Three Phase Induction Motor Drive Using Single Phase Inverter and Constant V/F method

Similar documents
Wireless Speed Control of an Induction Motor Using Pwm Technique with Gsm

Simulation of Speed Control of Induction Motor with DTC Scheme Patel Divyaben Lalitbhai 1 Prof. C. A. Patel 2 Mr. B. R. Nanecha 3

A Comparative Study of Sinusoidal PWM and Space Vector PWM of a Vector Controlled BLDC Motor

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

Open Loop V/F Control of Induction Motor based on PWM Technique

A Switched Boost Inverter Fed Three Phase Induction Motor Drive

A VARIABLE SPEED PFC CONVERTER FOR BRUSHLESS SRM DRIVE

PWM Generation using PIC16F877A for Bidirectional V/F control of Single-Phase Induction Motors

DsPIC based Fixed Speed Induction Motor Drive

Module 7. Electrical Machine Drives. Version 2 EE IIT, Kharagpur 1

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online):

Nicolò Antonante Kristian Bergaplass Mumba Collins

ISSN: [Shukla* et al., 6(10): October, 2017] Impact Factor: 4.116

A New Generation VLSI Approach for V/F Control of Three-Phase Induction Motor

Development of Variable Speed Drive for Single Phase Induction Motor Based on Frequency Control

CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE

Sensorless Control of BLDC Motor Drive Fed by Isolated DC-DC Converter

Stability of Voltage using Different Control strategies In Isolated Self Excited Induction Generator for Variable Speed Applications

Harmonic Analysis of Sine PWM and hysteresis current controller

SINGLE PHASE BRIDGELESS PFC FOR PI CONTROLLED THREE PHASE INDUCTION MOTOR DRIVE

SVPWM Based Speed Control of Induction Motor with Three Level Inverter Using Proportional Integral Controller

Type of loads Active load torque: - Passive load torque :-

Driving and Controlling of three Phase Induction Motor with the Help of Single Phase Supply

EE 410/510: Electromechanical Systems Chapter 5

Speed Control of BLDC Motor Using FPGA

Reduction of Torque Ripple in Trapezoidal PMSM using Multilevel Inverter

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL

Closed Loop Control of Three-Phase Induction Motor using Xilinx

Simulation of Solar Powered PMBLDC Motor Drive

Analysis of Advanced Techniques to Eliminate Harmonics in AC Drives

Space Vector PWM Voltage Source Inverter Fed to Permanent Magnet Synchronous Motor

3.1.Introduction. Synchronous Machines

Power Factor Improvement with Single Phase Diode Rectifier in Interior Permanent Magnet Motor

TRACK VOLTAGE APPROACH USING CONVENTIONAL PI AND FUZZY LOGIC CONTROLLER FOR PERFORMANCE COMPARISON OF BLDC MOTOR DRIVE SYSTEM FED BY CUK CONVERTER

Modeling & Simulation of PMSM Drives with Fuzzy Logic Controller

Analysis of an Economical BLDC Drive System

Brushless DC Motor Drive using Modified Converter with Minimum Current Algorithm

VIENNA RECTIFIER FED BLDC MOTOR

Modeling and Simulation Analysis of Eleven Phase Brushless DC Motor

An Induction Motor Control by Space Vector PWM Technique

A Dynamic Modeling Permanent Magnet Synchronous Motor Drive System

Sensorless Speed Control Scheme for Induction Motor Drive Using DC link Measurements

DIGITAL SIGNAL PROCESSOR BASED V/f CONTROLLED INDUCTION MOTOR DRIVE

CURRENT FOLLOWER APPROACH BASED PI AND FUZZY LOGIC CONTROLLERS FOR BLDC MOTOR DRIVE SYSTEM FED FROM CUK CONVERTER

Simulation and Dynamic Response of Closed Loop Speed Control of PMSM Drive Using Fuzzy Controller

Vienna Rectifier Fed BLDC Motor

Speed control of Induction Motor Using Push- Pull Converter and Three Phase SVPWM Inverter

Performance Enhancement of Sensorless Control of Z-Source Inverter Fed BLDC Motor

Efficiency Optimized Brushless DC Motor Drive. based on Input Current Harmonic Elimination

Experiment 3. Performance of an induction motor drive under V/f and rotor flux oriented controllers.

Index Terms: Vector control scheme, indirect vector control scheme, Scalar control, Marine propulsion I. INTRODUCTION

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROLLERS

Sascha Stegen School of Electrical Engineering, Griffith University, Australia

A NOVEL SWITCHING PATTERN OF CASCADED MULTILEVEL INVERTERS FED BLDC DRIVE USING DIFFERENT MODULATION SCHEMES

International Journal of Advance Engineering and Research Development

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

BLDC Motor Drive with Power Factor Correction Using PWM Rectifier

International Journal of Advance Engineering and Research Development

Control of Electric Machine Drive Systems

IN MANY industrial applications, ac machines are preferable

HIGH PERFORMANCE CONTROL OF AC DRIVES WITH MATLAB/SIMULINK MODELS

AC Drive Technology. An Overview for the Converting Industry. Siemens Industry, Inc All rights reserved.

ANALYSIS OF POWER QUALITY IMPROVEMENT OF BLDC MOTOR DRIVE USING CUK CONVERTER OPERATING IN DISCONTINUOUS CONDUCTION MODE

Journal of Engineering Technology

SPEED CONTROL OF PERMANENT MAGNET SYNCHRONOUS MOTOR USING VOLTAGE SOURCE INVERTER

Simulation and Dynamic Response of Closed Loop Speed Control of PMSM Drive Using Fuzzy Controller

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

DESIGN OF A VOLTAGE-CONTROLLED PFC CUK CONVERTER-BASED PMBLDCM DRIVE for FAN

ROTOR FLUX VECTOR CONTROL TRACKING FOR SENSORLESS INDUCTION MOTOR

A Novel Four Switch Three Phase Inverter Controlled by Different Modulation Techniques A Comparison

Comparative Analysis of Space Vector Pulse-Width Modulation and Third Harmonic Injected Modulation on Industrial Drives.

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies

Voltage and Current Harmonic Variations in Three-phase Induction Motors with Different Stator Coil Pitches

Design of A Closed Loop Speed Control For BLDC Motor

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

Low Switching Frequency Pulse Width Modulation For Induction Motor Drives

A Sliding Mode Controller for a Three Phase Induction Motor

Design and implementation of Open & Close Loop Speed control of Three Phase Induction Motor Using PI Controller

Performance Analysis of SPWM and SVPWM Based Three Phase Voltage source Inverter. K. Latha Shenoy* Dr. C.Gurudas Nayak** Dr. Rajashekar P.

Digital Control of Permanent Magnet Synchronous Motor

Analysis of Indirect Temperature-Rise Tests of Induction Machines Using Time Stepping Finite Element Method

POWER ELECTRONICS. Converters, Applications, and Design. NED MOHAN Department of Electrical Engineering University of Minnesota Minneapolis, Minnesota

Digital PWM Techniques and Commutation for Brushless DC Motor Control Applications: Review

Matlab Simulation of Induction Motor Drive using V/f Control Method

Induction motor control by vector control method.

ELG2336 Introduction to Electric Machines

A NEW C-DUMP CONVERTER WITH POWER FACTOR CORRECTION FEATURE FOR BLDC DRIVE

Volume 1, Number 1, 2015 Pages Jordan Journal of Electrical Engineering ISSN (Print): , ISSN (Online):

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering Vol. 2, Issue 6, June 2013

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

A COMPARISON STUDY OF THE COMMUTATION METHODS FOR THE THREE-PHASE PERMANENT MAGNET BRUSHLESS DC MOTOR

UG Student, Department of Electrical Engineering, Gurunanak Institute of Engineering & Technology, Nagpur

Analysis of Voltage Source Inverters using Space Vector PWM for Induction Motor Drive

Conventional Paper-II-2013

EE POWER ELECTRONICS UNIT IV INVERTERS

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Transcription:

Three Phase Induction Motor Drive Using Single Phase Inverter and Constant V/F method Nitin Goel 1, Shashi yadav 2, Shilpa 3 Assistant Professor, Dept. of EE, YMCA University of Science & Technology, Faridabad, India 1 PG Student[PSD], Dept. of EE, YMCA University of Science & Technology, Faridabad, India 2,3 ABSTRACT: The induction machine is used as the most common motors in different applications. It is the workhorse of industry. But they require much more complex methods of control, more expensive and higher rated power converters than DC and permanent magnet machines.this paper presents control of a three phase induction motor using single phase inverter with constant volts hertz control (V/F) method and pulse width modulation. Frequency control with flux proportional to V/f and voltage proportional to the speed seems to be the best solution. PWM gives a high quality output voltage. Single phase inverter output gives a better feed to the induction machine without extra components needed on the motor and also produces a higher starting torque and reduced speed pulsation amplitude. Keywords: PWM inverter, volts per hertz, Total Harmonic Distortion I.INTRODUCTION In the present time, in the most of the applications, AC machines are preferable over DC machines due to their simple and most robust construction without any mechanical commutators [1].Induction motors are widely used in many residential, commercial, industrial and utility applications. This is because the motor have low manufacturing cost, wide speed range, high efficiency and robustness [2]. However, the use of induction motors also has its disadvantages, these lie mostly in its difficult controllability, due to its complex mathematical model, its non linear behaviour during saturation effect and the electrical parameter oscillation which depends on the physical influence of the temperature. Induction motor is essentially a constant-speed motor. Its speed of rotation is determined by the synchronous speed. In many industrial applications wide variation in motor speed is required. This can be achieved by varying the stator frequency of the motor thereby varying the synchronous speed. Therefore, Motor control is a significant [3]. There are various control techniques available for the speed control of induction motor, like changing stator poles technique, torque vector control and several others. In this paper we will use a V/f control technique for the control of three phase induction motor. For this we have to kept voltage and frequency ratio constant. There would required to increase the maximum allowed current of the speed control unit thereby making it possible to sell their products to a wider range of customers with different needs for example control of pumps and more powerful fans, so here it is important to minimize the losses created in the machine/motor. AC drives, inverters and adjustable frequency drives all terms that are used to control the speed of AC motor. AC drives receive AC power and convert it to an adjustable frequency, adjustable voltage output for controlling motor operation. The three common inverter types are Current source inverter (CSI), Voltage source inverter(vsi), Pulse width modulation inverter(pwm). 50 -HZ AC AC-TO-DC CONVERTER (To any DC voltage) DC-TO-AC COVERTER (To any frequency) AC motor Fig.1 A block diagram of a variable speed control system. Copyright to IJAREEIE www.ijareeie.com 8339

II. DYNAMIC MODELING OF THREE PHASE INDUCTION MOTOR Let us first consider the stator circuit. The resistance Rs of the stator winding is (for all practical purposes) equal in all three phases. From the law of induction it follows that the part of the stator voltage which is not dissipated in the stator resistance will build up a flux in the stator winding. Hence, with v s s as the stator voltage space vector, the following relation must hold Where: Figure1. Per phase equivalent circuit of poly phase Induction Machine V 1 = stator terminal voltage E 1 = stator emf generated by resultant air-gap flux R 1 = stator effective resistance X 1 = stator leakage reactance R m = iron core-loss resistance Xm = magnetizing reactance R' 2 = rotor effective resistance referred to stator X' 2 = rotor leakage reactance referred to stator V rb = emf due to the saturable iron bridges in the rotor slots I 0 = sum of magnetizing I 0 X and core-loss I 0 R current components I 1 = stator current I 2 = rotor current referred to stator Some of the important steady-state performance characteristics of a poly phase induction motor include the variation of current, speed, and losses as the load-torque requirements change, and the starting and maximum torque. Performance calculations can be made from the equivalent circuit. All calculations can be made on a per-phase basis; Total quantities can be obtained by using an appropriate multiplying factor. The equivalent circuit of (Fig. 1) is usually employed for the analysis. The core losses, most of which occur in the stator, as well as friction, wind age, and stray-load losses are included in efficiency calculations. The power-flow diagram for an induction motor is given in (Fig. 1.1), in which m 1 is the number of stator phases, Φ 1 is the power-factor angle between V 1 and I 1, Φ 2 is the power-factor angle between E 1 and I 2, T is the internal electromagnetic torque developed, ω s is the synchronous angular velocity in mechanical radians per second, and ω m is the actual mechanical rotor speed given by ω s (1 - s). The total power Pg in watts transferred across the air gap from the stator is the difference between the electrical power input Pi and the stator copper loss. P g is thus the total rotor input power, which is dissipated in the resistance R 2 / s of each phase so that the total power Pg in watts transferred across the air gap from the stator is the difference between the electrical power input Pi and the stator copper loss. Pg is thus the total rotor input power, which is dissipated in the resistance R2 / s of each phase so that P = m (I ) = Tω (2.1) Where T is the internal electromagnetic torque developed by the machine, and ω s is the synchronous angular velocity in mechanical radians per second. Subtracting the total rotor copper loss, which is m 1 (I 2 ) R 2 = sp g from (Eq. 1.1) for Pg, we get the internal mechanical power developed: P = P (1-s) = Tω = m (I ) R (1 s) (2.2) Copyright to IJAREEIE www.ijareeie.com 8340

To mechanical power and the fraction this much power is absorbed by a resistance of R 2 (1-s)/s, which corresponds to the load. From (Eq. 2.2), we can see that, of the total power delivered to the rotor, the fraction (1-s) is converted S is dissipated as rotor copper loss. We can conclude then that an induction motor operating at high slip values will be inefficient. The total rotational losses including the core losses can be subtracted from Pm to obtain the mechanical power output Po that is available in mechanical form at the shaft for useful work P = P P = T ω (2.3) The per-unit efficiency of the induction motor is then given by: n = (2.4) III. SPEED CONTROL OF THREE PHASE INDUCTION MOTOR The angular speed in rad / s of an induction AC machine mechanical speed is given by: ω = (1 s)ω This shows us that there are two possibilities for speed regulation of an induction motor, altering the slip s (typical < 5%), or the synchronous speed ω s. Studying different control techniques: Voltage control, Frequency control, Vector control, Changing stator poles, Rotor Resistance, Doubly fed motor Although various induction motor control techniques are in practice today, the most popular control technique is by generating variable frequency supply, which has constant voltage to ratio frequency ratio. This technique is popularly known as V/F control [4].In this technique torque developed by the Induction motor is directly proportional to the V/F ratio. If we vary the voltage and frequency, keeping their ratio constant, then the torque produced by induction motor will remain constant for all the speed range. Fig 2.shows the torque-speed characteristics of the induction motor with V/F control. The voltage and frequency reaches the maximum value at the base speed [5].We can drive the induction motor beyond the base speed. But by doing so only frequency varies but not voltage. Hence the ratio of V/F will no longer remain constant. Since the torque developed by the induction motor is directly proportional to the V/F ratio will not remain constant throughout the speed. Power electronic circuits are best suited for this kind of control. Copyright to IJAREEIE www.ijareeie.com 8341

A. System overview Figure2. Torque-speed characteristics of the induction motor IV. CONTROL & SIMULATION RESULTS The basic block schematic of three-phase induction motor drive is shown in fig.3. It has 4 pulse discrete PWM Generator, Single phase inverter. In the proposed work the single-phase bridge inverter is designed using IGBT. IGBT switches are used because, they have high switching frequency [2]. Discrete Fourier is used to compute magnitude and phase of fundamentals. In this distorted current waveform convert into equivalent harmonic component. By which, we can find out THD. Output of inverter is feeded to three phase induction motor model for speed control. For creating 3 rd phase adding a capacitor branch in series of 2 nd phase. Fig3. Control Scheme of IM B. Power circuit design Most motors are designed to for sine wave AC supply and the inverter output should be as near to sinusoidal as possible. It is therefore best to choose the control wave with sine shape to give a PWM pattern in which the pulse width is sinusoidal modulated throughout the half cycle. To obtain balanced output voltages in a PWM Generator, the triangular voltage waveform is compared with sinusoidal control voltages.output of Discrete PWM generator act as gate pulses for IGBT Bridge. Copyright to IJAREEIE www.ijareeie.com 8342

Fig 4. 4 Pulses Discrete PWM Generator Fig5. Comparison of sine and triangular wave Fig6. Output waveform of discrete PWM Generator The most frequently used single-phase inverter circuit consists of two legs, one for each phase, as shown in (Fig. 7). The output of each leg, for example V AN (with respect to the negative dc bus), depends only on V d and the switch status the output voltage is independent of the output load current since one of the two switches in a leg is always on at any Copyright to IJAREEIE www.ijareeie.com 8343

instant. Here, ignore the blanking time required in practical circuits by assuming the switches to be ideal. Therefore, the inverter output voltage is independent of the direction of the load current. Fig 7. IGBT Bridge Fig 8.Simulation result of Induction Machine start Simulation results shows higher starting torque produced as compare to other methods of speed control, also PWM inverter reduce speed pulsation V.CONCLUSION Three phase induction motor control by using single phase inverter is very economical. Switching from volt control to frequency control (volt / hertz) method would make it possible to achieve the increase in current supplied to the induction machine, thereby decreasing heat inside the enclosure. The 3-phase output gives a better feed to the induction machine without extra components needed on the motor. It has been observed that 3-phase output from the PWM inverter will reduce speed pulsation and produce a higher starting torque. BY using single phase inverter instead of three phase inverter, reduces the total quantity of IGBT s.hence, overall system cost reduces. There will be no need for manual adjustment of each unit, but the technical complicity is going in the wrong direction Copyright to IJAREEIE www.ijareeie.com 8344

REFERENCES [1] Rodolfo Echavada, Sergio Horta, Marc0 Oliver, A Three phase motor drive using IGBT s and Constant V/F speed control with slip regulation, IEEE, 0-7803-3071-4/95 1995 [2] Farzan Rashidi, Sensorless speed control of induction motor drives using robust and adaptive neuro-fuzzzy based intelligent controller,ieee international conference on industrial technology (ICIT), 2004, pp. 617-627. [3] J.B Gupta, Theory and performance of Electrical machines, S.K. kataria and sons [4] Ku. Trupti Deoram Tembhekar A constant v/f open loop and closed loop speed control of a three phase induction motor drive [5] Muhammad.H.Rashid, Power electronicscircuits.devices,and application, Prentice Hall; 3 edition (August 14, 2003). [6] Mohan N, Undeland, T. M. and Robbins, W. P., Power Electronics, John Wiley & Sons Inc., USA, (2003) [7] Ned Mohan, Tore M. Undelad, William P. Robbins, 1995, Power Electronics Converters,Applications and Design, Wiley, New York [8] Nisit K. DE,Prashanta K.Sen Electrics drives Asoke K. Ghose Prentice Hall of india private limited. [9] M.S.Aspalli, Asha.R, P.V. Hunagund three phase induction motor drive using igbts and constant v/f method International Journal of Advanced Research in Electrical, Vol. 1, Issue 5,PP.230-235 November 2012. [10] Shilpa V. Kailaswar, Prof. R.A.Keswani Speed Control of Three Phase Induction motor by V/f Method for Batching Motion System International Journal of Engineering Research and Applications (IJERA) Vol. 3, Issue 2, pp.1732-1736. March April 2013 [11] Alfredo, Thomas A. Lipo and Donald W. Novotny, A New Induction Motor V/f Control Method Capable of High- Performance Regulation at Low Speeds IEEE Trans. Industry Applications, Vol. 34,PP.536-540 No. 4 July/ August 1998 Copyright to IJAREEIE www.ijareeie.com 8345