PREZONE1 Instruction manual

Similar documents
REVAMP4100 Instruction manual

REVAMP4120T Instruction manual

REVAMP2250 Instruction manual

MA30 - MA60 Instruction manual

MA120 - MA240 Instruction manual

HARMONY SINGER 2. Battery-Powered Vocal Effects Stompbox with Guitar-Controlled Harmony, Reverb and Tone. User Manual

ECA COMMERCIAL AMPLIFIER OWNER S MANUAL ECA-70MIXAMP V / 70V / 4Ω Amplifier ECA-70MIXAMP-1-60 OUTPUT LEVEL POWER MASTER MIC 1

WX-1 & WX-3 OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier. WX-1 and WX-3.indd :23:16

MIC MECHANIC 2. Ultra-Simple Battery-Powered Vocal Effects Stompbox with Echo, Reverb and Pitch Correction. User Manual

M-300 Mono power amplifier User s guide

A Channel Amplifier

PM7400MKII. Instruction manual

EPA152/252/502. User Manual.

A32. f u l l y b a l a n c e d p o w e r a m p l i f i e r. user guide

plifier D-501 otion Am Tactile M

User Guide. Wideband 4-channel Auto Gain-Control Antenna Divider

DA216S DISTRIBUTION AMPLIFIER

Lanen True Diversity UHF Systems For electric and bass guitars: GB21 For Series 21 mics: UHF21. User Manual GB21 receiver/uhf21 transmitter

EPA104/254. User Manual.

Model CC4041. CC Series Amplifier. Installation and Use Manual

A WORLD OF LISTENING WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE.

Important Safety Information

IMPORTANT SAFETY INSTRUCTIONS

CLASS D STEREO AMPLIFIER 60 WPC. Model: APA102 User Manual

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

arthur ART48 - YELLOW ACOUSTIC FIDELITY USER MANUAL Assembling instruction on ART48-L/Rmast manual

Lanen Series 21 from Prodipe SB21 Lanen Instrument Mic. User Manual SB21 Lanen Sax / Brass / Percussion

Mini-Z. Manual. Model: ZA-21.

Model CC4052. CC Series Amplifier. Installation and Use Manual

IMPORTANT SAFETY INSTRUCTIONS

i3speakers LX503 MK2 User Manual

Safety Precautions. Important Safety Instructions

REVAMP2600 Instruction manual

IMPORTANT SAFETY INSTRUCTIONS

2BSST POWER AMPLIFIER OWNER S MANUAL

SVS SoundPath Wireless Audio Adapter Owner s Manual

Dual Alarm Clock Radio with Digital Tuning NRC-174. Instruction Manual Please read carefully before use and keep for future reference.

a u d i o p h i l e d i g i t a l - t o - a n a l o g u e c o n v e r t e r user guide

Primare A33.2 Amplifier User Guide

KLASIK NEAR FIELD ACTIVE STUDIO MONITOR

REVAMP2250 Instruction manual

3400 Watt Stereo Power Amplifier

User Manual LMS-325 Line Monitor Speaker

MIXER POWER AMPLIFIER BG-130

XD-V30 Digital Wireless System

MAZ 18/MAZ 38. Manual. Model: ZA-8 / ZA-5.

Spider. Pilot s Handbook Manuel de pilotage Pilotenhandbuch Pilotenhandboek Manual del Piloto 取扱説明書

User Manual. imix 63 Stereo mixing preamplifier

Classic Series Public Address Amplifiers C10 & C20 Models

Classic Series Public Address Amplifiers C10 & C20 Models

Spider IV 15. Pilot s Handbook Manuel de pilotage Pilotenhandbuch Pilotenhandboek Manual del Piloto 取扱説明書

Carmen Ghia. Manual. Model: ZA-07.

Classic Series Amplifiers C35, C60, & C100 Models

HTA125A/250A. Power Amplifiers. Installation & Use Manual

FOR AVLEX ONLY MT-24A. User Guide. 2.4 GHz Digital Stationary Transmitter

INSTALLATION MANUAL ECA-70VMINI-60W ECA-70VMINI-60W L VOLUME SPEAKER OUTPUTS 12VDC IN + L+ L- GND R+ R- S GND GND Tx Rx

PRE16/26 AUDAC PROFESSIONAL AUDIO EQUIPMENT. PRE16/26 6 Channel Pre-Amplifier Single/Double Output Zone. User Manual & Installation Guide

User Manual. MA 21 Two zone mixing amplifier

w i t h T A B L E O F C O N T E N T S Safety Information 2 Certifications/Standards 3

1695T Black Magick. User Manual

MODEL A1. PackLite TM POWER AMPLIFIER

AV25-2 User Manual. 1 Important safety instructions

Antidote. Manual. Model: ZA-35.

Important safety instructions

a u d i o p h i l e p r e a m p l i f i e r user guide

User Manual. MA 240 Mixing amplifier

Z-LUX. Manual. Model: ZA-38.

Spider Valve. Pilot s Guide Manuel de pilotage Pilotenhandbuch Pilotenhandboek Manual del Piloto 取扱説明書

IMPORTANT SAFETY INSTRUCTIONS

Professional Tube Amplifier PRO-18 User Manual

DSR-3. Bedienungsanleitung User Guide

A-16D A-Net Distributor

10 WATT GUITAR COMBO

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

3.Avoid spilling liquids or allowing materials to enter the cabinet

Copyright 2017, Samson Technologies Corp. v1.1. Samson Technologies Corp. 278-B Duffy Ave Hicksville, NY

TMP40. User Manual.

Owners Manual Excite X14A

R850MC. 4-Zone, 8-Channel Power Amplifier Installation Manual

SPECIAL 6. 6-Watt Vacuum Tube Guitar Amplifier. User Manual

875HT OWNER S MANUAL

11. ONLY USE attachments/accessories specified by the manufacturer.

1668RT Jupiter. User Manual

DPA-1.2. Instruction Manual. 2 Channel Amplifier with Auto A/B Selector DPA-1.2 DPA-1.2 POWER SERIAL # LINE INPUT SENSING SPEAKER B OUT

OWNER S MANUAL CPS 1 / CPS 2 CONTRACTOR PRECISION SERIES

Operation Manual. Public Address Amplifier MA-106


STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

UA ª 35T II Utility Amplifier OPERATING INSTRUCTIONS

AV30MX-2 Operation Manual

JAM combo amplifier for acoustic instruments

KLD Guitar AMP MOJO12HR

Big Bang. B B O w n e r s M a n u a l. Power Amplifiers. SpeakerCraft BB2125 POWER ACTIVE PROTECTION L

ZM 84 Audio Mixer. User Manual. Order code: CRAM41. Audio Mixer ZM 84 AUX 3 AUX 1 AUX 2 AUX 4 MASTER 1 MASTER 2 OFF BASS BASS TREBLE TREBLE BASS BASS

Instruction Manual Please read carefully before use and keep for future reference.

User Manual BUGERA Classic 120-Watt Hi-Gain Dual Reverb Valve Amplifier Head. bugera-amps.com

PROLUDE AMPLIFICATION D750. User s manual for the tube preamplifier version

PAM 1270 MULTI-ZONE AMPLIFIER OWNER S MANUAL WARRANTY & REPAIR

Multi-Channel AVC Active Receiver Hubs Installation Sheet

a u d i o p h i l e i n t e g r a t e d a m p l i f i e r user guide

Transcription:

PREZONE1 Instruction manual

PREZONE1 manual PREZONE1 Instruction manual 3

4 Preamplifiers IMPORTANT SAFETY INSTRUCTIONS Read these instructions - All the safety and operating instructions should be read before this product is operated. Keep these instructions - The safety and operating instructions should be retained for future reference. Heed all warnings - All warnings on the appliance and in the operating instructions should be adhered to. Follow all instructions - All operating and use instructions should be followed. This professional device needs to be installed by qualified personnel only. Danger: Exposure to high sound levels may cause a permanent hearing loss. Individuals vary considerably to sound pressure level induced hearing loss but nearly everyone will lose some hearing if exposed to high sound pressure levels for a sufficient amount of time. Therefore it is recommended that all persons exposed to equipment capable of producing high sound pressure levels, such as this amplifier, be protected by hearing protection while installing or operating this unit. Make sure to only use power outlets conform to the power requirements listed on the back of the unit. Do not connect the inputs / outputs of amplifiers or consoles to any other voltage source, such as a battery, mains source, or power supply, regardless of whether the amplifier or console is turned on or off. Do not drive the inputs with a signal level higher than that required to drive equipment to full output. Do not run the output of any amplifier back into another input. This unit has NOT been designed for use in mobile applications, such as: mobile discobars, mobile PA systems, Live bands, audio rental systems, Using it in such application will lead to product damages and safety risks. Do not use this apparatus near water Clean only with dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not defeat the safety purpose of the polarised or grounding plug. A polarised plug has two blades with one wider than the other. A grounding plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. Always use the device with a grounded mains power plug. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. Protect the power cord from being walked on, pinched or damaged. Particularly at the plugs, connectors and at the point where they exit from the apparatus. Only use attachments/accessories specified by the manufacturer. Unplug the apparatus during lightning storms or when unused for long periods of time. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart or rack is used, use

PREZONE1 Instruction manual 5 caution when moving the cart/apparatus combination to avoid injury from tip-over. Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. The apparatus shall not be exposed to dripping or splashing and that objects filled with liquids, such as vases, shall not be placed on apparatus. WARNING: The mains plug/appliance coupler is used as disconnect device, the disconnect device shall remain readily operable. This lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of non-insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock. - Warning: To reduce the risk of electric shock, do not remove cover (or back) as there are no user-serviceable parts inside. Refer servicing to qualified personnel. - The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the appliance. Caution: To reduce the risk of electric shock. Protective earthing terminal. The apparatus should be connected to a mains socket outlet with a protective earthing connection. Correct Disposal of this product. This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. No naked flame sources, such as lighted candles, should be placed on the apparatus. Minimum 5 cm distances around the apparatus for sufficient ventilation. Do not install this equipment in a confined or building-in space such as a book case or similar unit, and remain a well ventilation conditions at open site. The ventilation should not be impeded by covering the ventilation openings with items such as newspaper, table-cloths, curtains etc. The use of apparatus in moderate climates.

6 Preamplifiers Introduction Providing the missing link There is a huge demand for preamplifiers with multiple zone applications in the fixed install audio market today. Although there are a lot of products available, none are able to satisfy both installers and users. The overall connectivity and use of existing products remain a battle to install and operate. Thanks to the input from our partners and the comprehensive research of our R&D department we succeeded in creating the ultimate pre-amplifier range the PREZONE Series. Apart Audio together with a world leading design company completely redesigned the preamplifier as we know it today. The result is the revolutionary Apart PREZONE1 a multi-functional stereo preamplifier that allows you to independently control the volume in 2 stereo zones. It gives you the possibility to mix the 2 microphone levels easily with a music sources. The innovative design of the front will instantly indicate how to operate the progressive PREZONE1. The logical rear panel will give every installer an instant understanding on how to install the unit. It s easy to distinguish the PREZONE1 from its competitors. Its higher signal to noise ratio, ease-of-use, logical design and versatile features makes it suitable for almost every professional audio application.

PREZONE1 Instruction manual 7 Features 19 rack unit, 2U high with removable rack ears Patented front panel designed to create an intuitive user interface. Front control for end-user and back panel for configuration installer (out of reach of end-user) Universal switching mode power supply No cooling fan - maintenance free 3 priority levels for audio routing Dedicated isolated emergency input with vox and mute all switch 2 mic / line inputs with tone controls and phantom power (48V) 4 stereo line inputs on RCA connectors 2 zone outputs with tone balance controls Balanced and unbalanced outputs for each zone Mono / stereo switch for each zone output Signal clip indicators and gain control on all inputs for fast and easy configuration of the input gain Front button standby with low power consumption

8 Preamplifiers Connections 1 3 5 7 9 2 4 6 8 1. Emergency input: connect your balanced 0 dbv line level emergency input audio signal to the euroblock connector. If available, connect the emergency contact to the mute all connection. The contact must be potential free, i.e. a relay or switch contact that does not carry any voltage. Alternatively, activate the vox circuitry by turning the vox control until you hear an audible click. Now turn the vox control up while playing music until the vox circuit is activated. The vox and the mute all switch have the same function: they will mute all other sources, and will wake up the unit from standby (auto standby and front button standby). The emergency level can be set with the volume control. If the clip led lights up when the emergency signal is present, lower the level of the emergency signal at the source to avoid distortion.

PREZONE1 Instruction manual 9 2. MIC A input: connect a microphone here: the euroblock accepts balanced microphone or line level signals and RCA accepts line level signals. Set the mic / line switch accordingly. The stereo unbalanced input signals are mono summed and merged with the balanced input into one signal, which is send to all zone outputs. Phantom power (48 V) can be applied to the balanced euroblock by pushing the phantom power switch. The led beneath the switch will be lit when phantom power is present. Adjust the gain control so that the clip led does not light up when the signal is at its highest level. If necessary, activate the vox circuitry by turning the vox level control until you hear an audible click. Now turn the vox level control up until the vox circuit is activated. The MIC A volume can be set using the front panel level control (2). MIC A can be activated by pressing the MIC A select switch on the front panel (3). The vox circuit, when activated, will attenuate all lower priority sources (MIC B, input 1-4) by 30 db. MIC A has its own lo and hi tone controls. MIC A input is compatible with the Apart ALINP local input panel that requires phantom voltage. Note:When you only use the RCA inputs, keep the mic/line select switch set to LINE to improve the output noise. 3. MIC B input: connect a microphone here: the euroblock accepts balanced microphone or line level signals and RCA accepts line level signals. Set the mic/line switch accordingly. The stereo unbalanced input signals are mono summed and merged with the balanced input into one signal, which is send to all zone outputs. Phantom power (48 V) can be applied to the balanced euroblock by pushing the phantom power switch. The led beneath the switch will be lit when phantom power is present. Adjust the gain control so that the clip led does not

10 Preamplifiers light up when the signal is at its highest level. MIC B has its own lo and hi tone controls. MIC B input is compatible with the Apart ALINP local input panel that requires phantom voltage. Note:When you only use the RCA inputs, keep the mic/line select switch set to LINE to improve the output noise. 4. Input 1-4: line level input on RCA connectors. Adjust the gain control so that the clip led does not light up when the signal is at its highest level. 5. Zone 1 EQ: lo and hi tone controls for the selected line input 1-4 being fed to zone 1 output. 6. Zone 1 out: a. Mono/stereo switch: With this switch the output can be configured as a mono output or stereo output. b. Balanced / RCA outputs: Balanced and RCA output supply a line level output signal. 7. Zone 2 EQ: lo and hi tone controls for the selected line input 1-4 being fed to zone 2 output. 8. Zone 2 out: a. Mono/stereo switch: with this switch the output can be configured as a mono output or stereo output. b. Balanced / RCA outputs: balanced and RCA output supply a line level output signal. 9. Main power input, switch and fuse: connect the mains power cord here. Switch on the power switch to power up the unit. The mains fuse is also located here.

PREZONE1 Instruction manual 11 Operation 1 3 5 8 2 4 6 7 1. On/Standby button and led: switch the standby ON/OFF with this button. Please note that the main power switch at the rear of the unit must be switched on. Read more about the standby below. When the unit is on, the on/standby button led will light up steadily. When the unit is in standby, the led will fade in/ fade out. 2. MIC A/B volume control: this control determines the output volume of MIC A/B for both zones. 3. MIC A/B on/off switch: use this button to turn MIC A/B on and off for both zones. 4. Name field: here you can attach the name stickers and the name fields supplied with the unit. 5. Input 1 4 selection buttons: by pressing these buttons, you can toggle between inputs 1 to 4, or switch off the selected input by pressing the button that is lit. You can only select one input at a time for both zones. 6. Zone 1 on/off button and volume control: By pressing the on/off button, the zone can be enabled (green) or disabled (red). While the zone is muted, the selected inputs will be muted in these zones.

12 Preamplifiers Standby When the emergency is activated, the output will be automatically unmuted for the duration emergency is active. Turn the volume control clockwise to increase the volume of zone 1, counter clockwise to decrease. The volume control sets the output volume of the selected input 1-4 for zone 1 only. 7. Zone 2 on/off button and volume control: By pressing the on/off button, the zone can be enabled (green) or disabled (red). While the zone is muted, the selected inputs will be muted in these zones. When the emergency is activated, the output will be automatically unmuted for the duration emergency is active. Turn the volume control clockwise to increase the volume of zone 2, counter clockwise to decrease. The volume control sets the output volume of the selected input 1-4 for zone 2 only. 8. Status leds: S/C or signal/clip leds lights up green when an output signal is present and turns red when the amplifier is clipping in the zone output. Emergency led will light up to indicate that an emergency message is coming through (mute all contact or vox). Vox MIC will light up to indicate that the vox circuit of MIC A is active. The vox circuit will not be active when MIC A isn t lit. The On / Standby knob led will slowly fade in/out to indicate that standby is activated. The unit will wake up from standby when: Pressing the standby/power button Activating the emergency input by making a connection to the emergency mute all input or vox circuit Cycling the power using the rear power switch (or a mains power interruption) Pushing any front button

PREZONE1 Instruction manual 13 Technical specifications Product name PREZONE1 Emergency Nominal input sensitivity SNR (Volume max) (nominal output (0dBV), a-weighted, 20Hz-20kHz) 0 dbv (1 Vrms) 102 db THD+N @ nominal output -6 db < 0.7% Frequency response (-3dB) Input impedance 300 Hz 20 khz 5 kohms MIC A / MIC B Nominal input sensitivity balanced input Mic selected (front volume max) SNR @ balanced input, mic selected (Gain max)(nominal output (0dBV), a-weighted, 20Hz-20kHz) Nominal input sensitivity balanced input Line selected (front volume max) SNR @ balanced input, line selected (Gain max)(nominal output (0dBV), a-weighted, 20Hz-20kHz) Nominal input sensitivity RCA input 1 Input only (front volume max) Nominal input sensitivity RCA input Both inputs used (front volume max) SNR @ RCA input (gain max) (nominal output (0dBV), a-weighted, 20Hz-20kHz) Frequency response (-3 db) -47dBV to -19 dbv 81 db -17 dbv to +11 dbv 89 db -17 dbv to +11 dbv -22 dbv to +6 dbv 89 db Balanced mic: 190 Hz 20 khz RCA/Balanced Line: 20 Hz 20 khz THD+N @ nominal output -6 db <0.2 % LO EQ HI EQ +-9 db @ 100 Hz +- 8.5 db @ 10 khz

14 Preamplifiers Phantom Vox attenuation MIC B, input 1-4 Input impedance Balanced Input impedance RCA Voltage: 48V 30 db 2K 10K Input 1-4 Nominal input sensitivity RCA (0 dbv output) SNR @ RCA input (Gain max) (nominal output (0dBV), a-weighted, 20Hz-20kHz) Crosstalk, L vs R (1kHz, nominal output (0dBV), 20Hz-20kHz) -17 dbv to +11 dbv 97 db -80 db THD+N @ nominal output -6 db <0.2% Frequency response (-3 db) LO EQ HI EQ Input impedance 20 Hz 20 khz +-9 db @ 100 Hz +-8.5 db @ 10 khz 10K Power supply Max power consumption Idle power consumption Standby power consumption Power supply 30 W 10 W <1.8 W 100-240 VAC / 50-60 Hz / 30 W General Dimensions amplifier (l x d x h) Weight accessories 430 x 290 x 89 mm 3.65 kg Rack ears, power cable, euroblock connectors, sticker paper, feet, safety document The warranty of this product and the applicable terms and conditions are provided by the dealer where you purchased this product.

developed by Apart Audio nv Industriepark Brechtsebaan 8 bus 1 2900 Schoten - Belgium Company names, product names and trademarks are property of their respective owners. Apart-Audio specifications are subject to change without notice.