life of the tube. However, never increase filament voltage to compensate for a decrease in other circuit parameters such as RF drive. Safety Precautions Protection circuits serve a threefold purpose: safety of personnel, protection of the tube in the event of abnormal circuit operation, and protection of the tube circuits in the event of abnormal tube operation. Warning - Personal Safety Hazards Electrical Shock- Operating voltages applied to this device present a shock hazard. X-Ray Warning - This device in operation produces x-rays which can constitute a health hazard unless the device is adequately shielded for radiation. RF Radiation - This device in operation produces tion which maybe harmful to personnel. RF radia- Power tubes require mechanical protective devices such as interlocks, relays, and circuit breakers. Circuit breakers alone may not provide adequate protection in certain power-tube circuits when the power-supply filter, modulator, or pulse-forming network stores much energy. Additional protection may be achieved by the use of high-speed electronic circuits to bypass the fault current until mechanical circuit breakers are opened. These circuits may employ a controlled gas tube, such as a thyratron or ignitron, depending on the amount of energy to be handled. Great care should be taken during the adjustment of circuits. The tube and its associated apparatus, especially all parts which may be at high potential above ground, should be housed in a protective enclosure. The protective housing should be designed with interlocks so that personnel can not possibly come in contact with any high-potential point in the electrical system. The interlock devices should function to break the primary circuit of the high-voltage supplies and discharge high-voltage capacitors when any gate or door on the protective housing is opened, and should prevent the closing of this primary circuit until the door is again locked. The screen circuit requires special attention because the heating power of the current and voltage on this electrode is not the algebraic product of the current and voltage elements as observed at the terminal. For an analysis of the circuit review the BURLE Application Note TP-122 Screen Grid Current, Loading and Bleeder Considerations. A time-delay relay must be provided in the grid No.2 supply circuit to delay application of this voltage until the filament has reached normal operating temperature. An interlocking relay system should be provided to prevent application of plate voltage prior to the application of sufficient bias voltage otherwise, with insufficient bias, the resultant high plate current may cause excessive plate dissipation with consequent damage to the tube. RF load shorts or other causes of high output VSWR may also cause high dissipations, excessive voltage gradients, or insulator flashover. The load VSWR should be monitored and the detected signal used to actuate the interlock system to remove the plate voltage in less than 10 milliseconds after the fault occurs. Forced Air Cooling Cooling air flow is necessary to limit the anode-core and terminal-seal temperatures to values that will assure long reliable life. A sufficient quantity of air should be directed past each of these terminals so that its temperature does not approach the absolute-maximum limit. The absolute maximum temperature rating for this tube is 275 C with a maximum average temperature around the anode of 250 C. It is recommended that a safety factor of 25 to 50 be applied, to compensate for all probable system and component variations throughout life. The cooling air must be delivered by the blower through the radiator and at the terminal seals during the application of power and for a minimum of three minutes after the power has been removed. To Cathode-Filament and Filament Terminals -- A sufficient quantity of air should be blown directly at these terminals so that their temperature does not approach the absolute-maximum limit of 250 C. A value of at least 60 cfm is recommended. -3-

GRID No. 2 VOLTAGE E c2 = 1000 V GRID No. 1 CURRENT I c1 = - GRID No. 2 CURRENT I c2 = - - - - - - - - - - - - Incoming air is at Standard Temperature and Pressure (STP) (22.5 C and 760 mm Hg). Pressure drop values are for the anode only and do not include any losses which may occur with specific sockets or cavities. When the tube base is not directly in the anode cooling air stream, special provisions must be made for separate base cooling. Because the cooling capacity of air varies with its density, factors must be applied to the air flow to compensate for operation at altitude or in high temperature environments. 200 150 100 During Standby Operation -- Cooling air is required when only the filament voltage is applied to the tube. For further information on forced air cooling, see TP-105 and also TP-118 Application Guide for Forced Air Cooling of BURLE Power Tubes. Tube Removal From Socket (Suggested Design) The tube should not be removed from the socket by rocking the tube back and forth. This motion crushes the contact fingers and applies undue force to the internal structure of the tube. (See Figure 6.) -50-150 0 1 2 3 4 5 6 7 8 PLATE VOLTAGE - KILOVOLTS 92LM-3673 Figure 2 -Typical Constant Current Characteristics 0 5 10 15 ALTITUDE -THOUSAND FEET 92LS-4596 Figure 1 - Maximum DC Voltage vs Altitude The Cooling Characteristic Curve indicates the air flow and pressure requirements of a system sufficient to limit the core temperature to specific values for various levels of plate dissipation. -4-

AIR COOLING DATA DIRECTION OF AIR FLOW CURVE WATTS 2000 I I AIR FLOW/PRESS DROP --- NOTE INCOMING AIR TEMP STP MEASUREMENTS IN ACCORDANCE WITH STANDARD TEST CODE FOR AIR MOVING DEVICES, AMCA STANDARD 210-67 400 300 200 100 AVERAGE ANODE CORE TEMPERATURE% (SOLID LINE) 1 2 3 4 5 6 PRESSURE DROP - INCHES H 20 (DASHED LINE) Figure 4 - Typical Cooling Characteristics 92LM-5884 Figure 3 -Typical Constant Current Characteristics -5-

Tabulated Dimensions GRID No. 2 TERMINAL GRID No. 1 TERMINAL TEMPERATURE MEASUREMENT POINT STIPPLED REGION SEE NOTE 2 Dimensions Inches A Dia. 5.530 ±.040 B Dia. 4.188 ±.020 C Dia. 3.028 ±.014 D Dia. 2.319 ±.012 E Dia. 1.850 ±.010 F Dia. 1.200 ±.010 G Dia. 0.617 ±.003 H 6.300 max. J 5.300 max. K 2.195 ±.020 L 1.860 ±.030 M 2.390 ±.040 N 1.490 ±.020 P 0.200 ±.025 S 0.475 ±.030 T 0.725 ±.040 U 0.955 ref. V 0.250 min. W 0.375 min. X 0.220 min. Y 0.265 min. Z 1.200 min. Millimeters 140.05 ± 1.02 106.37 ±.51 76.91 ±.36 58.90 ±.30 46.99 ±.25 30.48 ±.25 15.67 ±.08 160.02 max. 134.62 max. 55.75 ±.51 47.24 ±.76 60.71 ± 1.02 37.85 ±.51 5.08 ±.64 12.07 ±.76 18.42 ± 1.02 24.26 ref. 6.35 min. 9.53 min. 5.59 min. 6.73 min. 30.48 min. Notes Figure 5 - Dimensional Outline AIR FLOW 92LM-5034R1I Note 1 - The diameter of each terminal is maintained only over the indicated minimum length of its contact surface. Note 2 - Keep all stippled regions clear. In general do not allow contacts to protrude into these annular regions. If special connectors are required which may intrude on these regions, contact BURLE Power Tube Application Engineering, Lancaster, PA 17601. Note 3 - Tapped 1/4-20 NC x 0.5 (12.7 mm) deep. May be used for attaching additional heat sink for seal temperature control if required. Note 4 - Plate core temperature measurement point is located on the plate itself and not at the fins. Note 5 - With the plate terminal and the cathode-filament terminal used as reference, the other terminals will measure less than 0.040 (1.02 mm) total indicator run-out (TIR). -6-

Note 1 - Material 1/8 thick cold rolled steel Note 2 - Round all edges Note 3 - Slot between holes 3.80 (96.5).13 92LS-5035 Figure 6 - Tube Extractor (Suggested Design) -7-