Field Assembly and Installation

Similar documents
Instructions for Installation. S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection TABLE OF CONTENTS INTRODUCTION INSTALLATION

S&C Scada-Mate Switching Systems Outdoor Distribution Interrupter Replacement 14.4 kv through 34.5 kv

NSTRUCTIONS For Field Assembly and Installation

INSTRUCTIONS For Field Adjustment

WALK-BEHIND SPREADER 50 LB. CAPACITY Model 99623

RATCHET CABLE CUTTER

INSTRUCTIONS For Field Assembly and Installation

INSTALLATION INSTRUCTIONS

MPA-9000 Universal Ceiling Projector Mount Kit

Owner s Manual & Safety Instructions

INSTALLATION INSTRUCTIONS Small Flat Panel Mounts Model: F-Series

Shrinker and stretcher

INSTALLATION INSTRUCTIONS

Gared Pro-S Portable Backstop

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

00108/00110 INSTRUCTION MANUAL

Please read BOTH these Installation Instructions and the General Towing Instructions before attempting to install or operate this equipment.

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

VL GUIDE ON & BOW STOP INSTRUCTIONS

ETX Powered Loudspeaker Accessories

INSTALLATION INSTRUCTIONS

EKX Full-Range Loudspeaker Accessories

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

MODEL 83 Pail Handler

Yagi and Omni Antennas Installation Manual

INSTALLATION & OPERATING INSTRUCTIONS. REDCO LETTUCE KING I and LETTUCE KING IV

southpaw enterprises, inc.

MEC Auto-Mate Assembly Manual. For MEC 9000G/GN and 8567 Grabber Series

1904, 1904Pg, 1904PgSB, and 1906SB High Capacity Ratchet Knockout Drivers

Installation Instructions Jeep JL Front Grumper Product Number: GR4600 Application: 18+ JEEP JL

Specifications. Important Safety Information

Pow-R-Feed Systems Service Manual

MM750 Installation Instructions

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

Football Goal Posts MODEL SERIES: FGP400 and FGP600 series

Please read BOTH these Installation Instructions and the General Instructions prior to installing or operating this equipment.

FORD MOUNT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set

WARNING. Failure to observe these instructions could lead to severe injury or death.

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Loading Dock Safety Gate

OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL 1813 BENDING TABLE FOR 881 HYDRAULIC BENDER

OPERATION, PARTS & MAINTENANCE MANUAL MODELS HB73-16 HB97-18 HB97-16 HB97-12 HB HB HB HB145-18

Owner s Manual & Safety Instructions

S&C Series 2000 Circuit-Switchers Outdoor Transmission

WARNING VW Jetta New Installation Instructions BX3823. Serial Number

LC6X4WTM Security Wall Mount with Tilt for up to 60" Flat Screens with VESA 600mm x 400mm or less

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set #

M ACS Instructions

INSTRUCTION MANUAL DWX723-XE HEAVY-DUTY MITER SAW STAND FINAL PAGE SIZE : 8.5IN X 5.5IN

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Model Numbers: P/N Date TPS-200 POLE SAW ATT TPS-200. Supplier To The Outdoor Power Equipment Industry

LC200DS1 Double Stud Articulating Wall Mount for Flat Panel Screens up to 32" with up to 200mm x 200mm VESA Mounting Patterns

GENERAL OPERATIONAL PRECAUTIONS PRECAUTIONS ON USING DISC GRINDER

LEG CURL IP-S1315 INSTALLATION INSTRUCTIONS

Model MSPPWRTW Large Flat Panel Single Arm Wall Mount

VL GUIDE ON & VERTICAL BOW STOP INSTRUCTIONS

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

Models 2230 and 2240

INSTALLATION INSTRUCTIONS Lateral Shift Accessory Model: PAC-800

MTS-SP100. RENOGY Pole Mount System E Philadelphia St, Ontario, CA Version: 1.2

OPERATIONS MANUAL. Port-O-Slitter

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

1369 & 1379 MOUNT KITS

southpaw enterprises, inc.

MODULAR BUMPER INSTALLATION MANUAL

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

GENERAL OPERATIONAL PRECAUTIONS PRECAUTIONS ON USING CUT-OFF MACHINE

INSTALLATION INSTRUCTIONS

400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS

MANUAL METAL SHRINKER/STRETCHER

Standard Pole Mount Parabolic Antenna Mounting Instructions 3 ft. (90cm) & 4 ft. (120cm)

WARNING Honda Pilot Installation Instructions BX2244. Serial Number

INSTALLATION INSTRUCTIONS

FreshSesh, PowderHound & Big PowderHound

INSTALLATION & OWNER S MANUAL

ShorePort PWC Lift Instructions " x 138" Sandstone ShorePort " x 138" White ShorePort " x 138" Tan ShorePort

INSTALLATION INSTRUCTIONS

installation guide 1 GUIDE#: pwb-assault-004

INSTALLATION INSTRUCTIONS

340D & 350D SERIES FRAMELESS BYPASS BATH ENCLOSURES

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

ASSEMBLY AND CARE INSTRUCTIONS JUST FOR KIDS 355

Installation Instructions

Lumber Smith. Assembly Manual. If you are having problems assembling the saw and need assistance, please contact us at:

Rolling Curtain door Manual

INSTALLATION INSTRUCTIONS Y-Connector Accessory (For Multi-Dual Arm Mounting Systems) Model: KSA-1011

Gared Pro Portable Backstop

Tilting Flat Panel Wall Mount Installation Guide


FORD MOUNT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS UTV LIGHT BAR KIT Part Number: and Application: All UTV s*

Heavy Duty Ceiling Tilt Mount Installation Manual

12mm (Max) 6mm (Max) 82mm (Max) 12mm (Max) 6mm (Max)

WPS crew Doors Installation instructions

Sales & Service. JFK - Just For Kids. sasportonline.com. 135 Forestview Road 7879 Will Rogers Blvd.

Transcription:

S&C Circuit-Switchers Mark V a and Mark IV Outdoor Transmission Pre-insertion Inductors for Already-Installed Circuit-Switchers Field Assembly and Installation Table of Contents Section Page Section Page Introduction Qualified Persons....2 Read this Instruction Sheet....2 Retain this Instruction Sheet....2 Proper Application....3 Warranty....3 Safety Information Understanding Safety-Alert Messages....4 Following Safety Instructions....4 Replacement Instructions and Labels....4 Safety Precautions....5 Assembly and Installation Procedures Removal of Existing Pre-Insertion Resistors....6 Removal of Existing Earlier-Production Pre-Insertion Inductors...8 Installation of Knee-Brace Assembly on Integer Style Circuit-Switchers....12 Installation of High-Strength Insulators on Integer Style Circuit-Switchers....14 Replacement of Circuit-Closing Contacts on 34.5-kV through 69-kV Vertical-Break and Integer Style Circuit-Switchers....16 Assembly Procedure for 34.5-kV through 69-kV Vertical-Break and Integer Style Circuit-Switcher Pre-Insertion Inductors...17 Assembly Procedure for 115-kV and 138-kV Vertical-Break Style Circuit-Switcher Pre-Insertion Inductors...22 Assembly Procedure for 230-kV and 345-kV Center-Break Style Circuit-Switcher Pre-Insertion Inductors...26 Inspection Recommendations....29 a The pre-insertion inductor assemblies discussed herein are also suitable for use with equivalent models of Mark III and Mark IV Circuit-Switchers. August 27, 2012 S&C Electric Company Instruction Sheet 711-613

Introduction Qualified Persons Read this Instruction Sheet Retain this Instruction Sheet Ç WARNING The equipment covered by this publication must be installed, operated, and maintained by qualified persons who are knowledgeable in the installation, operation, and maintenance of primary distribution fusing equipment along with associated hazards. A qualified person is one who is trained and competent in: The skills and techniques necessary to distinguish exposed live parts from nonlive parts of electrical equipment. The skills and techniques necessary to determine the proper approach distances corresponding to the voltages to which the qualified person will be exposed. The proper use of the special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools for working on or near exposed energized parts of electrical equipment. These instructions are intended only for such qualified persons. They are not intended to be a substitute for adequate training and experience in safety procedures for this type of equipment. Thoroughly and carefully read this instruction sheet before installing pre-insertion inductors. Familiarize yourself with Safety Information on page 4 and 5. The latest version of this publication is available online in PDF format at www.sandc.com. Support/ Product Literature Library. This instruction sheet is a permanent part of your S&C Circuit-Switcher Mark V or Mark VI. These instructions should be stored in the Mark V or Mark VI Circuit-Switcher instruction manual holder. 2 S&C Instruction Sheet 711-613

Introduction Proper Application Ç CAUTION The equipment in this publication is only intended for use in switching and protection of capacitor banks. The application must be within the ratings furnished for the equipment. Ratings for the Mark V or Mark VI Circuit-Switcher are listed on the nameplate on the side of the Mark V or Mark VI CS-1A Switch Operator. These instructions are for field assembly and installation of S&C Pre-insertion Inductors to a Mark V or Mark VI Circuit-Switcher not originally furnished with this accessory, or to a Mark V Circuit-Switcher which was originally fur nished either with earlier-production pre-insertion induc tors or with now-discontinued S&C Pre-insertion Resistors. These instructions are applicable to standard-duty pre-insertion inductors on alreadyinstalled Circuit-Switchers of the following styles and voltage ratings: Integer Style rated 34.5 kv through 69 kv, Vertical-Break Style rated 34.5 kv through 138 kv, and Center-Break Style rated 230 kv and 345 kv; As well as to enhanced-duty pre-insertion inductors on already-installed Circuit- Switchers of the following styles and voltage ratings: Integer Style rated 34.5 kv through 69 kv, and Vertical-Break Style rated 34.5 kv through 138 kv. In single-bank and multiple-bank (back-to-back) capaci tor switching applications, pre-insertion inductors limit inrush current, overvoltage, and audible noise at the capacitor bank bus. Pre-insertion inductors also limit switching-surge overvoltages at remote transformers. Circuit-Switchers equipped with pre-insertion induc tors are capable of two consecutive closing operations 5 minutes apart, followed by one closing operation every hour. Warranty The warranty and/or obligations described in S&C s standard conditions of sale, as set forth in Price Sheet 150, plus any special warranty provisions, as set forth in the applicable product-line specification bulletin, are exclusive. The remedies provided in the former for breach of these warranties shall constitute immediate purchaser s or end user s exclusive remedy and a fulfillment of all seller s liability. In no event shall seller s liability to immediate purchaser or end user exceed the price of the specific product which gives rise to immediate purchaser s or end user s claim. All other warranties whether express or implied or arising by operation of law, course of dealing, usage of trade or otherwise, are excluded. The only warranties are those stated in Price Sheet 150, and THERE ARE NO EXPRESS OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ANY EXPRESS WARRANTY OR OTHER OBLIGATION PROVIDED IN PRICE SHEET 150 IS GRANTED ONLY TO THE IMME- DIATE PURCHASER AND END USER, AS DEFINED THEREIN. OTHER THAN AN END USER, NO REMOTE PURCHASER MAY RELY ON ANY AFFIRMATION OF FACT OR PROMISE THAT RELATES TO THE GOODS DESCRIBED HEREIN, ANY DESCRIP- TION THAT RELATES TO THE GOODS, OR ANY REMEDIAL PROMISE INCLUDED IN PRICE SHEET 150. The seller s warranties are contingent upon the installation and adjustment of S&C Circuit-Switchers Mark V and Mark VI in accordance with S&C s applicable instruction sheets, data sheets, and/or data bulletins. S&C Instruction Sheet 711-613 3

Safety Information Understanding Safety-Alert Messages There are several types of safety-alert messages which may appear throughout this instruction sheet as well as on labels and tags attached to the Circuit-Switcher and pre-insertion inductors. Familiarize yourself with these types of messages and the importance of the various signal words, as explained below. Ç DANGER DANGER identifies the most serious and immediate hazards which will likely result in serious personal injury or death if instructions, including recommended precautions, are not followed. Ç WARNING WARNING identifies hazards or unsafe practices which can result in serious personal injury or death if instructions, including recommended precautions, are not followed. Ç CAUTION CAUTION identifies hazards or unsafe practices which can result in minor personal injury or product or property damage if instructions, including recommended precautions, are not followed. NOTICE NOTICE identifies important procedures or requirements that, if not followed, can result in product or property damage if instructions are not followed. Following Safety Instructions If you do not understand any portion of this instruction sheet and need assistance, contact your nearest S&C Sales Office or S&C Authorized Distributor. Their telephone numbers are listed on S&C s website www.sandc.com. Or call S&C Headquarters at (773) 338-1000. Or call S&C Headquarters at (773) 338-1000; in Canada, call S&C Electric Canada Ltd. at (416) 249-9171. Thoroughly and carefully read this instruction sheet before installing pre-insertion inductors. NOTICE Replacement Instructions and Labels If you need additional copies of this instruction sheet, contact your nearest S&C Sales Office, S&C Authorized Distributor, S&C Headquarters. You can also download this instruction sheet from S&C s website www.sandc.com. It is important that any missing, damaged, or faded labels on the equipment be replaced immediately. Replacement labels are available by contacting your nearest S&C Sales Office, S&C Authorized Distributor, S&C Headquarters or S&C Electric Canada. 4 S&C Instruction Sheet 711-613

Safety Precautions Ç DANGER Mark V or Mark VI Circuit-Switchers operate at high voltage. Failure to observe the precautions below will result in serious personal injury or death. Some of these precautions may differ from your company s operating procedures and rules. Where a discrepancy exists, follow your company s operating procedures and rules. 1. QUALIFIED PERSONS. Access to substation switching equipment must be restricted only to qualified persons. See Qualified Persons on page 2. 2. SAFETY PROCEDURES. Always follow safe operating procedures and rules. 3. PERSONAL PROTECTIVE EQUIPMENT. Always use suitable protective equipment such as rubber gloves, rubber mats, hard hats, safety glasses, and flash clothing in accordance with safe operating procedures and rules. 4. SAFETY LABELS AND TAGS. Do not remove or obscure any of the DANGER, WARNING, CAU- TION, and NOTICE labels and tags. Remove tags ONLY if instructed to do so. 5. ENERGIZED COMPONENTS. Always consider all parts live until de-energized, tested, and grounded. 6. CIRCUIT-SWITCHER POSITION. Always confirm the open/close position of Circuit-Switchers by visually observing the position of the blades. Switches may be energized from either side and with the blades in any position. 7. MAINTAINING PROPER CLEARANCE. Always maintain proper clearance from energized components. 8. OPERATION. Circuit making and breaking is involved in the normal operation of this interrupter switch and, as a result, partway opening or closing is undesirable. To operate, follow the operating procedure as outlined in the appropriate instruction sheet for your model of Mark V or Mark VI Circuit-Switcher. S&C Instruction Sheet 711-613 5

Removal of Existing Pre-Insertion Resistors Remove the components indicated below. For pre-insertion resistors on 34.5 kv through 69-kV Vertical-Break Style and Integer Style Circuit-Switchers, refer to Figure 1, below. For pre-insertion resistors on 115-kV and 138-kV Ver tical-break Style Circuit-Switchers, refer to Figure 2, below. For pre-insertion resistors on 230-kV and 345-kV Cen ter-break Style Circuit-Switchers, refer to Figure 3, page 7. Circuit-closing tongue contact (remove when directed on page 16, then discard) Special C\v-inch washer (remove when directed on page 16, then retain) Circuit-closing jaw contacts Moving arcing-rod assembly Stationary arcing-rod assembly (remove and discard) Z\x 1331Z\v hex-head stainless-steel cap screws, lockwashers, and clamps (remove and retain) Resistor assembly Resistor mounting bracket Figure 1. Removal of existing pre-insertion resistors on 34.5-kV through 69-kV Vertical-Break and Integer Style Circuit-Switcher. Moving arcing-rod assembly Disconnect blade Stationary arcing-rod assembly (remove and discard) Resistor assembly Resistor mounting bracket and brace Figure 2. Removal of existing pre-insertion resistors on 115-kV and 138-kV Vertical-Break Style Circuit-Switcher. 6 S&C Instruction Sheet 711-613

Arcing-arm assemblies (remove and retain) Resistor assembly (as positioned for 345-kV Circuit-Switchers; remove and discard) Brain end Resistor assembly (as positioned for 230-kV Circuit-Switchers; remove and discard) Mounting adapter Mounting adapter Resistor assembly (remove and discard) Terminal end Blade clamp Jaw-contact disconnect blade Tongue-contact disconnect blade Figure 3. Removal of existing pre-insertion resistors on 230-kV and 345-kV Center-Break Style Circuit-Switchers. S&C Instruction Sheet 711-613 7

Removal of Existing Earlier-Production Pre-Insertion Inductors Remove the components indicated below. For upgraded earlier-production 5 millihenry pre-insertion inductors (inductors mounted vertically) on 34.5-kV through 69-kV Vertical-Break Style and Integer Style Circuit-Switchers, refer to Figure 4, on page 9. For earlier-production 5-millihenry pre-insertion inductors (inductors mounted at an angle) on 34.5-kV through 69-kV Vertical-Break Style and Integer Style Cir cuit-switchers, refer to Figure 5, on page 9. For earlier-production 10-millihenry pre-insertion inductors (inductors mounted vertically) on 34.5-kV through 69-kV Vertical-Break Style and Integer Style Cir cuit-switchers, refer to Figure 6, on page 10. For upgraded earlier-production 10-millihenry pre-insertion inductors (inductors mounted vertically) on 115-kV and 138-kV Vertical-Break Style Circuit-Switch ers, refer to Figure 7, on page 10. For earlier-production 10-millihenry pre-insertion inductors (inductors mounted at an angle) on 115-kV and 138-kV Vertical-Break Style Circuit-Switchers, refer to Figure 8, on page 11. 8 S&C Instruction Sheet 711-613

Circuit-closing tongue contact (remove when directed on page 16, then discard) Special C\v-inch washer (remove when directed on page 16, then retain) Stationary arcing-rod assembly Moving arcing-rod assembly Circuit-closing jaw contacts (remove and discard) Z\x 1331Z\v hex-head stainless-steel cap screws, lockwashers, and clamps (remove and retain) Inductor assembly Inductor mounting bracket Figure 4. Removal of existing upgraded earlier-production 5-millihenry pre-insertion inductors on 34.5-kV through 69-kV Vertical-Break Style and Integer Style Circuit-Switchers. Circuit-closing tongue contact (remove when directed on page 16, then discard) Special C\v-inch washer (remove when directed on page 16, and retain) Stationary arcing-rod assembly Circuit-closing jaw contacts Moving arcing-rod assembly Z\x 1331Z\v hex-head stainless-steel cap screws, lockwashers, and clamps (remove and retain) Inductor assembly Inductor mounting bracket Figure 5. Removal of existing earlier-production 5-millihenry pre-insertion inductors on 34.5-kV through 69-kV Vertical-Break Style and Integer Style Circuit-Switchers. S&C Instruction Sheet 711-613 9

Circuit-closing tongue contact (remove when directed on page 16, then discard) Special C\v-inch washer (remove when directed on page 16, then retain) Stationary arcing-rod assembly Moving arcing-rod assembly Circuit-closing jaw contacts Z\x 1331Z\v hexhead stainlesssteel cap screws, lockwashers, and clamps (remove and retain) Inductor assembly Inductor mounting bracket Figure 6. Removal of existing earlier-production 10-millihenry pre-insertion inductors on 34.5-kV through 69-kV Vertical- Break Style and Integer Style Circuit-Switchers. Stationary arcing-rod assembly Moving arcing-rod assembly Inductor assembly Inductor mounting bracket and support Figure 7. Removal of existing upgraded earlier-production 10-millihenry pre-insertion inductors on 115-kV and 138-kV Verti cal-break Style Circuit-Switchers. 10 S&C Instruction Sheet 711-613

Stationary arcing-rod assembly Moving arcing-rod assembly Inductor assembly Inductor mounting bracket Figure 8. Removal of existing earlier-production 10-millihenry pre-insertion inductors on 115-kV and 138-kV Vertical-Break Style Circuit-Switchers. S&C Instruction Sheet 711-613 11

Installation of Knee-Brace Assembly on Integer Style Circuit-Switchers NOTICE Integer Style Circuit-Switchers require the installation of a knee-brace assembly on the base of the Circuit-Switcher at the jaw-contact end and, in some instances, at the interrupter end. The following table summarizes the requirements for knee-brace assemblies. Rating, KV, Nom. No. of Interrupting Gaps Type of Pre-insertion Inductors Knee-Brace Assembly Required at Jaw-Contact Interrupter End End 34.5 & 46 1 Enhanced-Duty Yes No 69 1 Enhanced-Duty Yes No 69 1 40-mH, 5.5-ohm Standard-Duty Yes No 69 2 40-mH, 5.5-ohm Standard-Duty Yes Yes 69 2 Enhanced-Duty Yes Yes Step 1 Loosely assemble an upper clip angle and lower clip angle to each end of a knee brace using a B\, 11 3 1C\v galva nized hex-head cap screw, hardened flat washer, and hex nut. See Figure 9 on page 13, front view and top view. Step 2 Loosely attach the knee-brace assembly to the Circuit-Switcher base in accordance with Dimension A, using a B\, 11 3 1C\v galvanized hex-head cap screw, hardened flat washer, and hex nut. See Figure 9 on page 13, top view and front view. Step 3 Loosely attach the two support angles to the Circuit-Switcher mounting pedestal using two B\, 11 threaded rods, hardened flat washers, and hex nuts. See Figure 9 on page 13, front and side views. 12 S&C Instruction Sheet 711-613

Step 4 Loosely attach the lower clip angles to the support angles using B\, 11 3 1C\v galvanized hexhead cap screws, hard ened flat washers, and hex nuts. See Figure 9, front and side views. Step 5 Push the support angles up as far as they will go and make sure that there is no slack in the knee-brace assemblies. Verify the 28Z\v-inch dimension shown in Figure 9, side view. Tighten all hardware. A A Upper clip angle Lower clip angle Knee brace at jaw-contact end Knee brace at interrupter end (69-kV 2-gap Circuit-Switcher only) kv Dimension A, in Inches 34.5 33 46 33 69 43 Interrupter end TOP VIEW Circuit-Switcher base Upper clip angle Interrupter end Knee brace at interrupter end (69-kV 2-gap Circuit-Switcher only) Jaw-contact end Knee brace at jaw-contact end Lower clip angle 2Z\x 28Z\v B\, 1131C\v galvanized hex-head cap screw, hardened flat washer, and hex nut FRONT VIEW Mounting pedestal Support angle B\, 11 threaded rod, hardened flat washer, and hex nut SIDE VIEW 2Z\x Figure 9. Installation of knee-brace assembly. S&C Instruction Sheet 711-613 13

Installation of High-Strength Insulators on Integer Style Circuit-Switchers NOTICE Integer Style Circuit-Switchers rated 69 kv furnished with enhanced-duty preinsertion inductors require the installation of high-strength insulators at the jaw-con tact end of the Circuit-Switcher. Install the high-strength insulators using the following procedure. Step 1 Remove the four Z\x 13 3 1Z\v hex-head stainless-steel cap screws and lockwashers which secure the terminal adapter to the insulator mounting bracket. See Figure 10 on page 15, side view. Retain the terminal adapter and hardware. Step 2 Remove the two top B\, 11 hex nuts, lockwashers, and flat washers securing the insulator mounting weldment. See Figure 10 on page 15, View A-A. While supporting the insulator with an appropriate lifting device, remove the two B\, 11 3 1Z\x hex-head cap screws, lockwashers, and four serrated washers securing the insulator mounting weld ment to the switch base. Remove the insulator. Retain the hardware. Step 3 Remove the pivot rod from the insulator mounting weld ment and install it in the replacement insulator mounting weldment. See Figure 10 on page 15, View A-A. Attach the replace ment insulator mounting weldment and replacement insu lator mounting bracket to the high-strength insulator using eight B\, 11 3 1Z\v hex-head galvanized cap screws and lockwashers. Securely tighten the hardware. Step 4 Attach the high-strength insulator assembly to the switch base using two B\, 11 3 1Z\x hex-head cap screws, lock washers, and four serrated washers. See Figure 10 on page 15, View A-A. Secure the insulator mounting weldment with two B\, 11 hex nuts, lockwashers, and flat washers. Securely tighten the hardware. Step 5 Attach the terminal adapter to the insulator mounting bracket using four Z\x 13 3 1Z\v hex-head stainless-steel cap screws and lockwashers. See Figure 10 on page 15, side view. Securely tighten the hardware. Ç CAUTION Make sure that the Circuit-Switcher disconnect blades are correctly aligned with their jaw-contact assemblies. Failure to obtain correct alignment at each pole-unit can result in damage to the Circuit-Switcher. 14 S&C Instruction Sheet 711-613

As the Circuit-Switcher disconnect blade is closed, the cir cuit-closing tongue contact should engage each of the cir cuit-closing jaw-contact members with equal pressure, and the current-carrying tongue contact should enter between the current-carrying jaw-contact members with equal clearance on each side. The silver-surfaced area of the current-carrying tongue contact should center later ally with the silver-surfaced currentcarrying jaw-contact members, and the blade should rotate with slight pressure against the blade bumper stop and come to rest either on the stop or slightly above it. If adjustment of the jaw-contact assembly is necessary to obtain the described alignment, refer to the instruction sheet furnished for the specific Circuit-Switcher involved and proceed as outlined therein. Jaw-contact assembly Terminal adapter Z\x 1331Z\v hex-head stainlesssteel cap screws and lockwashers Insulator mounting bracket B\, 1131Z\v hex-head galvanized cap screws and lockwashers (not visible ) A A Remove standard-strength insulator (T.R. Number 216) and replace with high-strength insulator (T.R. Number 278) SIDE VIEW Insulator mounting weldment B\, 11 hex nut, lockwasher, and flatwasher B\, 1131Z\v hex-head galvanized cap screws and lockwashers (not visible ) Serrated washers VIEW A-A Pivot rod B\, 1131Z\x hex-head cap screws and lockwashers Switch base Figure 10. Installation of high-strength insulators. S&C Instruction Sheet 711-613 15

Replacement of Circuit-Closing Contacts on 34.5-kV through 69-kV Vertical-Break Style and Integer Style Circuit-Switchers NOTICE Vertical-Break Style and Integer Style Circuit-Switchers rated 34.5 kv through 69 kv require the installation of replacement circuit-closing contacts. Install the high-strength insulators using the following procedure. Step 1 Install the replacement circuit-closing jaw contacts on the jaw-contact terminal pad using two Z\x 13 3 1Z\v hex-head stainless-steel cap screws, lockwashers, and clamps. See Figure 11 on page 20, side view. Adjust the contact height to 9M\,6 Z\, inches as shown. Manually close the Circuit-Switcher and verify that the existing circuit-closing tongue contact engages both jaw contacts simultaneously. Securely tighten the hardware. Step 2 Remove the existing circuit-closing tongue contact and special C\v-inch washer from the end of the disconnect blade assembly. Discard the contact but retain the washer. See Figures 1, 4, 5, or 6, as appropriate. Step 3 Preassemble the replacement circuit-closing tongue con tact by installing a B\, 11 stainless-steel hex nut and a C\v 16 stainless-steel hex nut to the ends of the contact. See Figure 11 on page 20, Detail A. Screw the hex nuts all the way down onto the contact. Screw the circuit-closing tongue contact onto the circuit-closing tongue contact support so that the center of the half-circle saddle is concentric to the C\v 16 threaded end of the circuit-closing tongue con tact. See Figure 11 on page 21, View C-C. Step 4 Install the special C\v-inch washer with the radius edge towards the C\v 16 hex nut. See Figure 11 on page 20, Detail A. Remove the circuit-closing tongue contact support clamp and screw the C\v 16 threaded end of the circuit-closing tongue contact assembly all the way into the disconnect blade. Make sure that the half-circle saddle of the circuit-closing tongue contact support is in sliding contact with the disconnect blade pipe. It may be necessary to screw the circuit-closing tongue contact support in or out on the circuitclosing tongue contact so that the half-circle sad dle is in contact with the disconnect blade pipe. The cir cuit-closing tongue contact should be in a vertical position when the disconnect blade is being closed and the circuit-closing tongue contact is just making contact with the circuit-closing jaw contacts. See Figure 11 on page 20 and 21, side view and View D-D. Securely tighten the C\v 16 hex nut. Step 5 Attach the circuit-closing tongue contact support clamp to the circuit-closing tongue contact support using two Z\v 2031Z\v socket-head stainless-steel cap screws and securely tighten. See Figure 11 on page 20 and 21, View D-D. Install a B\zn 183C\, socket-head set screw and securely tighten. Securely tighten the B\, 11 hex nut up to the circuit-clos ing tongue contact support. See Figure 11 on page 20 and 21, Detail A. 16 S&C Instruction Sheet 711-613

Assembly Procedure for 34.5-kV through 69-kV Vertical-Break and Integer Style Circuit-Switchers Pre-Insertion Inductors Prior to assembly of component parts, thoroughly wire-brush aluminum mating surfaces. Immediately coat these surfaces with Penetrox A (available from Burndy Corporation). Repeat the following steps for each pole-unit. Step 1 Loosely attach the inductor mounting bar to the top of the jaw-contact terminal pad, using four Z\x 13 32Z\v hex-head stainless-steel cap screws, eight hardened flat wash ers, and four Z\x 13 hex nuts furnished. See Figure 11 on page 20 and 21, top and side views. Step 2 Loosely attach the inductor mounting brackets and spac ers to each side of the terminal adapter on the front insu lator stack, using four B\, 11 31C\v hex-head stainless-steel cap screws and four B\,-inch hardened flat washers. See Figure 11 on page 20 and 21, front and side views. Step 3 For 34.5-kV through 69-kV Circuit-Switchers furnished with 10-millihenry standardduty inductors: Remove and discard the two Z\x 13 31Z\x hex-head stainless-steel cap screws and two Z\x-inch hardened flat washers which secure the top inductor end cap to the inductor assembly. Attach the inductor lifting bracket to the top end cap using two Z\x 13 31Z\v hex-head stainless-steel cap screws and two hardened flat washers. Securely tighten the hardware. See Figure 11 on page 20 and 21, front and top views. Proceed to Step 4. For 34.5-kV and 46-kV Circuit-Switchers furnished with 10-millihenry or 18-millihenry enhanced-duty induc tors and 69-kV Circuit-Switchers furnished with 18-mil lihenry enhanced-duty inductors: Remove and discard the four Z\x 13 3C\v hex-head stainless-steel cap screws and four Z\x-inch hardened flat washers which secure the top inductor end cap to the inductor assembly. Attach the inductor lifting bracket to the top end cap using two Z\x 13 31Z\v hex-head stainless-steel cap screws and two hardened flat washers. Securely tighten the hardware. See Figure 11 on page 20, front and top views. Proceed to Step 4. For 69-kV Circuit-Switchers furnished with 40-milli henry standard-duty inductors or enhanced-duty induc tors: Attach the inductor lifting bracket to the top end cap of the inductor assembly using two Z\x 13 3 1Z\v hex-head stainless-steel cap screws and two hardened flat wash ers. Securely tighten the hardware. See Figure 11 on page 20 and 21, front and top views. Step 4 For 34.5-kV through 69-kV Circuit-Switchers furnished with 10-millihenry standardduty inductors: Lift the inductor assembly atop the inductor mounting bar and inductor mounting brackets. Attach the bottom end cap of the inductor assembly to the inductor mounting bar and inductor mounting brackets using the four studs on the end cap, four Z\x-inch hardened flat washers, and four Z\x 13 stainless-steel hex nuts. Securely tighten the hardware. See Figure 11 on page 20 and 21, side and front views. Proceed to Step 5. For 69-kV Circuit-Switchers furnished with 40-milli henry standardduty inductors and 34.5-kV through 69 kv Circuit-Switchers furnished with 10-millihenry, 18-millihenry, or 40-millihenry enhanced-duty induc tors: Lift the inductor assembly atop the inductor mount ing bar and inductor mounting brackets. Attach the bottom end cap of the inductor assembly to the inductor mounting bar and inductor mounting brackets using four Z\x 1332Z\v hex-head stainless-steel cap screws and four Z\x-inch hardened flat washers. Securely tighten the hardware. See Figure 11 on page 20 and 21, side and front views. S&C Instruction Sheet 711-613 17

Step 5 Securely tighten the four Z\x 13 32Z\v hex-head stainless-steel cap screws which attach the inductor mounting bar to the top of the jaw-contact terminal pad. See Figure 11 on page 20, side and top views. Step 6 Securely tighten the four B\, 11 3 1C\v hex-head stainless-steel cap screws which attach the inductor mounting brackets and spacers to each side of the terminal adapter on the front insulator stack. See Figure 11 on page 20 and 21, side and front views. Step 7 Remove the two Z\x 13 31Z\v hex-head stainless-steel cap screws and two hardened flat washers securing the lifting bracket to the top end of the inductor assembly. Step 8 Loosely attach the inductor jaw-contact assembly to the contact support tube using two C\, 16 3C\v hex-head stainless-steel cap screws and two serrated washers. See Figure 11 on page 20 and 21, side and front views. Step 9 Loosely attach the contact support tube to the inductor assembly top end cap using two support tube mounting clamps, four Z\x 13 31Z\v hex-head stainless-steel cap screws, and four Z\x-inch serrated washers. See Figure 11 on page 20, top view. Step 10 Ç CAUTION Make sure that the Circuit-Switcher disconnect blades are correctly aligned with their jaw-contact assemblies. Failure to obtain correct alignment at each pole-unit can result in damage to the Circuit-Switcher. As the Circuit-Switcher disconnect blade is closed, the cir cuit-closing tongue contact should engage each of the cir cuit-closing jaw-contact members with equal pressure, and the current-carrying tongue contact should enter between the current-carrying jaw-contact members with equal clearance on each side. The silver-surfaced area of the current-carrying tongue contact should center later ally with the silver-surfaced currentcarrying jaw-contact members, and the blade should rotate with slight pressure against the blade bumper stop and come to rest either on the stop or slightly above it. If adjustment of the jaw-contact assembly is necessary to obtain the described alignment, refer to the instruction sheet furnished for the specific Circuit-Switcher involved and proceed as outlined therein. Step 11 Manually close the Circuit-Switcher so that the circuit-closing tongue contact engages both contacts of the inductor jaw-contact assembly with equal pressure on each side. See Figure 11 on page 21, View B-B. Adjust the contact support tube to attain the dimension shown in Figure 11 on page 21, Detail A. Securely tighten the four Z\x 13 31Z\v hexhead stainless-steel cap screws which secure the support tube mounting clamps to the inductor assembly top end cap. 18 S&C Instruction Sheet 711-613

Step 12 Level the inductor jaw-contact assembly vertically while maintaining the circuit-closing tongue contact engaged between the inductor contacts with equal pressure. See Figure 11 on page 20 and 21, View B-B. Securely tighten the two C\, 16 3C\v hex-head stainless-steel cap screws which attach the inductor jaw-contact assembly to the contact support tube. See Figure 11 on page 20 and 21, side and front views. Step 13 Continue closing the Circuit-Switcher and verify that the circuit-closing tongue contact continues to engage both contacts with equal pressure as it exits the inductor con tact assembly. See Figure 11 on page 21, View B-B. If adjustment is necessary, proceed to Step 14. If adjustment is not neces sary, proceed to Step 15. Step 14 Loosen the C\v 16 stainless-steel hex nut which secures the circuit-closing tongue contact to the disconnect blade and loosen the two Z\v 20 31Z\v socket-head cap screws and B\zn 183C\, socket-head set screw which secure the circuit-closing tongue contact support to the disconnect blade. See Figure 11 on page 21, Detail A and View D-D. Rotate the circuit-closing tongue contact on the disconnect blade so that the tongue contact engages both contacts of the inductor jaw-contact assembly with equal pressure as it exits the assembly during closing. Securely tighten the C\v 16 stainless-steel hex nut, the two Z\v 20 31Z\v socket-head cap screws, and the B\zn 18 3C\, socket-head set screw. Step 15 Manually operate the Circuit-Switcher to recheck that the circuit-closing tongue contact is centered on the contacts of the inductor jaw-contact assembly during closing and opening. Lubricate the contact surfaces with S&C Catalog Number 9999-043 lubricant, furnished. See Figure 11 on page 21, Detail A. Ç CAUTION Contact surfaces must be properly lubricated. Failure to lubricate these surfaces can result in excessive con tact wear. Use Shell Gadus S2 U1000 2 Lubricant, S&C Catalog Number 9999-043, Shell Darina SD2, Dow 33, or equivalent. NOTICE The circuit-closing tongue contact does not simulta neously engage the inductor jaw-contact assembly and the circuit-closing jaw contacts. Step 16 Inspect the exterior finish of the inductor winding for damage or exposure of the fiberglass roving. Use the touch-up kit, furnished, to refinish any damaged surfaces. Refer to the Inspection Recommendations section on page 29. Should the inductor winding be damaged to the extent that coiled conductor is exposed, the inductor must be removed from service and replaced. S&C Instruction Sheet 711-613 19

Z\x 1331Z\v hex-head stain less-steel cap screws and serrated washers Support tube mounting clamp Z\x 13 31Z\v hex-head stainless-steel cap screws and hardened flat washers Z\x 13 32Z\v hex-head stainless-steel cap screws, hardened flat washers, and hex nuts TOP VIEW (For 34.5-kV through 69-kV Circuit-Switchers with 10 millihenry standard-duty inductors: Remove and discard existing Z\x 13 31Z\x hex-head stainless-steel cap screws and hardened flat washers) (For 34.5-kV and 46-kV Circuit-Switchers with 10-millihenry or 18-millihenry enhanced-duty induc tors and 69-kV Circuit-Switchers with 18-millihenry enhanced-duty inductors: Remove and discard exist ing Z\x 13 3C\v hex-head stainlesssteel cap screws and hardened flat washers) Inductor jaw-contact assembly See Detail A Circuit-closing tongue contact Current-carrying tongue contact Inductor lifting bracket Contact support tube End cap D NOTICE The circuit-closing tongue contact does not simultaneously engage the inductor jaw-contact assembly and the circuit-closing jaw contacts. Inductor assembly Disconnect blade D Circuit-closing jaw contacts Jaw-contact terminal pad Blade bumper stop Z\x 13 31Z\v hex-head stainless-steel cap screws, lockwashers, and clamps 9M\,-inches 6Z\,-inch SIDE VIEW Inductor mounting brackets Inductor mounting bar For 34.5-kV through 69-kV Circuit-Switchers with 10 millihenry standard-duty inductors: Z\x-inch hardened flat washers and Z\x 13 stainless-steel hex nuts For 69-kV Circuit-Switchers with 40-millihenry standard-duty inductors and 34.5-kV through 69-kV Circuit-Switchers with 10-millihenry,18-millihenry, or 40-millihenry enhanced-duty inductors: Z\x 13 32Z\v hex-head stainless-steel cap screws and hardened flat washers Figure 11. Assembly details of pre-insertion inductors for 34.5-kV through 69-kV Vertical-Break Style and Integer Style Circuit-Switchers. 10-millihenry inductors illustrated. 20 S&C Instruction Sheet 711-613

Circuit-closing tongue contact 1C\,-inch 6 Z\,-inch at 34.5 kv 1Z\,-inch 6 Z\,-inch at 46 kv C\v-inch 6 Z\,-inch at 69 kv Circuit-closing tongue contact entering inductor jaw-contact assembly B\, 11 stainless-steel hex nut C C\v 16 stainlesssteel hex nut B z z B Level inductor jaw-contact assembly vertically C Special C\v-inch washer radius toward nut Lubricate contact surfaces Circuit-closing tongue contact support DETAIL A Inductor jaw-contact assembly VIEW B-B Circuit-closing tongue contact exiting inductor jaw-contact assembly Circuit-closing tongue contact support clamp Circuit-closing tongue contact support Half-circle saddle C\v 16 threaded end of circuitclosing tongue contact Level circuit-closing tongue contact vertically VIEW C-C Inductor lifting bracket Circuit-closing tongue contact C\, 16 3C\v hex-head stainless-steel cap screws and serrated washers Circuit-closing jaw contacts Circuit-closing jaw contact B\, 11 31C\v hex-head stainless-steel cap screws and hardened flat washers Current-carrying jaw contacts Circuit-closing tongue contact support clamp Spacer B\zn 18 3 C\, socket-head set screw VIEW D-D Z\v 20 3 1Z\v socket-head cap screws FRONT VIEW Terminal adapter S&C Instruction Sheet 711-613 21

Assembly Procedure for 115-kV and 138-kV Vertical-Break Style Circuit-Switcher Pre-Insertion Inductors Prior to assembly of component parts, thoroughly wire-brush aluminum mating surfaces. Immediately coat these surfaces with Penetrox A (available from Burndy Corporation). Repeat the following steps for each pole-unit. Step 1 Loosely attach the inductor mounting bar to the top of the jaw-contact terminal pad, using four Z\x 13 32Z\v hex-head stainless-steel cap screws, eight hardened flat wash ers, and four Z\x 13 hex nuts furnished. See Figure 12, top and side views. Step 2 Refer to Figure 12, front view, and insert from the under side four B\, 11 31C\v hexhead stainless-steel cap screws and hardened flat washers through the tapped holes on each face of the terminal adapter. Loosely attach the inductor mounting brackets to the terminal adapter using four B\,-inch hardened flat washers and B\, 11 hex nuts furnished. See Figure 12 on page 22 and 23, front and side views. Stationary arcing-rod assembly Z\x 1331C\v hex-head stainless-steel cap screws and hardened flat washers (remove and retain existing Z\x 133C\v hex-head stainless-steel cap screws and hardened flat washer) Moving arcing-rod assembly Inductor lifting bracket Z\x 133 2Z\v hex-head stainless-steel cap screws, hardened flat washers, and hex nuts TOP VIEW Z\x 133C\v hex-head stainless-steel cap screws and hardened flat washers Moving arcing-rod support (see Detail B) Z\v 203 1Z\v socket-head stainless-steel cap screw 3Z\, Circuit-closing tongue contact End cap Pin Current-carrying tongue contact DETAIL A Circuit-closing jaw contact Current-carrying jaw contact A Inductor assembly Inductor mounting bar SIDE VIEW Blade bumper stop Inductor mounting brackets Z\x 133 2Z\v hex-head stainless-steel cap screws and hardened flat washers Jaw-contact terminal pad Figure 12. Assembly details of pre-insertion inductors for 115-kV and 138-kV Vertical-Break Style Circuit- Switchers. 22 S&C Instruction Sheet 711-613

Step 3 Attach the inductor lifting bracket to the top end cap of the inductor assembly using two Z\x 13 3C\v hex-head stainless-steel cap screws and hardened flat washers fur nished. See Figure 12 on page 22, top view. Securely tighten the hard ware. Step 4 Lift the inductor assembly atop the inductor mounting bar and the inductor mounting bracket. Attach the bottom end cap of the inductor assembly to the inductor mount ing bar and inductor mounting bracket using four Z\x 13 32Z\v hex-head stainless-steel cap screws and hardened flat washers. See Figure 12 on page 22, side view. Securely tighten the hardware. Step 4 Securely tighten the Z\x 13 32Z\v hex-head stainless-steel cap screws which attach the inductor mounting bar to the top of the jaw-contact terminal pad. Step 4 Securely tighten each B\, 11 hex nut attaching the induc tor mounting bracket to the terminal adapter, while hold ing the associated B\, 11 3 1C\v hex-head stainless-steel cap screw to prevent it from turning. See Figure 12, front view. Now tighten each B\, 11 hex nut Z\c additional turn. Step 7 Remove and retain the hardware securing the inductor lifting bracket to the top end cap of the inductor assembly and remove the lifting bracket. Drill ⁵\₁₆-inch diameter hole 3-inch deep. See Step 12, page 24. Stake casting after inserting pin Z\v 2031Z\v socket-head stainless-steel cap screw DETAIL B Moving arcing-rod support Level horizontally kv Dimension A, in Inches 115 12Z\x 138 14 Current-carrying tongue contact Circuit-closing jaw contact B\, 1131C\v hex-head stainless-steel cap screws, hardened flat washers, and hex nuts A A Lubricate contact surfaces Moving arcing rod Stationary arcing rod 0 to Z\,-inch max. gap Position of moving arcing rod when disconnect blade is fully closed but not rotated Current-carrying jaw contact Terminal adapter FRONT VIEW S&C Instruction Sheet 711-613 23

Step 8 Remove and retain the appropriate Z\x 13 3C\v hex-head stainless-steel cap screw and hardened flat washer from the top end cap of the inductor assembly. See Figure 12 on page 22, top view. Loosely attach the stationary arcing-rod assem bly to the top end cap using two Z\x 13 3 1C\v hex-head stainless-steel cap screws and hardened flat washers fur nished. Insert a Z\x 13 3C\v hex-head stainless-steel cap screw and hardened flat washer into each of the other three tapped holes in the top end cap; securely tighten each of these screws. Step 9 Ç CAUTION Make sure that the Circuit-Switcher disconnect blades are correctly aligned with their jaw-contact assemblies. Failure to obtain correct alignment at each pole-unit can result in damage to the Circuit-Switcher. As the Circuit-Switcher disconnect blade is closed, the cir cuit-closing tongue contact should engage each of the cir cuit-closing jaw-contact members with equal pressure, and the current-carrying tongue contact should enter between the current-carrying jaw-contact members with equal clearance on each side. The silver-surfaced area of the current-carrying tongue contact should center later ally with the silver-surfaced currentcarrying jaw-contact members, and the blade should rotate with slight pressure against the blade bumper stop and come to rest either on the stop or slightly above it. If adjustment of the jaw-contact assembly is necessary to obtain the described alignment, refer to the instruction sheet furnished for the specific Circuit-Switcher involved and proceed as outlined therein. Step 10 Loosely attach the moving arcing-rod support to the disconnect blade in accordance with the 3Z\,-inch dimen sion shown in Figure 12 on page 22, Detail A. Step 11 Manually close the Circuit-Switcher so that the minimum metal-to-metal clearance between the current-carrying tongue contact and the nearest circuit-closing jaw contact is equal to Dimension A, as shown in Figure 12 on page 22 and 23, side view and front view. With the Circuit-Switcher disconnect blade in this position, rotate the moving arcing rod to the horizontal position, as shown in Figure 12 on page 23, front view. Fully tighten the two Z\v 20 31Z\v socket-head stainless-steel cap screws. Apply Loctite A, furnished, to the two cap screws. Step 12 Using the tapped hole in the moving arcing-rod support as a guide, drill a B\zn-inch diameter hole, 3 inches deep in the dis connect blade. See Figure 12 on page 23, Detail B. Drive in the groove pin furnished, then stake the support casting. 24 S&C Instruction Sheet 711-613

Step 13 Manually close the Circuit-Switcher so that the minimum metal-to-metal clearance between the current-carrying tongue contact and the nearest circuit-closing jaw contact is equal to Dimension A, as shown in Figure 12 on page 22, side view and front view. Now adjust the stationary arcing-rod assembly to attain a 0-inch to Z\,-inch gap between the sta tionary arcing rod and the moving arcing rod. See Figure 12 on page 22, front view. Securely tighten the two Z\x 13 3 1C\v hex-head stainless-steel cap screws. Lubricate the contact sur faces with an appropriate lubricant, such as S&C Catalog Number 9999-043 or equivalent. See Figure 12 on page 23, front view. Ç CAUTION Contact surfaces must be properly lubricated. Failure to lubricate these surfaces can result in excessive contact wear. Use Shell Gadus S2 U1000 2 Lubricant, S&C Catalog Number 9999-043, Shell Darina SD2, Dow 33, or equivalent. Step 14 Manually operate the Circuit-Switcher to recheck the alignment between the moving and stationary arcing rods. During closing, the clearance between the moving and sta tionary arcing rods should be 0 inch to Z\,-inch, as shown in Figure 12 on page 22, front view. Readjust the stationary arcing-rod assembly, if necessary, then securely retighten the cap screws on the inductor assembly end cap. Step 15 Verify that the minimum metal-to-metal clearance between the stationary arcing rod and the nearest current-carrying jaw contact is equal to Dimension A, as shown in Figure 12 on page 22, front view. If necessary loosen the four Z\x 13 3 2Z\v hex-head stainless-steel cap screws which secure the inductor assembly to the inductor mounting bar and inductor mounting bracket and reposition the inductor assembly; then securely retighten the cap screws. Make sure that the 0-inch to Z\,-inch gap between the stationary arcing rod and the moving arcing rod shown in Figure 12 on page 22, front view, has been maintained. Step 16 Inspect the exterior finish of the inductor winding for damage or exposure of the fiberglass roving. Use the touch-up kit, furnished, to refinish any damaged surfaces. Refer to the Inspection Recommendations sec tion on page 29. Should the inductor winding be damaged to the extent that coiled conductor is exposed, the inductor must be removed from service and replaced. S&C Instruction Sheet 711-613 25

Assembly Procedure for 230-kV and 345-kV Center-Break Style Circuit-Switcher Pre-Insertion Inductors Prior to assembly of component parts, thoroughly wire-brush aluminum mating surfaces. Immediately coat these surfaces with Penetrox A (available from Burndy Corporation). Repeat the following steps for each pole-unit. astep 1 With the Circuit-Switcher in the fully closed position, attach the inductor mounting adapters as follows: (a) Draw guide marks at the juncture of the tongue-con tact disconnect blade and its associated blade-hinge assembly to use as a reference so that, during this step, the disconnect-blade contact alignment (longi tudinal and rotational) can be maintained. Next, remove the tongue-contact disconnect-blade clamp and replace it with an inductor mounting adapter using four Z\x 13 31Z\x hex-head stainless-steel cap screws, serrated washers, and split lockwashers. Make sure that the inductor mounting surface of the adapter is level (parallel to the pole-unit base), and that the disconnect blade is aligned with its blade-hinge assembly in accordance with the guide marks previously drawn. Then fully tighten the cap screws. (For 345-kV Circuit-Switchers, repeat this procedure for the jaw-contact disconnect blade.) (b) For 230-kV Circuit-Switchers, attach a second induc tor mounting adapter to the jaw-contact disconnect blade using the blade clamp which was removed as directed in (a) above positioned as shown in Figure 13 on page 28, side view. Make sure that the inductor mounting surface of the adapter is level. Then fully tighten the cap screws. Manually open and then reclose the Circuit-Switcher and verify, during the closing stroke, that the circuit-clos ing contact members are in proper mesh and that the cur rent-carrying tongue contact enters the current-carrying jaw contact evenly with no tendency to clash against either side. Should adjustment be necessary, realign the tongue-contact disconnect blade only, as directed in the instruction sheet furnished for the Circuit-Switcher. Step 2 Mount the two inductor assemblies on the inductor mounting adapters, using four Z\x 13 stainless-steel hex nuts and hardened flat washers. Securely tighten the nuts. Step 3 Attach the arcing-arm assemblies to the inductor assem blies as shown in Figure 13 on page 28, side view, using four Z\x 13 31Z\x hex-head stainless-steel cap screws, serrated washers, and split lockwashers. Mounting holes of inductor arm assemblies are slotted to permit adjustment of arm. a Step applies only if pre-insertion inductors are being added to an installation not originally furnished with now-discontinued pre-inser tion resistors. 26 S&C Instruction Sheet 711-613

Step 4 Manually open the Circuit-Switcher to the point where the arcing-arm tips are aligned vertically, i.e., tip over tip. At this point of minimum separation, adjust the arms to obtain a clearance equal to Dimension A, as shown in Fig ure 13 on page 28, side view. If necessary, use the special shims (fur nished) between the arcing-arm assemblies and the inductor assemblies to attain this clearance. Continue opening the Circuit-Switcher until reaching the point where the metal-to-metal separation between the disconnect blades is equal to Dimension B, as shown in Figure 13 on page 28, top view. Then, while maintaining this dis connect-blade positioning, loosen the four Z\x 13 31Z\x hex-head stainless-steel cap screws which secure each arcing-arm assembly and adjust the angle of both arcing arms by equal amounts to obtain a separation equal to Dimension C, as shown in Figure 13 on page 28, top view. Recheck to make sure that Dimension A has been maintained; if necessary, repeat the above procedure. Then fully tighten the Z\x 13 31Z\x hex-head stainless-steel cap screws which fasten the arcing-arm assemblies to the inductor assemblies. astep 5 At the location indicated in Figure 13 on page 28, side view, remove one of the Z\x 13 31Z\x hex-head stainless-steel cap screws from the blade clamp at the jaw-contact end of the disconnect blade (not applicable to 345-kV Circuit-Switch ers). At the inside corner of the bolt cavity, drill a B\zn-inch diameter hole through the clamp and the wall of the dis connect blade aim the drill to enter the blade on center. Insert the B\zn-inch diameter Spirol pin furnished. Replace and fully tighten the clamp bolt. Step 6 Inspect the exterior finish of the inductor winding for damage or exposure of the fiberglass roving. Use the touch-up kit, furnished, to refinish any damaged surfaces. Refer to the Inspection Recommendations sec tion on page 29. Should the inductor winding be damaged to the extent that coiled conductor is exposed, the inductor must be removed from service and replaced. a Step applies only if pre-insertion inductors are being added to an installation not originally furnished with now-discontinued pre-inser tion resistors. S&C Instruction Sheet 711-613 27