Power Quality Improvement using Active shunt Power filter using PI Controller

Similar documents
A Hysteresis based Active Shunt, Passive Series Hybrid Filter for Power Quality Improvement

Exploration in Power Quality Furtherance on Shunt Active Power Filter

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

Enhancement of Power Quality Using Advanced Series Active Power Filters

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

5DESIGN PARAMETERS OF SHUNT ACTIVE FILTER FOR HARMONICS CURRENT MITIGATION

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Power Quality improvement of a three phase four wire system using UPQC

Improvement of Power Quality Using a Hybrid Interline UPQC

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

A Time Domain Reference-Algorithm for Shunt Active Power Filters

Review on Shunt Active Power Filter for Three Phase Four Wire System

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

HARMONIC ELIMINATION IN THREE PHASE SYSTEM BY MEANS OF A SHUNT ACTIVE FILTER

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

Reduction of Voltage Imbalance in a Two Feeder Distribution System Using Iupqc

A Novel Fuzzy Variable-Band Hysteresis Current Controller For Shunt Active Power Filters

Control Of Shunt Active Filter Based On Instantaneous Power Theory

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Indirect Current Control of LCL Based Shunt Active Power Filter

HYSTERESIS CONTROL FOR CURRENT HARMONICS SUPPRESSION USING SHUNT ACTIVE FILTER. Rajesh Kr. Ahuja

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

Multi Level Inverter Based Active Power Filter for Harmonic Reduction

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Synchronous Reference Frame Control Algorithm Based Four -Leg Inverter DSTATCOM For Power Quality Improvement

Power Control and Quality Management in DG Grid Interfaced Systems

Design of Shunt Active Filter to Improve Power Quality using Pq Theory

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

Cascaded Multilevel Inverter based Active Filter for Power Line Conditioners using Instantaneous mitigates

IMPROVEMENT OF POWER QUALITY USING CUSTOM POWER DEVICES

2020 P a g e. Figure.2: Line diagram of series active power filter.

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

PLL Synchronization with PID Controller Based Shunt Active Power Line Conditioners

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Design of Hybrid Active Filter for Power Quality Improvement of Electrical Distribution System Using Fuzzy Logic Controller

Design of UPQC with constant frequency controlled scheme for removal of Total Harmonic Distortion

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

Delivering Clean and Pure Power

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

A Review on Power Quality Improvement in Distribution System using UPQC

ICCCES Application of D-STATCOM for load compensation with non-stiff sources

Comparison of Various Reference Current Generation Techniques for Performance Analysis of Shunt Active Power Filter using MATLAB Simulation

Improvement of Power Quality using Unified Power Quality Conditioner with Distributed Generation

ISSN Vol.03,Issue.42 November-2014, Pages:

COMPENSATION OF POWER QUALITY PROBLEMS USING ACTIVE POWER FILTER

SHUNT ACTIVE POWER FILTER

PERFORMANCE OF DISTRIBUTION STATIC COMPENSATOR IN LOW VOLTAGE DISTRIBUTION SYSTEM

SHUNT COMPENSATOR USED FOR POWER QUALITY IMPROVEMENT

Harmonics Elimination Using Shunt Active Filter

Unified Power Quality Conditioner (UPQC) for Power Distribution Systems

Control Strategy for a cross phase connected and a conventional UPQC

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

Power-Quality Improvement with a Voltage-Controlled DSTATCOM

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Power Quality Improvement By Using DSTATCOM Controller

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

A MATLAB-SIMULINK APPROACH TO SHUNT ACTIVE POWER FILTERS

16th NATIONAL POWER SYSTEMS CONFERENCE, 15th-17th DECEMBER,

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Mitigation of Line Current Harmonics Using Shunt Active Filter With Instantaneous Real and Reactive Power Theory

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

STATCOM BASED ON REDUCTION OF PQ ISSUES IN MICRO GRID APPLICATION SYSTEMS

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

ABSTRACT I. INTRODUCTION

Dynamic Modeling and Simulation of Unified Power Quality Conditioner

Implementation of UPQC for Voltage Sag Mitigation

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Neural Network Controlled Hybrid Active Power Filter with Distorted Mains for PMSM Drive

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

PI Controller Based Shunt Active Power Filter with Cascaded Multilevel Inverter

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

ISSN Vol.03,Issue.07, August-2015, Pages:

Power Quality Improvement in Fourteen Bus System using UPQC

Power Quality Improvement of Grid Connected Wind Energy System by Statcom for Balanced and Unbalanced Linear and Nonlinear Loads

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

Chapter 2 Shunt Active Power Filter

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Fuzzy Logic and PI Controller Based Shunt Active Power Filter For Harmonic Elimination

Power Quality Improvement using Shunt Passive Filter

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

Control of Shunt Active Power Filter for Improvement of Power Quality

Multiconverter Unified Power-Quality Conditioning System: MC-UPQC T.Charan Singh, L.Kishore, T.Sripal Reddy

Shunt Active Power Filter for Compensation of System Harmonics

Performance Analysis of UPQC for Non-Linear Load by Using MATLAB

ISSN Vol.04,Issue.16, October-2016, Pages:

Fuzzy Logic Control of APF for Harmonic Voltage Suppression in Distribution System

Transcription:

Power Quality Improvement using Active shunt Power filter using PI Controller Viki S. Patel M.tech Scholar Electrical Engineering, U.V Patel College of Engineering, Kherva, India patel.viki4@gmail.com Abstract In This paper we use PI controller for improve the power quality using shunt active power filter. And PWM pattern generation is based on carrier less hysteresis based current control to obtain the switching signals to the voltage sourced PWM converter. Make a simulation of shunt active power filter in MATLAB. Index Terms Active power filter, PI controller, MATLAB I. INTRODUCTION The application of power electronics devices such as arc furnaces, adjustable speed drives, Computer power supplies etc. are some typical non-linear characteristic loads used in most of the industrial applications and are increasing rapidly due to technical improvements of semiconductor devices, digital controller and flexibility in controlling the power usage. The use of the above power electronic devices in power distribution system gives rise to harmonics and reactive power disturbances. The harmonics and reactive power cause a number of undesirable effects like heating, equipment damage and Electromagnetic Interference effects in the power system. The conventional method to mitigate the harmonics and reactive power compensation is by using passive LC filters but this method has drawbacks like large size, resonance problem and fixed compensation behavior. The solution of these problem is the active power filter (APF) comes in to the picture, which gives promising solution to compensate for the above adverse effects of harmonics and reactive power simultaneously by using suitable control algorithms. This report contains issues related with electrical system about power quality and available solutions to mitigate those issues. II. POWER QUALITY ISSUE The PQ issue is defined as any occurrence manifested in voltage, current, or frequency deviations that results in damage, upset, failure, or misperation of end-use equipment. Almost all PQ issues are closely related with PE in almost every aspect of commercial, domestic, and industrial application. Equipment using power electronic devise are residential appliances like TVs, PCs etc. business and office equipment like copiers, printers etc. industrial equipment like programmable logic controllers (PLCs), adjustable speed drives (ASDs), rectifiers, inverters, CNC tools and so on [5]. The Power Quality (PQ) problem can be detected from one of the following several symptoms depending on the type of issue involved. Lamp flicker Frequent blackouts Sensitive-equipment frequent dropouts Voltage to ground in unexpected Locations Communications interference Overheated elements and equipment III. SOLUTION OF POWER QUALITY PROBLEM There are two approaches to the mitigation of power quality problems. The first approach is called load conditioning, which ensures that the equipment is made less sensitive to power disturbances, allowing the operation even under significant voltage distortion. The other solution is to install line-conditioning systems that suppress or counteract the power system disturbances. Passive filters have been most commonly used to limit the flow of harmonic currents in distribution systems. They are usually custom designed for the application. However, their performance is limited to a few harmonics, and they can introduce resonance in the power system. Among the different new technical options available to improve power quality, active power filters have proved to be an important and flexible alternative to compensate for current and voltage disturbances in power distribution systems. The idea of active filters is relatively old, but their practical development was made possible with the new improvements in power electronics and microcomputer control strategies as well as with cost reduction in electronic components. Active power filters are becoming a viable alternative to passive filters and are gaining market share speedily as their cost becomes competitive with the passive variety. Through power electronics, the active filter introduces current or voltage components, which cancel the harmonic components of the nonlinear loads or supply lines, respectively. Different active power filters topologies have been introduced and many of them are already available in the market. IV. POWER FILTER TOPOLOGIES Depending on the particular application or electrical problem to be solved, active power filters can be implemented as shunt type, series type, or a combination of shunt and series active filters (shunt-series type). These filters can also be combined with passive filters to create hybrid power filters [3]. IJEDR1401160 International Journal of Engineering Development and Research (www.ijedr.org) 885

The shunt-connected active power filter, with a self-controlled dc bus, has a topology similar to that of a static compensator (STATCOM) used for reactive power compensation in power transmission systems. Shunt active power filters compensate load current harmonics by injecting equal-but opposite harmonic compensating current. In this case the shunt active power filter operates as a current source injecting the harmonic components generated by the load but phase-shifted by 180 [2]. Series active power filters were introduced by the end of the 1980s and operate mainly as a voltage regulator and as a harmonic isolator between the nonlinear load and the utility system. The series-connected filter protects the consumer from an inadequate supply-voltage quality. This type of approach is especially recommended for compensation of voltage unbalances and voltage sags from the ac supply and for low-power applications and represents an economically attractive alternative to UPS, since no energy storage (battery) is necessary and the overall rating of the components is smaller. The series active filter injects a voltage component in series with the supply voltage and therefore can be regarded as a controlled voltage source, compensating voltage sags and swells on the load side. In many cases, series active filters work as hybrid topologies with passive LC filters. If passive LC filters are connected in parallel to the load, the series active power filter operates as a harmonic isolator, forcing the load current harmonics to circulate mainly through the passive filter rather than the power distribution system. The main advantage of this scheme is that the rated power of the series active filter is a small fraction of the load kva rating, typically 5%. However, the apparent power rating of the series active power filter may increase in case of voltage compensation [1]. V. BASIC COMPENSATION PRINCIPLE OF SHUNT ACTIVE POWER FILTER Vs is Rs,Ls il Non -linear load ic Rc,Lc Active Power filter Cdc Figure 1 Shunt active power filters Basic compensation principle. Figure 2 Shunt active power filter-shapes of load, source and desired filter current wave forms Figure 1 shows the basic compensation principle of a shunt active power filter. It is controlled to draw / supply a compensating current i c from / to the utility, so that it cancels current harmonics on the AC side, and makes the source current in phase with the source voltage. Figure.2. shows the different waveforms. Curve A is the load current waveform and curve B is the desired mains current. Curve C shows the compensating current injected by the active filter containing all the harmonics, to make mains current sinusoidal [6]. IJEDR1401160 International Journal of Engineering Development and Research (www.ijedr.org) 886

VI. PI CONTROL SCHEME Non-linear load Rs,Ls RL LL 3-phase source Rc,Lc PWM converter s1 s3 s5 a b s4 s6 s2 c Cdc ig1 ig4 ig3 ig6 ig5 ig2 Control circuit Vdc Vdcref Figure 3 Schematic diagram of shunt active filter. The complete schematic diagram of the shunt active power filter is shown in figure 3 gives the control scheme realization. The actual capacitor voltage is compared with a set reference value. ig1 ig4 I*sa Isa x Imax/Vm Vsa Imax PI controller e - + Vdcref ig3 ig6 I*sb Isb x Vsb Vm Peak detector Vsa Vsb Vsc Vdc ig5 I*sc x Vsc ig2 Isc Hysteresis controller Figure 4 APF Control scheme with PI controller. The error signal is fed to PI controller. The output of PI controller has been considered as peak value of the reference current. It is further multiplied by the unit sine vectors (u sa, u sb, and u sc ) in phase with the source voltages to obtain the reference currents (i sa *, isb *, and isc * ). These reference currents and actual currents are given to a hysteresis based, carrier less PWM current controller to generate switching signals of the PWM converter [2]. The difference of reference current template and actual current decides the operation of switches. To increase current of particular phase, the lower switch of the PWM converter of that particular phase is switched on, while to decrease the current the upper switch of the particular phase is switched on. These switching signals after proper isolation and amplification are given to the switching devices. Due to these switching actions current flows through the filter inductor L, to compensate the Harmonic current and reactive power of the load, so that only active power drawn from the c source. The compensator is switched ON at t=0.05s and the integral time square error (ITSE) performance index is used for optimizing the and coefficients of the PI controller. The optimum values (Kp and K ) are found to be 0.2 and 9.32, respectively, i which corresponds to the minimum value of ITSE. VII. SIMULATION SYSTEM PARAMETERS TABLE 1 SIMULATION SYSTEM PARAMETERS SYSTEM PARAMETERS VALUE Source voltage(vs) 325V(peak) System frequency(f) 50Hz Source impedance(rs,ls) 0.1Ω,0.15mH Filter impedance(rc,lc) 0.4Ω,3.35mH IJEDR1401160 International Journal of Engineering Development and Research (www.ijedr.org) 887

Load impedance(rl,ll) Reference Dclink voltage(vdcref) DC link capacitance 20Ω,20mH 680V 2000μF VIII. RESULT Figure 5 source voltage Figure 6 line current IJEDR1401160 International Journal of Engineering Development and Research (www.ijedr.org) 888

Figure 7 compensating current using pi controller Figure 8 voltage and current in phase with pi controller after compensation IX. CONCLUSION This paper has presented a simulation study of PI based hysteresis current controlled active shunt power filter for harmonic and reactive power compensation of the non linear load. Using PI controller the source current THD is reduce 28% to 2.2%.PI controller based shunt active power filter in MATLAB. It is found from simulation results that shunt active power filter improves power quality of the power system by eliminating harmonics and reactive current of the load current, which makes the load current sinusoidal and in phase with the source voltage. REFERENCES [1] W. M. Grady, M. J. Samotyj, and A. H. Noyola, Survey of active power line conditioning methodologies, IEEE Transactions on Power Delivery, vol. 5, no. 3, Jul. 1990, pp. 1536 1542. [2] S. Jain, P. Agarwal, and H. O. Gupta, Design simulation and experimental investigations on a shunt active power filter for harmonics and reactive power compensation, Electrical Power Components and Systems, vol. 32, no. 7, Jul. 2003, pp. 671 692. [3] F. Z. Peng, H. Akagi, and A. Nabae, Study of active power filters using quad series voltage source PWM converters for harmonic compensation, IEEE Transactions on Power Electronics, vol. 5, no. 1, Jan. 1990, pp. 9 15. [4] H.Akagi, Trends in active power line conditioners, IEEE Transactions on power Electronics, vol 9, no 3, 1994, pp 263-268. IJEDR1401160 International Journal of Engineering Development and Research (www.ijedr.org) 889

[5] S. K. Jain, P. Agrawal, and H. O. Gupta, Fuzzy logic controlled shunt active power filter for power quality improvement, Proceedings of Institute of Electrical Engineers, Electrical Power Applications, vol. 149, no. 5, 2002. [6] L.A.Morgan, J.W.Dixon & R.R.Wallace, A three phase active power filter operating with fixed switching frequency for reactive power and current harmonics compensation, IEEE Transactions on Industrial Electronics, vol.42, no.4, August 1995, pp 402-408. [7] B. Singh, A. Chandra, and K. Al-Haddad, Computer-aided modeling and simulation of active power filters, Electrical Machines and Power Systems, vol. 27, 1999, pp. 1227 1241. [8] B. Singh, A. Chandra, and K. Al-Haddad, A review of active filters for power quality improvement, IEEE Transactions on Industrial Electronics, vol.46, no 5, Oct 1999, pp1-12. [9] R. M. Duke and S. D. Round, The steady state performance of a controlled current active filter, IEEE Transactions on Power Electronics, vol. 8, Apr. 1993, pp. 140 146. [10] J.W.Dixon, J.J.Garcia & L.Morgan, Control system for three phase active power filter which simultaneously compensates power factor and unbalanced loads, IEEE Transactions on Industrial Electronics, vol.42, no.6, 1995, pp636-641. [11] K. Chatterjee, B. G. Fernandes, and G. K. Dubey, An instantaneous reactive volt-ampere compensator and harmonic suppressor system, IEEE Transactions on Power Electronics, vol. 14, no. 2, Mar. 1999, pp. 381 392. [12] D.A.Torey& A.M..Al-Zamel, A single phase active filter for multiple nonlinear load, IEEE Transactions on Power Electronics, vol.10, May 1995, pp.263-272. [13] V.Soares, P.Verdelho & G.D. Marques, An instantaneous active and reactive current component method of active filter, IEEE Transactions on Power Electronics, vol.15, no.4, July 2000, pp.660-669. [14] LEE C.C., Fuzzy logic in control systems: fuzzy logic controller part I and II, IEEE Trans. Syst. Man Cybern, 1990, vol.20, pp.404-435. IJEDR1401160 International Journal of Engineering Development and Research (www.ijedr.org) 890