CHAPTER 3 MODIFIED FULL BRIDGE ZERO VOLTAGE SWITCHING DC-DC CONVERTER

Similar documents
CHAPTER 2 PHASE SHIFTED SERIES RESONANT DC TO DC CONVERTER

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

Simplified loss analysis and comparison of full-bridge, full-range-zvs DC-DC converters

Conventional Single-Switch Forward Converter Design

K.Vijaya Bhaskar. Dept of EEE, SVPCET. AP , India. S.P.Narasimha Prasad. Dept of EEE, SVPCET. AP , India.

CHAPTER 4 PI CONTROLLER BASED LCL RESONANT CONVERTER

Novel Soft-Switching DC DC Converter with Full ZVS-Range and Reduced Filter Requirement Part I: Regulated-Output Applications

Soft Switched Resonant Converters with Unsymmetrical Control

Chapter 4 SOFT SWITCHED PUSH-PULL CONVERTER WITH OUTPUT VOLTAGE DOUBLER

Simulation of Soft Switched Pwm Zvs Full Bridge Converter

DC-DC Resonant converters with APWM control

CHAPTER 6 BRIDGELESS PFC CUK CONVERTER FED PMBLDC MOTOR

Voltage Fed DC-DC Converters with Voltage Doubler

LeMeniz Infotech. 36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue, Pondicherry Call: , ,

Chapter 6 ACTIVE CLAMP ZVS FLYBACK CONVERTER WITH OUTPUT VOLTAGE DOULER

3. PARALLELING TECHNIQUES. Chapter Three. high-power applications to achieve the desired output power with smaller size power

CHAPTER 2 DESIGN AND MODELING OF POSITIVE BUCK BOOST CONVERTER WITH CASCADED BUCK BOOST CONVERTER

Presentation Content Review of Active Clamp and Reset Technique in Single-Ended Forward Converters Design Material/Tools Design procedure and concern

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

CHAPTER 3. SINGLE-STAGE PFC TOPOLOGY GENERALIZATION AND VARIATIONS

ZCS-PWM Converter for Reducing Switching Losses

Lecture 19 - Single-phase square-wave inverter

Designing and Implementing of 72V/150V Closed loop Boost Converter for Electoral Vehicle

Chapter 3 : Closed Loop Current Mode DC\DC Boost Converter

PI Controller Based New Soft-Switching Boost Converter With A Coupled Inductor

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

CHAPTER 4 DESIGN OF CUK CONVERTER-BASED MPPT SYSTEM WITH VARIOUS CONTROL METHODS

Experiment DC-DC converter

Simulation and Performance Evaluation of Closed Loop Pi and Pid Controlled Sepic Converter Systems

Chapter 3 HARD SWITCHED PUSH-PULL TOPOLOGY

A New Phase Shifted Converter using Soft Switching Feature for Low Power Applications

Chapter 2 LITERATURE REVIEW

CHAPTER 2 AN ANALYSIS OF LC COUPLED SOFT SWITCHING TECHNIQUE FOR IBC OPERATED IN LOWER DUTY CYCLE

A Color LED Driver Implemented by the Active Clamp Forward Converter

A New ZVS Bidirectional DC-DC Converter With Phase-Shift Plus PWM Control Scheme

Soft switching of multioutput flyback converter with active clamp circuit

IN THE high power isolated dc/dc applications, full bridge

APPLICATION NOTE AN02

A Voltage Quadruple DC-DC Converter with PFC

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

25 Watt DC/DC converter using integrated Planar Magnetics

CHAPTER 5 MODIFIED SINUSOIDAL PULSE WIDTH MODULATION (SPWM) TECHNIQUE BASED CONTROLLER

Multiple Output Converter Based On Modified Dickson Charge PumpVoltage Multiplier

HIGH FREQUENCY DC-DC CONVERTER DESIGN USING ZERO VOLTAGE SWITCHING

A Novel Technique to Reduce the Switching Losses in a Synchronous Buck Converter

Zero Voltage Switching In Practical Active Clamp Forward Converter

LLC Resonant Converter for Battery Charging Application

COMPARISON OF SIMULATION AND EXPERIMENTAL RESULTS OF ZVS BIDIRECTIONAL DC-DC CONVERTER

High Performance ZVS Buck Regulator Removes Barriers To Increased Power Throughput In Wide Input Range Point-Of-Load Applications

An Improvement in the Virtually Isolated Transformerless Off - Line Power Supply

1. The current-doubler rectifier can be used to double the load capability of isolated dc dc converters with bipolar secondaryside

Improvements of LLC Resonant Converter

Design Consideration for High Power Zero Voltage Zero Current Switching Full Bridge Converter with Transformer Isolation and Current Doubler Rectifier

Chapter 6: Converter circuits

Design and Implementation of Closed Loop LCL-T Resonant DC-to- DC Converter Using Low Cost Embedded Controller

Dr.Arkan A.Hussein Power Electronics Fourth Class. Commutation of Thyristor-Based Circuits Part-I

SIMULATION STUDIES OF HALF-BRIDGE ISOLATED DC/DC BOOST CONVERTER

EMBEDDED CONTROLLED ZVS DC-DC CONVERTER FOR ELECTROLYZER APPLICATION

ZVT Buck Converter with Synchronous Rectifier

DESIGN AND DEVELOPMENT OF HIGH FREQUENCY RESONANT TRANSITION CONVERTER

Hybrid Transformer Based High Boost Ratio DC-DC Converter for Photovoltaic Applications

A Merged Interleaved Flyback PFC Converter with Active Clamp and ZVZCS

Soft-Switching DC-DC Converters Based on A Phase Shift Controlled Active Boost Rectifier Using Fuzzy Controller

IN recent years, the development of high power isolated bidirectional

Implementation of Resistor based Protection Scheme for the Fault Conditions and Closed Loop Operation of a Three-Level DC-DC Converter

Comparison of Simulation and Experimental Results of Class - D Inverter Fed Induction Heater

CHAPTER 6 IMPLEMENTATION OF FPGA BASED CASCADED MULTILEVEL INVERTER

Design and Hardware Implementation of L-Type Resonant Step Down DC-DC Converter using Zero Current Switching Technique

CHAPTER 4 4-PHASE INTERLEAVED BOOST CONVERTER FOR RIPPLE REDUCTION IN THE HPS

Vishay Siliconix AN724 Designing A High-Frequency, Self-Resonant Reset Forward DC/DC For Telecom Using Si9118/9 PWM/PSM Controller.

CHAPTER 3 H BRIDGE BASED DVR SYSTEM

IJMIE Volume 2, Issue 9 ISSN:

A Two Level Power Conversion for High Voltage DC Power Supply for Pulse Load Applications

IN A CONTINUING effort to decrease power consumption

Soft-Switching Two-Switch Resonant Ac-Dc Converter

Interleaved PFC technology bring up low ripple and high efficiency

Modified Resonant Transition Switching for Buck Converter

새로운무손실다이오드클램프회로를채택한두개의트랜스포머를갖는영전압스위칭풀브릿지컨버터

CHAPTER 7 HARDWARE IMPLEMENTATION

A New Active Soft Switching Technique for Pulse Width Modulated Full Bridge DC-DC Converters

CHAPTER 3 APPLICATION OF THE CIRCUIT MODEL FOR PHOTOVOLTAIC ENERGY CONVERSION SYSTEM

AN726. Vishay Siliconix AN726 Design High Frequency, Higher Power Converters With Si9166

HALF BRIDGE CONVERTER WITH WIDE RANGE ZVS

MODELING AND SIMULATION OF LLC RESONANT CONVERTER FOR PHOTOVOLTAIC SYSTEMS

M-Power 2A Series of Multi-chip Power Devices

6. Explain control characteristics of GTO, MCT, SITH with the help of waveforms and circuit diagrams.

CHAPTER 3 DC-DC CONVERTER TOPOLOGIES

GaN in Practical Applications

Alternated duty cycle control method for half-bridge DC-DC converter

A Pv Fed Buck Boost Converter Combining Ky And Buck Converter With Feedback

Chapter 6 Soft-Switching dc-dc Converters Outlines

CHOICE OF HIGH FREQUENCY INVERTERS AND SEMICONDUCTOR SWITCHES

Designers Series XII. Switching Power Magazine. Copyright 2005

Oscillators. An oscillator may be described as a source of alternating voltage. It is different than amplifier.

A HIGHLY EFFICIENT ISOLATED DC-DC BOOST CONVERTER

Single Phase Induction Motor Drive using Modified SEPIC Converter and Three Phase Inverter

High Frequency Isolated Series Parallel Resonant Converter

DESIGN OF SWITCHED MODE POWER SUPPLY

An Asymmetrical Dc-Dc Converter with a High Voltage Gain

A NOVEL SOFT-SWITCHING BUCK CONVERTER WITH COUPLED INDUCTOR

Transcription:

53 CHAPTER 3 MODIFIED FULL BRIDGE ZERO VOLTAGE SWITCHING DC-DC CONVERTER 3.1 INTRODUCTION This chapter introduces the Full Bridge Zero Voltage Switching (FBZVSC) converter. Operation of the circuit is explained. Design procedure is presented. Simulation and experimental results are presented to support the design procedure. Section 3.2 introduces the modified Full Bridge Zero Voltage Switching converter. Design procedure is explained in section 3.4.Simulation and experimental results are presented in section 3.5 and 3.6 respectively. 3.2 FULL BRIDGE ZERO VOLTAGE SWITCHING DC-DC CONVERTER The Full Bridge Zero Voltage Switching converter (FBZVSC) is shown in Figure 3.1. By adding a simple external commutating aid circuit to the full bridge DC-DC converter with phase shift control and by reducing the magnetizing inductance, optimum performance can be obtained. ZVS operation and high conversion efficiency can be achieved from full load down to almost zero load. Constant-frequency, phase-shifted operation of the primary side switches provides a convenient method for achieving zerovoltage turn on of the switches, which significantly reduces switching losses.

54 The Full Bridge Zero Voltage Switching converter consists of a DC source, an inverter, an isolation transformer, an uncontrolled bridge rectifier, an inductor, a capacitor and the load. The DC input is inverted; high frequency AC voltage is fed to uncontrolled bridge rectifier through isolation transformer. The output of rectifier is fed to LC resonating circuit and henceforth to the load. Figure 3.1 FBZVS DC-DC Converter The ZVS energy stored in the primary inductor is dependent on its inductance value and the volt-second product of the secondary of the auxiliary transformer T. The size of the primary inductor can be minimized by properly selecting the turns ratio of the auxiliary transformer T. The size of the primary inductor is very much reduced, compared to that of the conventional PS FB converter. Because of the energy used to create the ZVS condition at light loads is not stored in the leakage inductances of the transformer T, The transformer s leakage inductances can also be minimized. As a result of the reduced total primary inductance (the inductance of the primary inductor used for ZVS energy storage and the leakage inductance of the power transformer, FBZVS converter exhibits a relatively small duty cycle loss. It minimizes the conduction loss of the primary switches, the voltage stress on the components in the secondary side of the transformer, and improves the conversion efficiency. Due to reduced total primary inductance, the secondary side

55 parasitic ringing is also reduced and is effectively controlled by the primary side diodes D 1 and D 2. 3.3 OPERATING PRINCIPLE Figure 3.2. Modified Full Bridge Zero Voltage Switching converter is shown in M1 IRF840 C1 M3 IRF840 C3 TX1 L0 1 2 D1 D2 Vdc V1 Cdc1 La 1 2 Cdc2 1N4007 C0 R TX2 1n D3 D4 M2 IRF840 C2 M4 C4 IRF840 Figure 3.2 Modified FBZVS DC-DC Converter Modified FBZVS DC-DC converter employs a series inductor and two capacitors to achieve zero voltage switching. The differences between the modified and conventional FBZVS converter are as follows. The DC blocking capacitor of conventional converter is split into two capacitors,c dc1 and C dc2 in the modified circuit. The conventional converter uses a single high-frequency transformer, whereas it is divided into two transformers T x1 and T x2 (with primary-to-secondary turns ratio of N: 1) in the modified circuit.

56 The modified circuit has additional inductor L a which adaptively stores additional energy for ZVS operation when the stored energy transformer leakage is inadequate. The secondary windings of the transformers are connected in series. The leakage inductances of both the transformers are shown in Figure 3.2 as a lumped inductor L 0 in series with secondary windings. Figure 3.3 shows the operation principle waveforms of modified FBZVS. The diodes, inductors and capacitor C 0 together act as current doubler and the same inductor and capacitors act as filters. R is the load resistance. By using the series connected primary winding, DC blocking capacitor and a saturable inductor the primary current can be reduced to zero. The conventional FBZVS has limited range. When load current is low the ZVS is lost as the energy stored in the leakage inductance of the transformer is insufficient to discharge the switch and transformer capacitances. While extending the range of ZVS operation, the full load conduction loss increases. The main power transformer is divided into two half rated transformers and an uncoupled inductor to achieve ZVS over entire conversion range. The converter is suitable over wide range and load resistance is varied. The converter is analyzed for low power, varying load resistance and high frequency. When duty cycle is high, the load current is high. Energy stored in transformer leakage inductance is sufficient for ZVS operation. Auxiliary current is low thereby causing low additional conduction losses. When duty cycle is low, load current is low and energy in transformer leakage inductance is insufficient for ZVS operation. Hence Auxiliary current increases and assists to achieve ZVS operation from full load to approximately 35% of load. At low power the auxiliary current is circulates in all the four switches causing more conduction loss.

57 By properly selecting the duty cycle for the switches, optimal values for resonant components the efficiency of modified FBZVS at light loads can be improved. The operation of the circuit is divided into four modes. Figure 3.3 Operation principle waveforms of modified FBZVS Mode-1[t 0,t 1 ] The MOSFETs M 1 and M 2 are turned on. In steady state the output capacitor C o is charged. The current in the input side flows through M 1, primary, M 4 and back to the source. In the secondary side the diodes D 1 and D 4 conduct and the energy is transferred to the output capacitor. Mode-2 [t 1,t 2 ] The pulse to M 4 is withdrawn and the driving pulse is given to M 3 along with M 1.The charging started in the primary circulates current through the MOSFETs M 1 and M 3. D 1 and D 4 continue to conduct in the secondary side.

58 Mode-3 [t 2,t 3 ] The pulse to M 1 is withdrawn and pulse is applied to M 2 along with M 3.The diodes D 1 and D 4 continue to conduct due to the energy in the filter inductance. The diodes D 2 and D 3 conduct due to the forward bias given by the secondary of the transformer. This is called period of overlap.d 1 and D 4 get turned off by the end of this mode. Mode- 4 [t 3,t 4 ] The pulse to M 3 is withdrawn and pulse is applied to M 4.The energy in the primary circulates current. Through the devices M 2 and M 4 diodes D 2 and D 3 continue to conduct. 3.4 DESIGN PROCEDURE specifications: The proposed converter is designed for the following Table 3.1 Design parameters of modified FBZVS Input Voltage V i 48V Input Power 48w Output Voltage V o 12 V Time period 26µs Resonant Frequency = 38 khz The design values are as follows for the above specification. V V o S (3.1) i s = 12/48 = 0.25

59 Power is given by P o 2 Vo R (3.2) Therefore Resistance value is given by 2 Vo R 4 (3.3) P o T s 1 f s (3.4) T s 1 5 f s 2.6 10 sec L 1 Ts.(1 s). R (3.5) 2 The value of L 1 is 39 µh Transformer design E 1 = 4.44. N 1. m. f (3.6) E 1 =48 V, N 1 =60, m= 10µwb Number of turns in the primary winding N 1 = 28 E 2 = 4.44.N 2.. f (3.7) N E 2 2 N1 E1 Number of turns in the secondary winding N 2 = 7 Ripple factor r = 4% Ripple factor(r) is given by

60 r 4 1 3 fcr (3.8) 0.04 = 1 / 4 3.f.C.R C = 23µF f s 2 1 LC (3.9) L =0.75 µh r 3 2 L C (3.10) 0 0 Therefore L o =3.6 µh I o = 3 A Conduction losses w c = 2. V 0 s.i D = 1.5 w (3.11) Conduction Loss in diode = 0.7. I 0 Iron loss w i = 2% of the rated power = 0.72w Vo. Io V I w o. o c w i (3.12) Therefore Converter efficiency = 94 % 3.5 SIMULATION RESULTS The simulation is carried out using MATLAB/Simulink. The simulation circuit is shown in Figure 3.4. Input voltage is 48V DC which is shown in Figure 3.5. The Driving pulses, transformer s primary winding voltage, DC output voltage and current are also shown in Figure 3.5.

61 Figure 3.4 Simulink model of modified FBZVS DC-DC converter The driving pulse, current and voltage of switch S 1 is shown in Figure 3.6. The driving pulse, current and voltage of switch S 4 is shown in Figure 3.7. Figure 3.6 shows the S 1 s driving signal gate-source voltage, drain-source voltage and the current flowing through drain-source. It can be observed I ds3 is negative before the arrival of the driving signal, which assures that V ds1 decreases to zero before the switch turning on and achieves ZVS. From Figure 3.7 it is observed that the voltage from drain to source of S 4 decreases to zero before the switch turns on and achieves ZVS. Hence turnoff loss is negligible. Figure 3.8 shows the output voltage and output current. The switching frequency is 38.3 khz. Table 3.2 Simulation parameters of modified FBZVS DC input voltage 48V L a 32 µh Resonant frequency 38 khz C dc1 1 µf C 0 470 µf C dc2 1 µf R 0 4 L 0 10 µh

62 Figure 3.5 Simulation waveforms of modified Full bridge ZVS Figure 3.6 (a) Driving pulse, (b) current and (c) voltage across switch1

63 Figure 3.7 (a) Driving pulse, (b) current and (c) voltage across switch4 Figure 3.8 DC output voltage and current DC output voltage is found to be 12V and the current is 3.05A.There is no overlapping between voltage and current wave forms. Hence the conduction losses are minimized. DC output voltage and current are free from ripple. The load is varied from 35.5% to 100% and the performance of the converter is observed and tabulated. Table 3.3 shows the performance of the modified FBZVS for changes in % of load. Table 3.4 shows the performance of the modified FBZVS for changes in input voltage.

64 Table 3.3 Performance of the modified FBZVS DC-DC converter for changes in load % of Output Output Output Input fficiency load voltage(v) current(a) power(w) power(w) (%) 35.5 12.55 0.64 8.03 9.77 82.21 50 12.48 0.83 10.36 12.40 83.54 62.5 12.3 1.4 17.22 20.38 84.5 75 12.23 2 24.46 28.74 85.1 87.5 12.1 2.52 30.49 35.66 85.49 100 12 3.05 36.6 42.7 85.71 Table 3.4 Performance of the modified FBZVS DC-DC converter for changes in input voltages Input voltage (V) Input current (A) Input power (w) Output voltage (V) Output current (A) Output power (w) Efficiency (%) 40 0.66 26.4 11.5 1.93 22.2 84.09 44 0.82 36.08 11.95 2.56 30.62 84.87 48 0.89 42.72 12 3.05 36.6 85.67 52 0.94 48.88 12.3 3.42 42.06 86.04

65 Figure 3.9 Input voltage versus output voltage Figure 3.10 Input voltage versus output power Figure 3.11 Input voltage versus efficiency From Figure 3.9 and 3.10 it is observed that the output voltage varies slightly with respect to input voltage and output power increases with increase in input voltage. From Figure 3.11 it is observed that efficiency is flat over the entire range of input voltage.

66 Figure 3.12 R- load (%) versus output voltage Figure 3.13 R- load (%) versus output power Figure 3.14 R- load (%) versus efficiency From Figure 3.14 it is evident that the efficiency at light load is improvised than conventional converter.

67 3.5.1 Comparison of Open Loop System with Closed Loop System with Step Change in Input Voltage The simulink model of open loop system is shown in Figure 3.15. A step change in voltage is applied at the input. The DC input voltage, output current, and output voltage with input step change is shown in Figure 3.16. When input voltage is increased to a value of 60V at 0.4s, the output voltage also increases and settles at new value of 15V. Figure 3.15 Open loop system with step change in input Figure 3.16 Results of open loop system with step change in input (a) Input voltage (b) Output current (c) Output voltage

68 Figure 3.17 Closed loop system with step change input The simulink model of closed loop system is shown in Figure 3.17. In order to maintain the required output voltage level, closed loop control is used. The instantaneous voltage signal is taken from the output and given to a comparator. Other input to the comparator is the set voltage of 12V.Output of the comparator is the error signal which is given to the PI controller. The output of PI controller is compared with a reference triangular wave form of peak value 17 and time period 0.1ms to generate PWM waves as shown in Figure 3.19. They are used as control signals for the gates of MOSFETs S 1 to S 4.The DC input voltage, output current, and output voltage with input step change are shown in Figure 3.18. The parameters of PI controller are shown in Table 3.5. Figure 3.18 Results of closed loop system with step change in input (a) Input voltage (b) Output current (c) Output voltage

69 The step change is applied at 0.4 seconds for open loop system as shown in Figure 3.15. From Figure 3.16 it is observed that the open loop system has steady state error and its peak value is 15V. For the closed loop system shown in Figure 3.17, the input voltage is increased to 60V at 0.4 seconds. From Figure 3.18 it is observed that the control circuit takes proper action and the output voltage is maintained at 12V.Set voltage is taken as 12V.The closed loop system reduces the steady state error. It settles at 0.72s. The settling time is 0.32s. Figure 3.19 a. PI controller output b. Reference voltage c. PWM waves Table 3.5 Parameters of PI controller Proportional gain(k p ) 3 Integral gain(k i ) 50 Output limits [1 e6-1e6] Sample time 50 e-6

70 3.5.2 Comparison of Open Loop System with Closed Loop System for Output Load Regulation The simulink model of open loop system without output load regulation is shown in Figure 3.20. Input voltage is 48V DC. A breaker is connected in parallel with the load. Load resistance is 4. The breaker is opened at initial state and it is closed at 0.4s. DC output voltage is shown in Figure 3.21 where the output voltage is increased at 0.4s due to change in the load. Figure 3.20 Open loop system without output load regulation Figure 3.21 DC output voltage with step change in load

71 The simulink model of closed loop system for output load regulation is shown in Figure 3.22. Input voltage is 48V DC. Set voltage is 12V DC. In order to maintain the required output voltage level, closed loop control is used. The instantaneous output voltage signal is given to a comparator. Other input to the comparator is the set voltage.output of the comparator is the error signal which is given to the PI controller. The output of PI controller is compared with a triangular reference signal to generate gate pulses. They are used as control signals for the gates of MOSFETs S 5 and S 6. Figure 3.22 Closed loop system with output load regulation Figure 3.23 DC output voltage of closed loop system

72 The breaker is opened at initial state and it is closed at 0.4s.When the breaker is closed, due to load side disturbance the output voltage increases to a value of 13.9V.But the closed loop system settles the output voltage to a value of 12V at 0.8s as shown in Figure 3.23. The settling time is 0.4s. 3.6 EXPERIMENTAL RESULTS The DC-DC converter was built and tested for open loop modified FBZVS at 48 V DC. The hardware layout is shown in Figure 3.24. The circuit parameters are as follows. Table 3.6 Experimental parameters of modified FBZVS L a 32 µh R 0 4 C 0 470 µf L 0 10 µh The switching frequency is 38.3 khz. The pulses are generated using 89C2051. Crystal and two capacitors are connected externally. The pulses are amplified using the driver IR 2110. Each driver is capable of driving two MOSFETs. Two drivers are required to control four MOSFETs. Experimental waveform of driving pulses of switch3 and switch1 is shown in Figure 3.25. Driving pulses of switch4 and switch2 is shown in Figure 3.26. The primary side voltage of the transformer is shown in Figure 3.27. The secondary side voltage of the transformer is shown in Figure 3.28.Load voltage waveform is shown in Figure 3.29 and the output voltage is shown in Figure 3.30. The output voltage is 12V.

73 Figure 3.24.Hardware layout of modified FBZVS DC-DC converter Figure 3.25 (a) Driving pulses of MOSFET3 (b) Driving pulses of MOSFET1

74 Figure 3.26 (a) Driving pulses of MOSFET4 (b) Driving pulses of MOSFET2 X axis 1 div = 10 µs; Y axis1div =20V Figure 3.27 Primary side voltage of the transformer

75 X axis 1 div = 10µs. Y axis 1 div=10v Figure 3.28 Secondary side voltage of the transformer X axis 1 div = 10µs, Y axis 1 div =10V Figure 3.29 Load voltage waveform

76 Figure 3.30 Output voltage across the load The output voltage across the load from open loop experimental result is 12V and the output voltage from simulation result is 12V. Hence the experimental results closely agree with the simulation results. 3.7 SUMMARY Modified FBZVS DC to DC converter is modeled using the blocks of simulink. Soft switched FB ZVS DC to DC converter is analysed, simulated, tested and the results are presented. The converter is designed for low power, varying load resistance and high frequency conditions. When duty cycle is low, load current is low and energy in transformer leakage inductance is insufficient for ZVS operation. Hence the auxiliary current increases and assists to achieve ZVS operation from full load to approximately 35% of load. At light loads the auxiliary current is circulating in all the four switches causing more conduction loss. By properly selecting the duty cycle for the switches, optimal values for resonant components the efficiency of modified FBZVS at low load is improved and it is found to be 85.71% at full load and

77 82.21% at 35.5% of load. Switching losses and stresses are reduced using zero voltage switching over entire conversion range. The experimental results closely agree with the simulation results. In order to maintain the required output voltage level, a closed loop circuit model was developed, and it was used for simulation studies. It is observed that the control circuit takes proper action to reduce the peak amplitude from 15V to 12V. The closed loop system reduces the steady state error and settles at 0.72s.The Settling time is 0.32s.