IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Similar documents
Loop-Powered Isolators for Standard Signals

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

5 years! Modular Housings. IsoAmp PWR A Warranty

5 years! Modular Housings. VariTrans P Warranty

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

User and Safety Manual ProLine P224xx P1

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

IsoAmp 11000/ The Universal Isolation Amplifier.

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

VariTrans P D1 TRMS

VariTrans P V. Safe and Sound.

It s TRUE! True RMS measurement with the new AC/DC high-voltage transmitters of the VariTrans P TRMS series. Isolation Amplifiers.

IsoAmp 11000/ Universal isolation amplifiers for ±20 mv to ±10 V or ±20 ma input signals.

IsoAmp 3000/4000. The Advantages The dynamic range extends into the negative, allowing for strictly linear transmission

Switching power supplies CP range, Linear power supplies CP-L range. Content

SINEAX / EURAX 2I1 Passive DC signal isolator

Technical Information Barrier RB223

Coupling Relays and Converters

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

SINEAX TI 807 Passive DC signal isolator

Custom "Compact" range with display CD20 Custom Part number

Type CP-S, CP-C & CP-A Switch mode

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

CP-T range Product group picture

LED Driver Linear / area fixed output

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

CP-T range Benefits and advantages

No-wear isolation of potentials in terminal block design

Analog signal converters CC-E I/I

LED Driver Linear / area fixed output

MINI-PS AC/24DC/1.3

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

CP-E range Benefits and advantages

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

Power supply CP-T 48/20.0 Primary switch mode power supply

LED Driver Compact fixed output

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Power supply CP-T 24/20.0 Primary switch mode power supply

Temperature transmitter itemp PCP DIN rail TMT 121

Power supply CP-D 24/4.2 Primary switch mode power supply

Primary switch mode power supplies Product group picture

Maconic Shunt Resistors

B850 Boiler House Energy Monitor

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Power supply CP-E 24/2.5

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

02/11/2015

LED Driver Compact fixed output. Udriver LC 25/30/35/40W 600/700/800/900mA fixc SC ADV ADVANCED series

LED Driver Compact fixed output 4,5 83,5 93. Ordering data. Type

LED Driver Constant voltage

GAMMA 20 DIGITAL MULTIMETER

Power supply CP-E 24/20.0

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Current / residual current and voltage transformers. Current / residual current and voltage transformers

JUMO Wtrans Receiver with Wireless Data Transmission

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

LED Driver Compact fixed output

P5201 Universal Programmable Transmitters with Galvanic Isolation

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

E Series 9.00 (1/2) E series

QUINT-PS-24DC/24DC/10

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

LED Driver Compact fixed output

Power supply CP-T 24/40.0 Primary switch mode power supply

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

For non-electrical quantities

38 Series - Relay interface modules A. Features /

02/11/2015

PHOENIX CONTACT - 09/2009

Electronic timer CT-TGD.22

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Subject to changes 11/2003 Page 1/7

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

Measuring current transformers of the W, W series

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

MINI-PS AC/2X15DC/1

LED control gear Compact fixed output. Uconverter LCI 20 W 350/500/700 ma TEC SR TEC series

Signal conditioner - MACX MCR-UI-UI-NC

High Performance Current Transducer ITL 900-T = A

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Transcription:

ProLine Interface Technology Loop-Powered Isolators for Standard Signals For isolation of 0(4)... 20 ma standard current signals on up to 3 channels. The Task If no power supply is available, the galvanic isolation of 0(4)... 20 ma standard-current signals requires investing in power supplies. The Problems Many products only provide loop-powered isolation with an insufficient degree of accuracy. But the need for high measurement accuracy requires an isolator design which meets the highest demands. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage. The Solution The Knick with transformer-based isolation offer properties which no other loop-powered DC isolator can even come close to. Thanks to the 0.2 % fault class and an internal voltage requirement of just 1.2 V, this isolator can be used for a broad range of applications. The Housing The A2 modular housing with a width of 22.5 mm for max. three isolators offers optimum space usage in multichannel mode. The A3 modular housing for one isolator is just 17.5 mm wide. The full encapsulation guarantees maximum reliability even in extreme conditions. The Advantages The galvanic isolation in the IsoTrans 41 is achieved by using a passive isolator that obtains its power as a voltage drop from the measurement signal. This saves on power supply devices and cabling and increases the reliability accordingly. The Technology The devices work with a serial chopper generator in the current path. This avoids the accuracy-reducing current losses of normal parallel connected generators, considerably reduces the voltage drop, and ensures accurate transmission of even the lowest currents. The Application Galvanic isolation of input and output circuits of the supply voltage for 2-wire transmitters for the addition or other coupling of signals at different potentials to eliminate double-ground compensation currents when insulation and test voltage are insufficient of high-potential signal sources for battery-powered devices with a central battery 60

Facts and Features No power supply No mains influences Extremely high accuracy Broad range of applications Current transmission from 2 µa to 50 ma Maximum reliability No unnecessary heating and therefore maximum service life of components Marginal loading of measured signal Voltage drop of only 1.2 V Low signal delay Space-saving thanks to multi-channel versions Modular housing with up to three channels Quality ensured by computer-controlled testing 5-year warranty 5 Year Warranty! 61

ProLine Interface Technology Loop-Powered Isolators for Standard Signals Product Line Device Order no. 1-channel, A2 modular housing (width: 22.5 mm) 41 A2 / 1 2-channel, A2 modular housing (width: 22.5 mm) 41 A2 / 2 3-channel, A2 modular housing (width: 22.5 mm) 41 A2 / 3 Power supply None, supply from input signal Specifications data s Min. operating current < 2 µa Voltage drop Overload capacity 0(4) 20 ma 0 50 ma Approx. 1.2 V (20 ma) Approx. 1.6 V (50 ma) 100 ma, 20 V data Offset < 5 µa Residual ripple 1) 0(4) 20 ma /max. 15 V (corresponds to a 750 Ω load) 0 50 ma /max. 15 V (corresponds to a 300 Ω load) < 1.5 mv pp / ma Transmission behavior Transformation error 2) Load error Rise / Fall time 0.02 % meas. val. 0.02 % meas. val. per 100 Ω Approx. 2.5 ms at 500 Ω load resistance Isolation Test voltage 2.5 kv AC Working voltage (basic insulation) 500 V DC across any inputs and outputs with overvoltage category II and pollution degree 3 according to EN 61010-1 (for type 41 A2/3 across neighboring inputs and outputs with pollution degree 2 inside the housing, degree 3 outside). For applications with high working voltages, take measures to prevent accidental contact and make sure that there is sufficient distance or insulation between adjacent devices. 62

Specifications (continued) Standards and approvals Surge withstand 5 kv 1.2/50 µs according to IEC 255-4 Immunity to interference 8 kv according to IEC 801-2 Further data Ambient conditions Ambient temperature -25 +80 C Design Indoor use 3) ; relative humidity 5 95 %, no condensation; max. altitude 2000 m (air pressure: 790 1060 hpa) 4) Modular housing, 22.5 mm wide, screw terminals See dimension drawings for further measurements Ingress protection Protection with terminal covers according to DIN 40050: housing: IP 40, terminals: IP 20 Mounting Connection Weight Snap-on mounting for 35 mm DIN rail according to EN 60715 or M4 screw mounting Connecting screws M 2.5 x 8 with self-lifting clamps, max. conductor cross section 2 x 2.5 mm 2 solid or 2 x 1.5 mm 2 stranded with ferrule 41 A2 / 1: approx. 140 g 41 A2 / 2: approx. 190 g 41 A2 / 3: approx. 210 g 1) Slightly increased residual ripple can occur with loads < 5 ohms 2) Temperature range -10 +70 C 3) Closed, weather-protected operating areas (stationary operation), water or wind-driven precipitation (rain, snow, hail, etc.) excluded 4) Lower air pressure reduces the allowable working voltages. 63

ProLine Interface Technology Loop-Powered Isolators for Standard Signals Transfer Function V in [V] voltage drop 15 10 Transmission = 1:1 I in = 20 ma I out = 20 ma V in V out + 1.2 V 5 0 0 5 10 15 V out [V] voltage Response to Square Step of Current [ms] Rise / Fall time (10 90 %) of output current 3.5 3 2.5 2 1.5 1 0.5 0 1 ma 0 4 ma 0 20 ma 0 0 100 200 300 400 500 600 700 [ohm] Load 64

Block Diagram + + Current input - Z 20 V 1 µf Generator 100 khz 1:1 1 µf Z 20 V - Current output Typical Applications Potential isolation with impressed current, current output Potential isolation with impressed input current, voltage output I in I out I in V out I out = I in V out = R I in Potential isolation in two-wire systems Power supply Transducer 65

ProLine Interface Technology Loop-Powered Isolators for Standard Signals Typical Applications (continued) Potential isolation for current addition with impressed currents I in 1 I in 2 e.g., grounded I in 3 I out = I in1 + I in2 + I in3 e.g., grounded 66

Dimension Drawings and Terminal Assignments Modular housing type A2 22.5 Ø 4.4 88 Channel 1 1 + 2 3 4 + 89 80 76.6 81 53 75 Channel 2 5 + 6 7 8 + Screw mounting with extendable lugs 99 Snap-on mounting on 35-mm DIN rail to EN 60715 Channel 3 9 + 10 11 12 + M 2.5 x 8 screw terminals with self-lifting clamps, max. conductor cross section 2 x 2.5 mm 2 solid or 2 x 1.5 mm 2 stranded with ferrule All dimensions in mm 67