Overview per day of the programmed switching times 5 = Friday. Channel statuses / OFF

Similar documents
TR 612 S. Bedienungsanleitung (Seite 2 19) Operating Instructions (pag ) Mode d emploi (page 38 55) Bruksanvisning (S.

Radio-control universal dimmer (built-in type) Installation Instructions

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC

1. Contents Page. 2. Assembly, putting into operation, connection Control elements Display Factory setting Changing settings 6

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

Sentry Digital Timers

24HR/7 DAY YEARLY 4 CHANNEL INSTALLATION & OPERATING (4 MODULE) 16A. DIGITAL TIMESWITCH Cat. No TR644S INSTRUCTIONS

OPERATING INSTRUCTIONS Digital weekly time switch

User Instructions For TopTronic RS-10

16-Channel Yearly Time Switch TR 648 S DCF

DIN Rail Time & Twilight Switches

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units

Contents. Time switches. Presentation 2 Offer overview 4 Choice table 6 Technical data and catalogue numbers 8

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

V22 Thermostat N515/R00( )

INSTRUCTION MANUAL DT10RF OPTIMISING PROGRAMMER UK/IE OPERATING AND INSTALLATION

SELEKTA SELEKTA 170 top2 D GB F I E P NL PL. Installation and Operating Manual Digital astronomic time switch. SELEKTA 170 top2

Tempus Digital Digital Astro-Timer D GB CZ BZT28A71. Installation and Operating Manual BZT28A71

TVT280 Visual IR Thermometer Operation Flow (rev 0.5)

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

LIGHTING CONTROL PANEL

SA-027HQ 365-Day Annual Timer

MANUAL. PT Series 365 Day Annual Timer. Tel:

LK Wireless Room Control Cq

User Manual Master Clock WDP-Y2/Y4/Y8

Technical Description. DCF77 Receiver-Module 4460

UR200SI / UR200WE ENGLISH

KNX manual 1-channel flush-mounted switch actuator SU 1

WLDS-10 Mk2 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING

WLDS-10 Mk3 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING

User Manual 3X300 DIMMER MODULE DM03B02KNX

INSTALLATION & PROGRAMMING MANUAL PROGRAMMABLE TIMER (MODEL LP-2)

STYLE RA DIO France Inter - DCF

LP20RF & DIGISTAT+RF. Installation & User Guide PRINT. Radio frequency controlled room thermostat with dual channel programmer. Part number RF562DR

Radio Management. Radio Management Controller. Manual. Art.-no.: FMC 1000 GB J:

OWNERS MANUAL FOR STERLING SERIES CONTROLLERS

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

Radio motion detector comfort 1.1 m/2.2 m quicklink Order number

Style 5 Style 7. INDEP. QUARTZ MIN.-1/2 MIN. Synchro radio INSTALLATION AND OPERATING INSTRUCTIONS. Réf.: I

To Purchase This Item, Visit BMI Gaming

Always there to help you. Register your product and get support at AJB4300. Question? Contact Philips.

The room thermostat application module with 2-fold switch sensor is placed on a flush-mounted bus coupler.

EBERLE THERMOSTAT & RECEIVER

ATP Time Switch

Electrical devices may only be mounted and connected by electrically skilled persons.

Device manual Multifunction display and evaluation system FX 360. Mode/Enter

TM Analogic. Serie TM. Cod. rev

Manual. Radio Control Central Unit

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

B-Tronic EasyControl EC5401B

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

Electrical devices may only be mounted and connected by electrically skilled persons.

Please enter the identity code of your device here!

User manual CLIMATIC 60

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

Quick Reference Guide

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

AZATOM SONANCE T1 Digital Radio. DAB+/DAB/FM Radio Alarm Clock. User Manual. This manual is available to download online at

TAC 2112 Manual (GB),

Important safety instructions

P178252GB DELTA RC WIRELESS WEATHER STATION INSTRUCTION MANUAL

RISH Master 3440i/3440iDL 0.2S

SUNDIAL Light Dimmer. User's Manual

Instruction Manual Please read carefully before use and keep for future reference.

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

Please enter the identity code of your device here!

Compact Hopper Test Box Instructions TSP063doc Issue 2.1 June 2004

Sauter Components

SMARTRIPPLE Geyser Load Control Timer

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

Self-learning Room Temperature Controller Receiver

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

R9999 ROBERTS. PLL Synthesised 3 band radio with station name display. Sound for Generations. Please read this manual before use

CROSS Chassis from 160 A to 450 A

Radio BBC 3 FM BBC R2 BBC R2 BBC 3 FM 99.8 TV DVD AUX

ATS-I USER MANUAL. Tecnoelettra srl Dal Via Vioni Dimo, S.Rocco di Guastalla (RE)

Meteodata 140 S weather station

Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Quick Reference Guide

G75 Irrigation Controller

R9939 ROBERTS. PLL Synthesised 3 band mains battery radio. Sound for Generations. Please read this manual before use

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

Always there to help you. Register your product and get support at AJ7045D. Question? Contact Philips.

EQJW145. Content: 1 General. 2. Indicators and operating controls 3. Putting into service (by a technician) 4. How to operate (user)

Awning control system GFM001. Installation and Operating Instructions

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM)

DAB+ / FM RDS digital clock radio with dual alarm

KNX weather station basic V2

AURATON 2020 AURATON 2020 TX RX Plus

Comfort Digisystem User Manual. SecureStream Technology. Microphone DM05. English

Model: 5301P INSTALLATION AND OPERATION INSTRUCTIONS

Contents ... What is DAB + Digital Radio?... 2 Setting up... 3 Backlit display... 4 Using headphones... 4 Your radio Switch off...

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

Modular Devices - Indicators and Push Buttons

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry

Electronic Heat Cost Allocator GRADUS User Manual

Internal B-EN Rev A. User Guide. Leaf Aptus.

Transcription:

310 785 01 TR 611 top TERMINA 1-channel 7 day timer According to version Preprogrammed with the current time and summer/ winter norm time Safety Information The connection and installation of electrical appliances must be performed by a skilled electrician only. Any intervention into or modifications to the appliance shall lead to the lapse of all warranty rights. Comply with your national regulations and all relevant safety stipulations. Overview per day of the programmed switching times 5 = Friday Channel statuses / OFF Service voltage OK Two flashing dots Power reserve mode: Three flashing dots Selection e.g.: Auto, PROG,... Pulse, Cycle Abort input Load Display of special functions: Permanent ON/OFF Random program active z Holiday program active h Displayed only when summer/ winter time changeover is activated Summer time r Winter time f Current days of the week 1 = Monday, 2 = Tuesday,... The decision Yes confirms the selection or programming Decision No means continue

The timer is delivered in so-called sleep mode. To activate without a service voltage: Briefly press the Menu key. Activate with mains voltage: According to version the timeswitch is already pre-programmed with the actual time, the weekday, and the changeover setting for Summer / Winter time, the actual time and status display appears after selection of the National language. If the timer is not pre-programmed: First select your National language and then enter the actual date and time. First contact Selection of the national language Initial operation Activate the clock, select the national language By pressing the or key select your national language. Store your selection by pressing the key. The decision Yes, confirms the selection or programming. For programming, viewing, amending or deleting First of all read the text display. Menu selection: Select by pressing the Prog key Confirm by pressing. By pressing the key select the desired menu. e.g. New, View, Amend or Delete. Confirm your selection by pressing. Set or change: by pressing or. Store by presssing. To display the switching times: In the menu View, press the key several times. According to version According to version The decision No, means continue. Set or amend by pressing the or keys. In emergency situations only: Should you press RESET on the timer, all stored data will be deleted. However, the timer will then still display the language last selected and the summer/ winter norm time changeover last selected. Press the RES key with and a pointed object for approx. 1 second.

min. 10 C to max. + 50 C Type 1 BSTU IEC/EN 60730-2-7 42 Lithium, ap. 4 years power reserve memory locations Degree of protection II EN 60730 IP 20 EN 60529

Formation of day groups If the same switching times are active on several days of the week, they occupy just one memory location. 42 memory locations are available, e.g. Monday Friday 7.30 hrs ON. Group formation: In answer to the text question Copy, decide by pressing the key that the day program should be copied to another day of the week. The Mixed programming of switching, pulse and cycle times is allowed. When programming an ON and OFF switching time, e.g. 9 AM, a switchoff at 9 AM always has priority. Program review: Following programming the timer makes a program review back to midnight and then sets the correct switching status. Programming the switching time Switching times for lighting systems, machines, ventilation systems, alarm systems etc. Store Example: Switching on the lighting of a sports hall on Mon.,Tues.,Thurs., Fri. from 7.30h until 12h. Programming example: Select Prog by pressing the key. Select New by pressing the or. Select ON or OFF by pressing or. Store your selection by pressing. Set the hours and minutes by pressing the or key. Store selection by pressing. To store one day of the week only: Select weekday by pressing or. Select store by pressing. Store by pressing To copy to other days of the week: Store copy by pressing. Select weekday by pressing or. Store by pressing To leave out a day of the week, skip by pressing the key. Finally select the store display by pressing. Store your selection by pressing.

Effect of the random program: The random program causes the timer to switch between programmed pairs of switches (ON and OFF). The random on an off times range between approx. 10 mins. and 120 min. The random time always begins with OFF. Symbol z flashes when the random program is effective. Random ON Permanent ON or OFF random or holiday program Read the text display first of all In the menu Man, select by pressing the or key the function manual, permanent, random or holiday. Confirm your selection by pressing the key. To cancel a function: Select the function clear. Store your selection by pressing. Random OFF Via the automatic menu AUTO only Example: Random start 19.30 h ON Example: Random finish 6.00 h OFF Effect of the holiday program: The holiday program has the effect that the timer does not switch on the connected consumer unit between the programmed start and finish (stipulation of year, month, day). Start and finish of the program is always midnight on the day that is programmed. Example: 25.3. national holiday. Programming: start 25.3. finish 25.3. If the holiday program is active, the corresponding channel and holiday symbol h are displayed flashing on the automatic menu. Press the two keys for approx. 1 s Press both keys for approx. 2 s Manual preselection: Press keys simultaneously Channel C1 switches alternately ON or OFF. Symbol appears. Manual preselection is corrected again by the stored program. Permanent OFF Cancellation of manual preselection/ permanent switching: Briefly press the keys shown above.

Effect of the pulse program: The pulse time can be set within the range 1 to 59 seconds. Symbol flashes as long as the pulse program is active Pulse program e. g.: for breaktime signals, ventilation systems, flushing systems, bell controls etc. Switch-off delay Program: 7.00 until 17.30 h and pulse at 17.30 h pulse ON, duration 15 s Switch-on delay Example: Switch-on at 7.00 h 15 s Program: To switch on from 7.00 until 17.30 h and pulse, OFF at 7.00 h pulse duration 15 s Example: Switch off at 17.30 h 15 s Viewing the pulse times Only possible in the menu PULSE Day group formation If the same pulse switching times are effective on several days of the week, they occupy one pulse memory location only, e.g.: Mon., Tues., Wed., Fri., pulse time 7.30 h. 32 memory locations are available for pulse programming. Always read the text display first of all. You will be provided with programming help. Confirm your selection by pressing the key.

Effect of the cycle program: The clocking and pause times can be set separately. The settable times are max. 99 minutes and 59 seconds.the cycle program has the effect that between two programmed times, day of week start and day of week finish, the cycle program is active. The cycle program always begins with a switch on. 16 memory locations are available to you. The symbol is active. flashes when the cycle program duration Cycle program Cyclically recurring time functions within the scope of a timer, e.g.: slow flashing indicator, water treatment, advertisement lighting Brightness variations at lighting installations may arise in the cycling mode. In this case actions to reduce these effects have to be taken (for example reduction of the load or extension of the cycle time). More than five switching operations per minute are not admissible without additional EMC interference measures. Example cycle start: Monday 7.30 h ON pause Select by pressing the key Cycle. Set cycle start by pressing the keys or. Example cycle finish: Friday 16.30 h OFF Set cycle duration (Min./sec.) by pressing the keys or. Set cycle pause (Min./sec.) by pressing the keys or. Set cycle finish by pressing the keys or. Viewing the cycle times: Possible in the menu Cycle only! N.B.: If two cycle times are programmed in which the start and finish times overlap, it is always the cycle time that starts first that is executed. Example: Cycle time 1, programmed from: Mo to Thu Cycle time 2, programmed from: Tue to Fri. Only cycle time 1 is effective, cycle time 2 is not accepted.

Setting/ correcting the date and time summer/winter time Automatic summer/winter time correction According to version the timer is preprogrammed ex-works complete with the change-over. Should you switch off the automatic facility or wish to alter it, first of all read the text display. Select by pressing or. Store by pressing. Read the text display first of all. Select by pressing the key or key. Store by pressing the key. Free Prog to select sum/win changeover other than EUR-GB-USA. Select sum/win, and after with sum/win. Store with. Select rule FREE with buttons or. Input month and weeks for sum/win. Store with. E.g. Month = March Week 4 = fourth week Week 5 = last week in month Note: In sum/win free Prog the time change is set automatically at sunday 2 AM. Time change is not available. TIMEGUARD LTD, Victory Park, 400 Edgware Road London NW2 6ND Tel. 0181/4508944; Fax: 0181/4525143 PETER WARBURTON PTY. LIMITED, 64 Brittania Road, Castle Hill NSW 2154, Australia, Tel.: (02) 9899 2908, Fax: (02) 9899 4486