T- DualScan. StarLab

Similar documents
> StarLab. Multi-purpose Antenna Measurement Multi-protocol Antenna Development Linear Array Antenna Measurement OTA Testing

System configurations. Main features I SG 64 SOLUTION FOR

ANTENNA MEASUREMENT AND RADOME TEST SYSTEMS CATALOG

System configurations. Main features. I TScan SOLUTION FOR

Rapid Antenna Measurement Systems

Software. Equipment. Add-ons. Accessories. Services

Part No. ETH-MMW-1000 (version 1A) Millimeter Measurement System Frequency Range: 18 GHz 75 GHz

Millimeter Wave Measurement System

Main features. System configurations. I Compact Range SOLUTION FOR

Measurement Services. In-house Facilities and Expertise. MEASUREMENT CAPABILITIES: Antenna OTA SAR HAC

HScan. Horizontal Scanner

Specification of Requirements. Request for tenders for antenna systems for Aalborg University. Side 1

Fundamentals. Senior Project Manager / AEO Taiwan. Philip Chang

Measurement Services. In-house Facilities and Expertise. MEASUREMENT CAPABILITIES: Antenna OTA SAR HAC

5G ANTENNA TEST AND MEASUREMENT SYSTEMS OVERVIEW

4GHz / 6GHz Radiation Measurement System

Application Note. StarMIMO. RX Diversity and MIMO OTA Test Range

Gain And Arbitrary Beamwidth Measurement For Identical Test Antennas

An introduction to Mobile Station Over-the-Air measurements

Massive MIMO prototype and mmw OTA Test challenge

Conventional measurement systems

TRADITIONAL ANTENNA MEASUREMENTS AND CTIA OTA MEASUREMENTS MERGING THE TECHNOLOGIES

Millimeter Spherical µ-lab System from Orbit/FR

HOW TO CHOOSE AN ANTENNA RANGE CONFIGURATION

SIGFOX END- PRODUCT RADIATED TEST PLAN FOR SIGFOX READY TM CERTIFICATION

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

Antenna Training and Measuring System

Accurate Planar Near-Field Results Without Full Anechoic Chamber

RAYTHEON 23 x 22 50GHZ PULSE SYSTEM

Radiated Spurious Emission Testing. Jari Vikstedt

IMPROVING AND EXTENDING THE MARS TECHNIQUE TO REDUCE SCATTERING ERRORS

Millimetre Spherical Wave Antenna Pattern Measurements at NPL. Philip Miller May 2009

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

The LACE Antenna Test Ranges

ETS Lindgren Anechoic Chamber

From myth to reality - Leading the industry from conducted to radiated testing for 5G mmwave

Massive MIMO Test and Measurement Challenges and OTA Solutions. Hongwei Kong Ph.D Lab Manager Keysight Labs China

DAMS Full Spherical Mount Option

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

Very-Near-Field Solutions for Antenna Measurement Problems

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

WIESON TECHNOLOGIES CO., LTD.

ANECHOIC CHAMBER DIAGNOSTIC IMAGING

GPS Active Antenna With GPRS Measurement Report

This is a preview - click here to buy the full publication

RECOMMENDATION ITU-R M * TECHNIQUES FOR MEASUREMENT OF UNWANTED EMISSIONS OF RADAR SYSTEMS. (Question ITU-R 202/8)

Over the Air Testing: Important Antenna Parameters, Testing Methodologies and Standards

A CYLINDRICAL NEAR-FIELD VS. SPHERICAL NEAR-FIELD ANTENNA TEST COMPARISON

Frequency Range Peak Data Quasi-Peak Data Average Data (khz) (khz) (khz)

APPLICATIONS OF PORTABLE NEAR-FIELD ANTENNA MEASUREMENT SYSTEMS

ENGINEERING TEST REPORT # C LSR Job #: C-2411 Compliance Testing of: RM186-SM

RF Test Accessories. Antenna Coupler. TC-93010C fitted with F930102A TC-93013A. Frequency Range : 820 ~ 960 MHz. Frequency Range : 0.

Model AS08010, M1 AR System 10kHz 8GHz

Sunlight Supply, Inc.

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

TEST REPORT. Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF. FCC Part 15 Subpart E (UNII) Xirrus Model(s): XN4

Impact of mm-wave Range and Large Bandwidth on RF System Design. R&S Taiwan Feiyu Chen

PERFORMANCE CONSIDERATIONS FOR PULSED ANTENNA MEASUREMENTS

Calibration and Validation for Automotive EMC

The CReSIS Anechoic Chamber is located at: The University of Kansas. M2SEC building W 15 th St. Lawrence, KS

REPORT ITU-R BT Radiation pattern characteristics of UHF * television receiving antennas

OTA Measurement Dedicated Software Suite

Further Refining and Validation of RF Absorber Approximation Equations for Anechoic Chamber Predictions

Reference Environment System Testing of LTE Devices

Antenna Measurement using Vector Network Analyzer. Jong-hwan Keum Agilent Technologies

Dr. John S. Seybold. November 9, IEEE Melbourne COM/SP AP/MTT Chapters

BROADBAND GAIN STANDARDS FOR WIRELESS MEASUREMENTS

SPECIFICATION. Part No. : WCM Product Name: : 2.4GHz Button Antenna

SAGE Millimeter, Inc.

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

A DUAL-PORTED PROBE FOR PLANAR NEAR-FIELD MEASUREMENTS

Differential and Single Ended Elliptical Antennas for GHz Ultra Wideband Communication

FCC Test Report. Report No.: AGC FE08. Attestation of Global Compliance (Shenzhen) Co., Ltd

DF Antennas - Datasheet. Datasheet

Near-Field Antenna Measurements using a Lithium Niobate Photonic Probe

Range Considerations for RF Networks

Transmitarrays, reflectarrays and phase shifters for wireless communication systems. Pablo Padilla de la Torre Universidad de Granada

Developing wireless products can have antenna pitfalls if you don t know what to look for. Roger Denker, MegiQ, namens TOP-electronics

Introduction to Measurement Techniques

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

Semi Anechoic Chamber (SAC)

LUXONDES. See the electromagnetic waves. Product 2018 / 19

5G The overall test challenge from system to device 5G NR T&M aspects

ATC Antenna Test Chamber - Low PIM

A BROADBAND POLARIZATION SELECTABLE FEED FOR COMPACT RANGE APPLICATIONS

Radio compliance test

Narda DF Antennas - Datasheet. Datasheet

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Dinesh Micro Waves & Electronics

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

SPECIFICATION. 3in1 Combination Antenna. GPS/GLONASS/GALILEO 1575~1602MHz. Cellular GSM/CDMA/HSPA/UMTS. Dual band Wi-Fi 2.4GHz / 5.

Space Frequency Coordination Group

ATC Antenna Test Chamber - Low PIM

UNIT - IV SPECIAL ANTENNAS AND ANTENNA MEASUREMENTS. B.Hemalatha - AP/ECE

EMC Evaluation at Green Bank: Emissions and Shield Effectiveness

Earth-Stations. Performance Requirements

UWB.30 Device Active Mode: EIRP

Agilent Antenna and RCS Measurement Configurations Using PNA Microwave Network Analyzers. White Paper

FCC 15B Test Report. : BTv4.0 Dual Mode USB Dongle. Address : Thompson Ave. / Lenexa, Kansas / / USA

Transcription:

T- DualScan StarLab

StarLab is the ultimate tool for antenna pattern measurements in laboratories and production environments where space is limited, cost is critical, and the flexibility of a portable system is required. + A cost-effective and space-saving portable solution SOLUTION FOR Antenna Measurement Linear Array Antenna Measurement OTA Testing Main features Technology Near-field / Spherical Near-field / Cylindrical Measurement capabilities Gain Directivity Beamwidth Cross polar discrimination Sidelobe levels 3D radiation pattern Radiation pattern in any polarization (linear or circular) Antenna efficiency TRP, TIS, EIRP and EIS Frequency bands StarLab 6 GHz: 650 MHz to 6 GHz StarLab 18 GHz: 650 MHz to 18 GHz Max. size of DUT 45 cm for spherical set-up 2.7 m x 45 cm for cylindrical set-up Specific lengths available upon request Max. weight of DUT 10 kg with styrofoam mast 15 kg with heavy DUT mast Typical dynamic range 650 MHz - 6 GHz: 70 db 6 GHz - 18 GHz: 60 db Oversampling Arch rotation System configurations Software Measurement control, data acquisition and post processing SatEnv SPM Near-field/far-field transform SatMap SatCyl OTA measurement suite SAM SMM Advanced post processing SatMap back projection modules Cylindrical back projection modules Insight SatSIM Equipment Arch with probe array, AUT positioner, rubberized absorbers and lighting Control unit Power and control unit Tx and Rx amplification units Instrumentation rack Uninterruptible power supply Vector network analyzer Add-ons Shielded anechoic chamber (OTA testing)* Linear scanner for BTS antenna or linear array antenna measurement (cylindrical testing) OTA Equipment Radio communication tester Active switching unit Transfer Switching Unit I/O switch port WiFi testing Accessories Reference horns PC Heavy DUT mast Laptop support interface Hand and head phantoms Reference antennas (sleeve dipoles, loops,linear array antennas) Services Installation Training Warranty Post warranty service plans * See MVG-EMC Systems catalogs for more information Included Optional Required 23

System overview Data acquisition & processing PC Vector Network Analyzer TX Amplification Unit RX Amplification Unit Control Unit 1 3 2 Active Switching Unit Transfer Swiching Unit Power & Control Unit Radio Communication Tester StarLab uses an Active Switching Unit to switch between near-field passive measurement and OTA measurement RF instrumentation. For near-field passive measurements, a Vector Network Analyzer is used as the RF source/ receiver. The Control Unit drives the two positioning motors and the electronic scanning of the probe arrays. For OTA measurements, the tests are performed through the Radio Communication Tester. The amplification unit amplifies the signal on transmission and reception channels according to the frequency bands. The Transfer Switching Unit is used to switch between the emission by AUT and the reception by AUT modes. The power and control unit supplies the power and drives the RF units. 24 3

Standard system components Arch A choice of two probes can be interleaved (DP 400-6000, DP 6000-18000) Antennas A choice of reference antennas (sleeve dipoles, loops) etc. MVG antenna catalog Mast Styrofoam or ultra rigid mast is provided, according to DUT weight Laptop interface Laptop measurement with StarLab Oversampling with StarLab On a StarLab system, oversampling is performed by a mechanical rotation of the arch in elevation. Oversampling capability is integrated in the mechanical architecture of the system itself (no need for an extra goniometer). Compact shielded chamber for OTA performance measurements System specifications* SPHERICAL STARLAB 6 GHz SPHERICAL STARLAB 18 GHz Measurement time for 11 frequencies** ~ 1 min ~ 1 min Typical dynamic range 70 db 0.65 GHz - 6 GHz: 70 db 6 GHz - 18 GHz: 60 db 10 dbi AUT 20 dbi AUT 30 dbi AUT 10 dbi AUT 20 dbi AUT 30 dbi AUT PEAK GAIN ACCURACY 0.65 GHz - 0.8 GHz ± 1.5 db - - ± 1.5 db - - 0.8 GHz - 1 GHz ± 1.1 db - - ± 1.1 db - - 1 GHz - 6 GHz ± 0.8 db ± 0.7 db - ± 0.8 db ± 0.7 db - 6 GHz - 18 GHz - - - ± 0.9 db ± 0.7 db ± 0.6 db Peak gain repeatability ± 0.3 db ± 0.3 db ± 0.3 db ± 0.3 db ± 0.3 db ± 0.3 db - 10 db SIDELOBES ACCURACY 0.65 GHz - 0.8 GHz ± 1.6 db - - ± 1.6 db - - 0.8 GHz - 1 GHz ± 1.1 db - - ± 1.1 db - - 1 GHz - 6 GHz ± 0.9 db ± 0.6 db - ± 0.9 db ± 0.6 db - 6 GHz - 16 GHz - - - ± 0.8 db ± 0.5 db ± 0.4 db 16 GHz - 18 GHz - - - ± 1.0 db ± 0.6 db ± 0.4 db 25 4

System specifications* SPHERICAL STARLAB 6 GHz SPHERICAL STARLAB 18 GHz 10 dbi AUT 20 dbi AUT 30 dbi AUT 10 dbi AUT 20 dbi AUT 30 dbi AUT - 20 db SIDELOBES ACCURACY 0.65 GHz - 0.8 GHz ± 4.5 db - - ± 4.5 db - - 0.8 GHz - 1 GHz ± 3.5 db - - ± 3.5 db - - 1 GHz - 6 GHz ± 2.7 db ± 0.9 db - ± 2.7 db ± 0.9 db - 6 GHz - 16 GHz - - - ± 2.4 db ± 0.8 db ± 0.5 db 16 GHz - 18 GHz - - - ± 3.2 db ± 1.0 db ± 0.6 db - 30 db SIDELOBES ACCURACY 0.65 GHz - 0.8 GHz - - - - - - 0.8 GHz - 1 GHz - - - - - - 1 GHz - 6 GHz - ± 2.7 db - - ± 2.7 db - 6 GHz - 16 GHz - - - - ± 2.4 db ± 0.8 db 16 GHz - 18 GHz - - - - ± 3.2 db ± 1.0 db * Specifications given according to the following assumptions: Near-field measurement in spherical geometry Controlled temperature and humidity during measurement Specifications on radiation pattern are given for a normalized pattern Measurements inside an anechoic chamber or equivalent conditions Usage of an Agilent PNA with 1kHz IF BW Peak gain is given for a ± 0.3 db of gain error on the reference antenna DUT phase center does not exceed 8 cm from arch center Measurement performed with a suitable mast, depending on the load and directivity of the DUT ** No oversampling, no averaging 26 System specifications* CYLINDRICAL STARLAB 6 GHz Measurement time** 3 min Maximum DUT size*** 45 cm Typical cross polar level that can be measured < -30 db PEAK GAIN ACCURACY 892 MHz ± 1.0 db 1880 MHz ± 0.7 db Peak gain repeatability ± 0.3 db -10 db SIDELOBES ACCURACY 892 MHz ± 0.8 db 1880 MHz ± 0.6 db -20 db SIDELOBES ACCURACY 892 MHz ± 1.1 db 1880 MHz ± 0.9 db BEAM WIDTH ACCURACY 892 MHz ± 5% 1880 MHz ± 5% FRONT TO BACK RATIO ACCURACY**** 892 MHz ± 2.5 db 1880 MHz ± 2.0 db * Specifications given according to the following assumptions: Near-field measurement in cylindrical geometry Controlled temperature and humidity during measurement Specifications on radiation pattern are given for a normalized pattern Usage of an Agilent PNA with 1kHz IF BW except for typical dynamic range with 100 Hz IF BW Peak gain is given for a ± 0.3 db of gain error on the reference antenna DUT phase center does not exceed 15 cm from arch center ** 3m scan, no oversampling *** Diameter of the maximum cylinder that can be measured **** Typical specifications in a ± 30 cone Mechanical characteristics External dimensions of StarLab Probe array internal diameter Optional anechoic chamber size 1.82 x 1.08 x 2.00 m (L x W x H) 0.9 m Angle between probes in the same frequency band 22.5 DUT MAX. WEIGHT* Styrofoam mast Ultra rigid mast * Centered load RF equipment characteristics 1.92 x 1.97 x 2.08 m 10 kg 25 kg Number of probes StarLab 6 GHz 15 + 1 reference channel StarLab 18 GHz 0.65 to 6 GHz 15 + 1 reference channel 6 to 18 GHz 14 + 1 reference channel Frequency range StarLab 6 GHz StarLab 18 GHz 0.65 GHz to 6 GHz 0.65 GHz to 18 GHz 5

Maximum diameter of the DUT (m) FREQUENCY NUMBER OF OVERSAMPLING (GHz) x 1 x 2 x 3 x 5 x 10 0.65 0.45 0.45 0.45 0.45 0.45 1 0.45 0.45 0.45 0.45 0.45 2 0.38 0.45 0.45 0.45 0.45 3 0.25 0.45 0.45 0.45 0.45 4 0.19 0.38 0.45 0.45 0.45 5 0.15 0.31 0.45 0.45 0.45 6 0.13 0.25 0.38 0.45 0.45 7 0.11 0.22 0.33 0.45 0.45 8 0.10 0.19 0.29 0.45 0.45 9 0.08 0.17 0.25 0.42 0.45 10 0.08 0.15 0.23 0.38 0.45 11 0.07 0.14 0.21 0.35 0.45 12 0.06 0.13 0.19 0.32 0.45 13 0.06 0.12 0.18 0.29 0.45 14 0.05 0.11 0.16 0.27 0.45 15 0.05 0.10 0.15 0.25 0.45 16 0.05 0.10 0.14 0.24 0.45 17 0.04 0.09 0.13 0.22 0.45 18 0.04 0.08 0.13 0.21 0.42 Linear scanner option By adding a linear scanner, StarLab is converted from a spherical to a cylindrical near-field measurement system, which is particularly suitable to linear antenna measurements like BTS. In addition to the standard features, this configuration allows the measurements of the beam tilt. StarLab in cylindrical mode can measure sidelobes up to 70 (typical) from boresight. Linear antenna measurement characteristics Geometry Standard rail length Linear antenna max. weight Cylindrical 6 or 9 meters 80 kg OTA performance testing StarLab can perform both TRP and TIS measurements. For TIS measurements, or where external interference is a concern a small shielded chamber for StarLab is available. The chamber is lined with pyramid absorbers on the two walls facing the openings of the StarLab anechoic cylinders. OTA performance measurement specifications* ACCORDING TO CTIA SPECIFICATIONS TRP accuracy free space TRP accuracy talk position TRP repeatability Typical TRP measurement time** TIS accuracy free space TIS accuracy talk position TIS repeatability Typical TIS measurement time*** CTIA COMPARABLE GSM/WCDMA protocols: TIS based on Rx Level accuracy TIS based on Rx Level repeatability Typical TIS based on Rx level measurement time*** CDMA2000 protocol: TIS optimized accuracy TIS optimized repeatability Typical TIS optimized measurement time*** <± 1.9 db <± 2.0 db ± 0.3 db < 2 min <± 2.0 db <± 2.1 db ± 0.5 db 15 min > 60 min <± 2.8 db <± 1.5 db < 6 min <± 2.0 db <± 0.5 db < 11 min * Specifications given according to the following assumptions: Controlled temperature and humidity during measurement Measurements inside an anechoic chamber DUT phase center does not exceed 15 cm from arch center Calibration done with dipole gain reference values Measurement performed with a suitable mast depending on the load and directivity of the DUT Specifications also depend on Radio Communication Tester and Protocol ** One channel, 15 deg sampling, one time each probe, measurement time depends on protocol *** One channel, 30 deg sampling, one time each probe, measurement time depends on protocol StarLab with linear scanner option StarLab 18 GHz with linear scanner option Copyright MVG 2014 Product specifications and descriptions in this datasheet are subject to change without notice. Actual products may differ in appearance from images shown. 27 6