Data Sheet RN Thyristor Controllers RN Thyristor Controllers Thyristor Controllers (solid state relays) provide a means of varying the voltage for electrically resistive s, typically electric heating elements.they are not suitable for switching motors or for heater lamp applications. Trend RNFV RNFV RNF4V RNF4V RNF4V RNF4V Thyristors All Trend RN solid state thyristor relays have the following specification: Control input :0 to 0 Vdc, 0. ma at 0 Vdc Control supply : to Vdc or to 7 Vac; ma at Vdc or 7 Vac Current ratings :depend on ambient temperature, nominal, A ratings are at C ambient. Voltage ratings V :5 to 5 Vac 40 V :90 to 5 Vac Document Attached: Carlo Gavazzi RN F data sheet (/5/00) Description Housing pole Vac A thyristor RHN pole Vac A thyristor RHN pole 40 Vac A thyristor RHN pole 40 Vac A thyristor RHN pole 40 Vac A (5 A per pole) thyristor RHN pole 40 Vac A (5 A per pole) thyristor RHN Applications: wire phase to phase or phase to neutral NEUTRAL (resistive) Vac 7. 7. RNFV RNFV RNF4V RNF4V wire phase floating star (all s resistive). RNF4V RNF4V 4 wire phase with star point to neutral (all s resistive) NEUTRAL. RNF4V RNF4V RN Thyristor Controllers Data Sheet TA0097 Issue /C 5//0
RN Data Sheet Applications (continued) 4 wire phase closed delta. RNF4V RNF4V (all s resistive) 5 wire phase open delta 7.. RNF4V 4 RNF4V (all s resistive) wire phase star phases controlled (burst fire only) (all s resistive). 0. RNF4V RNF4V RNF4V 5 RNF4V 5 7 wire phase delta phases controlled (burst fire only) (all s resistive). 0. RNF4V RNF4V RNF4V 5 RNF4V 5 Trend Control Systems Ltd reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions or changes. Trend Control Systems Ltd P.O. Box 4 Horsham Sussex RH YF England Tel:44 (0)40 Fax:44 (0)40 40 www.trend-controls.com RN Thyristor Controllers Data Sheet TA0097 Issue /C 5//0
Solid State Relays Analog Full Cycle Switching RN.F... AC solid state relay, - and poles Analog switching for resistive s (heating) 4-0 ma or 0-0 V controls Rated operational current and AAC rms Rated operational voltage up to 40 VAC LED-indication for normal operation and alarm status IP 0 protection DIN-rail mountable Product Description Ordering Key RN F 40 V The analog switching relay provides a number of full cycles, evenly distributed over a fixed period, depending of the control input. The input of 4-0 ma or 0-0 VDC respectively, corresponds to zero and full output within a period of. s @ Hz (.07 s @ 0 Hz). This principle makes the transfer characteristics fully linear. The principle operates with zero switching, thus ensuring a reduced level of radiated and wire conducted noise. The - pole type has alarm LED indication by loss of master phase. The analogue Full Cycle Switching is not recommended for light control due to light-flickering. Solid State Relay Number of poles Switching type Rated operational voltage Control signal Rated operational current Selection, -Pole Rated Control Control Rated operational current operational voltage input supply A A 0 VAC 4-0 ma 7-0 VDC RN FI RN FI 0-0 VDC - VDC, 4 VAC RN FV RN FV VAC 4-0 ma 7-0 VDC RN FI RN FI 0-0 VDC - VDC, 4 VAC RN FV RN FV 40 VAC 4-0 ma 7-0 VDC RN F4I RN F4I 0-0 VDC - VDC, 4 VAC RN F4V RN F4V Selection, -Pole Rated Control Control Rated operational current operational voltage input supply A A 0 VAC 4-0 ma 7-0 VDC RN FI RN FI 0-0 VDC - VDC, 4 VAC RN FV RN FV VAC 4-0 ma 7-0 VDC RN FI RN FI 0-0 VDC - VDC, 4 VAC RN FV RN FV 40 VAC 4-0 ma 7-0 VDC RN F4I RN F4I 0-0 VDC - VDC, 4 VAC RN F4V RN F4V Specifications are subject to change without notice (.05.00)
RN F General Specifications Thermal Specifications RN.F... RN.F... RN.F4... Operational voltage range 5 to 40 VAC 5 to 5 VAC 90 to 5 VAC Non-rep. peak voltage 00 V p 00 V p 000 V p Varistor voltage 75 VAC 75 VAC 50 VAC Zero voltage turn-on < 0 V < 0 V < 0 V Operational frequency range 45 to 5 Hz 45 to 5 Hz 45 to 5 Hz Power factor at rated voltage 0.9 0.9 0.9 Average output power 0 to 00% 0 to 00% 0 to 00% Output power resolution /4 of 00% /4 of 00% /4 of 00% Approvals UL, cul, CSA UL, cul, CSA UL, cul, CSA CE-marking Yes Yes Yes Norms fulfilled HD 49.S Low-voltage controlgear semiconductor contactors EN 0- Generic Immunity Standard. Residential, Commercial & Light Industry Environment EN 0- Generic Immunity Standard. Industrial Environment Input Specifications Current controlled input Control current range Allowable input current Reverse polarity protected Voltage drop Output Specifications RN.F..I.. 4-0 ma ma Yes 0 VDC @ 0 ma Voltage controlled input Supply voltage range Supply current Control voltage range Control input current RN.F..V.. RN.F.. RN.F.. Rated operational current RNF.. AC5 @Ta= C A A @Ta=40 C A A @Ta= C A A @Ta=0 C 0 A A RNF.. AC5 @Ta= C A total sum A total sum @Ta=40 C A total sum A total sum @Ta= C A total sum A total sum @Ta=0 C 0 A total sum A total sum Zero crossing detection Yes Yes Min. operational current (per pole) 0 ma 0 ma Rep. over current t= s (Tj init.=5 C) 55 A (rms) 5 A (rms) Non-rep. surge current t=0 ms (Tj init.=5 C) < A p < 00 A p Off-state leakage current, @ rated voltage and frequency (Tj.=5 C, max.) < ma < ma I t for fusing t= to 0 ms 0 A s 00 A s Critical dv/dt off-state 0 V/µs 0 V/µs - 7 VAC, - VDC ma @ 4 VAC/ VDC 0-0 V 0. ma @ 0 VDC RN.F.. RN.F.. Operational temperature -0 to 70 C (-4 to 5 F) -0 to 70 C (-4 to 5 F) Storage temperature -0 to 00 C (-4 to F) -0 to 00 C (-4 to F) Junction temperature < 5 C (57 F) < 5 C (57 F) R th junction to ambient (AC ). K/W.7 K/W Specifications are subject to change without notice (.05.00)
RN F Housing Specifications Mounting DIN-rail 5 mm Weight with RHN 470 g Weight with RHN 70 g Housing material Glass reinforced noryl SEGFN LED window material PC Lexan 4R Base plate Aluminium, nickel plated Potting compound Polyurethane, Casco Nobel Terminals Screw with captive wire clamp Control terminals nominal 4 mm or x.5 mm AWG or x AWG 4 Min. 0.5 mm, AWG 0 Mounting torque max. 0. Nm Power terminals nominal 0 mm or x mm AWG or x AWG 0 Min. mm, AWG Mounting torque max..0 Nm Heatsink compound used Dow Corning 40 Insulation Rated impulse withstand voltage Input to output 4000 V imp Rated impulse withstand voltage Output to heatsink 4000 V imp Environment Specifications Humidity max. Dimensions 95%, no condensation Dimensions with RHN ( A) (H x W x D) 0 x 45 x 0 mm Dimensions with RHN ( A) (H x W x D) 0 x 90 x 0 mm Dimensions 0 9 0 4 0 0 0 70 4 0 45 7 7, 45 7 7, 9 0 0 70 RHN,7 Note: all dimensions in mm RHN 7 Note: all dimensions in mm Wiring Diagrams Current Control 4-0 ma Voltage Control 0-0 VDC Current Control 4-0 ma Voltage Control 0-0 VDC L A A L A A L L A A L L A A T T A A 4 T T T T A A 4 Single-pole relay Control Supply Double-pole relay Control Supply Specifications are subject to change without notice (.05.00)
RN F Terminal Layout -pole RN.. -pole RN.. Functional Diagrams -pole current controlled input A L A A L L A Master VAC/VDC / VDC(A, A 4 only used for voltage control) A A 4 L A control signal A C/V T Slave (-pole version) L A A 4 T A 4 T T A Shown with RHN T Applications Single and double pole relay application Line-Neutral Double pole relay in -phase application Star and delta application (Economy Switching only) L L L L L N 4 Specifications are subject to change without notice (.05.00)