DECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Deck Design Guide. One and Two Family Residential Dwellings

Typical Deck Details

24" max from each end of the ledger. See detail 6A & 6B, typ. both ends IRC R Ledger R507.2

City of Virginia Beach, Virginia Typical Deck Details

When is a Building Permit Required? Deck Details: What Must be Submitted with a Building Permit Application?

Pulaski County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code

Typical Deck Details

Typical Deck Details Based on the City of Nixa Residential Deck Ordinance

Maryland Building Officials Association Typical Deck Details

Typical Deck Details

APPLICATION FOR A BUILDING PERMIT

ONE AND TWO FAMILY DWELLINGS Uncovered Decks July, 2007

PRESCRIPTIVE RESIDENTIAL DECK CONSTRUCTION GUIDE. Based on the 2015 International Residential Code

Prescriptive Residential Wood Deck Construction Guide Based on the 2006 International Residential Code

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

COMPOSITE RAILING INSTALLATION

installation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty

Residential Decks. Typical Deck Details DECKING REQUIREMENTS

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

Ohlson Project Property Owner: Kathy Ohlson Property Address: Deer Lake Rd. Derwood MD 20855

Perennial Wood Decking Installation Guide

PAINT & MISC. Notes. Table of Contents. Front Handrail Posts Front Handrails Closet Shelving Exterior Deck...

FREDERICK COUNTY USBC/IRC 2015

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016

FASTENERS BUILDING DEPARTMENT

3.1 General Provisions

Page 1 of 70

installation care & maintenance instructions moistureshield.com limited lifetime warranty

Sections & Details VOCABULARY

TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

Call (770) STEP 6: Caulk bolt hole within the bracket for protection from the elements.

SECTION: 15 ZONING RULE LOT AREA 6134 S.F S.F. BUILDING AREA (FOOTPRINT) LOT COVERAGE 20.2% 24.86' FRONT YARD SIDE YARD 8.

REVISION CHANGES: REV. NO. REV. DATE

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

Chapter 33: Lofts (Or Second Floors)

Step 2 - Measure and install joist hangers every 16". See Figure "B" above. Fill every hole in each

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)?

Build Outdoor Stairs. Stair Building Terms There are five basic design elements you'll need to consider when planning outdoor stairs:


Installation Instructions for. Before You Begin TOOLS REQUIRED

THE ENGINEERED WOOD ASSOCIATION

Chapter 17 - Porch Trim

COMPACT DECK. Compact Deck SOUTHERN FOREST PRODUCTS ASSOCIATION SOUTHEASTERN LUMBER MANUFACTURERS ASSOCIATION

Code Compliance Research Report CCRR-0155

Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open

Deck Designer Specification Kit For AZEK. All rights reserved copyright 2015 AZEK Building Products

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS

Description. Lesson Outcomes. Assumptions. Build a Floor. Carpenter

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

Vertical Offset Base and Safety Rail System Installation Instructions

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation

Material List for Log Complete Packages

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

How to Build Good Decks..

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

GLOSSARY OF TERMS SECTION 8

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

Solving Porch Problems

Bedroom Window Egress

BUILDING & SAFETY DIVISION 110 E. LA HABRA BLVD. LA HABRA, CA Rev. 06/17

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

Deck Designer Specification Kit For AZEK. All rights reserved copyright 2015 AZEK Building Products

Installation Instructions for. Handrail Component System

Gambrel Barn with Overhang Manual

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

The following instructions will guide you through the installation of your new vinyl railing stair kit.

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

Ocean View. Deck Planner Software Report for Simpson Template. 1 All rights reserved copyright 2017 DIY Technologies

eb^sv=qfj_bo UNIVERSITY OF WISCONSIN - STOUT COLLEGE OF SCIENCE TECHNOLOGY ENGINEERING & MATHEMATICS Architectural Technology AEC 233

APA Performance Rated Rim Boards

Modular Gazebo Kit Series Victorian or Queen Anne 12

Deck Designer Specification Kit For AZEK. All rights reserved copyright 2015 AZEK Building Products

Deck Designer Specification Kit For AZEK. All rights reserved copyright 2015 AZEK Building Products

Customer Service: Installation, Care and Maintenance

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

Load Tables, Technical Data and Installation Instructions

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

DECK PERMIT APPLICATION PACKET

A ledger/header board is the next step if you are attaching your deck to an existing structure.

Precut Workshop & Gable Manual

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2016 DIY Technologies

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

The following instructions will guide you through the installation of your new vinyl railing.

Deck Designer Specification Kit For. TimberTech. All rights reserved copyright 2015 AZEK Building Products

installation Guide What you don t Safety I-Joist Storage and Handling United states Installation Instructions for Residential Floor Systems

ATLANTIS RAIL Contact Information

G. SAMPLE DRAWINGS AND ILLUSTRATIONS INDEX

Technical Note No. 026

Glulam Connection Details

STRUCTURAL WOOD DETAILING IN CAD FORMAT

T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY

HowtoPlans. 24'x8' Walk In Chicken Coop Plan. Designed for up to 50 chickens. .org

IRC 2012 Code Compliant Wood Framed Residential details. Miss Installed Connectors with code references and remedies, discussion.

Transcription:

Date: Reported By: Project Name/Client: Year Deck was Built: I. Stairs A. Not Applicable B. Are there any visible signs of cracks, decay or over-notching? No Yes 1. If yes, where? C. Stairway width: (Hint: Residential deck stairway width shall not be < 36") D. Riser Height: E. Tread Depth: Hint: The greatest riser height or tread depth within a flight of stairs shall not exceed ⅜" 1. Is something restricting the passage of a 4" sphere between the treads? Yes No F. Are there guards and/or handrails on the stairway? Yes No 1. Is the handrail height 34"-38"? Yes No 2. Is the handrail graspable? Yes No 3. Is the opening between the balusters less than 4⅜"? No Yes 4. If a separate handrail, does the handrail return to a post or safety terminal? Yes No G. Stringer: Solid Notched www.nadra.org 5. Is there a method to safely support the required load (applied in any direction) and the deflection on the guardrail? Yes No If no, needs attention Describe: (e.g.; hardware, post connected to the footings and stringer, etc.) Hint: Solid stringers are permitted to have a total run of 13'-3" between landings or supports. Based on AWC DCA6-12, notched stringers are limited to 6' between supports. 1. Span between stringers? 2. Total rise of the stairs? Total run of the stairs? Hint: Stairs are permitted to have a total vertical rise of 12' between landings. 3. What is supporting/connecting the stringer to the deck? Hint: If Other is checked, evaluation by a design professional is recommended as the connection detail from stair stringers to the deck structure is a critical structural connection. Hardware Hardware (stringer flush) Blocking Nails, only Other 4. If the stringers are notched, does the triangular opening formed by the riser, tread & bottom rail of the guard permit the passage of a 6" sphere? No Yes H. Is there a means of artificial illumination for the stairs? Yes No I. Are there any visible signs of red rust on the hardware (fasteners or connectors)? No Yes J. If connectors are used, are all the holes filled? Yes No

II. Footings/Deck Support and Posts/Columns A. Footing/Deck Support-type? Unable to Determine Pier, only Pad or Spread No footing/improper footing Other (describe): 1. Size: Hint: Must be at least a 12"x12" or equivalent. 2. Depth/Thickness: Unable to Determine 3. Is it at least 12" below undisturbed ground Yes No Unable to determine B. Post size? 4x4 6x6 8x8 Other (e.g. metal): C. Post Height? Hint: Maximum post height is determined by the tributary load the post will carry. See AWC DCA6 for 6x6 post height maximums ( www.awc.org ). D. Any visible signs of decay, cracks or post corrosion (if metal)? No Yes: Hint: Decay or corrosion may appear just below the surface to ground interface. Cracks and decay may appear at the corner of the top of a notched post. E. What is connecting the post to the footing? Post base hardware Unable to determine Nothing Hint: Look for hardware that connects to the footing to help resist the deck from moving and has a 1" standoff base plate to help prevent decay at the post end. F. What is connecting the post to the beam? Post cap hardware Notched Other: Hint: Notching a 4x4 post for a double 2x is not permitted. Notching a 6x6 post to let-in a triple 2x or a 6x is not permitted. 1. Has a post-to-beam connector been bent or improperly modified? No Yes Hint: Bending steel in the field may cause fractures at the bend line. Fractured steel will not carry the load and must be replaced. 2. Are the beams alongside the post? No Yes If yes, is the beam attached with a metal connector to provide bearing? Yes No Hint: The beams alongside the post attached by bolts, lag screws or nails are prohibited by AWC DCA 6 and does not provide proper bearing for the beam. G. Is diagonal bracing provided on the posts and beams? Yes No Hint: Required by AWC DCA 6 at the corner posts that are greater than 2' in height. 1. If the deck is not attached to the building, what method is used for lateral support? Describe: H. Are there any visible signs of red rust on the hardware (fasteners or connectors)? No Yes I. If connectors are used, are all the holes filled with the proper fasteners? Yes No Hint: Slotted and Phillips head screws have never been appropriate for connectors.

III. Beams and Joists A. Are multiple lumber members fastened together to act as a single unit? Yes No Spacing: Fastener type (nails, bolts, screws): Hint: If bolts are used, there should be washers between the bolt head and nuts and the wood. And, the drilled holes should be no larger than 1/16" over the size of the bolt. B. Are all beam splices occurring over a support with at least 1½" of bearing? Yes No If no, describe location; (Needs attention) C. Are there connections where the joist bears on top of the beam? Yes No Type of connection: D. Joist: Size: Spacing: Span: E. What is providing the minimum 1½" of bearing under the joists? Joist Hangers Ledger strips Nothing (Needs attention) Hint: Ledger strips must be nailed directly underneath the joist with 3 or 4 nails (depending on the standard), concentrically placed right under the joist. (2015 IRC-not permitted) 1. Have any of the joist hangers been bent or modified? No Yes Hint: Bending steel in the field may cause fractures at the bend line. Fractured steel will not carry the load and must be replaced. 2. Does the hanger have "double-shear" fastening? See Figure B. Yes No a. If the hanger has "double-shear" fastening, was the correct (full length) fastener used for the joist-to-header fastener? See Figure "A" for incorrect nailing. Figure "A". Yes No (Needs attention) Hint: Full length fastener = 0.148 x 3" or 0.162 x 3½" HDG or ring shank 316 stainless steel nail or equivalent "approved" structural screws Figure "B" F. What is providing lateral support for the deck diaphragm? Lateral load hardware Freestanding deck (blocking, bracing, etc.) Nothing Unknown/Unable to Determine (Needs additional analysis) Hint: Nails in joist hangers and ledger strips are subject to withdraw from the lateral forces and do not perform well in withdraw. Therefore, the lateral forces must be addressed by some other means. G. Are there any visible signs of red rust on the hardware (fasteners/connectors)? No Yes H. If connectors are used, are all the holes filled with the proper fasteners? Yes No Hint: Slotted and Phillips head screws have never been appropriate for connectors. I. Is there any decay or rot of the wood? No Cannot Determine Yes

IV. Ledger www.nadra.org A. Not applicable: Free Standing Deck B. Not acceptable: Ledger attached to Stucco, Brick or Masonry veneer, or over Siding C. Ledger attached to; Unable to Determine a. Cannot gain access to the rim joist area due to attached ceiling (or other obstacles). b. Deck ledger is attached to structural sheathing only (typically 15/32" OSB of plywood covering a floor truss), to the web of an I-joist only, or to a cantilever. Note: If a or b, it is not possible to evaluate the deck ledger connection. A design professional is recommended to evaluate the deck ledger connection that is known to be critical to deck safety. Wood Rim Joist - Type; Fastener type; Lag Screws Machine Bolts Other Fastener diameter: Fastener spacing: Staggered: Yes No Hint: Nails, alone and carriage bolts are not acceptable. Check if seen Hint: Washers are required under the head and nuts of all bolts. Concrete CMU (Concrete Masonry Unit-e.g. block) (Needs additional analysis) Fastener type; Unable to Determine Other Fastener spacing: Staggered: Yes No Hint: Concrete & Masonry screws-not acceptable for permanent, exterior applications (exc. 316SS). 1. Are there any visible signs of red rust on the fasteners? No Yes If yes, where? D. Is flashing installed above the ledger and behind the exterior cladding, shingle fashion, and installed in such a manner as to prevent entry of water into the building? Yes No No flashing can be seen 1. Is there any decay or rot behind the ledger? No Cannot identify Yes V. Deck Boards/Deck Surface A. What type of decking? See below. Describe type and condition. Unable to Determine Wood: Wood Plastic Composite/Encapsulated-brand: PVC-brand: Other-type: B. Is there any visible sign of decay, deterioration or cracking? No Yes If yes, describe: C. Fastener type? Nails Screws Hidden Fasteners 1. If hidden fasteners are used, what lateral support has been provided? Cross Bracing Angled Bracing Blocking Other: 2. Are any nails or screws exposed? No Yes-explain D. Are there any visible signs of red rust on the fasteners? No Yes

VI. Handrail Assemblies and Guards Hint: A guard is required when the walking surface is more than 30 inches above grade. Measurement is taken up to 36 away from deck. A. What is the guard height? 36" 42" Other: Hint: Must not be less than 36 for most residential and 42 for most commercial guards. B. What is the connection between the top rail of the guard and the post? Nails: Screws: Unable to Determine No Posts Hint: Posts and proper fasteners are needed to transfer the load into the deck framing. C. Is there a "shear" connection between the posts and the frame of the deck? Yes No Bolts, only Lag Screws, only Holdown Other: Holdown "Shear" Connection Hint: Bolts or lag screws, only, failed to meet the load and deflection standards. Hint: Notched posts failed to meet the load and deflection standards. D. Is the opening between the balusters less than 4"? Yes No E. Is there any visible sign of decay, deterioration or cracking? No Yes F. Are there any visible signs of corrosion or rust in the hardware? No Yes VII. Miscellaneous Additional Comments: (e.g. Special Features such as a Hot Tub, Condition of Deck Lighting, Trim Appearance, etc.) REVISED 1/5/18 North American Deck and Railing Association PO Box 829 Quakertown, PA 18951 215.679.4884 info@nadra.org Deck Evaluation Form: http://www.nadra.org Deck Safety: http://www.nadra.org/consumers/deck_safety_month.html Deck For A Soldier: http://www.nadra.org/consumers/d4s/welcome.html ALL INFORMATION PROVIDED SHOULD BE EVALUATED BY A QUALIFIED PROFESSIONAL AND APPROVED BY THE BUILDING DEPARTMENT. EVALUATION OF THE DECK USING THIS INFORMATION DOES NOT COMPLETELY CONSTITUTE A CODE COMPLIANT DECK. IT IS INTENDED TO ASSIST BUILDERS AND INSPECTORS IN THE DECK EVALUATION PROCESS. Copyright 2018 NADRA. Not for use in educational training by anyone other than a NADRA approved instructor.