GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

Similar documents
GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

PART 1 OWNER/APPLICANT INFORMATION

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

APPLICATION FOR INTERCONNECTION & OPERATIONS OF MEMBER-OWNED GENERATION

APPENDIX B: Generation Interconnection Application Form

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

Connection Impact Assessment Application

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

Impact Assessment Generator Form

Form B. Connection Impact Assessment Application Form Distribution System

Distributed Generation Application Form (Generation of Greater than 20 kw to 15 MW)

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application

OPERATING, METERING, AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 2,000 KILOWATTS

Connection Impact Assessment Application Form

Embedded Generation Connection Application Form

Initial Application Form for Connection of Distributed Generation (>10kW)

TABLE OF CONTENT

Embedded Generation Connection Application Form

Embedded Generation Connection Application Form

Generation Interconnection Study Data Sheet Synchronous Machines

Sizing Generators for Leading Power Factor

Spec Information. Reactances Per Unit Ohms

Generator Advanced Concepts

GENERATOR DATA JANUARY 30, 2015

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

TRANSFORMER OPERATION

SYNCHRONOUS MACHINES

STEADY STATE REACTANCE

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

BE Semester- VI (Electrical Engineering) Question Bank (E 605 ELECTRICAL POWER SYSTEM - II) Y - Y transformer : 300 MVA, 33Y / 220Y kv, X = 15 %

AGN 034 Alternator Reactance

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

Experiment 45. Three-Phase Circuits. G 1. a. Using your Power Supply and AC Voltmeter connect the circuit shown OBJECTIVE

Course ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation

Spec Information. Reactances Per Unit Ohms

Type KLF Generator Field Protection-Loss of Field Relay

QUESTIONNAIRE for Wind Farm Power Stations only

Electrical Workstation Nvis 7089A

Regional Technical Seminar TAP CHANGERS

440 (12) 416 (12) 416 (12) 440 (12)

WDG 13 - Technical Data Sheet

S4L1D-G41 Wdg Technical Data Sheet

S4L1S-D4 Wdg.17 - Technical Data Sheet

Apprentice Electrical Technician Test (ETT) Preparation Guide

WIND TURBINE CONNECTED TO THE ELECTRICAL NETWORK

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

S0L1-J1 - Technical Data Sheet

WDG 83 - Technical Data Sheet

+ 24V 3.3K - 1.5M. figure 01

Level 6 Graduate Diploma in Engineering Electrical Energy Systems

Electrical Workstation Nvis 7089B

Appendix C-1. Protection Requirements & Guidelines Non-Utility Generator Connection to Okanogan PUD

PI734C - Technical Data Sheet

Power Factor & Harmonics

Wind Power Facility Technical Requirements CHANGE HISTORY

PI734A - Technical Data Sheet

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

WDG 12 - Technical Data Sheet

Conventional Paper-II-2013

Modelling Parameters. Affect on DER Impact Study Results

PM734B - Technical Data Sheet. Generator Solutions AS

WDG 71 - Technical Data Sheet

System Protection and Control Subcommittee

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

WDG 12 - Technical Data Sheet

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

WDG 61 - Technical Data Sheet

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

WDG 51 - Technical Data Sheet

AC Power Instructor Notes

WDG 07 - Technical Data Sheet

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

SECTION 1 INTRODUCTION

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

Code No: R Set No. 1

PAPER-II (Subjective)

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Component Requirement Specification for SGI 500XT Isolation Transformer

Transcription:

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW Electric Utility Contact Information DTE Energy Interconnection Coordinator One Energy Plaza, SB 490 Detroit, MI 48226 Interconnection Hotline: 313.235.4333 Interconnection Email: interconnect@dteenergy.com For Office Use Only Application No. Date & Time Application Received Electric Utility Customer Information: ( As shown on utility bill ) Required Information for all Projects Types Customer Name ( Last, First, Middle): Customer Mailing Address: Customer Phone # Customer E-Mail Address: ( optional ) Project Developer/Single Point of Contact Name: Address: Phone Number: Fax Number: E-Mail Address: Project Site Address: Generation System Information Project Type (Base load, peaking, intermediate) Energization Date for Project Interconnection Facilities First Parallel Operation Date for Testing Project Commercial Operation Date Estimated Project Cost Operation Mode Isolating Transformer(s) between Generator(s) and Utility Transformer Model Number: Transformer Manufacturer: Rated kv and connection (delta, wye, wye-gnd) of each winding kva of each winding BIL of each winding Fixed taps available for each winding Positive/Negative range for any LTC windings %Z impedance on transformer self cooled rating Percent Excitation current at rated kv Load Loss Watts at full load or X/R ratio

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW Required Information for all Projects Types 1. Customer's Proof of General Liability Insurance for a minimum of $1,000,000 Page # (Per MPSC Order in Case No. U-15787 - Customer must maintain a minimum of $1,000,00 General Liability Insurance.) 2. Attached Site Plan: Page # 3. Attached Electrical One-Line Drawing: Page # (Per MPSC Order in Case No. U-15787, the one-line diagram must be signed and sealed by a licensed professional engineer, licensed in the State of Michigan) 4. Attached Electrical Three-Line Drawing: Page # 5. Attached Specification for Equipment Page # 6. Applicable Technical Appendix (A-C) Page # Note: The following information on these system components shall appear on the preliminary Detail One-Line Diagram Breakers - Rating, location and normal operating status (open or closed) Buses - Operating voltage Capacitors - Size of bank in Kvar Circuit Switchers - Rating, location and normal operating status (open or closed) Current Transformers - Overall ratio, connected ratio Fuses - normal operating status, rating (Amps), type Generators - Capacity rating (kva), location, type, method of grounding Grounding Resistors - Size (ohms), current (Amps) Isolating transformers - Capacity rating (kva), location, impedance, voltage ratings, primary and secondary connections and method of grounding Potential Transformers - Ratio, connection Reactors - Ohms/phase Relays - Types, quantity, IEEE device number, operator lines indicating the device initiated by the relays. Switches - Location and normal operating status (open or closed), type, rating Tagging Point - Location, identification Customer and Contractor Signature and Fees o Attached $500 Interconnection Application Fee (Check #/ Money Order #) ( Sign and Return complete application with Application Fee to Electric Utility Contact ) To the best of my knowledge, all the information provided in this Application Form is complete and correct. Customer Project Developer/Contractor (If Applicable)

APPENDIXES APPENDIX A: Technical Information for Synchonous-Type Generators APPENDIX B: Technical Information for Induction-Type Generators APPENDIX C: Technical Information for Inverter-Type Generators APPENDIX D: Sample One-Line diagram for Synchronous Type Project APPENDIX E: Sample One-Line diagram for Induction Type Project APPENDIX F: Sample One-Line diagram for Inverter Type Project

Appendix A Synchronous Generators Generator Information a. Generator Nameplate Voltage a. b. Generator Nameplate Watts or Volt-Amperes b. c. Generator Nameplate Power Factor (pf) c. d. RPM d. Technical Information e. Minimum and Maximum Acceptable Terminal Voltage e. f. Direct axis reactance (saturated) f. g. Direct axis reactance (unsaturated) g. h. Quadrature axis reactance (unsaturated) h. i. Direct axis transient reactance (saturated) i. j. Direct axis transient reactance (unsaturated) j. k. Quadrature axis transient reactance (unsaturated) k. l. Direct axis sub-transient reactance (saturated) l. m. Direct axis sub-transient reactance (unsaturated) m. n. Leakage Reactance n. o. Direct axis transient open circuit time constant o. p. Quadrature axis transient open circuit time constant p. q. Direct axis subtransient open circuit time constant q. r. Quadrature axis subtransient open circuit time constant r. s. Open Circuit saturation curve s. t. Reactive Capability Curve showing overexcited and underexcited limits (Reactive Information if non-synchronous) t. u. Excitation System Block Diagram with values for gains and time constants (Laplace transforms) u. v. Short Circuit Current contribution from generator at the Point of Common Coupling v. w. Rotating inertia of overall combination generator, prime mover, couplers and gear drives w. x. Station Power load when generator is off-line, Watts, pf x. y. Station Power load during start-up, Watts, pf y. z. Station Power load during operation, Watts, pf z.

Appendix B Induction Generators Generator Information a. Generator Nameplate Voltage a. b. Generator Nameplate Watts or Volt-Amperes b. c. Generator Nameplate Power Factor (pf) c. d.rpm d. Technical Information e. Synchronous Rotational Speed e. f. Rotation Speed at Rated Power f. g. Slip at Rated Power g. h. Minimum and Maximum Acceptable Terminal Voltage h. i. Motoring Power (kw) i. j. Neutral Grounding Resistor (If Applicable) j. k. I 2 2 t or K (Heating Time Constant) k. l. Rotor Resistance l. m. Stator Resistance m. n. Stator Reactance n. o. Rotor Reactance o. p. Magnetizing Reactance p. q. Short Circuit Reactance q. r. Exciting Current r. s. Temperature Rise s. t. Frame Size t. u. Design Letter u. v. Reactive Power Required in Vars (No Load) v. w. Reactive Power Required in Vars (Full Load) w. x. Short Circuit Current contribution from generator at the Point of Common Coupling x. y. Rotating inertia, H in Per Unit on kva Base, of overall combination generator, prime mover, couplers and gear drives y. z. Station Power load when generator is off-line, Watts, pf z. aa. Station Power load during start-up, Watts, pf bb. Station Power load during operation, Watts, pf aa. bb.

Appendix C Inverter Generators Generator Information a. Generator Nameplate Voltage b. Generator Nameplate Watts or Volt-Amperes c. Generator Nameplate Power Factor (pf) d. RPM e. Manufacturer f. Model ( Name / Number ) Technical Information e. Generator Nameplate Voltage f. Generator Nameplate Watts or Volt-Amperes g. Generator Nameplate Power Factor (pf) h. Minimum and Maximum Acceptable Terminal Voltage i. Reactive Capability Curve showing overexcited and underexcited limits (Reactive Information if non-synchronous) j. Short Circuit Current contribution from generator at the Point of Common Coupling k. Station Power load when generator is off-line, Watts, pf l. Station Power load during start-up, Watts, pf m. Station Power load during operation, Watts, pf

Appendix D (Not Required for Flow-Back) One - Line Diagram Name of the Licensed Professional Engineer PE Licensed Number Address Sinagture

Appendix E (Not Required for Flow-Back) One - Line Diagram Name of the Licensed Professional Engineer PE Licensed Number Address

Appendix F Distribution Circuit 32 59 A) One - Line Diagram Name of the Licensed Contractor /PE Contractor Licensed Number Address Sinagture