EMC TEST REPORT. FCC 47 CFR Part 15B Industry Canada RSS-Gen Electromagnetic compatibility - Unintentional radiators Pleasanton USA

Similar documents
G0M TFC95IMR2-V01. Eurofins Product Service GmbH Reichenwalde Germany

EUROFINS PRODUCT SERVICE GMBH. Testing Cert # FCC RULES PART 15 / SUBPART B IC RSS-GEN ISSUE 3. DECT Basestation WHB003BS

EUROFINS PRODUCT SERVICE GMBH. FCC RULES PARTS IC RADIO STANDARDS RSS-210 Issue 7 FCC ID: UOU68981AA630D-01 IC: 1884E

EUROFINS PRODUCT SERVICE GMBH EN V Tracking solution. Bolero-LT2

EUROFINS PRODUCT SERVICE GMBH EN V1.6.1 EN V Asset tracker. Rock

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

D. Guarnone (verifier)

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

Dongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS

EMI T E S T R E P O R T

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

RF test report AU01+W02

FCC DoC TEST REPORT To: PARTICLE INDUSTRIES, INC To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: -

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

CENTRE OF TESTING SERVICE INTERNATIONAL

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

TEST REPORT Title 47-Telecommunication

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

STC Test Report. Date: Page 2 of 25 No.: MH The Hong Kong Standards and Testing Centre Ltd.

DELTA Test Report. Radio parameter test of Aperio radio in Server lock KS PA2. Performed for ASSA AB

EMI -- T E S T R E P O R T

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight

TEST REPORT. Table of Contents

Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators

STC Test Report. The Hong Kong Standards and Testing Centre Ltd.

DELTA Test Report. FCC Part 15 C test of Trackman III (TMA3A) Performed for Trackman A/S

TEST REPORT CONCERNING THE COMPLIANCE OF PART 15 JBP

EMC Test Report. Tested by: Jeremy O. Pickens, Senior EMC Engineer. Reviewed by: David Schramm, EMC/RF/SAR/HAC Manager

FCC 47 CFR PART 15 SUBPART B

Quality Auditing Institute # Schoolhouse Street, Coquitlam, BC, V3K 4X9, Canada. ISO Accreditation:

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

FCC Part 15 Subpart B

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

CENTRE OF TESTING SERVICE INTERNATIONAL

Test. Report. Manufacturer. Model No. FCC ID. Technology. and. 1. This. 3. This. pp John Newell. as UL. Date of Issue: 28 May 2013.

EUROFINS PRODUCT SERVICE GMBH FCC RULES PART 15 / SUBPART B IC RSS-GEN ISSUE 2. Test report no.: G0M E-18. Testing Cert #1983.

TEST REPORT FROM RFI GLOBAL SERVICES LTD

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

EMI T E S T R E P O R T

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

TEST REPORT. Table of Contents

TRANSMITTER MODEL: KAS-2030M

TEST REPORT. Report Number: MIN-001 Rev 1.1 Project Number: G Testing performed on the 2102 IPG

HID GLOBAL CORPORATION

TABLE OF CONTENTS. Report No.: SH E03 1. TEST RESULT CERTIFICATION...3

Test report No STO-002, Ed. 1 Page 2 (23) Revision History. Edition Date Description Changes First release. Version 1.

IC Test Report. SPORTON INTERNATIONAL INC. No. 52, Hwa Ya 1 st Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.

HID GLOBAL CORPORATION

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR

FINGERTEC WORLDWIDE SDN BHD FCC REPORT FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, PUCHONG, SELANGOR, MALAYSIA

FCC Report for Parts ,

FCC 47 CFR Part 15, Subpart B Verification ICES-003 Issue 4 February 2004 EN 55022: 2010 EN : A1: A2: 2009 EN : 2008

TEST REPORT. PolyComp 32X80P7.621YHB Electronic Sign. tested to the. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices

FCC 47 CFR Part 15, Subpart B Verification ICES-003 Issue 4 February 2004 EN 55022: 2010 EN : A1: A2: 2009 EN : 2008

FCC TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.

F2 Labs Peters Road Middlefield, Ohio United States of America

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

FCC REPORT. 2AKQO-Q740 FCC CFR Title 47 Part 15 Subpart C. * In the configuration tested, the EUT complied with the standards specified above.

Test. Report. : connectblue. Manufacturer. Model No. FCC ID 4.10, This. 3. This. as UL. Date of Issue: 22 May

Page 1 of 19 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

TEST REPORT N B Page 2

EMI -- T E S T R E P O R T

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR

f02 January 11, TÜV Rheinland Nederland B.V. P.O. Box AA Leek (NL) Eiberkamp VT Leek (NL)

IST EMC LAB. EMISSION TEST REPORT. : DSP-4284GM Basic Alternate. : PDP(Plasma Display Panel) : Daewoo Electronics Corp. : Daewoo Electronics Corp.

FCC C2PC Test Report

Test Report. Bluetooth Transceiver in UPCS Base Station

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

King Pigeon Communication Co., Limited

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

FCC Verification TEST REPORT

TEST REPORT. Table of Contents

T E S T - R E P O R T. Test Report No (Edition 1) for RF340-R. Inductive Tag Reader

ORT. MobiWire. Brand. Product. Dakota. Model. Report No. April 22, Issue. TA Technology

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

TEST REPORT. Report Number: MIN-005 Project Number: G Testing performed on the ICON Scanner OEM (Gen 1.1)

3. MEASURING DEVICES AND TEST EQUIPMENT For Radiated Emission Measurement... 6

MEASUREMENT REPORT FCC Part 15B

ACCORDING TO: FCC part 15 subpart C, and subpart B FOR:

Bluetooth Headset Jabra BTE6

TEST REPORT. Issued for:

FCC 15B Test Report. : BTv4.0 Dual Mode USB Dongle. Address : Thompson Ave. / Lenexa, Kansas / / USA

fcc01 February 18, TÜV Rheinland Nederland B.V. Eiberkamp VT Leek Telephone: Telefax:

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR FOB ASSY BIDIRECTIONAL R/C MODEL NUMBER: GHW-H001

FCC EVALUATION REPORT FOR CERTIFICATION

EMC TEST REPORT RADISYS CORPORATION. Tel: Fax:

FCC PART MEASUREMENT AND TEST REPORT

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply

Report No.: DREFCC CONTENTS. 1. General Remarks Test Laboratory General Information of EUT... 4

MARKING / FCC. Test Report n FCC Rev. 01

T A B L E O F C O N T E N T S DESCRIPTION PAGE

EMI -- T E S T R E P O R T

Transcription:

EMC TEST REPORT FCC 47 CFR Part 15B Industry Canada RSS-Gen Electromagnetic compatibility - Unintentional radiators Report Reference No.... : G0M-1202-1776-EF01-V01 Testing Laboratory... : Address... : Storkower Str. 38c 15526 Reichenwalde Germany Accreditation... : Applicant s name... : Polycom Inc. Address... : 4750 Willow Road Test specification: A2LA Accredited Testing Laboratory, Certificate No.: 1983.01 FCC Filed Test Laboratory, Reg.-No.: 96970 IC OATS Filing assigned code: 3470A 94588-2708 Pleasanton USA Standard... : 47 CFR Part 15 Subpart B RSS-Gen, Issue 3, 2010-12 ANSI C63.4:2009 Equipment under test (EUT): Product description Model No. Hardware version DECT6.0 PSTN Hands Free Conference Telephone SoundStation2W 2200-07800-160 Rev G L888 Firmware / Software version 1.85 FCC-ID: M72-SS2WD6 IC: 1849C-SS2WD6 Test result Passed Page 1 of 26

REPORT INDEX 1 EQUIPMENT (TEST ITEM) DESCRIPTION 4 1.1 Photos Equipment external 5 1.2 Photos Equipment internal 8 1.3 Photos Test setup 9 1.4 Supporting Equipment Used During Testing 11 1.5 Operating Modes 12 1.6 Test Equipment Used During Testing 13 2 RESULT SUMMARY 14 3 TEST CONDITIONS AND RESULTS 15 3.1 Test Conditions and Results Radiated emissions 15 3.2 Test Conditions and Results AC power line conducted emissions 22 Page 3 of 26

1 Equipment (Test item) Description Description Model Serial number Hardware version DECT6.0 PSTN Hands Free Conference Telephone SoundStation2W None 2200-07800-160 Rev G L888 Software / Firmware version 1.85 FCC ID IC Power supply AC/DC-Adaptor Manufacturer Highest emission frequency M72-SS2WD6 1849C-SS2WD6 120VAC Model : SPS-12-009-120 Manufacturer : TSEC Input : 100-240VAC / 50-60Hz Output : 12VDC /1.0A Polycom Inc. 4750 Willow Road 94588-2708 Pleasanton USA > 1000MHz (up to 5th Harm) Device classification Equipment type Class B Tabletop Number of tested samples 1 Page 4 of 26

1.1 Photos Equipment external EUT TOP FIXED PART EUT BOTTOM FIXED PART Page 5 of 26

EUT SIDE VIEW FRONT FIXED PART EUT SIDE VIEW BACK FIXED PART Page 6 of 26

DEDICATED AC/DC ADAPTER Page 7 of 26

1.2 Photos Equipment internal PCB TOP FIXED PART PCB BOTTOM FIXED PART Page 8 of 26

1.3 Photos Test setup RADIATED EMISSIONS Page 9 of 26

CONDUCTED EMISSIONS CONDUCTED EMISSIONS Page 10 of 26

1.4 Supporting Equipment Used During Testing Product Type* Device Manufacturer Model No. Comments AE TK-Anlage Auerswald ETS-2204 AE ISDN Telephone DeTeWe EuroMaster *Note: Use the following abbreviations: AE : Auxiliary/Associated Equipment, or SIM : Simulator (Not Subjected to Test) CABL : Connecting cables Page 11 of 26

1.5 Operating Modes Mode # 1 2 PP - charging DECT 6.0 Link to FP FP charging DECT 6.0 Link to PP Description Page 12 of 26

1.6 Test Equipment Used During Testing Radiated emissions Description Manufacturer Model Identifier Cal. Date Cal. Due Biconical Antenna R&S HK 116 Inv. No. 0012 Jan 10 Jan 13 LPD-Antenne R&S HL 223 Inv. No. 0295 Feb 11 Feb 13 LPD-Antenna R&S HL 025 Inv. No. 0512 Feb 10 Feb 13 EMI Test Receiver R&S ESU8 Inv. No. 0567 Dec 11 Dec 12 EMI Test Receiver R&S ESCS30 Inv. No. 0474 Jun 11 Jun 12 Conducted emissions Description Manufacturer Model Identifier Cal. Date Cal. Due AMN R&S ESH2-Z5 Inv. No. 0288 Sep 10 Sep 12 AMN R&S ESH3-Z5 Inv. No. 0040 Nov 10 Nov 12 EMI Test Receiver R&S ESCS 30 Inv. No. 0474 Jun 11 Jun 12 Page 13 of 26

2 Result Summary FCC 47 CFR Part 15B, Industry Canada RSS-Gen Product Specific Standard 47 CFR 15.109 RSS-Gen 4.9 & 4.10 47 CFR 15.107 RSS-Gen 7.2.4 Remarks: Requirement Test Reference Method Result Radiated emissions ANSI C 63.4 PASS AC power line conducted emissions ANSI C63.4 PASS Remarks Page 14 of 26

3 Test Conditions and Results 3.1 Test Conditions and Results Radiated emissions Radiated emissions acc. FCC 47 CFR 15.109 / IC RSS-Gen Verdict: PASS Laboratory Parameters: Required prior to the test During the test Ambient Temperature 15 to 35 C 22 C Relative Humidity 30 to 60% 35% Test according referenced standards Sample is tested with respect to the requirements of the equipment class Test frequency range determined from highest emission frequency Fully configured sample scanned over the following frequency range Reference Method ANSI C63.4 Equipment class Class B Highest emission frequency > 1000MHz (up to 5th Harm) Frequency range 30MHz to 5GHz Operating mode 1 Limits and results Class B Frequency [MHz] Quasi-Peak [dbµv/m] Result Average [dbµv/m] Result Peak [dbµv/m] Result 30 88 40 PASS - - - 88 216 43.5 PASS - - - 216 960 46 PASS - - - 960 1000 54 PASS - - - Comments: > 1000 - - 54 PASS 74 PASS Page 15 of 26

Electrical Field (dbµv/m) Spurious emissions under normal conditions according to FCC 15B Project number: G0M-1202-1776 Manufacturer: Polycom Inc. EUT Name: DECT6.0 PSTM Hands Free Conference Telephone Model: SoundStation2W Test Site: Operator: Mr. Handrik Test Conditions: Tnom: 22 C, Unom: 120 V AC (AC/DC adaptor) Antenna: Rohde & Schwarz HK 116, Vertical Measurement distance: 3m Mode: PP: charging; PP FP: active DECT (UPCS) link Test Date: 15.03.2012 Note: Index 4 60 FCC part 15B Class B QP RBW: 120 khz, Vertical Max Peak RBW: 120 khz, Vertical Max Quasi Peak 55 50 45 40 35 30 1 2 3 4 5 25 20 15 10 5 0 30 M 40 M 60 M 80 M 100 M 120 M 140 M 160 M 200 M Frequency (Hz) Frequency Quasi-Peak Quasi-Peak Limit Quasi-Peak Difference Quasi-Peak Status 72,612 MHz 34,88 dbµv/m 40 dbµv/m -5,12 db Pass 80,407 MHz 26,59 dbµv/m 40 dbµv/m -13,41 db Pass 81,859 MHz 25,95 dbµv/m 40 dbµv/m -14,05 db Pass 124,446 MHz 35,46 dbµv/m 43,5 dbµv/m -8,04 db Pass 134,82 MHz 33,85 dbµv/m 43,5 dbµv/m -9,65 db Pass Page 16 of 26

Electrical Field (dbµv/m) Spurious emissions under normal conditions according to FCC 15B Project number: G0M-1202-1776 Manufacturer: Polycom Inc. EUT Name: DECT6.0 PSTM Hands Free Conference Telephone Model: SoundStation2W Test Site: Operator: Mr. Handrik Test Conditions: Tnom: 22 C, Unom: 120 V AC (AC/DC adaptor) Antenna: Rohde & Schwarz HK 116, Horizontal Measurement distance: 3m Mode: PP: charging; PP FP: active DECT (UPCS) link Test Date: 15.03.2012 Note: Index 5 60 FCC part 15B Class B QP RBW: 120 khz, Horizontal Max Peak 55 50 45 40 35 30 25 20 15 10 5 0 30 M 40 M 60 M 80 M 100 M 120 M 140 M 160 M 200 M Frequency (Hz) Page 17 of 26

Electrical Field (dbµv/m) Spurious emissions under normal conditions according to FCC 15B Project number: G0M-1202-1776 Manufacturer: Polycom Inc. EUT Name: DECT6.0 PSTM Hands Free Conference Telephone Model: SoundStation2W Test Site: Operator: Mr. Handrik Test Conditions: Tnom: 22 C, Unom: 120 V AC (AC/DC adaptor) Antenna: Rohde & Schwarz HL 223, Vertical Measurement distance: 3m Mode: PP: charging; PP FP: active DECT (UPCS) link Test Date: 15.03.2012 Note: Index 7 60 FCC part 15B Class B QP RBW: 120 khz, Vertical Max Peak 55 50 45 40 35 30 25 20 15 10 5 0 200 M 300 M 400 M 500 M 600 M 700 M 800 M 1000 M Frequency (Hz) Page 18 of 26

Electrical Field (dbµv/m) Spurious emissions under normal conditions according to FCC 15B Project number: G0M-1202-1776 Manufacturer: Polycom Inc. EUT Name: DECT6.0 PSTM Hands Free Conference Telephone Model: SoundStation2W Test Site: Operator: Mr. Handrik Test Conditions: Tnom: 22 C, Unom: 120 V AC (AC/DC adaptor) Antenna: Rohde & Schwarz HL 223, Horizontal Measurement distance: 3m Mode: PP: charging; PP FP: active DECT (UPCS) link Test Date: 15.03.2012 Note: Index 6 60 FCC part 15B Class B QP RBW: 120 khz, Horizontal Max Peak RBW: 120 khz, Horizontal Max Quasi Peak 55 50 45 40 1 2 3 4 35 30 25 20 15 10 5 0 200 M 300 M 400 M 500 M 600 M 700 M 800 M 1000 M Frequency (Hz) Frequency Quasi-Peak Quasi-Peak Limit Quasi-Peak Difference Quasi-Peak Status 306,764 MHz 35,21 dbµv/m 46 dbµv/m -10,79 db Pass 331,796 MHz 38,87 dbµv/m 46 dbµv/m -7,13 db Pass 356,36 MHz 35,75 dbµv/m 46 dbµv/m -10,25 db Pass 380,942 MHz 36,04 dbµv/m 46 dbµv/m -9,96 db Pass Page 19 of 26

Electrical Field (dbµv/m) Spurious emissions under normal conditions according to FCC 15B Project number: G0M-1202-1776 Manufacturer: Polycom Inc. EUT Name: DECT6.0 PSTM Hands Free Conference Telephone Model: SoundStation2W Test Site: Operator: Mr. Handrik Test Conditions: Tnom: 22 C, Unom: 120 V AC (AC/DC adaptor) Antenna: Rohde & Schwarz HL 025, Vertical Measurement distance: 3m Mode: PP: charging; PP FP: active DECT (UPCS) link Test Date: 16.03.2012 Note: Index 8 60 FCC part 15B AV RBW: 1000 khz, Vertical Max Average 55 50 45 40 35 30 25 20 15 10 5 0 1000 M 1,5 G 2,0 G 2,5 G 3,0 G 3,5 G 4,0 G 5,0 G Frequency (Hz) Page 20 of 26

Electrical Field (dbµv/m) Spurious emissions under normal conditions according to FCC 15B Project number: G0M-1202-1776 Manufacturer: Polycom Inc. EUT Name: DECT6.0 PSTM Hands Free Conference Telephone Model: SoundStation2W Test Site: Operator: Mr. Handrik Test Conditions: Tnom: 22 C, Unom: 120 V AC (AC/DC adaptor) Antenna: Rohde & Schwarz HL 025, Horizontal Measurement distance: 3m Mode: PP: charging; PP FP: active DECT (UPCS) link Test Date: 16.03.2012 Note: Index 9 60 FCC part 15B AV RBW: 1000 khz, Horizontal Max Average 55 50 45 40 35 30 25 20 15 10 5 0 1000 M 1,5 G 2,0 G 2,5 G 3,0 G 3,5 G 4,0 G 5,0 G Frequency (Hz) Page 21 of 26

3.2 Test Conditions and Results AC power line conducted emissions Conducted emissions acc. FCC 47 CFR 15.107 / IC RSS-Gen Verdict: PASS Laboratory Parameters: Required prior to the test During the test Ambient Temperature 15 to 35 C 22 C Relative Humidity 30 to 60% 35% Test according referenced standards Fully configured sample scanned over the following frequency range Sample is tested with respect to the requirements of the equipment class Points of Application AC Mains Reference Method ANSI C63.4 Frequency range 0.15MHz to 30MHz Equipment class Class B Application Interface LISN Operating mode 1&2 Limits and results Class B Frequency [MHz] Quasi-Peak [dbµv] Result Average [dbµv] Result 0.15 to 5 66 to 56* PASS 56 to 46* PASS 0.5 to 5 56 PASS 46 PASS 5 to 30 60 PASS 50 PASS Comments: * Limit decreases linearly with the logarithm of the frequency. Page 22 of 26

Voltage (dbµv) EMI voltage test in the ac-mains according to FCC 15B Project number: G0M-1202-1776 Manufacturer: Polycom Inc. EUT Name: DECT6.0 PSTM Hands Free Conference Telephone Model: SoundStation2W Test Site: Operator: Mr. Handrik Test Conditions: Tnom: 22 C, Unom: 120 V AC (AC/DC adaptor) LISN: ESH2-Z5 N Mode: FP: active DECT (UPCS) link Test Date: 16.03.2012 Note: Index 10 80 FCC 15B AV FCC 15B QP RBW: 9 khz, Neutral Max Average RBW: 9 khz, Neutral Max Peak 70 60 50 40 30 20 10 0-10 150 k 300 k 600 k 1000 k 2 M 3 M 5 M 10 M 20 M 30 M Frequency (Hz) Page 23 of 26

Voltage (dbµv) EMI voltage test in the ac-mains according to FCC 15B Project number: G0M-1202-1776 Manufacturer: Polycom Inc. EUT Name: DECT6.0 PSTM Hands Free Conference Telephone Model: SoundStation2W Test Site: Operator: Mr. Handrik Test Conditions: Tnom: 22 C, Unom: 120 V AC (AC/DC adaptor) LISN: ESH2-Z5 L Mode: FP: active DECT (UPCS) link Test Date: 16.03.2012 Note: Index 11 80 FCC 15B AV FCC 15B QP RBW: 9 khz, Line 1 Max Average RBW: 9 khz, Line 1 Max Peak 70 60 50 40 30 20 10 0-10 150 k 300 k 600 k 1000 k 2 M 3 M 5 M 10 M 20 M 30 M Frequency (Hz) Page 24 of 26

Voltage (dbµv) EMI voltage test in the ac-mains according to FCC 15B Project number: G0M-1202-1776 Manufacturer: Polycom Inc. EUT Name: DECT6.0 PSTM Hands Free Conference Telephone Model: SoundStation2W Test Site: Operator: Mr. Handrik Test Conditions: Tnom: 22 C, Unom: 120 V AC (AC/DC adaptor) LISN: ESH2-Z5 N Mode: PP: charging; active DECT (UPCS) link Test Date: 14.03.2012 Note: Index 1 80 FCC 15B AV FCC 15B QP RBW: 9 khz, Neutral Max Average RBW: 9 khz, Neutral Max Peak RBW: 9 khz, Neutral Max Quasi Peak 70 60 50 1 2 3 4 5 40 30 20 10 0-10 150 k 300 k 600 k 1000 k 2 M 3 M 5 M 10 M 20 M 30 M Frequency (Hz) Frequency Quasi-Peak Quasi-Peak Limit Quasi-Peak Difference Quasi-Peak Status 175.2 khz 46.48 dbµv 64.71 dbµv -18.23 db Pass 217.5 khz 43.28 dbµv 62.91 dbµv -19.64 db Pass 266.1 khz 45.09 dbµv 61.24 dbµv -16.15 db Pass 2.044 MHz 41.8 dbµv 56 dbµv -14.2 db Pass 2.172 MHz 38.35 dbµv 56 dbµv -17.65 db Pass Frequency Average Average Limit Average Difference Average Status 175.2 khz 28.42 dbµv 54.71 dbµv -26.29 db Pass 217.5 khz 27.76 dbµv 52.91 dbµv -25.16 db Pass 266.1 khz 32.18 dbµv 51.24 dbµv -19.06 db Pass 2.044 MHz 35.95 dbµv 46 dbµv -10.05 db Pass 2.172 MHz 31.95 dbµv 46 dbµv -14.05 db Pass Page 25 of 26

Voltage (dbµv) EMI voltage test in the ac-mains according to FCC 15B Project number: G0M-1202-1776 Manufacturer: Polycom Inc. EUT Name: DECT6.0 PSTM Hands Free Conference Telephone Model: SoundStation2W Test Site: Operator: Mr. Handrik Test Conditions: Tnom: 22 C, Unom: 120 V AC (AC/DC adaptor) LISN: ESH2-Z5 L Mode: PP: charging; active DECT (UPCS) link Test Date: 14.03.2012 Note: Index 2 80 FCC 15B AV FCC 15B QP RBW: 9 khz, Line 1 Max Average RBW: 9 khz, Line 1 Max Peak RBW: 9 khz, Line 1 Max Quasi Peak 70 60 1 50 2 3 4 5 40 30 20 10 0-10 150 k 300 k 600 k 1000 k 2 M 3 M 5 M 10 M 20 M 30 M Frequency (Hz) Frequency Quasi-Peak Quasi-Peak Limit Quasi-Peak Difference Quasi-Peak Status 159 khz 48.25 dbµv 65.52 dbµv -17.27 db Pass 264.3 khz 46.37 dbµv 61.3 dbµv -14.92 db Pass 357.9 khz 38.67 dbµv 58.78 dbµv -20.1 db Pass 435.3 khz 42.81 dbµv 57.15 dbµv -14.34 db Pass 2.043 MHz 38.64 dbµv 56 dbµv -17.36 db Pass Frequency Average Average Limit Average Difference Average Status 159 khz 27.19 dbµv 55.52 dbµv -28.33 db Pass 264.3 khz 29.2 dbµv 51.3 dbµv -22.09 db Pass 357.9 khz 22.77 dbµv 48.78 dbµv -26 db Pass 435.3 khz 34.32 dbµv 47.15 dbµv -12.83 db Pass 2.043 MHz 32.18 dbµv 46 dbµv -13.82 db Pass Page 26 of 26