SAR TEST REPORT. According to the standard: EN : 2006

Similar documents
This report cancels and replaces the test report R052-DAS /A Ed. 0 SAR TEST REPORT. According to the standard: EN : 2006

SAR TEST REPORT. According to the standard: EN : 2006 Fast measurements. Company: FAZUP

SAR TEST REPORT. According to the standard: EN : Equipment under test: Horizontal case for Smartphone Duthilleul Process

SAR Compliance Test Report

Area. Tune-up. Head SAR. 10mm)

SAR Compliance Test Report

Appendix for the Report Dosimetric Assessment of the Portable Device Selex Elsag S.p.A. PUMA T3 plus (FCC ID: X5Y )

SAR Compliance Test Report

SAR Test Report. Report Number: M Evaluation of the SAR of IPhone 6 series when fitted with the Cellsafe Radi

WiFi 2.4 GHz. 0 db = 0.120mW/g = db mw/g. Test Laboratory: Lab C Date: 8/3/2012

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD

CE SAR EVALUATION REPORT. Shenzhen Hongjiayuan Communication Technology Co., Ltd.

TEST REPORT. Test Report No.: /09. Test Standard/s

Report Number: M140907_R1 (Replacing M140907) Evaluation of the SAR of Samsung Galaxy and Apple iphones When Fitted With the Cellsafe Smart Chip

Portable Cellular Phone SAR Test Report

SAR Test Report. Report Number: M Evaluation of the SAR of Apple iphones When Fitted with the Brainwave Patchd

Report Number: M151240_R2 (Replacing M151240_R1) Evaluation of the SAR of Samsung Galaxy S6 when fitted with the Cellsafe Wide

9:36:11. Phantom. Measurement. Peak SAR

SAR Test Report. Report Number: M Evaluation of the SAR of Samsung Galaxy and Apple iphones When Fitted With the Brainwave Smart Chip

WiFi 2.4GHz_Body. 0 db = 0.123mW/g. Date/Time: 10/11/ :35:06 AM. Test Laboratory: UL CCS SAR Lab D

Intel SAR Test Report

APPENDIX B PLOTS OF THE SAR MEASUREMENTS

Shenzhen Academy of Information and Communications Technology SAR TEST REPORT. No. B17N01624-SAR. For. Roam Data Inc. POS Tablet. Model Name: Moby/M70

Report No:139135R-HPUSP10V01. FCC Test Report

DECLARATION OF COMPLIANCE SAR RF EXPOSURE EVALUATION FCC & IC

TEST REPORT OET 65C. Report Reference No... : TRE R/C: FCC ID...:

TEST REPORT. In the configuration tested, the EUT complied with the standards specified above. Remarks:

RESEARCH DEVELOPMENT AND TESTING NATIONAL INSTITUTE FOR ELECTRICAL ENGINEERING I C M E T CRAIOVA

FCC SAR Test Report (Class II Permissive Change)

FCC SAR Test Report. : Motorola Mobility, LLC. : Mobile Cellular Phone. STANDARD : FCC 47 CFR Part 2 (2.1093) ANSI/IEEE C IEEE

RF EXPOSURE EVALUATION SPECIFIC ABSORPTION RATE SAR TEST REPORT

SAR Test Report. Report Number: M170410F

SAR Test Report. : Panasales Clearance centre Pty. Ltd. TA Cellsafe Pty Ltd. : Cellsafe UNIVERAL RADI-CHIP TEST DATES : 2017/5/10 ~ 2017/5/26

FCC OET BULLETIN 65 SUPPLEMENT C IEEE STD 1528:2003 RSS-102 Issue 4, March 2010 RSS-102 Supplementary Procedures (SPR)-001, January 1, 2011

Blackshark. Co., Ltd. Applicant. Product. Brand SKR-H0. Model. Report No. Issue Date. TA Technology

Test Report. Test Report Identifier: SC b. Tested Device: Bluetooth USB Dongle - m2m Blue According to the standards: IEEE

Intel SAR Test Report

FCC SAR TEST REPORT. No for AZUMI S.A. Mobile Phone. Model Name: L3GA FCC ID: QRP-AZUMIL3GA. Issued Date:

SAR Test Report. Report Number: M080928

SAR Test Report. Sporton International (Shenzhen) Inc.

: Sutter Blvd, Morgan Hill, CA95037 USA

TEST REPORT. Test Report No.: / Test Standard/s

Specific Absorption Rate (SAR) Test Report

DIRECTORY SZ S02 1. TESTING LABORATORY... 4

TEST REPORT. No. I17D00062-SAR01. For. Client: MobiWire SAS. Production: 3G Feature Phone. Model Name: MobiWire Sakari FCC ID: QPN-SAKARI

FCC SAR TEST REPORT. ADDRESS: 9F, No.111-6, Shing-De Rd., San-Chung District, New Taipei City 24158, Taiwan, R.O.C

Function Entrust TEST REPORT

SAR TEST REPORT. REPORT NO.: SA920828R02C MODEL NO.: F5D7011 RECEIVED: NA TESTED: Sept. 19, APPLICANT: Belkin Corporation

DIRECTORY DIRECTORY Introduction SAR Definition System Setup Validation Results...15

SAR EVALUATION REPORT

SAR E146R-065. Applicant. Model Name DUT Type S4335-W. Certification FCC ID IC ID. June 19, 2014 ONETECH. Date of Test. Test Laboratory.

SAR EVALUATION REPORT. Grandstream Networks, Inc.

DIRECTORY 1. TESTING LABORATORY TECHNICAL INFORMATION SPECIFIC ABSORPTION RATE (SAR) SAR MEASUREMENT SETUP...

CERTIFICATE OF COMPLIANCE R&D SAR EVALUATION

SAR TEST REPORT KIDS GPS WATCH. wonlex GW400S. Front of face: W/kg. Wrist: W/kg

CERTIFICATE OF COMPLIANCE R&D SAR EVALUATION

FCC SAR Test Report. STANDARD : 47 CFR Part 2 (2.1093) IEEE C OET Bulletin 65 Supplement C (Edition 01-01)

HAC Test Report for Telecoil IHDP56JX2

DECLARATION OF COMPLIANCE

CERTIFICATE OF COMPLIANCE SAR EVALUATION

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Dosimetric Assessment Test Report

Accredited testing laboratory. DAR registration number: TTI-P-G 166/98

DECLARATION OF COMPLIANCE SAR ASSESSMENT Part 1 of 2

COMPANY Floor. Floor IEEEE 1528: 2013

DIRECTORY 1. TESTING LABORATORY SPECIFIC ABSORPTION RATE (SAR) SAR MEASUREMENT SETUP TISSUE SIMULATING LIQUIDS...

: 1400 West Stanford Ranch Road Suite 200 Rocklin CA USA

SPORTON INTERTIONAL INC. EMC & Wireless Communications Laboratory No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.O.C.

SAR TEST REPORT. ADDRESS: Administration Building, Huawei Base, Bantian, Longgang District, Shenzhen P.R.C.

FCC SAR Compliance Test Report

SAR TEST REPORT. Report No.: Product: Trade Name: Brand Name: \ Model No.: FCC ID: Applicant:

TEST REPORT. Test Report No.: / B. Test Standard/s

FCC SAR SPORTON APPLICANT EQUIPMENT MODEL NAME : EM113-MV : FCC 47 CFR STANDARD IEEE Name: The product was (KUNSHAN) INC.

TEST REPORT FROM RFI GLOBAL SERVICES LTD

CERTIFICATE OF COMPLIANCE SAR EVALUATION

Nokia. SAR Report. Applicant: FCC_RM-948_ Test report no.: Nokia Corporation. Number of pages: Client: Beijing

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

FCC SAR EVALUATION REPORT

: DELL Inc. : Tablet PC : Dell : T01C : T01C0011 : E2K-T01C001 APPLICANT EQUIPMENT BRAND NAME MODEL NAME TYPE NAME STANDARD SPORTON.

REVISION HISTORY. Original Test Report No.: H-B. Revision Test report No. Date Page Contents

Report No:082186R-HPUSP09V01. SAR Test Report. : Eee PC

CERTIFICATE OF COMPLIANCE SAR EVALUATION

SAR EVALUATION REPORT. FCC 47 CFR IEEE Std For Tablet Device. FCC ID: BCGA1701 Model Name: A1701

portt n) Co., Ltd. Complia Attestat ance(sh henzhen 9HH01 Rep ON: This rep CAUTIO port shall not n be repro laborato o context.

FCC SAR Test Report. : ASUSTek COMPUTER INC. : 4F, No. 150, LI-TE Rd., PEITOU, TAIPEI 112, TAIWAN

SPORTON. Test Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME FCC ID STANDARD. y Co., Ltd. : O57TB2X30 IEEE sample has been INTERNATIONAL

2AIEBTTS FCC ID. Bluetooth. intercom EJEAS BRAND MODEL NAME CLIENT DATE OF ISSUE. June 6,2016 V1.0 REPORT VERSION CAUTION:

SAR TEST REPORT. No.I17N0257- HAC RF. For. Reliance Communications, LLC. GSM/CDMA/WCDMA/LTE mobile phone. Model Name: RC555L. With

ANNEX TO RESOLUTION No. 533, OF SEPTEMBER 10 th 2009.

SAR Test Report. Report No.: AGC FH01. FCC Oet65 Supplement C June 2001 IEEE Std CFR

FCC SAR TEST REPORT. Report No: STS H01. Issued for MOVILES INTELIGENTES S.A. Blvd Vista Hermosa zona 15, VH 1. feature mobile phone

Report Ref.:SZ S02. SAR Testing Report. Mobile phone radiation battery patch. Economic and Trade Limited. Issuer: Wu Xuewen

SAR TEST REPORT. Test Report No. : H

Group. Incorporated IC: 202D Tested For ICOM. Japan Osaka, In accordance with. UltraTech. Tested by: Natashaa Kee Test Dates:

Hearing Aid Compatibility (HAC) RF Emissions Test Report

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

STANDARD : FCC 47 CFR Part 2 (2.1093) ANSI/IEEE C IEEE

FCC SAR Report. Model No. : 001 Brand Name : Snapchat

SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.O.C.

Transcription:

RE052-12-106218-1/A Ed. 0 SAR TEST REPORT According to the standard: EN 62209-1: 2006 Equipment under test: Antenna patch for mobile phone FAZUP Tested with an Apple iphone 5 (A1429) Company: - DISTRIBUTION: Messrs SAMAKH Company: - Number of pages: 19 Ed. Date Modified page(s) 0 Nov. 30, 2012 Written by / Technical verification Name Visa Quality Approval Name Visa Creation Emmanuel TOUTAIN Gilles HYAUMET Duplication of this test report is only permitted for an integral photographic facsimile. It includes the number of pages referenced here above. This document is the result of testing a specimen or a sample of the product submitted. It does not imply an assessment of the conformity of the whole production of the tested sample.

RE052-12-106218-1/A Ed. 0 PAGE : 2/19 EQUIPMENT UNDER TEST: Antenna patch for mobile phone Reference 1: FAZUP (antenna patch) Serial number: - Reference 2: Apple iphone 5 Model A1429 (mobile phone) Serial number: IMEI 013350006699429 MANUFACTURER: - APPLICANT: Company: - Address: Mr. Antoine SAMAKH and Mr. Mathieu SAMAKH FRANCE Contact person: Person(s) present(s) during the test: Mr. Antoine SAMAKH and Mr. Mathieu SAMAKH Mr. Antoine SAMAKH and Mr. Mathieu SAMAKH DATE(S) OF TEST(S): November 12, 13 and 16, 2012 TEST SITE: EMITECH laboratory at Le Mans (72) - FRANCE TEST(S) OPERATOR(S): Emmanuel TOUTAIN

RE052-12-106218-1/A Ed. 0 PAGE : 3/19 SUMMARY 1. INTRODUCTION 4 2. REFERENCE DOCUMENTS 4 3. PRESENTATION OF EQUIPMENT FOR TESTING PURPOSES 4 4. TESTS RESULTS SUMMARY 6 5. ENVIRONNEMENTAL CONDITIONS 7 6. EQUIPMENT USED FOR THE TESTING 7 7. MEASUREMENT RESULTS 8 8. GRAPHICAL REPRESENTATIONS OF THE COARSE SCAN 8 9. PHOTOGRAPH OF THE MOBILE PHONE UNDER TEST 13 10. MEASUREMENT UNCERTAINTY 14 11. SPATIAL PEAK SAR EVALUATION 15 12. TEST CONDITIONS 16 13. MEASUREMENT SYSTEM DESCRIPTION 16 14. LIQUID MEASUREMENT: TEST CONDITIONS & RESULTS 17 15. SYSTEM VALIDATION: TEST CONDITIONS & RESULTS 17

RE052-12-106218-1/A Ed. 0 PAGE : 4/19 1. INTRODUCTION In this test report, Specific Absorption Rate (SAR) measurements for the mobile phone Apple iphone 5 Model A1429 used with the antenna patch FAZUP are presented. The measurements were made according to the EN 62209-1 standard for evaluating the SAR level attenuation provided by the patch. Full SAR testing according to the EN 62209-1 standard is not required by the applicant; the testing program is described in 7. MEASUREMENT RESULTS. 2. REFERENCE DOCUMENTS The reference documents referred throughout this report are listed below. These reference documents are applicable to the entire report, although extensions (version, date and amendment) are not repeated. Reference Document title Date EN 62209-1 Human exposure to radio frequency fields from hand-held and body- 2006 mounted wireless communication devices Human models, instrumentation, and procedures Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz) (IEC 62209-1:2005). IEC 62209-1 Human exposure to radio frequency fields from hand-held and bodymounted wireless communication devices Human models, instrumentation, and procedures Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz). 2005 3. PRESENTATION OF EQUIPMENT FOR TESTING PURPOSES The photographs of the mobile phone Apple iphone 5 Model A1429 and the antenna patch FAZUP are shown in Fig. 1. The standard used by the mobile phone for this test is the GSM in the 900MHz and 1800MHz frequency band, the antenna is integrated. The antenna patch FAZUP was placed on the rear side of the mobile phone by the applicant.

RE052-12-106218-1/A Ed. 0 PAGE : 5/19 FAZUP (antenna patch) Apple iphone 5 Model A1429 (mobile phone) Apple iphone 5 Model A1429 and FAZUP Mobile phone marking Fig. 1: Photographs of equipment under test

RE052-12-106218-1/A Ed. 0 PAGE : 6/19 4. TESTS RESULTS SUMMARY Configuration GSM900 Channel 038 897.6 MHz SAR level attenuation GSM1800 Channel 699 1747.6 MHz Apple iphone 5 Model A1429 + FAZUP 52.03% 75.61% This test report only relates to SAR measurements; radiated performances evaluation of the mobile phone with and without the protective device is not part of this report.

RE052-12-106218-1/A Ed. 0 PAGE : 7/19 5. ENVIRONNEMENTAL CONDITIONS Condition Liquid Temperature Ambient Temperature Measured Value See Graphical Representations See Graphical Representations 6. EQUIPMENT USED FOR THE TESTING Platform ID Platform Equipment Type Manufacturer Internal Number Software Version 1 BTS Simulator CMU200 Radio tester Rohde-Schwarz 7361 922 Thermometer Testo 6980 2 DASY4 DASY4 Software Speag 7321 V4.5 Build 19 ES3DV3 E-Field Probe Speag 9485 DAE3 Data acquisition Speag 7192 D900V2 Dipole 900MHz Speag 7194 D1800V2 Dipole 1800MHz Speag 7193 SAM Phantom Speag 7204 3 Liquid Measure HP85070C Software Hewlett-Packard - C1.01 HP8753D Network analyzer Hewlett-Packard 7216 HP85070C Dielectric probe Hewlett-Packard 7218 4 System 2024 Signal generator Marconi 7215 Validation ZHL42 Amplifier Mini-circuits 7209 PMC18-2 Power Supply Kikusui 7214 NRVS Power meter Rohde-Schwarz 7212 NRV-Z31 Probe power meter Rohde-Schwarz 7211 3877 Coupler Suhner 7208 RK100 Coupler MEB 7210 33-3-34 Attenuator Weinschel Engineering 7213 R411810124 Attenuator Radiall 7315 R411806124 909A 50 ohms load HP 7314 R404563000 50 ohms load Radiall 7313

RE052-12-106218-1/A Ed. 0 PAGE : 8/19 7. MEASUREMENT RESULTS The output power and frequency are controlled using a base station simulator. The mobile phone is set to transmit at its highest output peak power level. The mobile phone is test in the cheek position on right side of the phantom at the centre frequency of GSM900 and GSM1800 operating band with and without FAZUP. Measurement results for GSM900 (SAR values averaged over a mass of 10g): Configuration Phantom Position SAR 10g (W/kg) Channel 038 897.6 MHz Mobile phone without FAZUP Right Side Cheek 0.369 Mobile phone with FAZUP Right Side Cheek 0.177 Measurement results for GSM1800 (SAR values averaged over a mass of 10g): Configuration Phantom Position SAR 10g (W/kg) Channel 699 1747.6 MHz Mobile phone without FAZUP Right Side Cheek 0.529 Mobile phone with FAZUP Right Side Cheek 0.129 8. GRAPHICAL REPRESENTATIONS OF THE COARSE SCAN The graphical representations of the coarse scan are shown in Fig. 2 to Fig. 5.

RE052-12-106218-1/A Ed. 0 PAGE : 9/19 DUT: Apple iphone 5 (Model A1429) Communication System: E-GSM 900; Frequency: 897.6 MHz; Duty Cycle: 1:8.3 Medium parameters used: σ = 0.93 mho/m, ε r = 39.8; ρ = 1000 kg/m 3 Phantom section: Right Section Program Notes: Ambient temperature: 21.4 C, Liquid temperature: 19.4 C DASY4 Configuration: - Probe: ES3DV3 - SN3303; ConvF(5.97, 5.97, 5.97); Calibrated: 7/17/2012 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE3 Sn402; Calibrated: 3/9/2012 - Phantom: SAM 12; Type: QD; Serial: TP-1111 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145 Cheek Position - Middle/Area Scan (51x101x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (interpolated) = 0.513 mw/g Cheek Position - Middle/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 9.24 V/m; Power Drift = -0.083 db Peak SAR (extrapolated) = 0.663 W/kg SAR(1 g) = 0.503 mw/g; SAR(10 g) = 0.369 mw/g Maximum value of SAR (measured) = 0.532 mw/g 0 db = 0.532mW/g Fig. 2: SAR distribution for GSM900 of the mobile phone alone: channel 38 (897.6 MHz), cheek position, right side

RE052-12-106218-1/A Ed. 0 PAGE : 10/19 DUT: Apple iphone 5 (Model A1429) + FAZUP Communication System: E-GSM 900; Frequency: 897.6 MHz; Duty Cycle: 1:8.3 Medium parameters used: σ = 0.93 mho/m, ε r = 39.8; ρ = 1000 kg/m 3 Phantom section: Right Section Program Notes: Ambient temperature: 21.2 C, Liquid temperature: 19.5 C DASY4 Configuration: - Probe: ES3DV3 - SN3303; ConvF(5.97, 5.97, 5.97); Calibrated: 7/17/2012 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE3 Sn402; Calibrated: 3/9/2012 - Phantom: SAM 12; Type: QD; Serial: TP-1111 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145 Cheek Position - Middle/Area Scan (51x101x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (interpolated) = 0.281 mw/g Cheek Position - Middle/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 6.48 V/m; Power Drift = 0.109 db Peak SAR (extrapolated) = 0.363 W/kg SAR(1 g) = 0.261 mw/g; SAR(10 g) = 0.177 mw/g Maximum value of SAR (measured) = 0.279 mw/g 0 db = 0.279mW/g Fig. 3: SAR distribution for GSM900 of the mobile phone with FAZUP: channel 38 (897.6 MHz), cheek position, right side

RE052-12-106218-1/A Ed. 0 PAGE : 11/19 DUT: Apple iphone 5 (Model A1429) Communication System: GSM 1800; Frequency: 1747.6 MHz; Duty Cycle: 1:8.3 Medium parameters used: σ = 1.36 mho/m, ε r = 38.3; ρ = 1000 kg/m 3 Phantom section: Right Section Program Notes: Ambient temperature: 20.6 C, Liquid temperature: 19.6 C DASY4 Configuration: - Probe: ES3DV3 - SN3303; ConvF(5.22, 5.22, 5.22); Calibrated: 7/17/2012 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE3 Sn402; Calibrated: 3/9/2012 - Phantom: SAM 12; Type: QD; Serial: TP-1111 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145 Cheek Position - Middle/Area Scan (51x91x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (interpolated) = 0.929 mw/g Cheek Position - Middle/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 7.56 V/m; Power Drift = 0.037 db Peak SAR (extrapolated) = 1.22 W/kg SAR(1 g) = 0.845 mw/g; SAR(10 g) = 0.529 mw/g Maximum value of SAR (measured) = 0.920 mw/g 0 db = 0.920mW/g Fig. 4: SAR distribution for GSM1800 of the mobile phone alone: channel 699 (1747.6MHz), cheek position, right side

RE052-12-106218-1/A Ed. 0 PAGE : 12/19 DUT: Apple iphone 5 (Model A1429) + FAZUP Communication System: GSM 1800; Frequency: 1747.6 MHz; Duty Cycle: 1:8.3 Medium parameters used: σ = 1.36 mho/m, ε r = 38.3; ρ = 1000 kg/m 3 Phantom section: Right Section Program Notes: Ambient temperature: 20.8 C, Liquid temperature: 19.6 C DASY4 Configuration: - Probe: ES3DV3 - SN3303; ConvF(5.22, 5.22, 5.22); Calibrated: 7/17/2012 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE3 Sn402; Calibrated: 3/9/2012 - Phantom: SAM 12; Type: QD; Serial: TP-1111 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145 Cheek Position - Middle/Area Scan (51x91x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (interpolated) = 0.236 mw/g Cheek Position - Middle/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.78 V/m; Power Drift = 0.028 db Peak SAR (extrapolated) = 0.312 W/kg SAR(1 g) = 0.211 mw/g; SAR(10 g) = 0.129 mw/g Maximum value of SAR (measured) = 0.232 mw/g 0 db = 0.232mW/g Fig. 5: SAR distribution for GSM1800 of the mobile phone with FAZUP: channel 699 (1747.6MHz), cheek position, right side

RE052-12-106218-1/A Ed. 0 PAGE : 13/19 9. PHOTOGRAPH OF THE MOBILE PHONE UNDER TEST The photograph of the mobile phone under test is shown in Fig. 6. Fig. 6: Mobile phone in cheek position on right side

RE052-12-106218-1/A Ed. 0 PAGE : 14/19 10. MEASUREMENT UNCERTAINTY The expanded uncertainty with a confidence interval of 95 % shall not exceed 30 % for averaged SAR values in the range from 0.4 to 10 W/kg. The uncertainty of the measurements was evaluated according to the EN 62209-1 and determined by Schmid & Partner Engineering AG. The expanded uncertainty is ± 21.4 %. ERROR SOURCES Uncertainty Value (%) Probability Distribution Divisor Ci Standard Uncertainty (%) Measurement System Probe Calibration ± 5.9 Normal 1 1 ± 5.9 Axial Isotropy ± 4.7 Rectangular 3 0.7 ± 1.9 Hemispherical Isotropy ± 9.6 Rectangular 3 0.7 ± 3.9 Boundary Effect ± 1.0 Rectangular 3 1 ± 0.6 Linearity ± 4.7 Rectangular 3 1 ± 2.7 Detection Limits ± 1.0 Rectangular 3 1 ± 0.6 Readout Electronics ± 0.3 Normal 1 1 ± 0.3 Response Time ± 0.8 Rectangular 3 1 ± 0.5 Integration Time ± 2.6 Rectangular 3 1 ± 1.5 RF Ambient Conditions-Noise ± 3.0 Rectangular 3 1 ± 1.7 RF Ambient Conditions-Reflections ± 3.0 Rectangular 3 1 ± 1.7 Probe Positioner Mechanical Restrictions ± 0.4 Rectangular 3 1 ± 0.2 Probe Positioning with respect to Phantom ± 2.9 Rectangular 3 1 ± 1.7 Shell Post-Processing ± 1.0 Rectangular 3 1 ± 0.6 Test Sample Related Test Sample Positioning ± 2.9 Normal 1 1 ± 2.9 Device Holder Uncertainty ± 3.6 Normal 1 1 ± 3.6 Drift of Output Power ± 5.0 Rectangular 3 1 ± 2.9 Phantom and Set-Up Phantom Uncertainty (shape and thickness tolerances) ± 4.0 Rectangular 3 1 ± 2.3 Liquid Conductivity (Target) ± 5.0 Rectangular 3 0.43 ± 1.2 Liquid Conductivity (Measurement) ± 2.5 Normal 1 0.43 ± 1.1 Liquid Permittivity (Target) ± 5.0 Rectangular 3 0.49 ± 1.4 Liquid Permittivity (Measurement) ± 2.5 Normal 1 0.49 ± 1.2 Combined standard uncertainty ± 10.7 Expanded uncertainty (confidence interval of 95%) ± 21.4

RE052-12-106218-1/A Ed. 0 PAGE : 15/19 11. SPATIAL PEAK SAR EVALUATION From Schmid & Partner Engineering AG, [DASY4 Manual, March 2003, Application Note: Spatial Peak SAR Evaluation]. Spatial Peak SAR The DASY4 software includes all numerical procedures necessary to evaluate the spatial peak SAR values. The spatial-peak SAR can be computed over any required mass. The base for the evaluation is a cube measurement in a volume of 30mm3 (7x7x7 points). The measured volume includes the 1g and 10g cubes with the highest averaged SAR values. For that purpose, the center of the measured volume is aligned to the interpolated peak SAR value of a previously performed area scan. The entire evaluation of the spatial peak values is performed within the postprocessing engine (SEMCAD). The system always gives the maximum values for the 1g and 10g cubes. The algorithm to find the cube with highest averaged SAR is divided into the following stages: 1. Extraction of the measured data (grid and values) from the Zoom Scan, 2. Calculation of the SAR value at every measurement point based on all stored data (A/D values and measurement parameters), 3. Generation of a high-resolution mesh within the measured volume, 4. Interpolation of all measured values from the measurement grid to the high-resolution grid, 5. Extrapolation of the entire 3-D field distribution to the phantom surface over the distance from sensor to surface, 6. Calculation of the averaged SAR within masses of 1g and 10g. Interpolation, Extrapolation and Detection of Maxima The probe is calibrated at the center of the dipole sensors which is located at 2.7mm away from the probe tip. During measurements, the dipole sensors are 4mm above the phantom surface. Both distances are included as parameters in the probe configuration file. The software always knows exactly how far away the measured point is from the surface. As the probe cannot directly measure at the surface, the values between the deepest measured point and the surface must be extrapolated. The interpolation, extrapolation and maximum search routines are all based on the modified Quadratic Shepard s method [Robert J. Renka, Multivariate Interpolation Of Large Sets Of Scattered Data, University of North Texas ACM Transactions on Mathematical Software, vol. 14, no. 2, June 1988, pp. 139-148.]. Averaging and Determination of Spatial Peak SAR The interpolated data is used to average the SAR over the 1g and 10g cubes by spatially discretizing the entire measured volume. The resolution of this spatial grid used to calculate the averaged SAR is 1mm or about 42875 interpolated points. The resulting volumes are defined as cubical volumes containing the appropriate tissue parameters that are centered at the location. The location is defined as the center of the incremental volume (voxel).

RE052-12-106218-1/A Ed. 0 PAGE : 16/19 12. TEST CONDITIONS The equipment is controlled during test using platform n 1 (BTS simulator) referenced in paragraph 6 of this test report. The following test conditions are given for information; the maximum output powers were not measured. Standard: GSM (900 & 1800 MHz) Crest factor: 8 Modulation: GMSK Traffic Channel: GSM 900: middle channel = 38 GSM 1800: middle channel = 699 Maximum output power: GSM 900 Class 4: Tx level 5 = 33 dbm (± 2dB) GSM 1800 Class 1: Tx level 0 = 30 dbm (± 2dB) Note: The tested EUT could contain an antenna diversity technology, as MIMO or MISO. The control of the antenna s scheme has not been provided by the applicant. Thus, the radiated performances of the EUT are dependent on the test set-up; an antenna diversity control could lead to different results from those reported in this test report. 13. MEASUREMENT SYSTEM DESCRIPTION The automated near-field scanning system Dosimetric Assessment System DASY4 from Schmid & Partner Engineering AG was used. The measurement is performed using platform n 2 referenced in paragraph 6 ( Equipment used for the testing ) of this report. The system consists of a computer controlled, high precision robotics system, robot controller, extreme near-field probes and the phantom containing the liquid. The six axis robot precisely positions the probe at the points of maximum electromagnetic field. A device holder made of low-loss dielectric material is used to maintain the test position of the equipment under test against the phantom. The measurements were conducted in an RF controlled environment (i.e. anechoic room). Fig. 7 shows the system. Fig. 7: The measurement setup with equipment under test 14. LIQUID MEASUREMENT: TEST CONDITIONS & RESULTS

RE052-12-106218-1/A Ed. 0 PAGE : 17/19 The measurement is performed using platform n 3 referenced in paragraph 6 ( Equipment used for the testing ) of this report. The following ingredients (in % by weight) are theoretical and given for information. 900 MHz liquid: Sucrose 56.50 % De-ionised water 40.92 % NaCl salt 1.48 % - HEC 1.00 % - Bactericide 0.10 % 1800 MHz liquid: Diethylenglykol-monobutylether 44.92 % De-ionised water 54.90 % NaCl salt 0.18 % The dielectric parameters of the brain simulating liquid were controlled prior to assessment (contact probe method). Dielectric properties measured: Frequency (MHz) ε r Targeted value ε r Measured value σ (S/m) Targeted value σ (S/m) Measured value 880 41.5 ± 5 % 40.2 0.95 ± 5 % 0.92 895 41.5 ± 5 % 39.9 0.96 ± 5 % 0.93 900 41.5 ± 5 % 39.8 0.97 ± 5 % 0.93 915 41.5 ± 5 % 39.7 0.97 ± 5 % 0.94 1710 40.1 ± 5 % 38.4 1.34 ± 5 % 1.33 1750 40.1 ± 5 % 38.3 1.37 ± 5 % 1.36 1785 40.0 ± 5 % 38.1 1.39 ± 5 % 1.39 1800 40.0 ± 5 % 38.1 1.40 ± 5 % 1.41 Liquid temperature ( C) Ambient temperature ( C) 19.2 20.1 19.5 20.2 15. SYSTEM VALIDATION: TEST CONDITIONS & RESULTS The measurement is performed using platform n 4 referenced in paragraph 6 ( Equipment used for the testing ) of this report. Measurement conditions: The measurements were performed in the flat section of the SAM phantom filled with liquids simulating tissue. The validation dipole input power was 250mW. Prior to the assessment, the validation dipole were used to check whether the system was operating within its specification of ± 10 %. Measurement results: The results are hereafter below and shown in Fig. 8 and Fig. 9. Frequency (MHz) SAR 1g (W/kg) Targeted value SAR 1g (W/kg) Measured value 900 1.725 ± 10 % 1.72 1800 4.95 ± 10 % 5.01

RE052-12-106218-1/A Ed. 0 PAGE : 18/19 DUT: Dipole 900 MHz Communication System: CW; Frequency: 900 MHz; Duty Cycle: 1:1 Medium parameters used: σ = 0.93 mho/m, ε r = 39.8; ρ = 1000 kg/m 3 Phantom section: Flat Section Program Notes: Ambient temperature: 21.8 C, Liquid temperature: 20.1 C DASY4 Configuration: - Probe: ES3DV3 - SN3303; ConvF(5.97, 5.97, 5.97); Calibrated: 7/17/2012 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE3 Sn402; Calibrated: 3/9/2012 - Phantom: SAM 12; Type: QD; Serial: TP-1111 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145 d=15mm, Pin=250mW/Area Scan (61x81x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (interpolated) = 2.84 mw/g d=15mm, Pin=250mW/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 55.8 V/m; Power Drift = -0.031 db Peak SAR (extrapolated) = 4.11 W/kg SAR(1 g) = 2.68 mw/g; SAR(10 g) = 1.72 mw/g Maximum value of SAR (measured) = 2.91 mw/g 0 db = 2.91mW/g Fig. 8: 900 MHz validation result

RE052-12-106218-1/A Ed. 0 PAGE : 19/19 DUT: Dipole 1800 MHz Communication System: CW; Frequency: 1800 MHz; Duty Cycle: 1:1 Medium parameters used: σ = 1.41 mho/m, ε r = 38.1; ρ = 1000 kg/m 3 Phantom section: Flat Section Program Notes: Ambient temperature: 21.6 C, Liquid temperature: 19.9 C DASY4 Configuration: - Probe: ES3DV3 - SN3303; ConvF(5.22, 5.22, 5.22); Calibrated: 7/17/2012 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE3 Sn402; Calibrated: 3/9/2012 - Phantom: SAM 12; Type: QD; Serial: TP-1111 - Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 145 d=10mm, Pin=250mW/Area Scan (61x61x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (interpolated) = 11.3 mw/g d=10mm, Pin=250mW/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 89.2 V/m; Power Drift = -0.022 db Peak SAR (extrapolated) = 17.6 W/kg SAR(1 g) = 9.62 mw/g; SAR(10 g) = 5.01 mw/g Maximum value of SAR (measured) = 10.9 mw/g 0 db = 10.9mW/g Fig. 9: 1800 MHz validation result DDD End of report DDD