DIGITAL SIMULATION OF MULTILEVEL INVERTER BASED STATCOM

Similar documents
SEVERAL static compensators (STATCOM s) based on

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

SIMULATION RESULTS OF EIGHT BUS SYSTEM USING PUSH-PULL INVERTER BASED STATCOM

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

D-STATCOM FOR VOLTAGE SAG, VOLTAGE SWELL MITIGATION USING MATLAB SIMULINK

Comparison and Simulation of Open Loop System and Closed Loop System Based UPFC used for Power Quality Improvement

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Modeling of Statcom. P.M. Sarma and Dr. S.V. Jaya Ram Kumar. Department of Electrical & Electronics Engineering GRIET, Hyderabad, India

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

Power Quality Improvement in Distribution System Using D-STATCOM

Performance of Indirectly Controlled STATCOM with IEEE 30-bus System

Intelligence Controller for STATCOM Using Cascaded Multilevel Inverter

Designing Of Distributed Power-Flow Controller

Volume I Issue VI 2012 September-2012 ISSN

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 08, 2015 ISSN (online):

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

Observability & Controllability of a power system by optimizing the performance of PMUs & FACTS controller

Harmonic Reduction in Five Level Inverter Based Dynamic Voltage Restorer

Improvement in Power Quality of Distribution System Using STATCOM

Simulation of Soft Switched Pwm Zvs Full Bridge Converter

MLI HYBRID STATCOM WITH WIDE COMPENSATION RANGE AND LOW DC LINK VOLTAGE

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Modeling and Simulation of STATCOM

APPLICATION OF INVERTER BASED SHUNT DEVICE FOR VOLTAGE SAG MITIGATION DUE TO STARTING OF AN INDUCTION MOTOR LOAD

A Double ZVS-PWM Active-Clamping Forward Converter: Analysis, Design, and Experimentation

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Mitigating Voltage Sag Using Dynamic Voltage Restorer

ISSN Vol.04,Issue.08, July-2016, Pages:

Improvement Voltage Sag And Swell Under Various Abnormal Condition Using Series Compensation

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

Application of Distribution Static Synchronous Compensator in Electrical Distribution System

A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS

Power Quality Improvement in Fourteen Bus System using UPQC

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

Generation of Voltage Reference Signal in Closed-Loop Control of STATCOM

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

Enhancement of Voltage Stability & reactive Power Control of Distribution System Using Facts Devices

A NOVEL APPROACH TO ENHANCE THE POWER QUALITY USING CMLI BASED CUSTOM POWER DEVICES

MMC based D-STATCOM for Different Loading Conditions

HARMONIC contamination, due to the increment of nonlinear

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

ENHANCEMENT OF POWER FLOW USING SSSC CONTROLLER

Chapter 10: Compensation of Power Transmission Systems

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

Investigation of D-Statcom Operation in Electric Distribution System

SIMULATION COMPARISON OF CLASS D/ CLASS E INVERTER FED INDUCTION HEATING

Power Quality enhancement of a distribution line with DSTATCOM

Multilevel Inverter Based Statcom For Power System Load Balancing System

Performance Evaluation of a Cascaded Multilevel Inverter with a Single DC Source using ISCPWM

factors that can be affecting the performance of a electrical power transmission system. Main problems which cause instability to a power system is vo

To Study The MATLAB Simulation Of A Single Phase STATCOM And Transmission Line

DYNAMIC VOLTAGE RESTORER USING THREE PHASE AC-AC CONVERTER

Improving Passive Filter Compensation Performance With Active Techniques

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 05 Issue: 12 Dec p-issn:

SIMULATION OF DSTATCOM FOR POWER FACTOR IMPROVEMENT

RECENTLY, the harmonics current in a power grid can

A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions

Comparative Analysis of Multiple-pulse VSC-Based STATCOM s for Voltage-Dip Mitigation

High Frequency Soft Switching Of PWM Boost Converter Using Auxiliary Resonant Circuit

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

A Series-Connected Multilevel Inverter Topology for Squirrel-Cage Induction Motor Drive

A Hybrid Cascaded Multilevel Inverter for Interfacing with Renewable Energy Resources

Modelling of Four Switch Buck Boost Dynamic Capacitor

Indirect Current Control of LCL Based Shunt Active Power Filter

ECEN5817 Lecture 4. Transfer function H(s) ) (t) i R. (t) v R

Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

The unified power quality conditioner: the integration of series and shunt-active filters

IMPROVED TRANSFORMERLESS INVERTER WITH COMMON-MODE LEAKAGE CURRENT ELIMINATION FOR A PHOTOVOLTAIC GRID-CONNECTED POWER SYSTEM

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

Analysis and Enhancement of Voltage Stability using Shunt Controlled FACTs Controller

ACTIVE POWER ELECTRONIC TRANSFORMER A STANDARD BUILDING BLOCK FOR SMART GRID

Multilevel Current Source Inverter Based on Inductor Cell Topology

Power System Stability Enhancement Using Static Synchronous Series Compensator (SSSC)

Chapter 2 Shunt Active Power Filter

DESIGN A D STATCOM FOR VOLTAGE HARMONIC SUPPRESSION IN DISTRIBUTION SYSTEM

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

Comparison of SPWM,THIPWM and PDPWM Technique Based Voltage Source Inverters for Application in Renewable Energy

Mitigation of Voltage Sag and Swell using Distribution Static Synchronous Compensator (DSTATCOM)

A NOVEL SOFT-SWITCHING BUCK CONVERTER WITH COUPLED INDUCTOR

Chapter-5 MODELING OF UNIFIED POWER FLOW CONTROLLER. There are a number of FACTS devices that control power system

International Journal of Emerging Technology in Computer Science & Electronics (IJETCSE) ISSN: Volume 8 Issue 1 APRIL 2014.

Power Control Scheme of D-Statcom

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

Transcription:

DIGITAL SIMULATION OF MULTILEVEL INVERTER BASED STATCOM G.SUNDAR, S.RAMAREDDY Research Scholar, Bharath University Chenna Professor Jerusalam College of Engg. Chennai ABSTRACT This paper deals with simulation of STATCOM used for harmonic reduction with the aid of multilevel VSI circuit. The harmonics in STATCOM due to the voltage ripple are reduced. As a result, the size of inductor and DC capacitor can be reduced. The STATCOM has the great advantage of a fewer number of devices. The VSI is extremely fast in response to reactive power change. The simulation of the STATCOM is performed in the Simulink environment and the results are presented. Keywords: STATCOM, DC Capacitor, Voltage Ripple I. INTRODUCTION A Flexible AC Transmission System (FACTS) is an AC transmission system incorporating power electronic-based or other static controllers which provide better power flow control and enhanced dynamic stability by control of one or more ac transmission system parameters (voltage, phase angle. and impedance) The STATCOM is traditionally modeled for power flow analysis as a PV or PQ bus depending on its primary application. The active power is either set to zero (neglecting the STATCOM losses) or calculated iteratively. The STATCOM voltage and reactive power compensation are usually related through the magnetic of the STATCOM. This traditional power flow model of the STATCOM neglects the impact of the high frequency effects and the switching characteristics of the power electronics on the active power losses and the reactive power injection (absorption). The STATCOM used to regulate voltage and to improve dynamic stability. There are some variations of the STATCOM. It is composed of inverters with a capacitor in its dc side, coupling transformer, and a control system. The inverters are, in conventional STATCOM s, switched with a single pulse per period and the transformers are connected in order to provide harmonic minimization. The equipment action is made through the continuous and quick control of capacitive or inductive reactive power. Its output voltage is a waveform composed of pulses that approaches a sinusoidal wave. II. STATCOM & ITS OPERATING PRINCIPLE The STATCOM is basically a DC-AC voltage source converter with an energy storage unit, usually a DC capacitor. It operates as a controlled Synchronous Voltage Source (SVS) connected to the line through a coupling transformer. Fig. 1 shows the schematic configuration of STATCOM. The controlled output voltage is maintained in phase with the line voltage, and can be controlled to draw either capacitive or inductive current from the line in a similar manner of a synchronous condenser, but much more rapidly. Fig. 1 Schematic configuration of STATCOM STATCOM has the ability to maintain full capacitive output current at low system voltage, which also improving the transient stability. A Phase-shifted Unipolar SPWM switching scheme is proposed to operate the switches in the system. The scheme which is a slightly modified version of phase-shifted SPWM. The switching frequency of the individual switch is 1 khz. The harmonics of the STATCOM output voltage only appear around 6 khz, 12 khz and so on. 19

Basically, a STATCOM output voltage always contains harmonics, due to the switching behavior of the VSI. These voltage harmonics will generate harmonic currents and further cause power losses in the system network. If the impedance of the lines that connect a STATCOM to the power system is neglected, the harmonic losses are primarily apparent on the connection transformer. The effect of these losses in the transformer can by analyzed by considering an expansion of the transformer impedance. (where X f, X n1, X n2.denote the transformer s inductance under different harmonic frequencies). The harmonic losses on the connection transformer can be expressed as: Fig.2. STATCOM Model for Harmonic losses Fig.2 shows the circuit of a STATCOM connected to a power system by a connection transformer, where V, and e represent the system RMS voltage and the STATCOM s RMS output potential respectively, and RT and 4 denote the resistance and leakage reactance of the connection transformer. Assuming that there are not any harmonics in the system voltage V,, the STATCOM s output voltage e consists of fundamental and high-order harmonics, and may be represented as: Usually, the magnitude of a STATCOM s output voltage relates to the STATCOM s DC side voltage and the conduction mode of h e STATCOM s VSI. For example, if the VSI applies the square wave conduction mode, the output voltage magnitude is a function of the DC side voltage and the firing angles of the VSI. If the PWM mode is used, the output voltage magnitude is a function of the DC side voltage and the duty cycle ratio of the PWM. In the following parts of this paper all derivations will be based on PWM assumption. Therefore using PWM, the output voltage magnitude of the Statcom can be expressed as where K is the duty cycle ratio. Since, e, is directly proportional to the DC side voltage V,, equation (3) can be simplified as Substituting equation (4) into equation (2), the losses caused by the high order harmonics can be expressed as where e f, is the RMS value of the fundamental harmonic, e, represents the RMS values of high-order harmonics, and n 1, n 2 are the harmonic indices. Thus, the first diagram of Fig 2 can be represented as the sum of the other harmonic diagrams Where From equation (6) it can be seen that the high order harmonic losses relate to the STATCOM s 20

operating point and vary with the duty cycle ratio. Typically, when a STATCOM is in steady-state operation, the duty cycle ratio does not change or changes in a very limit range. The STATCOM s output reactive power is regulated through firing angle change. Then R h is treated as a constant. Equation (5) also implies that the high order harmonic losses can be equivalently represented as the active power losses caused by a DC side shunt resistor. (i) Control of Reactive power It is well known that the amount and type (capacitive or inductive) of reactive power exchange between the STATCOM and the system can be adjusted by controlling the magnitude of STATCOM output voltage with respect to that of system voltage. The reactive power supplied by the STATCOM is given by Equation (7) below, Where V STATCOM,, and V, are the magnitudes of STATCOM output voltage and system voltage respectively and X is the equivalent impedance between STATCOM and the system. When Q is positive, the STATCOM supplies reactive power to the system. Otherwise, the STATCOM absorbs reactive power from the system. Since the modulating signals are the same for the inverters in the system, the fundamental component of the STATCOM output voltage is N times of that of each inverter, provided that the voltage across the DC capacitor of each inverter is the same. As a result, the STATCOM output voltage can be controlled by the Modulating Index (Ma). V STATCOM is proportional to m a, as long as the individual inverter is in the linear modulating region. Due to its ability to control the output voltage by the modulating index, the proposed STATCOM has extreme fast dynamic response to system reactive power demand. (ii) Control of DC capacitor voltage If all the components were ideal and the STATCOM output voltage were exactly in phase with the system voltage, there would have been no real power exchange between STATCOM and system therefore the voltages across the DC capacitors would have been able to sustain. However, a slight phase difference between the system voltage and the STATCOM output voltage is always needed to supply a small amount of real power to the STATCOM to compensate the component loss so that the DC capacitor voltages can be maintained. This slight phase difference is achieved by adjusting the phase angle of the sinusoidal modulating signal. If the real power delivered to the STATCOM is more than its total component loss, the DC capacitor voltage will rise, and vice versa. The real power exchange between STATCOM and the system is described by Equation (8) below, where δ is the phase angle difference between STATCOM voltage and the system voltage III. RIPPLE OF DC CAPACITOR VOLTAGES & SIZING OF THE DC CAPACITOR DC capacitors not only play an important role in STATCOM system performance, but comprise a big chunk of the total system cost as well. Hence, proper sizing of the DC capacitors is essential to the low system cost and high performance of the proposed STATCOM. (a) DC Capacitor Voltage Under the assumptions that 1) the harmonic components centered around switching frequency and its multiples are negligible; 2) the DC capacitor voltage ripple is small and 3) system voltage e(t) is sinusoidal, we have in steady state, the following equations. In the above equations, I is the inductor peak current, m a is the Modulating Index (MI), and Φi=90 when the resistor R approaches zero. Equations (3) (5) and (6) result in Equation (11) below 21

(b) Sizing of the DC Capacitors Journal of Theoretical and Applied Information Technology From Equation (8), once the ripple value is specified, the size of DC capacitor can be calculated by equation (9) below. To keep the ripple voltage within the specified value in the full range of reactive power of the STATCOM, m a in Equation (12) should be set to 1. IV. REJECTION OF CURRENT HARMONICS CAUSED BY DC CAPACITOR VOLTAGE RIPPLE We know that the DC capacitor voltage ripple will cause inductor current il to have third order harmonic component. If this harmonic component can be rejected, the size of the inductor L and DC capacitors can be further reduced. A technique to reject harmonic caused by DC voltage ripple, where the DC voltage ripple is independent of the inverter current. Unfortunately, the DC voltage ripple is proportional to the inverter current in the proposed STATCOM. In Equation (4), if the switching function can be expressed by Equation (1 3) below the inductor current will be pure sinusoidal. Equations (3) (6) and (10) will result in Equations (1 4) and (15) below, Instead of m a sinωt, a slightly modified version, i.e., Equation (17), is chosen as the modulating signal. In this case, the inductor current will have no low order harmonic components. Another option to reject the harmonic component is to use equation (10) directly as the modulating signal. Since the DC voltage ripple frequency is much lower compared to the resultant STATCOM switching frequency (2Nf, ), the switching function will approach Equation (l6), if Equation (10) is used as the modulating signal. V. SIMULATION RESULTS Matlab model of two bus system with STATCOM is shown in Fig 3a. Multilevel inverter is represented as a sub system. Three level inverter is represented as a sub system. Three level inverter circuit is shown in Fig 3b. Injected voltage, voltage across loads 1 & 2 are shown in Fig 3c. The frequency spectrum for the injected voltage is shown in Fig 3d. It can be seen that the voltage across loads 1 & 2 reaches normal value due to the voltage injection. Where and As we can see, Equation (8) is the first order approximation of Equation (12). From Equations (10) (12) and (14), we have Equation (1 7). Fig 3a Model of a 2 Bus with STATCOM 22

VI. CONCLUSION Multilevel inverter based STATCOM is modelled and simulated using the blocks of Simulink. This work has proposed a multilevel inverter for the reduction of harmonics in the receiving end voltage. The simulation is based on the assumption of balanced load. Single phase circuit model is considered for simulation studies. Simulation results are presented and they are in line with the predictions. REFERENCES: Fig 3b Three Level Inverter [1] N.G.Hingorani and L.Gyugyi, Understanding FACTS,Concepts and Technology of Flexible AC Transmission Systems, Piscatawat, NJ: IEEE Press. 2000. [2] Yong Hua Song, Allan T.Johns, Flexible AC transmission systems FACTS. IEE Power and Energy Series 30, 1999. [3] R.Mohan and R.K.Varma, Thyristor-Based FACTS Controllers for Electrical Transmission Systems, Pisctaway, NJ: IEEE Press, 2002.. [4] Y.Liang and C.O.Nwankpa, A New type of STATCOM based on cascading voltage-source inverter with phase-shifted unipolar SPWM, IEEE Trans. Ind. Appl., vol 35, no.5 pp. 1118 1123, Sep/Oct. 1999 Fig 3c Voltage across external, load-1 &load-2 waveforms [5] P.Giroux, G.Sybille, and H.Le-Huy, Modeling and simulation of a distribution STATCOM using simulink s power system blockset, in Proc. Annu. Conf. IEEE Industrial Electronics Society 2001, pp. 990 994. [6] R.Mohan and R.K.Varma, Thyristor-Based FACTS Controllers for Electrical Transmission Systems, Pisctaway, NJ: IEEE Press, 2002. [7] F. Z. Peng and J. S. Lai, A multilevel voltagesource inverter with separate DC sources for static var generation, IEEE Trans. Ind. Applicat., vol. 32, pp. 1130 1138, Sept./Oct. 1996. Fig 3d Frequency Spectrum [8] Q.Yu, P.Li, and Wenhua, Overview of STATCOM technologies, in proc. IEEE Int. Conf. IEEE Industrial Electric Utility Deregulation, Restructing, Power Technologies, Hong Kong, Apr. 2004, pp 647-652. 23

[9] Y. Chen et al., Regulating and equalizing DC capacitance voltages in multilevel STATCOM, IEEE Trans. Power Delivery, vol. 12, pp. 901 907, Apr. 1997. BIOGRAPHY: G.Sundar has obtained his B.E degree from Madras University, Chennai in the year 2001. He obtained his ME degree from SCSVMV University, Kanchipuram in the year 2005.He is presently a research scholar at Bharath University, Chennai. He is working in the area Power quality improvement using STATCOM. S.Ramareddy is Professor of Electrical Department Jerusalem Engineering College, Chennai. He obtained his D.E.E from S.M.V.M Polytechnic, Tanuku, A.P. A.M.I.E in Electrical Engg from institution of Engineers (India), M.E in Power System Anna University. He received Ph.D degree in the area of Resonant Converters from College of Engineering, Anna University, Chennai. He has published over 20 Technical papers in National and International Conference proceeding/journals. He has secured A.M.I.E Institution Gold medal for obtaining higher marks. He has secured AIMO best project awards. He has worked in Tata Consulting Engineers, Bangalore and Anna University, Chennai. His research interest is in the area of resonant converter, VLSI and Solid State drives. He is a life member of Institution of Engineers (India), Indian Society for India and Society of Power Engineers. He is a fellow of Institution of Electronics and telecommunication Engineers (India). He has published books on Power Electronics and Solid State circuits. 24