SOFT SWITCHING ANALYSIS IN DC-DC BOOST CONVERTERS

Similar documents
AN IMPROVED ZERO-VOLTAGE-TRANSITION INTERLEAVED BOOST CONVERTER WITH HIGH POWER FACTOR

Energy Conversion and Management

Chapter 6 Soft-Switching dc-dc Converters Outlines

International Journal of Engineering Science Invention Research & Development; Vol. II Issue VIII February e-issn:

A HIGH EFFICIENT IMPROVED SOFT SWITCHED INTERLEAVED BOOST CONVERTER

Design of step-up converter for a constant output in a high power design

ANALYSIS OF ZVT DC-DC BUCK-BOOST CONVERTER

High Frequency Soft Switching Of PWM Boost Converter Using Auxiliary Resonant Circuit

Interleaved Boost Converter Fed DC Machine with Zero Voltage Switching and PWM Technique

ACEEE Int. J. on Control System and Instrumentation, Vol. 02, No. 02, June 2011

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

Performance Enhancement of a Novel Interleaved Boost Converter by using a Soft-Switching Technique

ZVS IMPLEMENTATION IN INTERLEAVED BOOST RECTIFIER

International Journal of Engineering Research-Online A Peer Reviewed International Journal

A Novel Technique to Reduce the Switching Losses in a Synchronous Buck Converter

A Novel Single Phase Soft Switched PFC Converter

IJMIE Volume 2, Issue 9 ISSN:

Bridgeless Cuk Power Factor Corrector with Regulated Output Voltage

Soft-Switched High Efficiency CCM Boost Converter with High Voltage Gain

ANALYSIS, SIMULATION AND HARDWARE IMPLEMENTATION OF BOOST DC-DC CONVERTER

Implementation of an Interleaved High-Step-Up Dc-Dc Converter with A Common Active Clamp

Fuel Cell Based Interleaved Boost Converter for High Voltage Applications

Analysis and Design of a Bidirectional Isolated buck-boost DC-DC Converter with duel coupled inductors

Reducing Switching Losses in Switched Reluctance Motor (SRM) Starting System

DESIGN AND SIMULATION OF PWM FED TWO-PHASE INTERLEAVED BOOST CONVERTER FOR RENEWABLE ENERGY SOURCE

Bidirectional DC-DC Converter Using Resonant PWM Technique

IN THE high power isolated dc/dc applications, full bridge

Closed Loop Controlled ZV ZCS Interleaved Boost Converter System

Key words: Bidirectional DC-DC converter, DC-DC power conversion,zero-voltage-switching.

International Journal of Scientific & Engineering Research, Volume 6, Issue 4, April-2015 ISSN

ZVT Buck Converter with Synchronous Rectifier

Simulation and Performance Evaluation of Closed Loop Pi and Pid Controlled Sepic Converter Systems

f r f s V o V s i L1 i L2 V c1 V c2 V c

IN THE LAST few years, power factor correction, minimization

ZERO VOLTAGE TRANSITION SYNCHRONOUS RECTIFIER BUCK CONVERTER

An Application of Soft Switching for Efficiency Improvement in ZVT-PWM Converters

COMPARISON OF SIMULATION AND EXPERIMENTAL RESULTS OF ZVS BIDIRECTIONAL DC-DC CONVERTER

RECENTLY, photovoltaic (PV) energy has attracted interest

High Frequency Isolated Series Parallel Resonant Converter

Chapter 2 LITERATURE REVIEW

TYPICALLY, a two-stage microinverter includes (a) the

Multiple Output Converter Based On Modified Dickson Charge PumpVoltage Multiplier

ZCS-PWM Converter for Reducing Switching Losses

Theoretical analysis of Zero Voltage and Zero Current Switching Resonant Pulse Width Modulation for High Power Applications

High Voltage Gain Interleaved Boost Converter

Non-isolated DC-DC Converter with Soft-Switching Technique for Non-linear System K.Balakrishnanet al.,

Existing system: The Master of IEEE Projects. LeMenizInfotech. 36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue, Pondicherry

THE converter usually employed for single-phase power

IN APPLICATIONS where nonisolation, step-down conversion

A NOVEL SOFT-SWITCHING BUCK CONVERTER WITH COUPLED INDUCTOR

VOLTAGE MODE CONTROL OF SOFT SWITCHED BOOST CONVERTER BY TYPE II & TYPE III COMPENSATOR

Comparative Analysis of Soft Switching Boost Converter

Design and Simulation of New Efficient Bridgeless AC- DC CUK Rectifier for PFC Application

A Novel Concept in Integrating PFC and DC/DC Converters *

Linear Transformer based Sepic Converter with Ripple Free Output for Wide Input Range Applications

ANALYSIS OF BIDIRECTIONAL DC-DC CONVERTER FOR LOW POWER APPLICATIONS

H-BRIDGE system used in high power dc dc conversion

LLC Resonant Converter for Battery Charging Application

Quasi Z-Source DC-DC Converter With Switched Capacitor

Analysis and Simulation of Full-Bridge Boost Converter using Matlab

High Efficiency DC/DC Boost Converters for Medium/High Power Applications

Soft-Switching Two-Switch Resonant Ac-Dc Converter

Student Department of EEE (M.E-PED), 2 Assitant Professor of EEE Selvam College of Technology Namakkal, India

COMPARISON OF GRID CONNECT MULTI-LEVEL INVERTER

THE TWO TRANSFORMER active reset circuits presented

Analysis of Novel DC-DC Boost Converter topology using Transfer Function Approach

Analysis of Non-Isolated Bidirectional Active Clamped DC-DC Converter for PV and Battery Integrated Systems

A NEW ZVT ZCT PWM DC-DC CONVERTER

Performance Analysis and Comparison of Conventional and Interleaved DC/DC Boost Converter Using MULTISIM

HIGH-FREQUENCY PWM dc dc converters have been

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application

Modified Resonant Transition Switching for Buck Converter

THREE-PHASE converters are used to handle large powers

A SINGLE STAGE DC-DC CONVERTER FEASIBLE TO BATTERY CHARGING FROM PV PANELS WITH HIGH VOLTAGE STEP UP CAPABILITY

Analysis of Soft-switching Converters for Switched Reluctance Motor Drives for Electric Vehicles

International Journal of Current Research and Modern Education (IJCRME) ISSN (Online): & Impact Factor: Special Issue, NCFTCCPS -

HI-BRIDGE RESONANT SOFT-SWITCHED BOOST CONVERTER

THE demand for nonisolated high step-up dc dc converters

Fuzzy Controlled Capacitor Voltage Balancing Control for a Three Level Boost Converter

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP ( 81

Cost effective resonant DC-DC converter for hi-power and wide load range operation.

ONE OF THE MOST interesting areas for researchers in

HIGH EFFICIENCY BRIDGELESS PWM CUK CONVERTER WITH SOFT SWITCHING TECHNIQUE

Review and Analysis of a Coupled Inductor Based Bidirectional DC-DC Converter

A New Active Soft Switching Technique for Pulse Width Modulated Full Bridge DC-DC Converters

Two Stage Interleaved Boost Converter Design and Simulation in CCM and DCM

Dual mode controller based boost converter employing soft switching techniques

Hardware Testing, Designing and Simulation of Dual Input Buck-Buck DC-DC Converter Using H-Bridge Cells

A Pv Fed Buck Boost Converter Combining Ky And Buck Converter With Feedback

SSRG International Journal of Electrical and Electronics Engineering (SSRG-IJEEE) volume 1 Issue 10 Dec 2014

DSP-BASED CURRENT SHARING OF AVERAGE CURRENT CONTROLLED TWO-CELL INTERLEAVED BOOST POWER FACTOR CORRECTION CONVERTER

Soft-Switching DC-DC Converters Based on A Phase Shift Controlled Active Boost Rectifier Using Fuzzy Controller

Improvement of Light Load Efficiency for Buck- Boost DC-DC converter with ZVS using Switched Auxiliary Inductors

Two Stage on-board Battery Charger for Plug in Electric Vehicle Applications

PSIM Simulation of a Buck Boost DC-DC Converter with Wide Conversion Range

High Gain Interleaved Cuk Converter with Phase Shifted PWM

Lossless DC DC Boost Converter With High Voltage Gain For PV Technology

THE boost converter topology has been extensively used in

Hardware Implementation of Interleaved Converter with Voltage Multiplier Cell for PV System

SIMULATION OF HIGH BOOST CONVERTER FOR CONTINUOUS AND DISCONTINUOUS MODE OF OPERATION WITH COUPLED INDUCTOR

Transcription:

International Journal on Technical and Physical Problems of Engineering (IJTPE) Published by International Organization of IOTPE ISSN 2077-3528 IJTPE Journal www.iotpe.com ijtpe@iotpe.com March 2013 Issue 14 Volume 5 Number 1 Pages 132-137 SOFT SWITCHING ANALYSIS IN DC-DC BOOST CONVERTERS I. Iskender 1 M. Ghasemi 1 A. Mamizadeh 1 N. Genc 2 1. Electrical and Electronic Engineering Department, Engineering Faculty, Gazi University, Ankara, Turkey iresis@gazi.edu.tr, milad.ghasemi66@yahoo.com, mamizadeh@gazi.edu.tr 2. Electrical and Electronic Engineering Department, Engineering and Architecture Faculty, Yuzuncu Yil University, Van, Turkey, nacigenc@yyu.edu.tr Abstract- The boost topology is the most popular topology used in power factor correction circuits. The efficiency and performance of the boost converter depends on the switching frequency affecting the switching losses. At high frequency operations the switching losses of the converter is considerable and decreases the efficiency of the converter. To remove this problem the converter is designed to operate at soft switching mode operation. Soft switching mode operation also removes the problem of EMI which is a result of high frequency operation operating at hard switching. In this study, there are given five different topologies of DC-DC boost converters operating at soft switching. The hard switching operation of the corresponding converters are also given for the same load and operating conditions and the effect of the soft switching in increasing the efficiency of the converter is investigated. The given converters are analyzed and their efficiencies are compared. Auxiliary switches are also used in most soft switching DC-DC boost converter. Though these switches make the converter design a rather complicate they have considerable effects on the performance of boost converters. Keywords: DC-DC Converters, Soft Switching, Efficiency, Losses. I. INTRODUCTION The boost converter topology has been extensively used in various AC-DC and DC-DC applications. Also, the boost topology is used in numerous applications with battery-powered input to generate a high output voltage from a relatively low battery voltage. In modern AC-DC power supplies utilize power factor correction in order to minimize the harmonics in the input current drawn from the utility. The Boost topology is the most popular topology for power factor correction today but it has some disadvantages like high EMI due to reverse recovery of the boost diode and high switching losses caused by hard switching of the boost switch. Many variations of the original boost topology have been suggested to overcome these problems [5, 9]. The boost converter used for power factor correction operates at two different two operating modes of CCM and DCM depending on the operating frequency and the load conditions. Conventional hard switching pulse width modulation (PWM) converters, have disadvantages like high stress on device and objectionable EMI [7, 8, 11,12]. Increasing the switching frequency will reduce the volume and weight of switching mode power supplies. By increasing the operating frequency the power losses and EMI level of switch will increase too [1]. In modern switching mode power supplies the soft switching techniques are used to minimize the power losses of switches. These techniques have the advantages of high frequency operation with high efficiency and large power to volume ratio [2, 3, 6, 10]. New soft switching DC-DC converter uses a auxiliary circuit to compensate the power loss of hard switching converter. At soft switching method the properties of resonance operation are used. This is achieved using capacitors and inductors in the auxiliary circuits. At soft switching operations the devices of the converter change their on and off states either the voltage across them is zero (zero voltage switching ZVS) or when the current through them is zero (zero current switching ZCS) [2, 4]. Also, there are two techniques which are used in soft switching of DC-DC converters, ZVT and ZCT. The ZVT has often used in low and medium power applications [3, 8]. II. CONVENTIONAL DC-DC BOOST CONVERTER A boost converter has a step-up conversion ratio; hence the output voltage is always higher than the amplitude of the input voltage. The boost converter can be supplied from any suitable DC sources, such as fuel cell, photovoltaic cell, rectifiers and DC generators [2, 5, 10]. Figure 1 Show a typically classic DC-DC boost converter. The boost type topology is the most popular configuration because; the input current is the inductor current and is therefore easily programmed by current mode control. The boost inductor is in series with the ac power line so that the input current has smooth waveform especially at CCM resulting in much less EMI and reduced input filtering requirements. 132

Another advantage of this converter is the driving of the switch which has a common ground connection. Due to these advantages, the boost type topology has mostly been proposed in the literature for PFC applications [5, 8, 9]. The key principle that drives the boost converter is the tendency of an inductor to resist changes in current. In a boost converter, the output voltage is higher than the input voltage. When the switch is turned-on, the current flows through the inductor and energy is stored in it. When the switch is turned-off, the stored energy in the inductor tends to collapse and its polarity changes such that it adds to the input voltage. Thus, the voltage across the inductor and the input voltage are in series and together charge the output capacitor to a voltage higher than the input voltage. When a boost converter operates in continuous mode, the current through the inductor ( I L ) never falls to zero. Figure 1. A conventional boost converter III. SOFT SWITCHING DC-DC BOOST CONVERTERS This paper studies soft switching in DC-DC boost converters to analyze the effects of soft switching in converters. In this study, five different kinds of DC-DC boost converter are simulated and the power loss on the switches and the voltage and current of switches are concerned and compared. Beside these, the power efficiency of the converters is important. By reducing the power loss of switches, the power efficiency increases [1, 3, 5, 10]. A. Zero Transition (ZVT) in On-State Figure 2 shows the zero voltage transition on On- State technique. In this circuit the main switch turns on, at zero voltage switching condition and the auxiliary switch turns off at zero voltage switching. The advantage of this circuit is that the auxiliary switch under ZVS condition which leads to less power loss [1]. In this circuit, L=560µH, C=15µF, R=266Ω, V i =150V, V o =400V, f PWM =30kHz. The simulation results of Figure 2 are given in Figure 3. In this figure the voltage and current waveforms of the main and auxiliary switches and also the power losses of the main switch are given. Figure 3. wave form of zero voltage transition (ZVT) in on-state technique, (a) and current of main switch, (b) and current of auxiliary switch, (c) loss on main switch Figure 4 shows the power loss of switch at hard switching technique. Table 1 shows the power efficiency of the circuit in different load current. Figure 4. loss on main switch (hard switching) Table 1. efficiency of zero voltage transition in on-state circuit - SS - HS 1000 400 169.725 171.5 160 94.2 93.29 500 400 336.25 338.1 320 95.1 94.64 333 400 486.00 492.2 480 98.7 97.52 266 400 609.65 614.5 600 98.4 97.64 Figure 2. Zero voltage transition (ZVT) in on-state circuit A. B. Bidirectional Boost Converter In this circuit by using a resonant inductor and capacitors parallel with the switches, the ZVS technique is applied to switches and the main and auxiliary switches turns on and off on ZVS condition [2]. In this circuit, L=1mH, C o1 =10µF, C o2 =5µF, R= 53Ω, V i =200V, V o =400V, f PWM =30kHz. 133

Table 2. efficiency of bidirectional boost converter - SS - HS 76 400 2114.9 2136.5 2100 99.28 98.29 67 400 2416.4 2438.6 2400 99.32 98.41 59 400 2717.0 2741.8 2700 99.37 98.47 53 400 3018.1 3045.0 3000 99.40 98.52 Figure 5. Bidirectional boost converter The simulation results of Figure 5 are given in figure 6. In this figure the voltage and current waveforms of the main and auxiliary switches and also the power losses of the main switch are given. loss of the Bidirectional boost converter in hard switching technique is like the Figure 7. Table 2 shows the power efficiency of Bidirectional boost converter for different load resistance. C. Efficient Soft Switched Boost Converter This circuit uses either ZVS and ZCS in both switches. The efficient soft switched boost converter s nominal output power is 110 watt [3]. In this circuit, L=200µH, C o =3µF, R=110Ω, V i =30V, V o =110V, f PWM =100kHz. Figure 8. Efficient soft switched boost converter Figure 6. wave form of bidirectional boost converter technique, (a) and current of main switch, (b) and current of auxiliary switch, (c) loss on main switch Figure 7. loss of main switch (hard switching) in bidirectional boost converter Figure 9. wave form of efficient soft switched boost converter technique, (a) and current of main switch, (b) and current of auxiliary switch, (c) loss on main switch 134

Figure 10. loss on hard switching converter Figure 10 shows the power loss of switch in hard switching technique. The simulation results of figure 8 are given in Figure 9. In this figure the voltage and current waveforms of the main and auxiliary switches and also the power losses of the main switch are given. efficiency of the efficient soft switched boost converter is shown below. As the load resistance becomes small in value the power efficiency reaches to high values. Table 3. efficiency of efficient soft switched boost converter -SS -HS 242 110 51.60 52.10 50 96.89 95.96 173 110 72.10 72.88 70 97.10 96.04 135 110 92.50 93.00 90 97.29 96.77 110 110 112.95 113.60 110 97.36 96.83 D. ZVT PWM Boost Converter Figure 11 show a novel family of zero voltage transition boost converter that uses a resonant source to apply ZVT for switches [4]. In this circuit, L=0.91mH, C=5µF, R=160Ω, V i =150V, V o =400V and f PWM =100kHz. Figure 12. wave form of ZVT PWM boost converter technique, (a) and current of main switch, (b) and current of auxiliary switch, (c) loss on main switch Figure 13. loss in main switch (hard switching) Figure 11. ZVT PWM boost converter Figure 13 shows the power loss of switch in hard switching technique. Table 4 illustrates power efficiency of converter in different load resistance. The simulation results of Figure 11 are given in Figure 12. In this figure the voltage and current waveforms of the main and auxiliary switches and also the power losses of the main switch are given. E. Zero Transition (ZVT) in On-State Circuit with PID Controller Fifth boost converter topology, similar to case A. is Zero voltage transition (ZVT) in on-state with PID controller (Figure 14) [1]. In this circuit, L=560µH, C=15µF, R=266Ω, V i =150V, V o =400V, f PWM =30kHz. Table 4. efficiency of ZVT PWM boost converter -SS -HS 230 400 716.8 726.5 700 97.65 96.35 200 400 818.3 828.0 800 97.73 96.66 178 400 920.0 928.2 900 97.82 96.95 160 400 1021.4 1030.0 1000 97.91 97.04 The Figure 15 shows the wave forms of zero voltage transition (ZVT) in on- statewith control boost converter topology. In this figure the voltage and current waveforms of the main and auxiliary switches and also the power losses of the main switch are given. Hard switching power loss is illustrated in Figure 16. Table 5 illustrates power efficiency of converter in different load resistance. 135

Table 5. efficiency of zero voltage transition in on-state circuit with control boost converter - SS - HS 1000 400 169.72 171.5 160 94.2 93.29 500 400 336.25 338.1 320 95.1 94.64 333 400 486.00 492.2 480 98.7 97.52 266 400 609.65 614.5 600 98.4 97.64 Figure 14. Zero voltage transition (ZVT) in on-state circuit with PID controller IV. CONCLUSIONS The purpose of using soft switching techniques in DC-DC converter is to reduce the power loss of switches in converters. The simulation results verify the effect of the soft switching in reducing the switching losses. Among the different configurations of soft switching boost converters given in this study, the second type has the highest rate of power efficiency, the first and the fifth types have the lowest power efficiency. The number of elements used in converters is also important. This is due to the fact that using more elements makes the circuit design more complex and directly reduces the power efficiency. The number of elements also affects negatively the cost and the volume of the converter. ACKNOWLEDGEMENTS Authors wish to express their thanks to the Scientific Research Projects Unit of Gazi University (BAP) for supporting this study. Figure 15. wave form of zero voltage transition on On-state circuit with control boost converter technique, (a) and current of main switch, (b) and current of auxiliary switch, (c) loss on main switch Figure 16. loss of main switch (hard switching) REFERENCES [1] P. So Ri, P. Sang Hoon, W. Chung Yuen, J. Yong Chae, Low Loss Soft Switching Boost Converter, 13th International Electronics and Motion Control Conference (EPE-PEMC 2008), pp. 181-186, 2008. [2] S.S. Saha, Efficient Soft Switched Boost Converter for Fuel Cell Applications, International Journal of Hydrogen Energy, Vol. 36, No. 2, pp. 1710-1719, Jan. 2011. [3] K. Jun Gu, P. Seung Won, K. Young Ho, J. Yong Chae, W. Chung Yuen, High Efficiency Bidirectional Soft Switching DC-DC Converter, International Electronics Conference (IPCE), Sapparo, Japan, pp. 2905-2911, Jun. 2010. [4] M.L. Martins, H. Pinheiro, J.R. Pinheiro, H.A. Grundling, H.L. Hey, A Family of Improved ZVT PWM Converters Using an Auxiliary Resonant Source, Electronics and Control Research Group - GEPOC, CT - Federal University of Santa Maria - RS - Brazil, pp. 412-421, 2003. [5] N. Genc, I. Iskender An Improved Zero-- Transition Interleaved Boost Converter with High Factor, International Conference on Electrical and Electronics Engineering (ELECO 2009), pp. I-432-I-436, 2009. [6] A.J. Prabhakar, J.D. Bollinger, T.M. Hong, M. Ferdowsi, K. Corzine, Efficiency Analysis and Comparative Study of Hard and Soft Switching DC-DC Converters in A Wind Farm, IEEE Conference, pp. 2156-2160, 2008. 136

[7] T.W. Ching, K.U. Chan, Review of Soft Switching Techniques for High Frequency Switched Mode Converters, IEEE Vehicle and Propulsion Conference (VPPC), Harbin, China, pp.1-6, September 3-5, 2008. [8] N. Genc, I. Iskender, Steady State Analysis of a Novel ZVT Interleaved Boost Converter, International Journal of Circuit Theory and Applications, Vol. 39, Issue 10, pp. 1007-1021, 2011. [9] I. Iskender, N. Genc, Design and Analysis of a Novel Zero Transition Interleaved Boost Converter for Renewable Applications, International Journal of Electronics, Vol. 97, Issue 9, pp. 1051-1070, 2010. [10] J. Yungtaek, M.J. Milan, C. Yu Ming, High Factor Soft Switched Boost Converter, IEEE Transactions on Electronics, Vol. 21, Issue 1, pp. 98-104, 2006. [11] A. Karaarslan, I. Iskender, The Analysis of AC-DC Boost PFC Converter Based on Peak and Hysteresis Current Control Techniques, International Journal on Technical and Physical Problems of Engineering (IJTPE), Issue 7, Vol. 3, No. 2, pp. 100-105, June 2011. [12] H. Jangi Bahador, Design and Implementation of Factor Correction (PFC) Converter with Average Current Mode Control Using DSP, International Journal on Technical and Physical Problems of Engineering (IJTPE), Issue 6, Vol. 3, No. 1, pp. 92-95, March 2011. BIOGRAPHIES Ires Iskender received B.Sc. degree in Electrical Engineering from Gazi University, Ankara, Turkey in 1989. He received the M.Sc. and Ph.D. degrees in Electrical Engineering from Middle East Technical University, Ankara, Turkey in 1991 and 1996, respectively. From 1989 to 1996 he worked as a Research Assistant in Electrical and Electronics Engineering Department, Middle East Technical University, Ankara, Turkey. Since 1996 he has been with Department of Electrical Engineering, Gazi University, where he is currently an Associate Professor. His interests include renewable energy sources, energy conversion systems, power electronics and electrical machines. Milad Ghasemi was born in Urmia, Iran, in 1987. He received the B.Sc. degree from Urmia Branch, Islamic Azad University, Urmia, Iran in 2009. Currently, he is studying the M.Sc. program at Electrical and Electronics Engineering Department, Gazi University, Ankara, Turkey. Ali Mamizadeh was born in Tabriz, Iran, in 1980. He received his B.Sc. degree in Electrical Engineering from Sahand University of Technology, Tabriz, Iran in 2005. He received the M.Sc. degree in Electrical Engineering from Gazi University, Ankara, Turkey in 2010. He is currently studying Ph.D. program at Electrical Engineering and Electronics Department, Gazi University. Naci Genc received the B.Sc. degree from Electrical Education Department, Gazi University, Ankara, in 1999, the M.S. degree from Electrical and Electronics Engineering Department, Yuzuncu Yil University, Van, Turkey in 2002, and the Ph.D. degree from Electrical and Electronics Engineering Department, Gazi University, in 2010. He is currently working as an Assistant Professor at Electrical and Electronics Engineering Department, Yuzuncu Yil University. His current research interests include power factor correction converters, power quality, electrical machines and renewable energy. 137