LCR METER Model:

Similar documents
LCR METER Model:

LCR METER OPERATION MANUAL. Model : LCR Hz 120 Hz 1 KHz 10 KHz 100 KHz, Precision

Page 1 of IR Port 5 External power port 6 Calibration button port 7 DUT + jack 8 DUT - jack 9 Shielding grounding jack

AMМ-3320 Multi-function LCR USER`S MANUAL

AMM-3035 User s Manual

Mini Clamp Meter Model:

Model: &

Digital Multimeter, Pen Type

DIGITAL MULTIMETER AUTORANGING

Digital Clamp Meter Model: &

Passive Component LCR Meter

MODEL: D03128 CLAMP METER

True RMS Digital Multimeter Model:

Passive Component LCR Meter

Passive Component LCR Meter

Elma 6400 LCR Meter. English 31 EAN: riešenia na presné meranie

AC/DC CLAMP METER USER S MANUAL

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

U1730C Series Handheld LCR Meters

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Agilent U1731C, U1732C, and U1733C Handheld LCR Meter

Pocket Size Digital Multimeter Models: and

Models 885 & 886 LCR METER OPERATING MANUAL

Frequency up to 100 khz

OPERATION MANUAL. Multi-Function LCR LIST OF PRODUCTS MODEL KM 520B

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

DVM1190 DIGITAL MULTIMETER

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Bench LCR Meter Model 891

Benchtop LCR Meter. Model Tenma Test Equipment 405 S. Pioneer Blvd. Springboro, OH

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

UT207A/208A/209A Operating Manual. Table of Contents

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

ProfiScale MULTI Multimeter

Digital Multimeter with Backlight

DCM730. Digital Clamp Meter User s Manual

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

R/C SMD Tweezers Multimeter Model RC200

The Meter Structure The Figure 2-1 shows the Meter structure.

KMD-S04 Multímetro de bolsillo

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

3B SCIENTIFIC PHYSICS

CONTENTS MS2033A. 1.Introduction Safety Information...01

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Pocket Size Digital Multimeter with USB Model: A & A

Agilent U1730C Series Handheld LCR Meters

SMART TWEEZERS Model ST-1 User s Manual Version 1.0

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

User Manual. All rights reserved. Specifications are subject to change without notice.

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

Micro-Ohmmeter Model UM200

MS2109A AC/DC Clamp Meter. User Manual. Contents

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Model UT10A: OPERATING MANUAL Table of Contents (1)

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

DM-45 Digital Multimeter

OPERATOR S INSTRUCTION MANUAL

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

NOTE: Fully read and understand this manual before using this Digital Multimeter.

User Manual. All rights reserved. Specifications are subject to change without notice.

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

400Amp True RMS AC/DC Clamp Meter Model EX613

UT232. Operating Manual. Digital Power Clamp Meter

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

Dawson DDM190. Digital Multimeter User s Manual

Keysight Technologies U1730C Series Handheld LCR Meters Take your expectations higher with the latest LCR meters. Data Sheet

AUTO-SCAN Pen R/C/D Meter for SMD AX-507B USER S MANUAL

DIGIT & POINTER MULTIMETER

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

500 khz/1 MHz LCR Meter

MS8223A. CAT.IIi 600 V

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

The Keysight Technologies, Inc. U1730C Series handheld LCR meters allow you to measure at frequencies as high as 100 khz a capability typically found

DDM350 Pen-Type Digital Multimeter User s Manual

Model UT511 OPERATING MANUAL

312, 316, 318. Clamp Meter. Users Manual

User Manual Digital Multimeter. model no.: MSR-U1000

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Multifunction Digital

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

Handheld Digital Multimeter

Model UT233 OPERATING MANUAL

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

DIGITAL MULTIMETER INSTRUCTION MANUAL

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Lab 3: AC Low pass filters (version 1.3)

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Transcription:

LCR METER Model: 72-10465 1

CONTENTS Page Number Details 3 Important Safety Information 3 Measurement Range & Accuracy 3 Ambient Conditions 4 Features 4 Impedance Explanation 4 Measurement Mode 5 LCD Description 5 Acronym Definitions 5 Product Overview 6 Operation - Automatic Measurement 6 Data Hold 6 Measurement Parameter Under L/C/R Mode 6 Measurement Frequency 7 REL% Measurement 7 Sorting Measurement 8 Calibration Function 8 PC Communication 9 Backlight 9 Auto Power Off 9 Selection of Serial/Parallel Mode 9 Inductance Measurement 9 Capacitance Measurement 10 Resistance Measurement 10 DCR Measurement 10 PC Communication Protocol 10 Technical Indicators 13 Battery Replacement 14 Maintenance WHAT S INCLUDED One LCR meter One user manual One USB adaptor Short circuit test piece Short circuit adaptor One software disc One tweezer probe 2

Please read these instructions carefully before use and retain for future reference. IMPORTANT SAFETY INFORMATION When using electrical appliances basic safety precautions should always be followed. Do not use the meter in environments exposed to explosive gas, vapour or dust, in direct sunlight or high radiation. There are no user serviceable parts in this product. Refer all servicing to qualified personnel. Turn off all the circuit power and discharge completely all capacitors before measuring in-line components. Measurement terminals, capacitors and other live components must be discharged before being measured. There are two power supplies available for the meter: 9V battery and USB powered. If the USB port is connected to the PC, the meter is USB-powered and will communicate with the PC for data collection. MEASUREMENT RANGE & ACCURACY L: 20mH - 2000H best accuracy: (0.5% + 5) C: 200pF - 20µF best accuracy: (0.5% + 5) R: 20Ω - 200MΩ best accuracy: (0.3% + 5) Impedance/ Frequency DCR 100/120Hz 1kHz 10kHz 100kHz 0.1-1 1.0% 1.0% 1.0% 1.0% 1.0% 1-10 0.5% 0.5% 0.5% 0.5% 0.5% 10-100k 0.3% 0.3% 0.3% 0.5% 0.3% 100k-1M 0.5% 0.5% 0.5% 1.0% 1M-20M 1.0% 1.0% 1.0% 20M-200M 2.0% 2.0% 5.0% Remark D 0.1 Note: Multiply by 1+D² if D exceeds 0.1 Formula to convert capacitance to impedance: Zᶜ = 1/2πfC Formula to convert inductance to impedance: Zᶫ = 2πfL AMBIENT CONDITIONS Altitude: <2000 metres Storage humidity: 75% RH Operating environment: 0 C~40 C Storage environment: -20 C~50 C 3

FEATURES Main display: 19999 count. Secondary display: 1999 count. Measurement frequency: 100Hz/120Hz/1kHz/10kHz/100kHz. Measurement voltage: 0.6Vrms. Output impedance: 120Ω. Basic accuracy: 0.5%. LCR automatic identification/manual measurement. DC resistance (DCR) measurement. Auto calibration. Auto power off. Relative measurement and sorting function. Communicates with PC using mini-usb interface to acquire, analyse and collect data. IMPEDANCE EXPLANATION Impedance is compromised of two base components Resistance and Reactance. This LCR meter is capable of measuring both Resistance and Reactance. Reactance varies in proportion to the frequency of the AC circuit. Impedance forms an imaginary vector comprised of Resistance R (real) and Reactance X (imaginary) with Impedance Z=R+jX, which can also be represented by amplitude Z and phase angle θ, which can be seen in the diagram. If the phase angle θ > 0, the reactance is inductive in nature, if θ < 0 the reactance is capacitive in nature. MEASUREMENT MODE Impedance can be measured in serial or parallel mode. Under parallel mode, impedance Z can be expressed in relation with the admittance Y and Y=G+jB. G is conductance and is B admittance. Serial Measurement Rˢ: Serial mode of resistance Xˢ: Serial mode of reactance Cˢ: Serial mode of capacitance Lˢ: Serial mode of inductance Rˢ Z = Rˢ + jxˢ jxˢ 4

Parallel Measurement Rᵖ: Parallel mode of resistance Xᵖ: Parallel mode of reactance Cᵖ: Parallel mode of capacitance Lᵖ: Parallel mode of inductance Rᵖ jxᵖ Y = 1/Z = 1/Rᵖ + 1/jXᵖ = G + jb LCD DESCRIPTION 1. USB communication 2. Open/short calibration 3. Auto power off 4. Relative measurement 5. Main display 6. Secondary display 7. Analogue bar 8. Sorting tolerance mode 9. Data hold 7) ACRONYM DEFINITIONS 1. LCR: Automatic identification mode 2. Lᵖ: Parallel measurement mode for inductance 3. Lˢ: Serial measurement mode for inductance 4. Cᵖ: Parallel measurement mode for capacitance 5. Cˢ: Serial measurement mode for capacitance 6. Rᵖ: Parallel measurement mode for resistance 7. Rˢ: Serial measurement mode for resistance 8. DCR: DC resistance measurement mode 9. D: Dissipation factor 10. Q: Quality factor 11. θ: Phase angle 12. ESR: Equivalent serial resistance 13. EPR: Equivalent parallel resistance 14. DUT: Device under test 15. Short press (<1 second), long press (>2 seconds): indicating the time to press a button. PRODUCT OVERVIEW 1. LCD 2. Frequency/sorting button 3. Open/short calibration button 4. Power on/off button 5. USB communication button 6. D/Q/θ selection button 7. Relative button 8. Input terminals 9. Guard terminals 10. Serial/parallel selection button 11. L/C/R function button 12. Enter/hold button 13. Sorting setup button 5

OPERATION - AUTOMATIC MEASUREMENT Once the meter is switched on, it defaults to AUTO LCR mode, at the frequency of 1kHz. In auto mode, the meter can automatically check the impedance characteristics of a tested object and then select L, C or R main parameter, its associated secondary parameter and the correct serial/parallel mode accordingly. Correspondence between the main and secondary parameter under auto mode: - Capacitance (C) - Dissipation (D) - Inductance (L) - Quality Factor (Q) - Resistance (R) - Phase Angle (θ) Under auto measurement mode, serial/parallel mode is determined based on the impedance of the tested object. The parallel mode is selected if the impedance is greater than 10kΩ. The serial mode is selected if the impedance is less than 10kΩ. DATA HOLD Press and hold the HOLD button to freeze the data during measurement. Press again to exit and return to normal measurement. MEASUREMENT PARAMETER UNDER L/C/R MODE Select the corresponding parameters under manual L/C/R mode. Selection of main parameter: Default status is AUTO LCR once powered on. Select FUNC to select parameters of: AUTO LCR AUTO L AUTO C AUTO R DCR AUTO LCR. Selection of secondary parameter: After a main parameter has been selected, press SER/PAL to switch between serial and parallel mode, Press D/Q/θ to select D, Q, θ, ESR ( ESR will show if under serial mode and likewise Rp if parallel mode is selected). Under AUTO R or AUTO DCR, the secondary parameter will be negligible. Notes: When measuring capacitance <5pF under AUTO LCR mode, Rᵖ will show on the secondary display instead of Dissipation factor (D). Some secondary parameters will not show on the LCD even if you have accessed AUTO R, AUTO DCR or AUTO LCR mode. MEASUREMENT FREQUENCY This model can provide five frequency testing points: 100Hz/120Hz/1kHz/10kHz/100kHz. Default frequency is 1kHz, although the user can press FREQ to select: 1kHZ 10kHz 100kHz 100Hz 120Hz 1kHz. Note: DC impedance is measured under AUTO DCR mode and measurement frequency can be neglected. 6

REL% MEASUREMENT REL% mode measures % deviation between two components. The measured value of the tested object shows on the main display, with the % value on the secondary display. Set the main display value as the nominal reference. % display range: -99%~99.9%. % calculation: REL%=(Dᶜᵘʳ-Dʳᵉᶠ)/Dʳᵉᶠ* 100%. Dᶜᵘʳ: main display value of tested object. Dʳᵉᶠ: the reference value that has been set. If Dᶜᵘʳ > 2Dʳᵉᶠ or 2Dᶜᵘʳ < Dʳᵉᶠ, OL% will display on the secondary display and the main display will show the measured value of the tested object. Access REL mode Press FUNC to select the desired AUTO L, AUTO C, AUTO R or AUTO DCR mode. Connect the tested object to the input terminals and press REL to access REL% mode. appears on the LCD with the main display showing the measured component value and the secondary display showing % of deviation. Press REL again and the reference value will show on the main display and the icon flashes, while the % value will still be visible on the secondary display. Press REL again to return to normal REL% measurement mode. Press and hold REL to exit REL% measurement and return to normal mode. SORTING MEASUREMENT Sorting mode is used to quickly select components value within a specified tolerance. Press FUNC to select the desired AUTO L, AUTO C, AUTO R or AUTO DCR mode. Connect the tested object to the input terminals and press and hold FREQ to access sorting mode. Sorting will appear on the LCD. This sets the limit value. PASS shows on the main display and the measured component value on the secondary display is set to a nominal value. Connect another component and PASS will show if the component falls within the set limit and the measured value shows on the secondary display. The buzzer will sound once. If it is out of scope, FAIL shows and the measured component value. Press and hold FREQ to exit. Set up sorting tolerance The sorting limit can be set at the following values: ±0.25%, ±0.5%, ±1%, ±2%, ±5% ±10%, ±20%, +80%~-20%. The meter defaults to ±1%. To set up sorting, put the meter under sorting mode first and then press SETUP and the Range icon will flash on the LCD. Press ENTER to confirm and set the main display parameter, of which the last digit flashes. Press / to decrease/increase the digit or / to select another flashing digit for adjustment. 7

Then press ENTER to go into the tolerance setup and the TOL±1% icon will flash on the LCD. Press / to adjust the tolerance and then press ENTER to confirm, to allow you to begin the sorting measurement. Press SORTING to exit sorting measurement and return to normal mode. CALIBRATION FUNCTION Calibration function can effectively reduce stray impedance caused by test wires. The meter offers short and open calibration. Short calibration is to remove the impact of contact resistance and test wire resistance that interferes with low impedance measurement. Open calibration is to remove stray capacitance and resistance of test wires that interfere with high impedance measurement. Access Calibration Function Power on the meter and press and hold CAL to access open calibration. OPEn will show on the secondary display (Fig. 1), then press CAL again to begin the calibration and the meter will count down from 30 seconds on the LCD. When it reaches zero PASS appears (Fig. 2), which indicates open calibration has finished. Press the CAL button and Srt appears on the secondary display (see Fig. 3). Insert short-circuit device into input terminals, press CAL to begin and the meter will count down from 30 seconds to 0 seconds. PASS appears indicating that short calibration is complete (Fig. 4). Press CAL again to return to normal measurement mode. Note: if the the LCD shows FAIL under open calibration mode, it indicates that the calibration has failed. Check whether the input terminals are open or not. Make sure the circuit is open and do the calibration again. Similarly, under short calibration mode if the LCD shows FAIL it indicates that the calibration has failed. Check the short circuit device has been inserted into the input terminals. Make sure the terminals are shorted and calibrate again. PC COMMUNICATION Insert the disc supplied and install software from auto run. Press the USB button to access communication function. Connect the meter to the PC using the USB wire and run the meter software on the PC to start data transfer. Press USB again to exit and stop the data transfer. 8 Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 DPEn Cal APO PRSS DPEn Cal APO Cal APO Src PRSS Src Cal APO FRIL DPEn

BACKLIGHT Press and hold the LIGHT button to turn on or off the LCD backlight. The backlight will automatically switch off after 60 seconds. AUTO POWER OFF Power will turn off after 5 minutes of idle time. SELECTION OF SERIAL/PARALLEL MODE A suitable equivalent mode can be selected to gain more precise measurement data. In general, it is suggested to select serial equivalent mode for low impedance element, such as less than 100Ω. Select parallel equivalent mode for high impedance element, such as more than 10kΩ. INDUCTANCE MEASUREMENT Press the power button and then press FUNC to display Lp on the LCD. Select inductance measurement range. Insert the inductor into input terminals or connect the inductor to the meter using the test clamp. Press FREQ to select suitable testing frequency. Press D/Q/θ to select the auxiliary parameter to measure. CAPACITANCE MEASUREMENT Capacitors must be completely discharged before measurement. Press the power button, then press FUNC to display Cp on the LCD and select capacitance measurement range. Insert the capacitor into input terminals or connect the capacitor to the meter using the test clamp. Press FREQ to select a suitable testing frequency. Then press D/Q/θ to select the auxiliary parameter to measure. 9

RESISTANCE MEASUREMENT Press the power button. Press FUNC to display Rp on the LCD and select resistance measurement range. Insert the resistor into the input terminals or connect the resistor to the meter using the test clamp. Press FREQ to select a suitable testing frequency. Note: When measuring resistance under auto mode, the secondary parameter θ will be activated. If under manual mode, the secondary parameter of resistance will be neglected. DCR MEASUREMENT Press the power button. Press the FUNC button to display DCR on the LCD and select DCR measurement range. Insert the resistor into the input terminals or connect the resistor to the meter using the test clamp. Note: The secondary parameter and the frequency is negligible under DCR measurement and doesn t show on the LCD. PC COMMUNICATION SPECIFICATION Communication parameters: 1) Baud rate: 9600 2) Data bit: 8 3) Start bit: 1 4) Stop bit: 1 5) Parity: None Refer to the connection diagram (right). TECHNICAL INDICATORS 1) Testing ambient temperature: 23 C ± 5 C, humidity = 75% RH. 2) Warm up for 10 minutes before testing. 3) Test on the meter s terminals. 4) Perform short/open calibration before testing. 10

Function: Inductance gear Measurement Mode: Lˢ/Lᵖ Frequency 100Hz / 120Hz 1kHz 10kHz 100kHz Range Min. Resolution Accuracy: ± (a% of reading + b digits) (18 C to 28 C) 20.000mH 1µH ± (1.0% + 5) 200.00mH 0.01mH ± (0.5% + 5) 2000.0mH 0.1mH ± (0.5% + 5) 20.000H 1mH ± (0.5% + 5) 200.00H 0.01H ± (1.0% + 5) 2000.0H 0.1H ± (1.0% + 5) 2000.0µH 0.1µH ± (1.0% + 5) 20.000mH 1µH ± (0.5% + 5) 200.00mH 0.01mH ± (0.5% + 5) 2000.0mH 0.1mH ± (1.0% + 5) 20.000H 1mH ± (1.0% + 5) 200.00H 0.01H ± (2.0% + 5) 20.000µH 0.01µH ± (1.0% + 5) 200.00µH 0.01µH ± (1.0% + 5) 2000.0µH 0.1µH ± (0.5% + 5) 20.00mH 1µH ± (0.5% + 5) 20.000µH 0.001µH ± (2.0% + 5) 200.00µH 0.01µH ± (2.0% + 5) 2000.0µH 0.1µH ± (2.0% + 5) Note: The precision is evaluated if D is less than 0.1. Ae=Ae* 1+D² if D exceeds 0.1. (Ae: Precision). Function: Capacitance gear Measurement mode: Cˢ/Cᵖ Frequency 100Hz / 120Hz Range Min. Resolution 11 Accuracy: ± (a% of reading + b digits) (18 C to 28 C) 20.000nF 1pF ± (2.0% + 5) 200.00nF 0.01nF ± (0.5% + 5) 2000.0nF 0.1nF ± (0.5% + 5) 20.000µF 1nF ± (0.5% + 5) 200.00µF 0.01µF ± (1.0% + 5) 2000.0µF 0.1µF ± (2.0% + 5) 20.00mF 0.1mF ± (2.0% + 5)

1kHz 10kHz 100kHz 2000.0pF 0.1pF ± (1.0% + 5) 20.000nF 1pF ± (1.0% + 5) 200.00nF 0.01nF ± (0.5% + 5) 2000.0nF 0.1nF ± (0.5% + 5) 20.000µF 1nF ± (0.5% + 5) 200.00µF 0.01µF ± (1.0% + 5) 2000.0µF 0.1µF ± (1.0% + 5) 2000.0pF 0.1pF ± (1.0% + 5) 20.000nF 1pF ± (1.0% + 5) 200.00nF 0.01nF ± (1.5% + 5) 2000.0nF 0.1nF ± (2.0% + 5) 2000.0pF 0.1pF ± (2.0% + 5) 20.000nF 1pF ± (2.0% + 5) 200.00nF 0.01nF ± (5.0% + 5) Note: The precision is evaluated if D is less than 0.1. Ae = Ae* 1+D² if D exceeds 0.1. (Ae: Precision). Function: Resistance gear Measurement mode: Rˢ/Rᵖ Frequency 100Hz / 120Hz 1kHz Range Min. Resolution Accuracy: ± (a% of reading + b digits) (18 C to 28 C) 200.00Ω 0.01Ω ± (1.0% + 5) 2.0000kΩ 0.1Ω ± (0.3% + 5) 20.000kΩ 1Ω ± (0.3% + 5) 200.00kΩ 0.01kΩ ± (0.5% + 5) 2.0000MΩ 0.1kΩ ± (1.0% + 5) 20.000MΩ 1kΩ ± (2.0% + 5) 20.000Ω 0.001Ω ± (1.0% + 5) 200.00Ω 0.01Ω ± (1.0% + 5) 2.0000kΩ 0.1Ω ± (0.3% + 5) 20.000kΩ 1Ω ± (0.3% + 5) 200.00kΩ 0.01kΩ ± (0.5% + 5) 2.0000MΩ 0.1kΩ ± (1.0% + 5) 20.000MΩ 1kΩ ± (2.0% + 5) 12

10kHz 100kHz 20.000Ω 0.001Ω ± (1.0% + 5) 200.00Ω 0.01Ω ± (1.0% + 5) 2.0000kΩ 0.1Ω ± (0.3% + 5) 20.000kΩ 1Ω ± (0.5% + 5) 200.00kΩ 0.01kΩ ± (1.0% + 5) 2.0000MΩ 0.1kΩ ± (2.0% + 5) 20.000Ω 0.001Ω ± (2.0% + 5) 200.00Ω 0.01Ω ± (2.0% + 5) 2.0000k 0.1Ω ± (2.0% + 5) 20.000kΩ 1Ω Function: Resistance gear Measurement mode: DCR Frequency Range Min. Resolution Accuracy: ± (a% of reading + b digits) (18 C to 28 C) 200.00Ω 0.01Ω ± (1.0% + 5) 2.0000kΩ 0.1Ω ± (0.3% + 5) 20.000kΩ 1Ω ± (0.3% + 5) 200.00kΩ 0.01kΩ ± (0.5% + 5) 2.0000MΩ 0.1kΩ ± (1.0% + 5) 20.000MΩ 1kΩ ± (2.0% + 5) 200.00MΩ 0.1MΩ ± (2.0% + 5) Note: The precision is evaluated if D is less than 0.1. Ae = Ae* 1+D² if D exceeds 0.1. (Ae: Precision). BATTERY REPLACEMENT Replace the battery as soon as the low battery symbol appears on the LCD, in order to avoid an impact on measurement accuracy. Replace the old battery with a new battery of the same specification (9V). 13

MAINTENANCE Cleaning Ensure the power is off and remove the battery and external power before cleaning. Clean the meter with a soft cloth and mild detergent. Do not use any chemicals, abrasives or solvents that could damage the meter. Ensure the detergent does not enter the meter. Only use the meter if it is completely dry. Moisture Prevention Use and store the meter in a dry environment. Switch the power off and remove the battery quickly if the water enters the casing. Do not disassemble the meter randomly. Have the meter checked by qualified personnel. Repair If the meter doesn t power on, inspect the battery, external power and power input terminal. If the measurement does not work normally, check if the test wires are in good condition and if the component pin has been connected with the input terminals. Refer all servicing to qualified personnel. Do not disassemble the meter, replace components or change the circuits randomly. INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT. When this product has reached the end of its life it must be treated as Waste Electrical & Electronic Equipment (WEEE). Any WEEE marked products must not be mixed with general household waste, but kept separate for the treatment, recovery and recycling of the materials used. Contact your local authority for details of recycling schemes in your area. Made in China. www.premierfarnell.com 14 V.1.0