Solutions for Solar Cell and Module Testing

Similar documents
UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Process Control Calibration Made Easy with Agilent U1401A

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes

Agilent E4438C/E8267D Option 422 Scenario Generator for GPS

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent NFA Noise Figure Analyzer

I-V Curve Characterization in High-Power Solar Cells and Modules

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms

Solar Array Simulation System Integration

Agilent MXG Signal Generators

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

Agilent 87075C Multiport Test Set

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

Multipurpose Lab Station by Agilent Technologies

Agilent MXG Signal Generators

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz


Creating Arbitrary Waveforms in the U2300A Series and U2500A Series Data Acquisition Devices

Agilent U1240 Series Handheld Digital Multimeters

Agilent J7211A/B/C Attenuation Control Units

Techniques to Achieve Oscilloscope Bandwidths of Greater Than 16 GHz

Agilent Migration from the Agilent 34401A to the Agilent 34405A Digital Multimeter. Application Note

Evaluating Oscilloscope Bandwidths for your Application

Agilent U1700 Series Handheld LCR Meters

Agilent U9397A/C FET Solid State Switches (SPDT)

Agilent 8761A/B Microwave Switches

Agilent 8762F Coaxial Switch 75 ohm

Advanced Measurement Techniques for RF Amplifiers Using Unique Functions of the Agilent E5071C ENA. Application Note

EM Insights Series. Episode #1: QFN Package. Agilent EEsof EDA September 2008

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

MIL-STD 1553 Triggering and Hardwarebased Decode (Option 553) for Agilent s InfiniiVision Series Oscilloscopes

Multiport Solutions for E5071C ENA RF Network Analyzers Using External Switches. Application Note

Agilent N9310A RF Signal Generator. All the capability and reliability of an Agilent instrument you need at a price you ve always wanted

Agilent EEsof EDA.

Educator s Oscilloscope Training Kit for the InfiniiVision 2000 & 3000 X-Series

Making a S11 and S21 Measurement Using the Agilent N9340A

Agilent InfiniiMax III probing system

Agilent NFA Noise Figure Analyzer

Agilent N8700 Series System DC Power Supplies

Agilent 81150A Pulse Function Arbitrary Noise Generator Applications

When is it Time to Transition to a Higher Bandwidth Oscilloscope?

Agilent HMMC-3124 DC-12 GHz Packaged High Efficiency Divide-by-4 Prescaler 1GC TR1-7" diameter reel/500 each 1GC BLK-bubble strip/10 each

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent U2000 Series USB Power Sensors. Data Sheet

N9051A Pulse Measurement Software

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

Agilent 4287A RF LCR Meter 1 MHz - 3 GHz. Technical Overview

Agilent 2-Port and 4-Port PNA-X Network Analyzer

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Keysight Technologies

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Keysight Technologies

Agilent 81180A Arbitrary Waveform Generator

IEEE Standard Boundary Scan Testing on Agilent Medalist i3070 In Circuit Systems

Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters

Agilent N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System

Agilent Technologies Noise Figure Selection Guide

Flexible Signal Conditioning with the Help of the Agilent 81134A Pulse Pattern Generator

Agilent 86142B and 86146B Optical Spectrum Analyzers

Agilent E4428C and E4438C ESG Signal Generators

MXG X-Series Signal Generator N5183B Microwave Analog

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Agilent U2741A USB Modular 5.5 Digits Digital Multimeter. Data Sheet

Comparing Contact Performance on PCBA using Conventional Testpads and Bead Probes

Keysight Technologies Making Current-Voltage Measurement Using SMU

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent MIMO Manufacturing Solution. Application Note

Simplifying DC-DC Converter Characterization using a 2600B System SourceMeter SMU Instrument and MSO/DPO5000 or DPO7000 Series Scope APPLICATION NOTE


N2820A/21A High-Sensitivity, High Dynamic Range Current Probes

Agilent U1730C Series Handheld LCR Meters

Agilent NFA Noise Figure Analyzer

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Agilent N8262A P-Series Modular Power Meter and Power Sensors. Data Sheet

Keysight Technologies Resistance Measurements Using the B2900A Series of SMUs

Agilent 84904, 6, 7K/L Programmable Step Attenuators

Advanced Test Equipment Rentals ATEC (2832)

Essential Capabilities of EMI Receivers. Application Note

Agilent E7400A Series EMC Analyzers

Agilent N4916B De-emphasis Signal Converter

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Agilent Digital Modulation Lab Station

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Radar System Design and Interference Analysis Using Agilent SystemVue

Transcription:

Solutions for Solar Cell and Module Testing Agilent 663XB Power Supplies Connected in Anti-Series to Achieve Four-Quadrant Operation for Solar Cell and Module Testing Application Note Overview To fully characterize the performance of a solar cell or module with a power supply, you need to apply voltage in forward and reverse polarities. When the solar device is illuminated, the power supply acts as a variable voltage load and you can measure the power I-V curve. When the solar device is dark, voltage is applied in both forward and reverse directions and you can measure the entire dark I-V curve. Complete characterization of a solar device generally requires a four-quadrant-capable power source. Measuring the I-V performance of an illuminated solar device requires the power supply to sink current while sourcing positive voltage. Measuring the I-V performance of a dark cell requires the power supply to source positive and negative voltage and current to cover the full range of solar device operation. A bipolar power supply is generally the instrument of choice. When a bipolar source is not available, a pair of two-quadrant power supplies can be a viable alternative if you configure them appropriately.

Problem Obtaining an uninterrupted test voltage that is adjustable over a range that encompasses positive and negative voltage and current values without a bipolar power supply can be a challenge. The use of a single- or two-quadrant power supply with a polarity reversing relay or switch matrix creates a discontinuity at or near zero volts that may not be acceptable. Solution Obtaining an uninterrupted voltage ranging from beyond a cell or module s open circuit voltage to full reverse polarity can be achieved with a pair of two-quadrant power supplies connected in anti-series. The negative terminals of the supplies are connected together and the positive terminals of both are connected to the solar device under test. Figure 1 depicts two Agilent 6631B power supplies in an arrangement for testing the performance of a solar cell. The positive terminal of power supply 1 is connected to the positive terminal of the solar cell. The positive terminal of power supply 2 is connected to the negative terminal of the solar cell. Each power supply must be capable of sourcing and sinking its full rated current. When you connect them in an anti-series configuration, the combination offers operation in four quadrants. When power supply 1 sources current, power supply 2 will sink current. Conversely, when power supply 2 sources current, power supply 1 will sink current. The current-sinking capability of each power supply must be equal to or greater than the sourcing capability of the other to obtain the full rated operating range. With the solar cell illuminated, power supply 1 is programmed from zero volts to Voc, and it will sink current generated by the solar cell. Power supply 2 is programmed to and held at zero volts. When the device is dark and the total voltage on the cell is greater than zero, power supply 1 will source current and power supply 2 will sink current. When the device is dark and the total voltage on the cell is less than zero, power supply 2 will source current and power supply 1 will sink current. 6631B power supply 1 +s + - -s - - -S -S +s + -s - 6631B power supply 2 To ensure that the voltage applied to the solar cell is accurate, you must connect the sense leads appropriately. Connect the positive sense leads of each power supply to the solar cell where you plan to measure the voltage. Connect the negative sense leads to a common location, either on the lead that couples the negative outputs or on the negative terminal of one of the supplies. Figure 1 shows the negative sense leads attached to a point midway on the lead that connects the negative terminals of both supplies. Using remote sensing eliminates the voltage drops on the lead wires and greatly improves your accuracy. Solar cell + - +S + + +S Figure 1: Two 6631B two-quadrant power supplies connected in anti-series 2

Process An example test sequence is outlined below. Test steps are executed in one continuous sequence to obtain: 1. Illuminated I-V curve 2. Dark I-V curve (forward bias region) 3. Dark I-V curve (reverse bias region) Current Isc Solar cell Illuminated Power I-V curve Dark Dark I-V curve Program power supply 1 and 2 voltages to obtain the required solar cell voltages in forward and reverse polarities. To measure the I-V curve of a solar cell when it is illuminated, incrementally increase the voltage of power supply 1 to Voc. To measure the dark I-V curve, use power supply 1 at Voc and incrementally increase the voltage of power supply 2 to offset the voltage of power supply 1 until you reach the required reverse bias level. Voltage Voltage Voltage Solar cell Cell voltage is power supply 1 minus power supply 2 voltage Power supply 1 Power supply 2 Voc Max. reverse polarity = power supply 2minus power supply 1 voltage Cell voltage transition through zero Voc (or higher) Required max reverse cell voltage plus power supply 1 voltage Time Figure 2. Solar cell voltage and current and the voltages of power supplies 1 and 2 plotted against time 3

Technical Specifications Test step 1: Illuminated cell I-V curve measurement (power quadrant) Solar device and power supply status Solar device sources current Power supply 1 sinks current Power supply 2 sources current (output maintained at zero volts) Setup: A. Program power supply 1 to V and program current limit to beyond Isc B. Program power supply 2 to zero volts and program its current limit to beyond Isc Procedure: 1. Illuminate the solar device 2. Program power supply 1 to increase its voltage from zero to Voc in small increments and remain at Voc after illumination is extinguished. 3. Keep power supply 2 programmed to V Isc Current (A) Test step 2: Dark I-V curve measurement (forward bias region) Solar device and power supply status Current flows into the positive terminal of the solar cell Power supply 1 sources current Power supply 2 sinks current Setup: A. Power supply 1 voltage level begins at Voc Procedure: 1) Program power supply 2 to increase its voltage in small increments to offset the voltage of Power Supply 1 until the net voltage across the solar cell is zero. Voltage (V) Figure 4: Dark I-V curve measurement (forward bias region) Current (A) Test step 3: Dark I-V curve measurement (reverse bias region) Solar device and power supply status Current flows into the negative terminal of the solar cell Power supply 1 sinks current Power supply 2 sources current Procedure: (continuation from test step 2) 2) The test continues with the increase of the voltage of power supply 2 in small increments to obtain the desired net negative voltage that reverse biases the solar cell. 3) When the reverse bias test is completed, both power supplies are programmed to zero volts. Voltage (V) Figure 5. Dark I-V curve measurement (reverse bias region) Current (A) Voltage (V) Figure 3: Illuminated cell I-V curve measurement (power quadrant) Voc 4

Alternative Test Sequences Other test voltage sequences are possible. For example, if you want to perform both illuminated and dark cell tests, an alternative approach for test step 2 is to program the voltage of power supply 1 to decrease gradually to zero after you have completed test step 1. With the cell in darkness, you can obtain the I-V characteristic in the forward region, as depicted in test step 2. When power supply 1 voltage reaches zero, you can increase power supply 2 voltage to reverse bias the cell to obtain the I-V characteristic depicted in test step 3. Conclusion Successfully configuring power supplies in anti-series for testing illuminated and dark solar cells requires that each supply is capable of sinking the current that will be sourced by the other. Power supply 1 in the configuration must be capable of sinking, and power supply 2 must be capable of sourcing, the current produced by the solar cell under illumination. Using either approach to solar cell testing will result in a transition from forward to reverse bias through zero volts without the delay and associated circuit interruption associated with polarity reversal relays and switches. If it is absolutely necessary to avoid all discontinuities as the cell is reverse biased, it is important to note that the second approach may introduce a small discontinuity near zero volts due to programming offsets. Related Agilent Literature Publication Type Pub number 6631B, 32B, 33B & 34B Power Supplies Catalog pages 5989-8959EN Solar Cell and Module Testing Application Note 599-3263EN 5

www.agilent.com Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. For information regarding self maintenance of this product, please contact your Agilent office. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt Product specifications and descriptions in this document subject to change without notice. For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894-4414 Latin America 35 269 75 United States (8) 829-4444 Asia Pacific Australia 1 8 629 485 China 8 81 189 Hong Kong 8 938 693 India 1 8 112 929 Japan 12 (421) 345 Korea 8 769 8 Malaysia 1 8 888 848 Singapore 1 8 375 81 Taiwan 8 47 866 Thailand 1 8 226 8 Europe & Middle East Austria 1 3627 71571 Belgium 32 () 2 44 93 4 Denmark 45 7 13 15 15 Finland 358 () 1 855 21 France 825 1 7* *.125 /minute Germany 731 464 6333 Ireland 189 924 24 Israel 972-3-9288-54/544 Italy 39 2 92 6 8484 Netherlands 31 () 2 547 2111 Spain 34 (91) 631 33 Sweden 2-88 22 55 Switzerland 8 8 53 53 United Kingdom 44 () 118 927621 Other European Countries: www.agilent.com/find/contactus Revised: March 24, 29 Agilent Technologies, Inc. 29 Printed in USA, July 29, 29 599-3949EN