KiloStream Data Sheet

Similar documents
SIN 57 Issue 2.4 May 2018

) #(2/./53 $!4! 42!.3-)33)/.!4! $!4! 3)'.!,,).' 2!4% ()'(%2 4(!. KBITS 53).' K(Z '2/50 "!.$ #)2#5)43

Superseded by a more recent version INTERNATIONAL TELECOMMUNICATION UNION

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION OVER THE TELEPHONE NETWORK

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION NETWORK: INTERFACES

)454 6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU

INTERNATIONAL TELECOMMUNICATION UNION

ANALOG AND DIGITAL PHYSICAL INTERFACES

) ,4)0,%8 $4%$#% ).4%2&!#% &/2 53%2 #,!33%3 05",)# $!4!.%47/2+3 ).4%2&!#%3. )454 Recommendation 8 INTERNATIONAL TELECOMMUNICATION UNION

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308

RECOMMENDATION ITU-R BT.1302 *

Miniature Synchronous Multipoint Modems

King Fahd University of Petroleum & Minerals Computer Engineering Dept

1160 Stereo Power Amplifier

RECOMMENDATION ITU-R BT *

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

Suppliers' Information Note. BT Metallic Path Facility. Interface Description

EUROPEAN pr ETS TELECOMMUNICATION February 1996 STANDARD

CX-A6 Amplifier Installation & User Guide V8.0

CX-A6 Amplifier Installation & User Guide V9.0

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308

DPA-1200 ORDERCODE D4180 DPA-2400 ORDERCODE D4181 DPA-3400 ORDERCODE D4182

OPERATION MANUAL INSTALLATION AND KHS.1. 2-Channel High-Speed Data Module. Kilomux I/O Module. The Access Company

3050 Stereo Power Amplifier

LBI Installation & Operation

8450 Series CellGuard TM Power / VSWR Monitors

AMU-214 Auxiliary Monitor Unit Operations Manual

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem

Q-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual

Appendix A. Datum Systems PSM-2100/512 Satellite Modem. Technical Specification

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

SMARTSCAN 8000 SERIES LIGHT CURTAIN Series Safety Light Curtain Installation Sheet (CD159/030210)

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor

(

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A

Plug power input. Socket power output

M-0418 REV:0

8000 Series Safety Light Curtain Installation Sheet ( CD159/ )

2302 Battery Simulator 2306, 2306-PJ Battery/Charger Simulators

With Audible Detect Signal

Stat-4 Stat-8 Stat-24

9600 bps, Dual Modem 170 Card Private Wire Only

TECHNICAL TBR 2 BASIS for January 1997 REGULATION

JOINT STOCK COMPANY. MULTICHANNEL RECEIVER RI-4010M (version RM ) User guide

USER'S MANUAL. Model : K

T6M Base Station User Guide

TM-800 Main Station. Instruction Manual. TELIKOU Systems All Rights Reserved

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

SPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem

Battery Simulator Battery/Charger Simulators

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

Technical Equipment Specification

SOUNDMASTER VF 400 MOS-FET POWER AMPLIFIER OWNERS MANUAL

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

Single Channel Radio Mic System USER MANUAL. WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System

Frequency Agility and Barrage Noise Jamming

Atrie WireSpan 600/610 MODEM User's Manual

MODEL T-110 SERIES OPERATION MANUAL

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

Technical data. General specifications V DC No-load supply current I 0. typ. 50 ma Power consumption P 0

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

GFL-1000 User Manual Ground Fault Locator

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

TWS 16 BT UHF wireless system. user manual

MGE TM Galaxy TM , 60 Hz kva

PULSE INPUT MODULE PI232/PI272 USER S MANUAL

VC-4/4A, VC-8/8A, VC-16

SYSTEM SENSOR WIRELESS REMOTE INDICATOR PRODUCT SPECIFICATION

Digital Electronic Thermostat With RF

User Manual. ilive 2 Wireless microphone system

Aqua-Gen 3PV INSTRUCTIONS

FLEXRISE2 VERSION. 2 LEG / 2 MOTOR ELECTRIC TABLE BASE (36 to 72 ) **PATENT PENDING**

RFL-SHFI-M Module. C37.94 Short Haul Fibre Interface For Milegate. User Manual

1995 Metric CSJ , etc. SPECIAL SPECIFICATION ITEM D-I Muldem (Drop/Insert Multiplexor/Demultiplexor)

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem

Radio Control Installation and Operating Instructions System 4

Multiturn absolute encoder

USER MANUAL ENGLISH 1450 COIN COUNTER & SORTER

MODEL L-1200 SERIES OPERATION MANUAL

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

M9606. FSK Modem. 5C Communications Inc.

Installation & Operation Manual for D2066 Quasar Receiver

Interface converter G kbit/sec

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

OWNER S MANUAL 311DRH 311DR 221R 211R 200R 31LT 31IT 32BT 32IT 31HT 31XT

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

Langton House, 19 Village Street, Harvington, Worcestershire. WR11 8NQ Tel: Fax: RTB5211 UHF FULL DUPLEX BASE STATION

M-Bus Master MultiPort 250L Installation and User Guide

HITEK POWER OLH10K SERIES

IR Radiator. Configuration. Architectural Specification. Highlights. Used With

FO-TX 2-EC FO-TX 2-OPT FO-RX 2-EC

FOM-5A, 6A Asynchronous Fiber Optic Modems

STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

BASIC PARAMETERS FOR THE MEASUREMENT OF ERROR PERFORMANCE AT BIT RATES BELOW THE PRIMARY RATE

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

Transcription:

KiloStream Data Sheet KiloStream speeds The choice of interfaces and speeds shown below enable a wide variety of equipment conforming to CCITT* standards to be connected. Speeds and interfaces Speed kbit/s X.21 X.21 bis (V.24) X.21 bis (V.35) 2.4 * * 4.8 * * 9.6 * * 19.2 * * 48 * * 64 * Access to the KiloStream service is via a Network Terminating Unit (NTU) on the customer's premises. This NTU is linked to a KiloStream network multiplexor located at the local exchange. At speeds up to and including 48kbit/s, a KiloStream circuit offers a built in remote diagnostics capability. This allows BT to monitor performance and to check for problems while the line is in operation. KiloStream technical data KiIoStream X.21 The X.21 interface is a 15 way D-type socket (female) and is available at all speeds. The offering is set as shown below with no variable options. 2.4-48kbit/s structured circuits Local and remote loops may be activated by means of buttons on the NTU or by the Data Terminal Equipment (DTE). Remote loops Remote loops can be applied from the DTE if the following conditions are satisfied: - The Control (Circuit C) is OFF - The DTE sends a continuous 11001100 pattern - This pattern must be preceded by at least one Binary 1 within the preceding 16 bit intervals - Loop activation is indicated by return of the 11001100 sequence. The DTE responds to loop activation within 0.7 seconds by an OFF to ON transition on the Control (Circuit C) - The loop will subsequently be removed when an ON to OFF transition is placed on the Control (Circuit C) by the DTE. Page 1 of 1

Local loops Local loops can be applied from the DTE if the following conditions are satisfied: - The Control (Circuit C) at both ends is OFF - The DTE sends on the T circuit a binary pattern consisting of 11001100 with control OFF - This pattern must be preceded by a continuous Binary 0 pattern persisting for at least 24 bit intervals - Loop activation is indicated by return of the 11001100 sequence. The DTE responds to loop activation within 0.7 seconds by an OFF to ON transition on the Control (Circuit C) - The loop will subsequently be removed when an ON to OFF transition is placed on the Control (Circuit C) by the DTE. The local loop pattern is referred to as Local Loop Code A. All KiloStream NTUs will respond to this code, although those with an LCD display will also respond to Local Loop Code B. This code consists of a continuous 11110000 pattern. All other conditions are the same as for Local Loop Code A activation. 64kbits/unstructured circuits On X.21 unstructured circuits test loops can only be applied at the NTU. X.21 Interchange circuits X.21 CCITT circuit designation Direction of signalling Circuit description PIN number A B G Common return 8 - T DTE-NTU Transmit data 2 9 R NTU-DTE Receive data 4 11 C DTE-NTU Control 3 10 I NTU-DTE lndication 5 12 S NTU-DTE Signal element timing 6 13 Circuits working at 64kbit/s data rate are unstructured' and use G, T, R and S circuits. However, I circuit will be permanently ON except under fault conditions KiloStream X.21 bis (V.24 and V.35) These interfaces allow connection of data terminal equipment which is designed for interfacing to synchronous V series modems. V.24 presentation can be supplied for speeds up to and including 19.2kbit/s using a 25 way D-type socket (female). There are further sub-options on electrical interchange circuits 106, 107 and 108/1. (See options table). V.35 presentation can only be supplied for a speed of 48kbit/s, using a MRAC 34S-J2 socket (female). There are further sub-options on electrical interchange circuits 106 and 107. (See Options for X2l bis table below) Local and remote loops Remote and local loops may be activated from either the NTU or the DTE. Remote loops are controlled via circuit 140. If this circuit is ON, a remote loop is applied. When the condition on circuit 140 is removed, the loop is deactivated. Local loops are controlled in a similar manner; but utilise circuit 141. Page 2 of 2

X.21 bis (V.24) Interchange circuits X.21 bis (2.4-9.6kbit/s and 19.2kbit/s) CCITT circuit Direction of Circuit PIN number number signalling description 102 - Common return 7 103 DTE-NTU Transmit data 2 104 NTU-DTE Receive data 3 105 DTE-NTU Request to send 4 106 NTU-DTE Ready for sending 5 107 NTU-DTE Data set ready 6 108/1 DTE-NTU Connect data set to line 20 109 NTU-DTE Data channel received line 8 signal detector 114 NTU-DTE Transmitter signal element 15 timing 115 NTU-DTE Receiver signal 17 element timing 140 DTE-NTU Remote loopback 21* 141 DTE-NTU Local loopback 18* 142 NTU-DTE Test indicator 25* It these circuits are not used by the DTE they must be correctly terminated or disconnected (see note 1) X.21 bis (V.35) Interchange circuits X.21 bis (48kbit/s only) CCITT circuit Direction of Balanced Unbalanced Circuit PIN designation number signalling circuit circuit description A T 102 - * Common return B 103 DTE-NTU * Transmit data P S 104 NTU-DTE * Receive data R T 105 DTE-NTU * Request to send C 106 NTU-DTE * Ready for sending D 107 NTU-DTE * Data set ready E 109 NTU-DTE * Data channel received line signal detector F 114 NTU-DTE * Transmitter signal Y AA(a)** element timing 115 NTU-DTE * Receiver signal element timing V X 140 DTE-NTU * Remote loopback N* 141 DTE-NTU * Local loopback L* 142 NTU-DTE * Test indicator NN*(m)** It these circuits are not used by the DTE they must be correctly terminated or disconnected (see note 1) **Letters in brackets ( ) indicate alternative connector labelling Note 1: Interchange circuits not used by the DTE Page 3 of 3

It is important that all conductors connected to pins listed in the table are either: a) Correctly terminated at the DTE as specified in relevant CCITT* recommendation at all times b) Disconnected on the interface cable at the NTU connector end. This avoids spurious conditions on interchange circuits causing incorrect operation of the NTU. This is especially important on loop control circuits 140 and 141. X.21 (V.24 and V.35) sub-options The table below shows the various option codes used by BT to ensure a new circuit is correctly configured. The first options shown in each case are the most likely to be used. Options for X.21 bis CCITT Interchange circuit with an interface option X.21 bis (V.24) Circuit 106 Ready for send delay (RFS) Circuit 108/1 Connect data set to line (CDSTL) Circuit 107 Data set ready (DSR) X.21 bis(v.35) Circuit 106 Ready for send delay (RFS) Circuit 107 Data set ready (DSR) BT suggested defaults Zero delay Permanently ON To follow CDSTL Zero delay To follow CDSTL Customer alternatives l0-2oms delay Controlled by terminal equipment Set OFF under fault conditions 10-2Oms delay Set OFF under fault conditions On site termination equipment Network Terminating Unit (NTU) A KiloStream circuit is provided with an NTU at either end. These units provide the correct interfaces to CCITT * standards and are connected to a mains power supply The NTU consists of a single printed circuit card which can be housed in one of two ways. Single unit The NTU is housed in a moulded plastic case which is designed to rest on a desk top. The customer's Data Terminal Equipment interface is located at the rear of the case, together with a line connection card and a 3 metre long mains cable complete with a BS1363, 3 pin moulded plug top. Multiple installation The NTU can be mounted in a KiloStream shelf. The shelf is in 19 inch rack equipment practice, 6 vertical units (VUs) high. It can provide for up to 12 KiloStream circuits of any combination of types. Power supply Single unit The socket must meet the requirements of British Standards Specifications BS1363 and be wired in accordance with the 15th edition of the lee wiring regulations. Subject to building fire regulations, this unit must be powered at all times. Shelf Mounted The external power supply should be connected on installation and the shelf power unit switched ON. Again, subject to building fire regulations, this unit must be powered at all times. Page 4 of 4

Shelf mounted NTU specifications Weight Power requirements Power consumption H 261 mm x W 25mm x D 248mm 0.55kg 240V at 50Hz Approximately 7 watts (100 watts fully loaded shelf) Single unit specifications Weight Power requirements Power consumption Operating environment H 55mm x W 251 mm x D 274mm 2.9kg 240V RMS AC -10% to +6% 45Hz to 55Hz Approximately 8 watts 5 0 C to 55 0 C Relative humidity 90% non-condensing (max) at a temperature range of 20-45 0 C KiloStream shelf specifications Weight Power Requirements Power consumption Operating environment H 266mm x W 482mm x D 269mm (6VU) 16.12kg 240V RMS AC 45Hz to 55Hz Approximately 100 watts fully equipped 5 0 C to 55 0 C Relative humidity 90% non-condensing (max) at a temperature range of 20-45 0 C The shelf can also be housed in one of two ways Housing Number of shelves/circuits Case Up to 1/12 H 270mm W 540mm D 400mm Cabinet Up to 4/48 H 1730mm W 600mm D 600mm Customer owned rack or cabinet Description A metal case with a perspex front cover designed to rest on a desk top Power, line & data interface connectors are provided at the rear. A metal cabinet with full length doors fitted front and rear. Power and line connectors are permanently cabled in Interface connectors are situated at the bottom of the cabinet at the front or as advised The shelf can be fitted into any suitable l9in practice rack subject to BT approval. KiloStream performance The current technology and environment of digital networks worldwide, means it is impossible to provide a completely permanent and error-free path between two network nodes or terminations, and occasionally errors will occur. CCITT* have evolved a standard for network performance and availability known as G821, which takes account of adverse factors affecting network behaviour. Suppliers of networks and communications equipment use this standard to derive a specification for their products in conjunction with the expectations of the communication systems and applications. As the KiloStream performance parameters table below shows, KiloStream digital private circuits are extremely reliable - offering 99.5% error-free seconds per annum. This level of performance exceeds the CCITT* G821 standard. The BT target figures for error performance are expressed in a manner consistent with CCITT* recommendation G821. This recommendation defines performance at the 64kbit/s level only; There is no CCITT* measurement agreement for bit rates lower than 64kbit/s, but BT recommends a similar measurement standard with the error count threshold as follows: Error parameter A - an error free second is a second in which no errors occur. Error parameter B - the error count threshold for a data rate of 48kbit/s is three or less bit errors in a minute period. Page 5 of 5

For data rates of 19.2kbit/s, 9.6kbit/s, 4.8kbit/s and 2.4kbit/s, the error count threshold is 12, 6, 3 and 2 or less bit errors respectively in a 10 minute period. Error parameter C - the error count threshold for data rates of 48bit/s, 19.2kbit/s. 9.6kbit/s, 4.8kbit/s and 2.4kbit/s in 48, 20, 10.5 and 3 or less respectively in a one second period KiloStream performance parameters Performance parameters A B C % error free seconds % 1 minute periods with error ratio better than 10-6 Envisaged performance based 98.8 98.5 99.935 on CCITT* recommendation G821 BT target 99.5 99.5 99.95 % 1 second periods with error ratio better than 10-3 When assessed over a one year period, KiloStream circuit availability will, in most cases; be better than 99.85%. This is equivalent to 13 hours unavailability in one year. A circuit is deemed to be unavailable where there is no data throughput for a period greater than 10 seconds, or when the error ratio exceed 10-3 for more than 10 consecutive seconds. Intermittent breaks greater than 10 seconds in duration % break free days 80 % days with one break 12 % days with two or more breaks 8 Note: This performance relates to an averaging period of one year. Long term bit error ratio of 10-7 The long term bit error ratio target limit is 10-7 for KiloStream when evaluated over a minimum period of 24 hours, excluding one second periods with error ratios worse than 10-3 Consider this before ordering terminal equipment Where errors affect the circuit, it is possible that the interchange circuits - 'indicate' or 'carrier detect' - can be momentarily turned to the OFF position. If this happens, the terminal equipment can interpret this as a break in transmission. Your attention is also drawn to the interchange circuit details. Specifically for KiloStream, you should also check with your supplier for details of the data set ready (107) and the connect data set to line configuration (108/1) applicable to your terminal. Additional options for X.21 bis are: ready for sending delay 10-20ms or no delay, up to 48kbit/s; connect data set to line circuit; 108/1 enabled or not enabled up to 19.2kbit/s (V.24 only). Data set ready option: circuit 107 to follow circuit 108/1 or set off under fault condition. For KiloStream structured services, errors in transmission at all speeds through BT's network can cause errors in the received data bits, or errors in the two control bits governing envelope alignment and status. The effect of these errors must therefore be taken into account before ordering your terminal equipment Page 6 of 6