User Manual 4 wire Earth Resistance Tester Model GRT300

Similar documents
User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

EARTH RESISTANCE TESTER

Pen-type DIGITAL MULTITESTER

8PK-ST1520 Digital Earth Resistance Tester

R/C SMD Tweezers Multimeter Model RC200

ET-3888 True RMS Clamp Meter. User Manual

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

400Amp True RMS AC Clamp Meter + NCV

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

200Amp AC Clamp Meter + NCV Model MA250

400Amp True RMS AC/DC Clamp Meter Model EX613

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

User s Guide. Digital AC/DC Clamp Meter Model 38394

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User Guide. AC/DC Mini Clamp Meter. Model

User Guide. Digital AC/DC Clamp Meter Model 38394

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Autoranging Multimeter Extech EX503

User s Guide. Model MA A AC Mini Clamp-on Meter

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

# Digital Multimeter

USER'S MANUAL DMR-6700

Compact MultiMeters + Voltage Detector

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

Pen Multimeter. Model

User s Guide. 400A AC/DC Clamp Meter. Model MA220

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

IDM 98-III & IDM 99-III Digital Multimeters

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

CONTENTS MS2033A. 1.Introduction Safety Information...01

AMM-1022 Digital Multimeter USER`S MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

Digital Clamp Meter Model: &

USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Digital Multimeter, Pen Type

Micro-Ohmmeter Model UM200

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

ATK Clamp Meter

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

KMD-S04 Multímetro de bolsillo

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

User's Manual. Clamp-on Power Datalogger. Model

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

OPERATOR S INSTRUCTION MANUAL

INSTRUCTION MANUAL E1612 EARTH TESTER 1. INTRODUCTION

MS2030 CAT III 600 V A V AUTO RS232

IDM 503 & 505 Digital Multimeters

TYPE - K.J.E.T. PRINTING THERMOMETER. Model INSTRUCTION MANUAL

USER'S MANUAL DMR-2400

UT207A/208A/209A Operating Manual. Table of Contents

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

AC/DC CLAMP METER USER S MANUAL

AC Clamp Meter + Phase Rotation Tester

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Table of Contents Title Page

User s Manual. Ground Resistance Clamp On Tester MODEL

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Model UT511 OPERATING MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No

Digital Multi Meter OPERATING INSTRUCTION. Table of Contents

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

USER'S MANUAL DMR-4350

OPERATOR S INSTRUCTION MANUAL

The Meter Structure The Figure 2-1 shows the Meter structure.

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

User Manual Digital Clamp Multimeter. model no.: MSR-C600

USER'S MANUAL DMR-4300

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

DM-46 Instruction Manual

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

True RMS Digital Multimeter Model:

AM

Printing Humidity/Temperature Meter

DMM8900 SERIES USERS MANUAL

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Mini Clamp Meter Model:

Instruction Manual ICM A9 Electrical Clamp Multimeter EN FR IT DE ES

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

True RMS AC / DC Power Clamp Meter Model

Model DIGITAL MULTIMETER

Model UT10A: OPERATING MANUAL Table of Contents (1)

PeakTech 1090/1095. Bedienungsanleitung / Operation manual / Mode d emploi / Istruzioni per l'uso / Manual de instrucciones

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

Transcription:

User Manual 4 wire Earth Resistance Tester Model GRT300 Additional User Manual Translations available at www.extech.com

Introduction Congratulations on your purchase of Extech s 4 Wire Earth Resistance Tester. The Model GRT300 has been designed and tested according to the IEC Publication 348, safety requirements for Electronic Measuring Apparatus, EN 61010-1, EN 61326-1, EN 61557-1, EN 61557-5 and other safety standards. Proper use and care of this meter will provide many years of reliable service. Safety Notes Read the all safety information carefully before attempting to operate or service the meter. Use the meter only as specified in this manual. Otherwise, the protection provided by the meter may be impaired. Rated environmental conditions. Indoor & outdoor use. Installation Category IV 300V. Pollution Degree 2. Altitude up to 2000m. Relative Humidity 80% max. Ambient temperature 0-40 C. Observe the International Electrical Symbols listed below: Detector is protected throughout by double insulation or reinforced insulation. Warning! Risk of electric shock. Caution! Refer to this manual before using the detector. Earth(ground) terminal. Equipment complies with current EU directives. WARNING To avoid electrical shock, do not touch the terminals during tests Never apply Voltage higher than 300V across P1 and P2 terminals. 2

Features Microprocessor controlled with advanced safety features Two line LCD display Auto-Ranging Earth resistance testing with four ranges: 0-2Ω/0-20Ω/0-200Ω/0-2kΩ Earth voltage measuring range of 0-300Vac Automatic C spike check. Automatic P spike check. 2-wire test 3-wire test 4-wire test Auto power off Data hold Safety standard: EN 61010-1 CATIV 300V, EN 61326-1 Meter Description 1. C1 terminal (Black test lead connection) 2. P1 terminal (Green test lead connection) 3. P2 terminal (Yellow test lead connection) 4. C2 terminal (Red test lead connection) 5 Display 6. Rc LED 7. Rp LED 8. 2 Wire button 9. 3 Wire button 10. 4 Wire button 11. ACV button 12. Power button 13. TEST/STOP button 3

Operation Battery Voltage check 1. Press the "ON/OFF" button, if "Battery Low" appears on the display, replace the batteries. Earth Voltage measurement 1. Connect the test leads as shown below. (1) Earth electrode (rod) under test (2) Test spike 2. Press the "ON/OFF" button and wait for Select Function to appear on the display. 3. Press the "ACV" button and then the "TEST/STOP" button. 4. The earth voltage will be displayed on the display. Note: When the earth voltage is more than 10V, errors in earth resistance measurements may occur. Make sure that the indicated value is less than 10V. 4

Earth Resistance measurement Note: The measured results may be influenced by inductive or capacitive coupling if the test leads are twisted or adjacent to each other. When connecting the Probes, keep the leads separated. Setup Insert the Potential spike and the Current spike (if required) as deep as possible into the soil. The distance between spikes must be 5 to 10 meters (16 to 32 feet). Four-terminal earth resistance measurements (1) Earth electrode (rod) under test (2) Potential spike (3) Current spike Three-terminal earth resistance measurements (1) Earth electrode (rod) under test (2) Potential spike (3) Current spike Two-terminal earth resistance measurements (1) Earth electrode (rod) under test (2) Potential spike 5

Testing 1. Connect the test leads for 2, 3 or 4 terminal testing. 2. Press the ON/OFF button and wait for the Select Function screen to appear. 3. Press the "2P", "3P" or "4P" button that agrees with the setup. 4. Press "TEST/STOP" button to begin the test. 5. The meter will beep while the test is in progress (approximately 10 seconds) and then the reading will appear on the lower line of the display. Notes: "Rc" & "Rp" LED indications: Rc: No test current output. Check connections. Rp: If Rp is on and the display indicates > 2 kω, the earth resistance is greater than 2000Ω. If, in "4P" mode, the display shows "Vp Error", short circuit C1(black) and P1(green). Measurement Considerations Two (2) terminal testing of earth resistance is appropriate for most general purpose testing in normally conductive soil. But, 2 terminal measurements include test lead and contact resistance in the measurement and the result will be a reading slightly higher than the true earth resistance. When measured results are higher than desired or if measurement directives require multi-terminal techniques, switch to the 3 or 4 terminal techniques as needed. 6

Maintenance 1. Rear cover 2. Battery 3. Fuse Fuse Replacement 1. Disconnect the test leads from the instrument. 2. Remove the rear cover by removing two screws. 3. Remove and replace the fuse with the new one of the same value and size 0.1A/250V, 5 x 20mm. 4. Replace and secure the rear cover. Battery replacement When "Battery Low" appears on the display, replace the batteries. 1. Disconnect the test leads from the instrument and remove the rear cover and the batteries. 2. The tester's battery is located under the tester. 3. Replace with eight 1.5V AA light batteries, taking care to observe correct polarity. 4. Reinstall battery holder and the battery cover. Cleaning and Storage WARNING: To avoid electrical shock or damage to the meter, do not get water inside the case. Periodically wipe the case with a damp cloth and detergent, do not use abrasives or solvents. 7

Specifications General Specifications Test Frequency 820Hz Test Current 2mA Temperature & Humidity Operating: 0 to 50 C (32 to 122 F) 80%R.H. Storage : -10 to 60 C (14 to 140 F) 80%R.H. Test Leads Red 15m, Black-10m, Yellow-10m, Green-5m Power Source 1.5V(AA) x 8 Dimensions 250(L) x 190(W) x 110(D)mm (9.84x7.5x4.33 ) Weight Approx. 1430g(battery included) Fuse 0.1A/250V 5 x 20mm Range Specifications Earth Ground Resistance Earth Voltage Range Resolution Accuracy 0 to 2 Ω 0.01 Ω ±(2%rdg+0.1Ω) 0 to 20 Ω 0.1 Ω ±(2%rdg+3dgt) 0 to 200 Ω 1 Ω ±(2%rdg+3dgt) 0 to 2 kω 0.01 kω ±(2%rdg+3dgt) 0 to 300 VAC (40 to 500Hz) 1VAC ±(2%rdg+3dgt) Copyright 2013-2017 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO-9001 Certified www.extech.com 8