Keysight Technologies Photovoltaic / Solar Array Simulation Solution N8937APV (1500 V, 15 kw, 208 VAC) N8957APV (1500 V, 15 kw, 400 VAC) DG8901A SAS

Similar documents
Photovoltaic / Solar Array Simulation Solution

Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.

Keysight Technologies N8700 Series System DC Power Supplies

Keysight Technologies Migrating Balanced Measurements from the

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies MATLAB Data Analysis Software Packages

Keysight E5063A ENA Vector Network Analyzer

Keysight Technologies N8937APV and N8957APV Photovoltaic Array Simulators N8937APV (15 kw, 208 VAC) N8957APV (15 kw, 400 VAC)

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight Technologies N4985A System Amplifiers

Keysight Technologies How to Easily Create an Arbitrary Waveform Without Programming. Application Note

Keysight Technologies How to Read Your Power Supply s Data Sheet. Application Note

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight Technologies USB Preamplifiers

Keysight Technologies N9310A RF Signal Generator

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Agilent N8700 Series System DC Power Supplies

Keysight N9310A RF Signal Generator

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

Introduction. Part 1. Introduction...2

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies Resistance Measurements Using the B2900A Series of SMUs

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight Quickly Generate Power Transients for Testing Automotive Electronics. Application Note

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight Technologies E4980A Precision LCR Meter

Keysight Technologies VSA Software for Simulation Environments BE/89601 BNE

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight N8803C CAN, LIN, FlexRay, and CAN-FD Protocol Triggering and Decode Software. Data Sheet

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies Overcoming LTE-A RF Test Challenges. Application Note

Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Keysight Technologies Automotive ECU Transient Testing Using Captured Power System Waveforms. Application Note

Keysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300. Application Brief

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies 89601B-SSA/89601BN-SSA Spectrum Analysis VSA Software

Keysight Technologies InfiniiScan Event Identification Software

Keysight Technologies Make Better AC RMS Measurements with Your Digital Multimeter. Application Note

Keysight Technologies How to Take Fast, Simultaneous Measurements of Two or More Signals Using BenchVue Software. Application Note

Keysight M9485A PXIe Multiport Vector Network Analyzer

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Keysight Technologies AC6800B Series Basic AC Power Sources. Data Sheet

Keysight Technologies Wide Range DC Current Biased Inductance Measurement

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight Technologies CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes.

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies Power of Impedance Analyzer

Keysight Technologies N432A Thermistor Power Meter. Data Sheet

Keysight 8762F Coaxial Switch 75 ohm

Keysight Technologies Phase Noise X-Series Measurement Application

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Keysight N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System

Keysight Technologies Improve the Accuracy and Efficiency for Organic-Thin Film Transistor (Organic-TFT) Characterization

Keysight Technologies

Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight N9320B RF Spectrum Analyzer

Keysight Technologies PXI Vector Network Analyzer Series. Drive down the size of test

Keysight Technologies Maximizing the Life Span of Your Relays

Keysight Technologies HMMC GHz High-Gain Amplifier

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Keysight Technologies

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Keysight Technologies VOR and ILS Radio Navigation Receiver Test Using Option 302 for Keysight Signal Sources. Application Note

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Keysight Technologies RS-232/UART Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes. Data Sheet

Keysight Technologies U1210 Series Handheld Clamp Meters

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Transcription:

Keysight Technologies Photovoltaic / Solar Array Simulation Solution N8937APV (1500 V, 15 kw, 208 VAC) N8957APV (1500 V, 15 kw, 400 VAC) DG8901A SAS Control Software with Automated EN50530 Test

02 Keysight Photovoltaic Array Simulation Solution - Brochure Maximize the performance of your inverter maximum power point tracking algorithms and hardware, test to EN50530 standard If you are designing or manufacturing photovoltaic solar inverters up to 1500 V, Keysight s Photovoltaic / Solar Simulation Solution can help you develop, verify, and maximize the per formance of your inverter maximum power point tracking (MPPT) algorithms and circuits as well as quickly and easily test to the European EN50530 (April 2010) standard to easily compare your results to your competitors. N8957APV Photovoltaic Array Simulator The explosive growth in the solar power generation industry has intensified the need for solar inverter test and measurement solutions. To keep solar power at grid parity with competing methods of power generation, performance and power conversion efficiency are increasingly important. Small increments in power production have a dramatic effect on the profitability of solar power generation. You need to ensure your solar inverters are capable of converting the maximum power that is available from the solar array. Developing and verifying the performance of inverter MPPT algorithms and circuits is challenging. MPPT algorithms are complex, and under-the-sun testing with a comprehensive set of temperature and irradiance conditions is extremely difficult, expensive, and time consuming, if even possible at all. As inverter power classes increase in power, the size of the test array would become unmanageable. The only practical test method is to use a laboratory test solution that can simulate real-world conditions. Quickly create, visualize, and execute photovoltaic/solar I-V curves with Keysight s solution Keysight s PV simulation solution consists of the N8900APV Series PV simulators with SAS control/curve generation software. The PV simulators are autoranging, programmable DC power sources that simulate the output characteristics of a photovoltaic array under different environmental conditions (temperature, irradiance, age, cell technology, etc.) enabling you to quickly and comprehensively test inverter MPPT algorithms and inverter efficiency. The SAS Control software is a no-cost way to interface with the N8900APV Series PV simulators. The software allows the user to control the N8900APV s output as well as easily create, visualize, and download solar / photovoltaic I-V curves to the instrument using the Curve Workspace. Once a curve has been downloaded to an N8900APV, the user can enable the output and watch as their PV inverter searches for the maximum power point, gaining insight into their MPPT algorithm. To easily compare your efficiency to your competitors and maximize your appeal to customers, the SAS control software has automated static and dynamic EN50530 MPPT test. Simply input the test parameters, such as Pmp, Vmp, etc., click Start Test and the SAS Control App does the rest. Once the test is complete, SAS Control Pro creates a report formatted to the EN50530 standard as well as a log file with all of the measurements from the test. This feature is free for 30 days. After the 30-day free trial, please purchase DG8901A for a permanent license for EN50530 MPPT test. Maximum Power Point Tracking Maximum Power Point Tracking with varying levels of irradiance

03 Keysight Photovoltaic Array Simulation Solution - Brochure The N8937APV (208-VAC input) and N8957APV (400-VAC input) PV array simulators enable you to develop and verify the performance of inverter maximum power tracking algorithms and efficiency. With 1500-VDC output and 1000-VDC isolation voltage, the PV array simulators are ready for emerging solar power plant technologies and allow testing to higher solar inverter input voltages. You can configure multiple 15-kW instruments in parallel for up to 150 kw of power for testing the largest string inverters at their full rated power. Key features and benefits Easily view and control your N8900APV Series PV Simulator from the Control tab Perform simple functions, such as setting voltage, current and OVP as well as turn the output on/off Set the instrument mode: SAS or Power Supply View the programmed I-V and power curves, maximum power point, and the active I-V and power points (SAS mode only) Figure 3. Parallel the N8937/57APV to test at full power (up to 150 kw) Quickly create and download photovoltaic I-V curves from the Curve Workspace tab Create PV curves according to Sandia, EN50530, and Keysight s proprietary (N8900APV) models Choose between Basic and Advanced curve generation Graphically view the curve before sending it to the instrument Create static and dynamic EN50530 test reports with one click from the MPPT Efficiency tab (DG8901A upgrade required after 30-day free trial) Automated test to the EN50530 standard Automated reports formatted to the EN50530 standard Full log file with all the measurements from the test Use multiple simulation modes to create SAS characteristics The N8937/57APV has two solar array simulation (SAS) operating modes: curve mode where the PV array simulator quickly creates the curve mathematically and table mode where you can enter the precise I-V curve with up to 1024 points. In curve mode, the output I-V characteristic follows an exponential model of the solar array/module. The characteristic is created from four input parameters: I mp the current at the maximum power point I sc the short-circuit current of the array V mp the voltage at the maximum power point V oc the open-circuit voltage of the array In table mode, the SAS characteristic curve is created from up to 1024 user-specified voltage/current points to match specific I-V curves. An intuitive PC-based software application makes creating and downloading SAS characteristic curves fast and straight-forward. You also can operate the N8937/57APV PV array simulators as conventional autoranging single-output supplies, giving you the flexibility to use these supplies throughout your laboratory and production facilities. Refer to the following pages for details.

04 Keysight Photovoltaic Array Simulation Solution - Brochure Your PV Array Simulator is Also an Autoranging System DC Power Supply The Keysight Technologies N8937/57APV PV array simulator provides 15 kw autoranging, single-output programmable DC power for ATE applications that require just the right amount of performance at just the right price. The autoranging output characteristic enables unprecedented flexibility by offering a wide range of voltage and current combinations at full power. Power supplies with rectangular, or traditional, output characteristics provide full power at only one voltage and current combination. Just one does the job of multiple power supplies. It s like having many power supplies in one! The N8937/57APV PV array simulator Series provides stable output power, built-in voltage and current measurements, and autoranging output voltage and current from up to 1500V and up to 30 A. These supplies offer many system-ready features like multiple standard I/O interfaces to simplify and accelerate test-system development and compact 3U design to save rack space. If you need more power, you can easily parallel multiple units to create one power supply with up to 90 kw of total output power. The built-in master/slave control enables programming as if it s just one big power supply; no need to program each supply individually. Autoranging output does the job of multiple power supplies The N8937/57APV PV array simulators autoranging output characteristic makes it much more flexible than rectangular, or traditional, output characteristic power supplies because they expand the power curve, giving you more voltage and current combinations in one power supply. It s like having many rectangular power supplies in one. For example, the 1500 V, 30 A, 15 kw model is capable of 1500 V and 10 A at 15 kw as well as 500 V and 30 A at 15 kw. If it were a rectangular output, the specifications will be 1500 V, 10 A, 15 kw. At 500 V it would only be able to output 5 kw, not the 15 kw of autoranging output. Figures 4 and 5 show a graphical representation of this example. Just the right amount of performance at just the right price 15 kw maximum output power Up to 1500 V and up to 30 A Available with 208- and 400-VAC input Easily parallel units to create one power supply with up to 150 kw of power Built-in voltage and current measurement High power density, 15 kw in only 3U (5.25 inch/13.34 cm) Protection from over-voltage, over-current, and over-temperature LAN (LXI Core), USB, GPIB, and analog interfaces all standard 1500 V 500 V 15 kw power curve Autoranging output like having many power supplies in one 10 A 30 A Figure 4. Autoranging output characteristic 1500 V Rectangular (traditional) output characteristic 15 kw 500 V 3.3 kw 10 A Figure 5. Rectangular output characteristic

05 Keysight Photovoltaic Array Simulation Solution - Brochure Easy front-panel operation Using the front panel controls, you have complete access to all of the N8937/57APV PV array simulator features via the extensive menu system (Note: SAS table points cannot be programmed from the front panel). You can either use the voltage and current knobs or enter your settings via the keypad. You can also set protection settings, power-on states, and other features. The output voltage, current, and power can be displayed simultaneously, and annunciators at the bottom of the display show PV array simulator status and operating modes. You can lock the front panel controls to protect against accidental parameter changes. Device protection To safeguard your device, the N8937/57APV PV array simulator provides over-temperature, over-current and over-voltage protection to shut down the power supply output when a fault condition occurs. Simple system connections The N8937/57APV PV array simulator comes standard with GPIB, Ethernet/LAN, USB 2.0, and analog interfaces giving you the flexibility to use your I/O interface of choice today and safeguard your test setup for the future. There is no need to worry whether or not you are choosing the right interface when they all come standard. The PV array simulators are fully compliant with the LXI Core specification. Remote access and control The built-in Web server provides remote access and control of the instrument via a standard browser. This control goes above and beyond the LXI specification, giving you the ability to monitor and control the instrument from anywhere. Using the Web browser, you can set up, monitor and operate the instrument remotely. Figure 6. Web graphical user interface for remote access and control of the instrument. Easy system integration and configuration To simplify system development, the PV array simulators come standard with IVI-COM drivers. The PV array simulators support easy-to-use SCPI (Standard Commands for Programmable Instruments) commands. Need more power? We ve got you covered. Quickly create a master/slave setup for even more total output power. The PV array simulators give you the flexibility to easily connect in parallel up to ten identical units for greater output current and power. The units can also be configured to look like one big power supply. (See Figure 7, page 6.) Series operation is not recommended.

06 Keysight Photovoltaic Array Simulation Solution - Brochure Analog programming and monitoring The output voltage and current can be programmed from zero to full-scale by an analog voltage signal from 0 to 5 V or 0 to 10 V, each corresponding to 0 to 100% of full-scale. The measured output voltage and current can also be monitored in the same way. AC input Choose either the N8937APV for 208-VAC input or the N8957APV for 400-VAC input. This gives the PV array simulator the ability to be used anywhere in the world. Choose 208 VAC for regions such as the Americas and Japan or choose 400 VAC for regions such as Europe and Asia. Performance specifications All specifications pertain to > 2% of rated voltage and > 1% of rated current DC output ratings Power Output voltage ripple and noise CV p-p 1 CV rms 2 Load effect (change from 0% to 100% of full load) Programming accuracy (23 C ± 5 C) Measurement accuracy (23 C ± 5 C) N8937APV / N8957APV 1500 V 30 A 15 kw 2400 mv 400 mv 750 mv 53 ma / 45 ma 1.5 V 60 ma 1.5 V 60 ma Load transient recovery time (time for output voltage to recover within 1% of its rated output for a load change from 10% to 90% of its rated output current) Time 1.5 ms Figure 7. Parallel operation for more power (cables not included) 1. 20 Hz to 20 MHz 2. 20 Hz to 300 khz

07 Keysight Photovoltaic Array Simulation Solution - Brochure Supplemental characteristics (typical) N8937APV / N8957APV Output response time: Time from 10% to 90%, or 90% to 10%, of total voltage excursion Up, full load 1 Down, full load 1 Down, no load Command response time Remote sense compensation Volts/load lead Over-voltage protection Range Source effect (± 10% of AC input rating) Output current ripple and noise CC rms Programming resolution Measurement resolution Output terminal isolation Positive terminal Negative terminal Acoustic noise declaration Idle fan speed Max fan speed N8937APV (208-VAC input) Nominal input voltage 30 ms 80 ms 10 s < 25 ms 1. For purposes of output response time, full load occurs at the full range output voltage and the maximum output current available at the full output voltage. 30 V 0-1650 V 300 mv 15 ma 26 ma 61 mv 2 ma 61 mv 2 ma + 1500 V ± 1000 V 56 dba / 52 dba 79 dba / 73 dba 208 VAC Input range Nominal ± 10% Frequency Phase Input current Inrush current 45-65 Hz 3 phase 3 x 56 A 97 A Efficiency 91% N8957APV (400-VAC input) Nominal input voltage 400 VAC Input range Nominal ± 10% Frequency Phase Input current Inrush current 45-65 Hz 3 phase 3 x 28 A 49A Power factor > 0.99 Efficiency 93%

08 Keysight Photovoltaic Array Simulation Solution - Brochure Supplemental characteristics (typical) - all models Supplemental characteristics Analog programming Input range Accuracy Input impedance Referenced to: Temperature coefficients: (after 30 minute warmup) Selectable: 0 to 5 V or 0 to 10 V Specified accuracy + 0.2% of rating 150 kω Ground 50 PPM/ C of rated output voltage 50 PPM/ C of rated output current Series operation not recommended Parallel operation Master-slave Savable states Nonvolatile memory Interface capabilities GPIB, USB 2.0, 10/100 LAN LXI compliance Environmental conditions Yes 10 memory locations SCPI - 1993, IEEE 488.2 - compliant interface LXI Core 2011 compliant Environment Indoor use, installation category II (AC input), pollution degree 2 Operating temp 0 C to 45 C Storage temp 20 C to 70 C Operating humidity 80% Storage humidity 80% Altitude Built-in Web server 2000 m Requires Internet Explorer 7+, or Firefox. Additionally requires Java plug-in and the Java Runtime Environment. Regulatory compliance EMC Complies with European EMC Directive for test and measurement products Complies with Australian standard and carries C-Tick mark Complies with Canadian ICES-001 Safety Complies with European Low Directive and carries the CE-marking Complies with US and Canadian safety regulations Not applicable for IT mains supply systems Declarations of Conformity for this product may be downloaded from the web. Go to www.keysight.com/go/conformity and enter model number of your unit in the search field.

09 Keysight Photovoltaic Array Simulation Solution - Brochure Outline diagrams 449 mm 40 mm 610 mm (400 VAC units) 660 mm (208 VAC units) 64 mm Product weight N8937APV (208-VAC) N8957APV (400-VAC) 35.2 kg (77.4 lbs) 31.8 kg (70 lbs) 483 mm 133 mm 135 mm w/feet = airflow DC output bus-bar detail Ø 6.5 mm 10 mm 20 mm 10 mm 20 mm

10 Keysight Photovoltaic Array Simulation Solution - Brochure Available N8900APV models Model # Max voltage (V) (A) @ max voltage1 (V) @ max current1 Max current (A) Max power (W) AC input voltage (VAC) N8937APV 1500 10.0 500.0 30 15000 208 N8957APV 1500 10.0 500.0 30 15000 400 Figure 8. N8937APV System DC Power Supply with PV Mode SAS Control Software Product/Model # Description SAS Control Software Available for download at www.keysight.com/find/sascontrolsoftware DG8901A License for SAS Control Pro, enables automated static and dynamic EN50530 test. Figure 9. SAS Control Software performing dynamic EN50530 MPPT test 1. The N8937/57APV PV array simulators can be used as autoranging power supplies. The @ max voltage and @ max current are listed to show the full range of voltage and current combinations possible due to the autoranging capability.

11 Keysight Photovoltaic Array Simulation Solution - Brochure Options None AC input voltages If the AC input voltage where the instrument will be used is: 208, 220, 230, or 240 VAC, ± 10%, please choose the N8937APV 400 VAC ± 10%, please choose the N8957APV Accessories You can install N8937APV and N8957APV into the optional N8900 Series Rack System, which is designed for high-powered applications. N89202A: 208-VAC input N89402A: 400-VAC input Choose up to six N8937/57APV supplies supplies to meet the power requirements for your application. Line cords and terminations (plugs) Due to the number of different line cords and regulations around the world, the N8937/57APV PV array simulators do not include line cords or terminations. You will need to supply your own dependent on the local laws and codes of the country/region where you will use the PV array simulator.

12 Keysight Photovoltaic Array Simulation Solution - Brochure Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. http://www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument s lifecycle. Our comprehensive service offerings onestop calibration, repair, asset management, technology refresh, consulting, training and more helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/n8937apv www.keysight.com/find/n8957apv Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. Keysight Technologies, 2017 Published in USA, Decemer 1, 2017 5992-0999EN www.keysight.com