IS 244 Inuctive switches Dimensione rawing en 01-2010/11 50114422 20mm 10-30 V DC 150 Hz embee Plastic 40 x40mm cubical housing Connection via screw terminals Built-in short circuit protection, polarity reversal protection LED for switching state Tightening torque of the - fastening screws < 1.8Nm! - screw terminals < 1.0Nm! We reserve the right to make changes IS_244_E_en.fm IEC 60947... IEC 60947... ccessories: (available separately) U L US C LISTED IP 69K IP 67 ctive surface B Yellow inicator ioe C Green inicator ioe Electrical connection
IS 244 Specifications General specifications Type of installation Typ. operating range limit S n Operating range S a Electrical ata Operating voltage U 1) B Resiual ripple σ Output current I L Open-circuit current I 0 Resiual current I r Switching output/function Voltage rop U Hysteresis H of S r typ. 5% Repeatability of S r 10% 2) Timing Switching frequency f Delay before start-up Inicators Yellow LED (visible from 360 ) Mechanical ata IS 244-20E embee installation 20.0mm 0 16.2mm 10 30VDC 20% of U B 200m 20m 500μ /44 PNP transistor, make-contact + break-contact (NO + NC), /22 NPN transistor, make-contact + break-contact (NO + NC), 2V 150Hz 300ms switching state Housing ctive surface Weight (M12 plug/cable) Connection type Environmental ata mbient temperature -25 C +85 C Protection class IP 67, IP 69K Protective circuit 3) 1, 2 Stanars applie IEC/EN 60947-5-2 Electromagnetic compatibility IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 P, metal 60 x 60mm², Fe360 P approx. 225g M20 terminal compartment, wire cross section 2.5mm² 1) Observe the safety regulations an installation instructions regaring power supply an wiring; for UL applications: only for use in "Class 2" circuits acc. to NEC 2) For U B ambient temperature T a = 23 C ± 5 C 3) 1=polarity reversal protection, 2=short-circuit protection, for all outputs Typical approach curve: raial axial Real istance Switching point Hysteresis ir 8kV (ESD) 10V/m (RFI) 2kV (Burst) Tables Reuction factors: for S n = 40.0mm Steel Fe360 1 Copper 0.31 luminum 0.33 Brass 0.38 Stainless steel 0.74 Mounting Embee installation: typ. 3S n S n : active surface Ferromagnetic an non-ferromagnetic materials 20 0 40 5 50 Remarks pprove purpose: The inuctive switches are electronic sensors for the inuctive, contactless etection of objects. This prouct may only be use by qualifie personnel an must only be use for the approve purpose. This sensor is not a safety sensor an is not to be use for the protection of persons. Diameter of the active surface x [%] Orer guie The sensors liste here are preferre types; current information at Leuze website. Designation Part No. S n = 20mm IS 244 PP/44-20E-TB.4 50114213 IS 244 PP/22-20E-TB.4 50114211
ISS 244 (short construction) Inuctive switches Dimensione rawing en 01-2010/11 50114425 40mm 10-30 V DC 150 Hz non-embee Short 40 x40mm cubical housing Light plastic housing Built-in short circuit protection, polarity reversal protection LED for switching state Tightening torque of the fastening screws < 1.8Nm! We reserve the right to make changes ISS_244_N_en.fm IEC 60947... IEC 60947... ccessories: (available separately) U L US C LISTED IP 69K IP 67 M12 connectors (KD ) Reay-mae cables (K-D ) ctive surface B Yellow inicator ioe C Green inicator ioe Electrical connection
ISS 244 (short construction) Specifications General specifications Type of installation Typ. operating range limit S n Operating range S a Electrical ata Operating voltage U 1) B Resiual ripple σ Output current I L Open-circuit current I 0 Resiual current I r Switching output/function Voltage rop U Hysteresis H of S r typ. 5% Repeatability of S r 10% 2) Timing Switching frequency f Delay before start-up Inicators Yellow LED (visible from 360 ) Mechanical ata ISS 244-40N non-embee installation 40.0mm 0 32.4mm 10 30VDC 20% of U B 200m 20m 500μ /44 PNP transistor, make-contact + break-contact (NO + NC), /22 NPN transistor, make-contact + break-contact (NO + NC), 2V 150Hz 300ms switching state Housing P 120 x 120mm², Fe360 ctive surface P Weight (M12 plug/cable) approx. 130g Connection type M12 connector Environmental ata mbient temperature -25 C +85 C Protection class IP 67, IP 69K Protective circuit 3) 1, 2 Stanars applie IEC/EN 60947-5-2 Electromagnetic compatibility IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 1) Observe the safety regulations an installation instructions regaring power supply an wiring; for UL applications: only for use in "Class 2" circuits acc. to NEC 2) For U B ambient temperature T a = 23 C ± 5 C 3) 1=polarity reversal protection, 2=short-circuit protection, for all outputs Typical approach curve: raial axial Real istance Switching point Hysteresis ir 8kV (ESD) 10V/m (RFI) 2kV (Burst) Tables Reuction factors: for S n = 40.0mm Steel Fe360 1 Copper 0.30 luminum 0.31 Brass 0.39 Stainless steel 0.74 Mounting Non-embee installation: typ. 3S n S n : active surface Ferromagnetic an non-ferromagnetic materials 40 40 160 42 300 Remarks pprove purpose: The inuctive switches are electronic sensors for the inuctive, contactless etection of objects. This prouct may only be use by qualifie personnel an must only be use for the approve purpose. This sensor is not a safety sensor an is not to be use for the protection of persons. Diameter of the active surface x [%] Orer guie The sensors liste here are preferre types; current information at Leuze website. Designation Part No. S n = 40mm ISS 244 PP/44-40N-S12 50114218 ISS 244 PP/22-40N-S12 50114216
ISS 244 (short construction) Inuctive switches Dimensione rawing en 01-2010/11 50114424 20mm 10-30 V DC 150 Hz embee Short 40 x40mm cubical housing Light plastic housing Built-in short circuit protection, polarity reversal protection LED for switching state Tightening torque of the fastening screws < 1.8Nm! We reserve the right to make changes ISS_244_E_en.fm IEC 60947... IEC 60947... ccessories: (available separately) U L US C LISTED IP 69K IP 67 M12 connectors (KD ) Reay-mae cables (K-D ) ctive surface B Yellow inicator ioe C Green inicator ioe Electrical connection
ISS 244 (short construction) Specifications General specifications Type of installation Typ. operating range limit S n Operating range S a Electrical ata Operating voltage U 1) B Resiual ripple σ Output current I L Open-circuit current I 0 Resiual current I r Switching output/function Voltage rop U Hysteresis H of S r typ. 5% Repeatability of S r 10% 2) Timing Switching frequency f Delay before start-up Inicators Yellow LED (visible from 360 ) Mechanical ata ISS 244-20E embee installation 20.0mm 0 16.2mm 10 30VDC 20% of U B 200m 20m 500μ /44 PNP transistor, make-contact + break-contact (NO + NC), /22 NPN transistor, make-contact + break-contact (NO + NC), 2V 150Hz 300ms awitching state Housing P 60 x 60mm², Fe360 ctive surface P Weight (M12 plug/cable) approx. 130g Connection type M12 connector Environmental ata mbient temperature -25 C +85 C Protection class IP 67, IP 69K Protective circuit 3) 1, 2 Stanars applie IEC/EN 60947-5-2 Electromagnetic compatibility IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 1) Observe the safety regulations an installation instructions regaring power supply an wiring; for UL applications: only for use in "Class 2" circuits acc. to NEC 2) For U B ambient temperature T a = 23 C ± 5 C 3) 1=polarity reversal protection, 2=short-circuit protection, for all outputs Typical approach curve: raial axial Real istance Switching point Hysteresis ir 8kV (ESD) 10V/m (RFI) 2kV (Burst) Tables Reuction factors: for S n = 20.0mm Steel Fe360 1 Copper 0.31 luminum 0.33 Brass 0.41 Stainless steel 0.74 Mounting Embee installation: typ. 3S n S n : active surface Ferromagnetic an non-ferromagnetic materials 20 0 40 10 70 Remarks pprove purpose: The inuctive switches are electronic sensors for the inuctive, contactless etection of objects. This prouct may only be use by qualifie personnel an must only be use for the approve purpose. This sensor is not a safety sensor an is not to be use for the protection of persons. Diameter of the active surface x [%] Orer guie The sensors liste here are preferre types; current information at Leuze website. Designation Part No. S n = 20mm ISS 244 PP/44-20E-S12 50114217 ISS 244 PP/22-20E-S12 50114215
IS 244 Inuctive switches Dimensione rawing en 01-2010/11 50114423 40mm 10-30 V DC 150 Hz non-embee Plastic 40 x40mm cubical housing Connection via screw terminals Built-in short circuit protection, polarity reversal protection LED for switching state Tightening torque of the - fastening screws < 1.8Nm! - screw terminals < 1.0Nm! We reserve the right to make changes IS_244_N_en.fm IEC 60947... IEC 60947... ccessories: (available separately) U L US C LISTED IP 69K IP 67 ctive surface B Yellow inicator ioe C Green inicator ioe Electrical connection
IS 244 Specifications General specifications Type of installation Typ. operating range limit S n Operating range S a Electrical ata Operating voltage U 1) B Resiual ripple σ Output current I L Open-circuit current I 0 Resiual current I r Switching output/function Voltage rop U Hysteresis H of S r typ. 5% Repeatability of S r 10% 2) Timing Switching frequency f Delay before start-up Inicators Yellow LED (visible from 360 ) Mechanical ata IS 244-40N non-embee installation 40.0mm 0 32.4mm 10 30VDC 20% of U B 200m 20m 500μ /44 PNP transistor, make-contact + break-contact (NO + NC), /22 NPN transistor, make-contact + break-contact (NO + NC), 2V 150Hz 300ms switching state Housing ctive surface Weight (M12 plug/cable) Connection type Environmental ata mbient temperature -25 C +85 C Protection class IP 67, IP 69K Protective circuit 3) 1, 2 Stanars applie IEC/EN 60947-5-2 Electromagnetic compatibility IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 P, metal 120 x 120mm², Fe360 P approx. 225g M20 terminal compartment, wire cross section 2.5mm² 1) Observe the safety regulations an installation instructions regaring power supply an wiring; for UL applications: only for use in "Class 2" circuits acc. to NEC 2) For U B ambient temperature T a = 23 C ± 5 C 3) 1=polarity reversal protection, 2=short-circuit protection, for all outputs Typical approach curve: raial axial Real istance Switching point Hysteresis ir 8kV (ESD) 10V/m (RFI) 2kV (Burst) Tables Reuction factors: for S n = 40.0mm Steel Fe360 1 Copper 0.30 luminum 0.31 Brass 0.39 Stainless steel 0.74 Mounting Non-embee installation: typ. 3S n S n : active surface Ferromagnetic an non-ferromagnetic materials 40 40 160 42 300 Remarks pprove purpose: The inuctive switches are electronic sensors for the inuctive, contactless etection of objects. This prouct may only be use by qualifie personnel an must only be use for the approve purpose. This sensor is not a safety sensor an is not to be use for the protection of persons. Diameter of the active surface x [%] Orer guie The sensors liste here are preferre types; current information at Leuze website. Designation Part No. S n = 40mm IS 244 PP/44-40N-TB.4 50114214 IS 244 PP/22-40N-TB.4 50114212