MVP MICRO VASCULAR PLUG SYSTEM AN OPTION FOR PERIPHERAL EMBOLIZATION CASE REPORTS

Similar documents
Confidence Delivered.

MEDTRONIC CARELINK PROGRAMMER

R Evolut. Conf idence. Delivered. CoreValve

Paceart Optima System

Endovascular aortic repair Fenestrated

MEDICARE S OUTPATIENT PROSPECTIVE PAYMENT SYSTEM

CODMAN NEURO ORBIT GALAXY DETACHABLE COIL SYSTEM

Physician s. Zenith. pocket reference guide ENDOVASCULAR GRAFTS. Indications for use. Component ordering information. Introduction system information

The pattern scanning multi-color photocoagulator that puts you in control

A 360-Degree Approach to Neuroendovascuar Therapy

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

CROSS YOUR WAY SUPPORT CATHETERS GUIDEWIRES CROSSING CATHETERS RE-ENTRY DEVICES

Upgrade from Medtronic Pump. Existing Bridging the Gap Patient. Upgrade from other Brand (please specify)

Microwave Antennas for Medical Applications

Successful endovascular treatment for BTK lesion using wire rendezvous technique and retrograde knuckle wire technique by collateral approach

General Anesthesia Airway

Product Introduction. MF2400C Series. Microwave Frequency Counter

Product Introduction. MF2400C Series. Microwave Frequency Counter

Improvement of CT image quality with iterative reconstruction idose4

Perclose ProGlide. Deployment Steps. Suture-Mediated Closure System Abbott. All rights reserved. ANZ /11

Better diagnosis and treatment all-in-one.

The feasibility of breath-hold high-resolution 3D-MRCP obtained with 32 channel torso cardiac coil and T2-prepBTFE

Radiofrequency Ablation Needle Electrodes. Procedural Algorithms and Lesion Geometry

Fuji Intelligent Chromo Endoscopy

ASAHI Peripheral Guide Wire

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500 US EDITION

Lifeline for a Lifetime: Planning for Your Vascular Access

Beyond Performance and Value

AN566. Using the PORTB Interrupt on Change as an External Interrupt USING A PORTB INPUT FOR AN EXTERNAL INTERRUPT INTRODUCTION

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

Medtronic Company Overview

Through-beam ring sensors

Precision Vascular Robotics. Corindus Vascular Robotics (CVRS) January 2017

Precision Spectra OMG

Frame through-beam sensors

WallPilot TM User Guide

Diagnosing the Success Formula for MedTech Companies in India

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

160-slice CT SCANNER / New Standard for the Future

Welcome to a radically different approach to cancer treatment.

White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe

An Uneasy Marriage: Health Care Technology and its Relationship to Quality

User Conference Title

Comparison of high-resolution C-arm cone-beam CT imaging and conventional 3D rotational angiography for the better microvascular visualization

Minimally Invasive Therapies Group

BU941ZP BU941ZPFI HIGH VOLTAGE IGNITION COIL DRIVER NPN POWER DARLINGTON TRANSISTORS. Figure 1: Package

San Diego. March 2, American College of Surgeons Surgical Health Care Quality Forum. American College of Surgeons

Dornier Genesis. Urology Imaging System with FPD

introducing the M22 success made simple

Introducing the LumiCoil Platinum Fiducial Marker. Features of LumiCoil Platinum Fiducial Markers. Expanding Innovation in EUS

Disclosure of movement of 1% or more in substantial holding or change in nature of relevant interest, or both

Disclosure of movement of 1% or more in substantial holding or change in nature of relevant interest, or both

SONOACE 6000C MT DIGITAL COLOR. Affordable PC-based Digital CFM Ultrasound System. Specifications.

Multi-Access Biplane Lab

3GPP LTE FDD Performance Requirement

UPDATE TO MEDICAL DEVICE CORRECTION

STAHL ENDOSCOPY UROLOGY

Characterizing RF Losses between GSM Phones and Test Equipment

Breakthroughs in Medical Imaging For Better Health AM 570 KVI January 28, 2007 Norm Beauchamp, M.D. Cecily Clemons. Introduction

Comparison of MS2830A/MS2840A and NF Analyzer for Noise Figure Measurements

Network ScanGear. User s Guide ENG

How to Penetrate the Proximal and Distal Fibrous Caps in Chronic Total Occlusion?

EVIS EUS ENDOSCOPIC ULTRASOUND CENTER EU-ME2 Dedicated ultrasound processor with versatile functionality.

Initial Insulin Pump Funding Request

Wire Technology: How to Choose Based on Anatomy and Strategy

(12) Patent Application Publication (10) Pub. No.: US 2004/ A1

ST2111FX HIGH VOLTAGE FAST-SWITCHING NPN POWER TRANSISTOR. Features. Applications. Internal Schematic Diagram. Description.

M 5. M5 Hand-carried Diagnostic Ultrasound System. Mindray. A practical, durable ultrasound tool for high-quality imaging where and when you need it.

TYPE 2 DIABETES PUMP CONSUMABLES GRANT PROGRAM

DOPPLEX VASCULAR DOPPLERS. ...with people in mind

The Versatile and Powerful ACLxy. ACLxy

VA L U E A N A LY S I S B R I E F

New Amersham Hyperfilm

TDA W MONO CLASS-D AMPLIFIER 18W OUTPUT POWER:

SL3101. Passive Iridium Antenna Product Specifi cation

Comparison of MS2830A and NF Analyzer for Noise Figure Measurement

Ziehm Vision R Powerful solution for superior mobile imaging.

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

User Manual for 24 GHz Blind-Spot Radar Sensor

Using Web-Based Computer Graphics to Teach Surgery

SL3101. Passive Iridium Antenna Product Specification

This information will help you g et ready for your portal vein embolization at Memorial Sloan Kettering (MSK).

MD1802FX. High voltage NPN power transistor for standard definition CRT display. Features. Applications. Description

Yellow Scan Laser Photocoagulator YLC-500 Vixi. Yellow Laser Photocoagulator YLC-500

Ziehm Vision R Powerful solution for superior mobile imaging.

MD2310FX. High voltage NPN power transistor for standard definition CRT display. Features. Application. Description

UCSF TRACS TM. ChemoFilter. By Dan Fost and Yan Cao, Ph.D. March 14, 2018

High voltage NPN Power transistor for standard definition CRT display. R BE =60Ω typ. Order code Marking Package Packing

Accepts Wire Guide Diameter inch. Stent Diameter mm

TDA0161. Proximity Detectors. Features. Description. Block Diagram. 10mA Output Current Oscillator Frequency 10MHz Supply Voltage +4 to +35V

KODAK PLUS-X Reversal Film 7265

STB High voltage fast-switching NPN power transistor. Features. Applications. Description

Usage E-UTRA Band. MA2700 InterferenceHunter with Bandpass Filter and Yagi Antenna

Product Introduction DVB-T/H. MS8911B Digital Broadcast Field Analyzer

Vivid S5. Cardiovascular ultrasound system. GE Healthcare. Davis Medical

MD2009DFX. High voltage NPN power transistor for CRT TV. Features. Application. Description

Disclosure: Within the past 12 months, I have had no financial relationships with proprietary entities that produce health care goods and services.

Making a healthier world

TDA W MONO CLASS-D AMPLIFIER 1 FEATURES 2 DESCRIPTION. Figure 1. Package 25W OUTPUT POWER:

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

Transcription:

MVP MICRO VASCULAR PLUG SYSTEM AN OPTION FOR PERIPHERAL EMBOLIZATION REPORTS

TYPE II ENDOLEAK FROM THE INFERIOR MESENTERIC ARTERY Nuno V Dias MD, PhD Associate Professor Vascular Center Skåne University Hospital Malmö Malmö SWEDEN HEPATIC ARTERY AND PORTAL VEIN FISTULA PRESENTATION Patient is a 72 year old male with an abdominal aortic aneurysm that had previously been treated with an infrarenal EVAR and thereafter subsequent proximal extension with a fenestrated cuff. Due to continuous expansion of the AAA and the presence of a type II endoleak from the IMA inferior mesenteric artery, it was decided to conduct an embolization of the IMA. A 5 mm MVP microvascular plug system was placed under local anesthesia in the main trunk of the IMA. Access was gained from the SMA fenestration through Riolans Arcade. A Progreat Omega * micro catheter from Terumo was used. The IMA was immediately embolized post procedure and remained embolized at follow up. Celiac trunk angiogram showed hepatic artery to portal vein fistula. Selective right hepatic artery catheterisation showed the early opacification of the portal vein. 5 mm MVP micro MVP plug in the target vessel showed complete occlusion of the fistula.

CIRCUMFLEX ARTERY BLEED DUE TO TRAUMA PRE-CHEMO EMBOLIZATION OF PHRENIC ARTERY TUMOR Patient has active bleeding due to trauma. The angiogram shows the circumflex iliac artery and the extravasation and the site for embolization. 3 mm MVP micro vascular plug system. The MVP plug was deployed in the circumflex lliac artery and stopped the bleeding. Patient presented with hepatocellular carcinoma. The angiogram showed a tumor in the phrenic artery. It was decided to embolize the artery shown by the curved arrow before performing chemotherapy to avoid chemo-agents in non target vessels. 5 mm MVP micro vascular plug. The patient showed good uptake after placement of MVP plug. The tumor was treated with chemo embolization. the same results. and instructions for use can be found on the product labeling supplied with each device.

WITH SPLENIC ARTERY TRAUMA PRE SIRT MAPPING SIRT: Selective Internal Radiation Therapy AFTER FIRST MVP PLUG DEPLOYMENT FINAL ANGIOGRAM Patient with splenic trauma and extravasation of contrast media. Patient was treated with two MVP micro After the first MVP plug, a control angiogram showed more vascular lesions. Therefore another MVP plug was placed. 3 mm and 5 mm MVP micro The post-procedure angiogram showed occlusion in the vessel. The patient did very well clinically. A follow up CT scan of the patient showed positive results. Patient is a 40 year old female with breast cancer metastatic to the liver. She presents for mapping in preparation for SIRT radioembolization. Gastroduodenal artery (GDA) was embolized to protect the upper GI tract from non-target embolization with SIRT microspheres. 5 mm MVP micro The GDA artery was immediately embolized. the same results. and instructions for use can be found on the product labeling supplied with each device.

GDA EMBOLIZATION FOR A BLEED Vladimir Sheynzon, MD Associate Professor of Radiology New York Presbyterian Hospital and Columbia Univeristy College of Surgeons and Physicians 630 West 168th Street New York, NY 10032 TREATMENT OF PAVM USING MVP PLUG Vladimir Sheynzon, MD Associate Professor of Radiology New York Presbyterian Hospital and Columbia Univeristy College of Surgeons and Physicians 630 West 168th Street New York, NY 10032 GDA: GastroDuodenal Arthery PAVM: Pulmonary ArterioVenous Malformation Patient is a 78 year old female with AML in blast crisis, who was admitted for persistent bleeding and melena via NG tube, and found to have duodenal ulcer on endoscopy. She has had 11 transfusions, unsuccessful in raising hemoglobin. It was decided to embolize the gastroduodenal artery. 3 mm and 5 mm MVP micro The GDA artery was immediately embolized. Patient is a 65 year old female with a history of epistaxis and recently diagnosed brain abscess. It was decided to embolize this pavm. 5 mm MVP micro A branch of pulmonary artery was embolized with the 5 mm MVP plug. The post procedure angiogram showed a complete occlusion of the pavm.

MVP PLUG MINIMIZES CT ARTEFACTS MICRO CATHETER DELIVERABLE MVP plug 1 Coils 1 GAME CHANGING TECHNOLOGY 1 Images are property of Medtronic

MVP TM Micro Vascular Plug System Product code Recommended vessel size MVP TM device outer diameter unconstrained MVP TM device length unconstrained Delivery wire length Min recommended micro catheter ID for 3Q / 5Q - and OD for 7Q/9Q Max recommended length of micro catheter / delivery catheter A B ID MVP -3Q MVP-3Q 1.5 3.0 mm 5.3 mm 12 mm 180 cm 0.021 153 cm MVP -5Q MVP-5Q 3.0 5.0 mm 6.5 mm 12 mm 180 cm 0.027 153 cm MVP -7Q MVP-7Q 5.0-7.0 mm 9.2 mm 16 mm 165 cm 4Fr 120 cm MVP -9Q MVP-9Q 7.0-9.0 mm 13 mm 18 mm 165 cm 5Fr 120 cm Invatec S.p.A. Via Martiri della Libertà 7 25030 Roncadelle (BS) Italy Tel: +39.030.2589311 Medtronic International Ltd. 49 Changi South Avenue 2 Singapore 486056 Tel: +65.6436.5000 medtronic.com/apv Medtronic 710 Medtronic Parkway NE Minneapolis, MN 55432 USA Tel: +1.763.514.4000 Medtronic Australasia Pty Ltd. 5 Alma Road North Ryde, NSW 2113 Australia Tel: +61.1800.668.670 Medtronic International Trading Sàrl Route du Molliau 31 CH-1131 Tolochenaz Switzerland Tel: +41.21.802.7000 Medtronic New Zealand Unit N16, Mezzanine Level 5 Gloucester Park Road Onehunga Auckland New Zealand Medtronic of Canada Ltd. 99 Hereford Street Brampton, Ontario L6Y 0R3 Canada Tel: +1.905.460.3800 Medtronic Korea Co., Ltd. 5F, Sajo Building 1001 Daechi-dong, Kangnam-ku Seoul, 135-280 Korea Tel: +82.2.3404.3600 Medtronic Latin America 3750 NW 87th Avenue, Suite 700 Miami, FL 33178 USA Tel: +1.786.709.4200 Medtronic META FZ-LLC Office Park, Block D, 2nd Floor PO Box 500638 Dubai Internet City Dubai, United Arab Emirates Tel: +971.4.818.2666 UC201712344EE 2017 Medtronic. All rights reserved. Medtronic, Medtronic logo and Further, Together are trademarks of Medtronic. * third party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company. Not for distribution in the USA, Japan or France. 5/17