Novel Impulse Response Measurement Method for Stringed Instruments

Similar documents
Whole geometry Finite-Difference modeling of the violin

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007

On the Bridge-Hill of the Violin

Modelling and Synthesis of Violin Vibrato Tones

On the function of the violin - vibration excitation and sound radiation.

Quarterly Progress and Status Report. On the body resonance C3 and its relation to top and back plate stiffness

The acoustics of mandolins

WARPED FILTER DESIGN FOR THE BODY MODELING AND SOUND SYNTHESIS OF STRING INSTRUMENTS

Reliability of the input admittance of bowed-string instruments measured by the hammer method

Examination of Organ Flue Pipe Resonator Eigenfrequencies by Means of the Boundary Element Method

Direction-Dependent Physical Modeling of Musical Instruments

The Physics of Musical Instruments

A METHOD FOR A MODAL MEASUREMENT OF ELECTRICAL MACHINES

Sound Analysis. D. Noon

Time-domain simulation of the bowed cello string: Dual-polarization effect

Torsional waves in a bowed string

Proceedings of Meetings on Acoustics

Maximizing LPM Accuracy AN 25

Physics 140 Winter 2014 April 21. Wave Interference and Standing Waves

Techniques to reduce electromagnetic noise produced by wired electronic devices

Acoustics of pianos: An update of recent results

AN5E Application Note

Quarterly Progress and Status Report. A look at violin bows

EXPERIMENTAL AND NUMERICAL ANALYSIS OF THE MUSICAL BEHAVIOR OF TRIANGLE INSTRUMENTS

MEASURING DIRECTIVITIES OF NATURAL SOUND SOURCES WITH A SPHERICAL MICROPHONE ARRAY

Reed chamber resonances and attack transients in free reed instruments

16.3 Standing Waves on a String.notebook February 16, 2018

Technique for the Derivation of Wide Band Room Impulse Response

A Look at Un-Electronic Musical Instruments

Physics in Entertainment and the Arts

INTRODUCTION TO COMPUTER MUSIC PHYSICAL MODELS. Professor of Computer Science, Art, and Music. Copyright by Roger B.

PC1141 Physics I. Speed of Sound. Traveling waves of speed v, frequency f and wavelength λ are described by

Quarterly Progress and Status Report. Observations on the transient components of the piano tone

Modal damping identification of a gyroscopic rotor in active magnetic bearings

Sound, acoustics Slides based on: Rossing, The science of sound, 1990.

Proceedings of Meetings on Acoustics

DESIGN, CONSTRUCTION, AND THE TESTING OF AN ELECTRIC MONOCHORD WITH A TWO-DIMENSIONAL MAGNETIC PICKUP. Michael Dickerson

Application of optical measurement techniques for experimental modal analyses of lightweight structures

Investigation on Sensor Fault Effects of Piezoelectric Transducers on Wave Propagation and Impedance Measurements

Principles of radiation of bowed instruments and challenges for modelling. FAMA 2017 Berlin

Simulation and auralization of broadband room impulse responses

On the accuracy reciprocal and direct vibro-acoustic transfer-function measurements on vehicles for lower and medium frequencies

Musical Instrument of Multiple Methods of Excitation (MIMME)

EffectofBassBarTensiononModalParametersofaViolin stopplate

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007 VIRTUAL AUDIO REPRODUCED IN A HEADREST

THE BEATING EQUALIZER AND ITS APPLICATION TO THE SYNTHESIS AND MODIFICATION OF PIANO TONES

Development of Shock Acceleration Calibration Machine in NMIJ

VSA Papers Summer 2005 Vol. 1, No. 1 BRIDGE TUNING: METHODS AND EQUIPMENT

A modal method adapted to the active control of a xylophone bar

Development of a Package for a Triaxial High-G Accelerometer Optimized for High Signal Fidelity

Convention Paper Presented at the 130th Convention 2011 May London, UK

Vibration Fundamentals Training System

MICROPHONE ARRAY MEASUREMENTS ON AEROACOUSTIC SOURCES

Room impulse response measurement with a spherical microphone array, application to room and building acoustics

How to perform transfer path analysis

Sound Radiation Characteristic of a Shakuhachi with different Playing Techniques

Enhancing the capability of primary calibration system for shock acceleration in NML

Body Vibration of the Violin What Can a Maker Expect to Control?

Acoustic Resonance Analysis Using FEM and Laser Scanning For Defect Characterization in In-Process NDT

SETUP I: CORD. Continuous Systems

Tolerances of the Resonance Frequency f s AN 42

UNIVERSITY OF TORONTO Faculty of Arts and Science MOCK EXAMINATION PHY207H1S. Duration 3 hours NO AIDS ALLOWED

Physics of Music Projects Final Report

A five-microphone method to measure the reflection coefficients of headsets

Impact of String Stiffness on Virtual Bowed Strings

Structure of Speech. Physical acoustics Time-domain representation Frequency domain representation Sound shaping

Fundamentals of Music Technology

Musical Acoustics, C. Bertulani. Musical Acoustics. Lecture 14 Timbre / Tone quality II

EWGAE 2010 Vienna, 8th to 10th September

Modal Parameter Estimation Using Acoustic Modal Analysis

Post-processing and center adjustment of measured directivity data of musical instruments

Digital Equalization of the electric violin:

Dept. of Computer Science, University of Copenhagen Universitetsparken 1, DK-2100 Copenhagen Ø, Denmark

Low frequency sound reproduction in irregular rooms using CABS (Control Acoustic Bass System) Celestinos, Adrian; Nielsen, Sofus Birkedal

On the sound production of the timpani

Spherical mapping of violins

CHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION

Impact sound insulation: Transient power input from the rubber ball on locally reacting mass-spring systems

Resonant characteristics of flow pulsation in pipes due to swept sine constraint

Chapter PREPTEST: SHM & WAVE PROPERTIES

A Parametric Model for Spectral Sound Synthesis of Musical Sounds

Transfer Function (TRF)

PIV STUDY OF STANDING WAVES IN A RESONANT AIR COLUMN

SECTION A Waves and Sound

Convention Paper Presented at the 120th Convention 2006 May Paris, France

Sound 05/02/2006. Lecture 10 1

Proceedings of Meetings on Acoustics

1319. A new method for spectral analysis of non-stationary signals from impact tests

Modeling of the part-pedaling effect in the piano

PHYS102 Previous Exam Problems. Sound Waves. If the speed of sound in air is not given in the problem, take it as 343 m/s.

Proposal. Analysis of Parallel Vibration Paths with Potential Application to Vehicle Noise. Reduction. Submitted to. The Engineering Honors Committee

Part 2: Second order systems: cantilever response

BEAMFORMING WITHIN THE MODAL SOUND FIELD OF A VEHICLE INTERIOR

Chapter 2. Meeting 2, Measures and Visualizations of Sounds and Signals

Experimental evaluation of inverse filtering using physical systems with known glottal flow and tract characteristics

Void Reduction in Reflow Soldering Processes by Sweep Stimulation of PCB Substrate

Response spectrum Time history Power Spectral Density, PSD

ANALYSIS AND EVALUATION OF IRREGULARITY IN PITCH VIBRATO FOR STRING-INSTRUMENT TONES

Natural Frequency Measurement

The study on the woofer speaker characteristics due to design parameters

Transcription:

Novel Impulse Response Measurement Method for Stringed Instruments Friedrich Türckheim, Thorsten Smit, Carolin Hahne, and Robert Mores PACS: 43.75.Yy, 43.75.Zz, 43.75.De, 43.75.Gh ABSTRACT Department of Media Technology, Hamburg University of Applied Sciences, Hamburg, Germany friedrich.tuerckheim@haw-hamburg.de This paper introduces a measurement technique which delivers highly reproducible impulse responses of stringed instruments. The method bases on exciting the dampened strings at the bowing or plucking position by means of a thin copper wire which is pulled until it breaks. Taking into account the longitudinal and torsional movements of a bridge caused by string deflection, such stimulus of an instrument is close to the musical application. On the basis of the string-wire geometry, measurement setups can be exactly specified and individually adjusted, allowing for highly accurate repetition in comparative studies. The setup, including a fully automated exciting apparatus as well as a silent quadrochord, is described in detail. Furthermore, the method is compared with the commonly used impact hammer method. Finally, an application in the context of a research project on violin sound quality is briefly described, where the technique is used to measure binaural impulse responses of violins. 1. INTRODUCTION Measuring transfer functions of stringed instruments has always been a basic issue in musical acoustics and has been repeatedly approached with different methods [1], [2], [3]. The experimental determination of transfer functions of stringed instruments is still necessary as long as there are no complete and reliable physical models. Presuming that the resonator is a linear system (Fig. 1), its frequency response and impulse response offer a lot of information on timbre, reverberation and directional radiation properties. Impulse responses are used as starting point for modeling approaches for example, or to investigate the relationship between particular transfer functions and the instruments quality. The so called resonance profile which is the magnitude spectrum of the impulse response shows the individual resonance constellation or energy distribution of an instrument (Fig. 2). The resonance profile can be treated as the instrument s acoustic fingerprint and is therefore closely related to the quality of the instrument. x(t) String oscillation H(jω) Resonance body y(t) Acoustic radiation Figure 1: The resonance body treated as an LTI system. For scientific purposes measurement techniques for string instrument body responses have to meet certain requirements: (i) a high degree of reliability is required in order to allow the comparison of measurements as well as the exact repetition of measurements at different times or places. (ii) Particularly for investigations on musical instruments a high validity is necessary. The choice of an appropriate point of excitation, for instance, determines whether an obtained impulse response is meaningful or not, in other words, to what extend it corresponds to an instrument s natural transfer behavior. (iii) The excitation signal has to have an adequate linear and broadband frequency behavior. (iv) In case of acoustic recordings, the excitation mechanism should be as quiet as possible. (v) The excitation mechanism must not add additional mass or affect the instrument s vibration characteristics in any other way. This demand is especially important for stringed instruments because of their complex and sensitive resonance behavior [4]. H(jω) / 30 Helmholtz resonance 20 10 0-10 -20 Body resonances 'a' formant Plate and bridge resonances Nasal range 300 400 600 800 1k 2k 3k 4k 5k 6k Figure 2: The resonance profile of a mid-priced violin (E. Roth, 1977). There are several methods for achieving transfer functions of stringed instruments; however, they only partially meet the above mentioned requirements. Moreover, the results are often not reasonably comparable due to the wide variety of different techniques. The majority of investigators target the bridge when exciting string instruments because this is the location where the bulk of energy is decoupled from the strings. Methods with excitation signals of long duration usually do not meet the fifth requirement mentioned above, e.g. Dünnwald exciter [1], MLS signals [2], and sinusoidal forces [5], [6] [7]. In contrast, driving methods where bowing machines are used excite the instruments in a natural manner [8], [9]; but, due to the complex bowing process and the long measurement times, these meth- ICA 2010 1

Proceedings of 20th International Congress on Acoustics, ICA 2010 ods are neither very reliable nor practicable. Hence, the most reliable and therefore most established measuring method for impulse responses is to excite an instrument at the side of the bridge by means of an impact hammer, used e.g. in [4], [10], or in [11]. During this excitation, all strings are damped. Typically, the impact hammer has a force transducer to record the input signal f (t). The frequency response of the device under test (DUT) can then be calculated with H( jω) = Y ( jω), ω = 2π f, (1) X( jω) where Y ( jω), for instance, is the radiated sound pressure or the structure mobility. The single impulse facilitates free vibration of the instrument and a sufficiently high bandwidth (up to about 8 khz), depending on what type of impact hammer is used. However, this method also has three serious disadvantages: (1) The impact excitation does not entirely represent the natural motion of the bridge as it occurs when it is driven by a plucked or bowed string. But especially the bridge motion and the bridge eigenmodes are known to have an important influence on overall sound characteristics [5], [12]. The eigenmodes can be of longitudinal, flexural and torsional nature. Using an impact hammer, the bridge is approximately driven only in one direction, namely the one according to the transversal string oscillation (x-motion, Fig. 3). However, the string oscillation causes several types of bridge motion and there is a need to differentiate: due to the impulse of the Helmholtz motion which runs along the string twice an oscillation, the string tension varies. This fact results in a changed downward force (y-direction, Fig. 3) to the bridge and therefore is immediately applied to the top plate [13]. In [14] this excitation is called indirect excitation. Another result of the string vibration is a tilting movement of the bridge due to the string deflection. This movement in z-direction (Fig. 3) actually does not significantly affect body resonances but causes a radiation of the bridge itself which then effectively represents an acoustic dipole. Additionally, the bridge wings vibrate due to the string deflection of the e- and g-string. This is even visible when pulling a string aside with a finger. more authentic excitation the proposed procedure is also very inexpensive and easy to reiterate. In Section 2 the basic principles of the wire technique are explained. In addition, an apparatus is described which allows automated string plucking. In Section 3 the reliability of the method is shown and compared with the impact hammer method. Furthermore, the wire method and the hammer method are compared in terms of resulting bridge motion (z-direction, Fig. 3) using a laser intensity measurement setup. Finally, an application of the authors is briefly described where the proposed method is used to obtain binaural impulse responses of violins. 2. METHOD The method presented here is based on a simple principle: a string is pulled aside at the bowing or plucking position by means of a thin copper wire of specified diameter. When the wire breaks, an impulse runs along the string and hits the bridge. This method allows for easy repetitions at different times or places due to well definable geometric relations, i.e. the plucking point, a clear pulling direction, and an easily measurable angle between wire and strings. During the measurement, all strings are damped by means of a small rubber mat located near the beginning of the fingerboard (Fig. 4). This type of damping has a minimum weight and does not affect the fingerboard modes. The distance between damping material and bridge is chosen such that the remaining fundamental oscillation of the string takes place above the frequency range of interest. Plucking an e-string of a violin will result in a fundamental oscillation of about 11 14 khz if the rubber mat is placed 15 20 mm from the bridge. For the sake of completeness it should be mentioned that damping the strings in such a manner results in a new, free oscillating spring-mass system of the coupled strings whose fundamental frequency is at about 120 Hz. This low-frequency oscillation can be tolerated since it occurs below the frequency range of interest in most cases and can be compensated for (see below). An alternative damping with fixed strings at the fingerboard would result in a disturbance of the fingerboard modes. Figure 3: The violin bridge and its directions of motion. (2) Even though the impact hammer approach is probably believed to be the most reliable among the commonly used methods, there remain difficulties to reproduce or communicate the exact point of excitation, the impact angle and the impact speed. (3) Depending on the weight of the hammer and the type of the hammer suspension, there remains a risk of double hits which occasionally occur due to bridge backward motion. Furthermore, too heavy hammers may cause a bridge displacement. Taking into consideration the above-mentioned factors, it becomes obvious to involve a string in the excitation process and hence to drive the instruments in a more natural way. So, this paper aims at introducing an alternative approach using a wire which pulls a string aside until the wire breaks. Apart from the Figure 4: String deflection by using a copper wire. Here, conventional enameled copper wire is used for excitation. It turned out that wires with diameters between 0.09 mm and 0.19 mm are best suitable for excitation, see also Section 3. If the diameter is too large, the string can be pulled down from the bridge. This is also the reason why the authors mostly use the e-string as excitation string in case of violins. The pulling direction is usually set to the respective bowing direction, in up-bow or in down-bow direction. The authors decided to use a driving point at a distance of 10 mm to the top edge of the bridge. Measurements have shown that a slight variation of the plucking point of about 5 mm in each direction does not affect the resulting frequency response in the frequency range up to 10 khz. 2 ICA 2010

Just like in other transfer function measurements the wire impulse method also requires knowledge of the input signal. The quotient of the output frequency response, i.e. the Fourier transform of the radiated sound pressure for example, and the frequency response of the input signal is the frequency response of the DUT. Determining the input signal at the bridge requires an additional measurement. Here, the input signal is obtained by means of a vibration-free instrument made of solid steel named quadrochord (Fig. 5). It has four strings, a variable mensur length, and a bridge which is equipped with piezoelectric elements. These pickups, connected to an impedance converter, allow for direct recordings of string oscillations. For measuring the input excitation signal of the wire impulse, the strings are damped in the same way as described above. The wire excitation is also the same as described above. Once the input signal is determined for a specific setup (string type, wire diameter, excitation position) it can be used for all individual measurements due to the homogeneity of the copper wires used. The tensile strength needed to break the wire will always be the same for each measurement. Fig. 6 shows exemplary measurements of the input signal in the frequency domain (violin e-string, wire diameter of 0.14 mm). Here, the outstanding peak at about 12.5 khz represents the fundamental frequency of the string part between damping mat and bridge. Figure 5: Steel quadrochord used for input signal measurements. -130 Figure 6: Frequency behavior of the input wire excitation signal measured on the quadrochord. The proposed method is characterized by a very high degree of measurement reproducibility due to the good manufacturing accuracy of the wire and hence the corresponding, unchanged string displacement. Such high precision allows for good repetition accuracy even when wires are pulled manually (see also Section 3). Nevertheless, the authors of the paper have developed a fully automated exciting mechanism with which string instruments can be plucked [15]. The plucking apparatus consists of a solenoid with a movable iron/aluminium core which is accelerated and slowed down by the Lorentz force. The apparatus is nearly noiseless and due to a microprocessor control it can be triggered from another room. The advantage of a fully automated excitation is obvious: excluding human inaccuracies as well as perturbing noise of action enhance precision of measurements. This is also represented in increased correlation coefficients between measurements. Here, the Fourier spectra of 15 recorded measurements have been compared pairwisely. Fig. 7 shows the correlation coefficients of manually pulled wire excitation in comparison to the automated excitation. Corr. Coeff. 1 0.99 0.98 0.97 0.96 0.09 mm 0.14 mm Wire diameter Figure 7: Box whisker diagram of the correlation coefficients of pairwisely compared spectra: manually pulling (left) and automated pulling (right) for two exemplary wire diameters. 3. RESULTS In an anechoic chamber impulse responses of a high-quality violin (M. Schleske, Op.96, 2008) have been measured. The acoustic radiation of the instrument has been recorded using a condenser microphone placed directly above the bridge at a distance of 500 mm. At the same time as part of a parallel project microphone signals of an artificial head have been recorded, too. The artificial head has been placed at the playing position, as shown in Fig. 8. The violin has been clamped only at two points related to the normal playing situation: at the neck and at the chin rest. Fig. 9 shows the acoustic radiation recorded with the condenser microphone in the frequency domain for different wire diameters. In order to compare the wire excitation with the impact hammer method, the bridge has also been driven on the soundpost side by means of a miniature impact hammer (type: Dytran 5800SL, head weight: 2 g, ball bearing suspension). Fig. 10 shows the average resonance profile in comparison to wire excitation (0.18 mm diameter). The resonance profiles are normalized to their respective input signals. The increased first air mode ( Helmholtz resonance ), visible in case of wire excitation, is a result of the above mentioned indirect excitation which occurs due to the string deflection. The impulse responses have been normalized such that they show the same energy in the time domain. Fig. 11a and Fig. 11b show the resonance profiles at the left and right ear of the artificial head microphone, respectively. For comparison, the frequency curves have been equalized with the inverse transfer function of the artificial head. Figure 8: Violin impulse response measurement in anechoic room using a dummy head microphone. 3.1 Bridge Deflection Measurement In order to examine the bridge mobility in z-direction (Fig. 3) for both types of excitation further measurement series have been done by means of a specific laser intensity technique. The ICA 2010 3

Proceedings of 20th International Congress on Acoustics, ICA 2010-55 -65-75 -85-95 10 3 Figure 9: Acoustic radiation of a high-priced violin. Results for wire excitations with different diameters. From top down, diameters in mm: 0.18 (light gray), 0.17, 0.16, 0.15, 0.13, 0.12, 0.11 (black). direct displacement of the bridge is obtained by measuring the intensity of a laser beam after it has passed a tiny aluminum plate (weight: 0.05 g) bonded to the bridge (Fig. 12). In [16] the technique is described in detail. The deflection of the bridge set into relation to the respective excitation input signals yields the frequency-dependent receptance (i.e. the dynamic compliance). The bridge deflection has been measured at the top edge of the bridge between the two middle strings (Point A in Fig. 3). Again, the time signals of the measured deflection have been normalized to a microphone signal which has been recorded directly above the instrument (500 mm distance). Fig. 13 shows the measured receptance of the bridge in z-direction for both the wire and the impact hammer excitation. The so called bridge hill, i.e. the frequency range at about 2 to 3 khz, is clearly visible. The wire excitation yields a slight increase of the displacement amplitude of the mechanical bridge resonance which occurs at 2.5 khz [17], [18]. -50 Figure 10: Violin resonance profiles recorded with a microphone at a distance of 500 mm directly above the bridge in an anechoic chamber; black: wire excitation, gray: impact hammer excitation. a) Figure 12: Bridge deflection measurements with laser intensity (description in the text). 3.2 Application Example As mentioned above, impulse responses of string instruments are used for several scientific tasks. In a concurrent research project the authors of the paper focus on the perceived quality of violins. As part of the project, a real-time violin tool has been developed which can be used to investigate the relationship between spectral properties of the violin body and the perceived quality of the instrument [19]. The tool is based on binaural impulse responses of real violins which can be modified software-based in high resolution. The above described measurement method represents the start position for further signal processing. Using a near-field artificial head microphone located at the playing position, the measured impulse responses are as authentic as possible. Due to the complex directional characteristics of a violin, the measured transfer functions differ from one ear to the other ear. Fig. 14a and Fig. 14b show the binaural resonance profiles of a high-priced and a mid-priced violin, respectively. Again, the impulse responses have been equalized with the inverse transfer function of the artificial head microphone. b) Figure 11: Violin resonance profiles recorded with a) left ear microphone and b) right ear microphone of an artificial head; black: wire excitation, gray: impact hammer excitation. 4. SUMMARY In this paper a method for measuring impulse responses of stringed instruments has been presented. Since the string is involved in the measuring process, the proposed method is more closely related to the natural excitation of a string instrument than conventional methods. The method also meets the requirements for high-degree reliability and validity. Using copper wire for exciting the strings allows for high repetition accuracy both because of the good wire homogeneity and because of the well definable string-wire geometry. The measurement setup has been introduced in detail and first measurement results have been described, particularly in comparison to the established impact hammer method. By using a laser intensity 4 ICA 2010

-50 10 3 Figure 13: Bridge receptance in z-direction (see also Fig. 3) in case of wire excitation (black) and impact hammer excitation (gray). a) b) Figure 14: Binaural resonance profiles of a) a high-priced violin and b) a mid-priced violin. Black: left ear signal, gray: right ear signal. measurement method it could be shown that the proposed wire excitation results in different bridge motion due to the string deflection. In addition, a fully automated plucking mechanism and a specific usage for impulse responses have been described. In upcoming measurement sessions, the method has to be verified and compared against the hammer method in more detail. This will include, for example, a registration of complete directional radiation patterns of different violins and transfer function measurements of other stringed instruments, e.g. guitars. 5. ACKNOWLEDGEMENTS The authors thank the German Federal Ministry of Education and Research for funding. REFERENCES [1] H. Dünnwald, Akustische Messungen an zahlreichen Violinen und Ableitung objektiver Kriterien für deren klanglichen Eigenschaften., Ph.D. thesis, RWTH Aachen, Aachen, Germany, 1984. [2] A. Farina, A. Langhoff, and L. Tronchin, Realisation of virtual musical instruments: measurements of the impulse response of violins using MLS technique, in Proc. 2nd Int. Conf. on Acoustics and Musical Research (CIARM-95), Ferrera 1995. [3] A. Farina, A. Langhoff, and L. Tronchin, Comparison of violin impulse responses by listening to convoluted signals, in Proc. Intern. Symp. on Musical Acoustics (ISMA-95), Paris, July 1995, vol. 53, pp. 1620 1626. [4] E. V. Jansson, B. K. Niewczyk, and L. Fryden, On the body resonance C3 and its relation to the violin construction, J. Catgut Acoust. Soc., vol. 3, pp. 9 14, 1997. [5] M. E. McIntyre and J. Woodhouse, The acoustics of stringed musical instruments, Interdisciplinary Science Reviews, vol. 3, no. 2, pp. 157 173, 1978. [6] J. C. Luke, Measurements and analysis of body vibrations of a violin, J. Acoust. Soc. Am., vol. 49, pp. 1264 1274, 1971. [7] E. Jansson, I. Bork, and J. Meyer, Investigation into the acoustical properties of the violin, Acustica, vol. 62, pp. 1 15, 1986. [8] J. S. Bradley and T. W. W. Stewart, Comparison of violin response curves produced by hand bowing, machine bowing and an electromagnetic driver, J. Acoust. Soc. Am., vol. 48, pp. 575 578, 1970. [9] R. M. Lee, An investigation of two violins using a computer graphic display, Acustica, vol. 32, pp. 78 88, 1975. [10] M. Karjalainen and J. Smith, Body modeling techniques for string instrument synthesis, in Proc. Int. Computer Music Conf. (ICMC-96), Hong Kong, China, 1996. [11] C. Fritz, I. Cross, B. C. J. Moore, and J. Woodhouse, Perceptual thresholds for detecting modifications applied to the acoustical properties of a violin, J. Acoust. Soc. Amer., vol. 122, no. 6, pp. 3640 3650, 2007. [12] W. Reinicke, Die Übertragungseigenschaften des Streichinstrumentenstegs, Ph.D. thesis, Technical University of Berlin, 1973. [13] N.-E. Molin, A. O. Wåhlin, and E. V. Janssons, Transient wave response of the violin body revisited, J. Acoust. Soc. Am., vol. 90, pp. 2192 2195, 1991. [14] A. H. Benade, Fundamentals of Musical Acoustics: Second, Revised Edition, Dover Publications, 1990, ISBN: 978-0486264844. [15] T. Smit, F. Türckheim, and R. Mores, A highly accurate plucking mechanism for acoustical measurements of stringed instruments, J. Acoust. Soc. Am., vol. 127, no. 5, pp. EL222 EL226, 2010. [16] R. Mores, M. t. Straten, and A. Selk, Measuring transient structure-borne sound in musical instruments proposal and first results from a laser intensity measurement setup, in Proc. 126th Audio Eng. Soc. Conv., Munich, Germany, 2009. [17] N. H. Fletcher and T. D. Rossing, The Physics of Musical Instruments, Springer, New York, 2 edition, 1998, ISBN: 978-0387-98374-5. [18] J. Woodhouse, On the "bridge hill" of the violin, Acta Acustica united with Acustica, vol. 91, pp. 155 165, 2005. [19] F. Türckheim, T. Smit, and R. Mores, A semi-virtual violin for investigations into sound quality and musicianinstrument interaction, in Proc. Int. Computer Music Conf. (ICMC-10), New York, USA, 2010. ICA 2010 5