Wireless CO 2. + TRH Sensor. Installation Guide. Version 1

Similar documents
Mx-RPW Room Control Module (Built-In Occupancy Sensor)

Wireless Ceiling Mount Sensor

TS-WS-07 Wireless Indoor/Outdoor 8-Channel Thermo-Hygrometer with Jumbo Display User Manual

Wireless sensor system

Quick Start: Radiator Control

Pushbutton Transmitter Device PTM 215 ZGPGP. June 10, 2014 USER MANUAL V1.0. Patent protected: US 6,747,573 US 7,019,241 Further patents pending

Air Quality Sensor KNX AQS

4. Set the FLSER tool switch to the S-RID position. 5. Push the + and - buttons to select the sensor ID (SID) for the transmitter.

Wireless valve actuator for bidirectional EnOcean communication. The SAB05 combines with message server and enocean transmitter.

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

Wireless Rain and Wireless Rain/Freeze Sensor

The Deeter Group. Wireless Site Survey Tool

MLR-1105 (DC battery type door chime receiver) LMLT-711 (push unit door chime transmitter)

Technical Application Guide

Door/Window Sensor User Manual HKWL DWS02W

AURATON 2020 AURATON 2020 TX RX Plus

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Wireless occupancy/vacancy sensor

PM 6669 High-Precision Frequency Counter Specifications

P700-WLS ioprox Receiver

LRF20CR2BPWH Ceiling MNT Wireless Occ Sensor

SV613 USB Interface Wireless Module SV613

Building Intelligence

Installation And Programming Instructions For Profile Series With RF Technology

TE-7700 Series Radio Frequency (RF) Wireless Room Temperature Sensing System

MPRF01 Wireless 5uA Inductive Proximity Sensor RF System

WS-7136U Wireless 433 MHz Temperature Station. Instruction Manual

User Manual. P6 Barcode Scanner. English

User Manual Laser distance sensor. series OWLE. Welotec GmbH Zum Hagenbach Laer Manual_OWLE _EN 1/20

Wireless Room Thermostat Installation and Operation Y6630D1007

with Light Level, Isolated Relay and Manual On features

PIECAL Model 541 Frequency Calibrator with Totalizer Operating Instructions

WIRELESS Energy Monitor - Smart Meter

WS-7212NU Wireless 433 MHz Weather Station. Instruction Manual

WS-7220U-IT 915 MHz Wireless Weather Station. Instruction Manual


CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

S-Series Digital Thermostat

SER8300 Series Terminal Equipment Controller with Optional PIR sensor Installation Guide

BCST-20 Barcode Scanner. Instruction Manual.

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

M2M i-link POINT-TO-MULTIPOINT INSTALLATION INSTRUCTIONS

Digital Electronic Thermostat With RF

Pushbutton Transmitter Device PTM 215Z. September 17, 2013 USER MANUAL V1.0. Patent protected: US 6,747,573 US 7,019,241 Further patents pending

MultiSensor 6 (User Guide)

WIRELESS BASE STATION WIRELESS CONFIGURATION TOOL WIRELESS REPEATER

User Manual. BCST-60 Barcode Scanner. English

LMLR-710 (Plug-in type door chime receiver) LMLT-711 (push unit door chime transmitter)

WPR400 Wireless Portable Reader

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

Table 1. Placing the Sensor in the Sensor Cradle. Step Instruction Illustration

Preliminary. 4-Channel RTD/4-20 ma Wireless Sensor Node SN24R420-4

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

PIECAL 211 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

G3P-R232. User Manual. Release. 2.06

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

Outdoor IP64 Temperature and Humidity LoRaWAN Sensor RHF1S001

Radio Powr SavrT Occupancy / Vacancy Sensor

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2

v3 360 Passive Infrared Line Voltage Occupancy Sensor

Datasheet. Tag Piccolino for RTLS-TDoA. A tiny Tag powered by coin battery V1.1

Wireless Temp/Setpoint & Override Room Transmitter

Radio Window Sensor and Temperature Sensor Programming in HomeWorks QS

Battery Powered People Counter with Integral LCD Display & 418Mhz Data Transmitter

radio controlled, battery-powered radiator valve actuator SAB05 with M30x1,5 connection

Infrared Carbon Dioxide Sensor Module CM1108-Dual Beam

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

P700WLS IoProx Receiver

SYSTEM SENSOR WIRELESS REMOTE INDICATOR PRODUCT SPECIFICATION

Radio Powr SavrTM Wireless Occupancy / Vacancy Ceiling Sensor

TWINDRIVE TD32. Data sheet LINAK.COM/HOMELINE

WLS-5500 Receiver (KSF & W26)

TC-LINK -200 Wireless 12 Channel Analog Input Sensor Node

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

TABLE OF CONTENT A. Installation and Mounting Installation 3 2. Mounting Receiver Addressing... 5 B. Key Interface. 7 C.

Above All. The most sophisticated unit for tracking containers in real time for security and management.

Ambient Weather WS-0270 Wireless Indoor / Outdoor Thermometer with Indoor Humidity User Manual

Allure ECW-Sensor Series

Home Automation, Inc. Model 12A00. Wireless Receiver. Installation Manual

Wireless Ceiling Motion Sensor for Occupancy / Vacancy Detection with integrated diagnostic tools INSTALLATION GUIDE

DragonLink Advanced Transmitter

Data sheet. Function description. Benefits

Intelligent Infrared CO2 Module (Model: MH-Z19)

ELECTRONIC THERMOSTAT: T920

200 RTH OFF ON IN OUT ALARM RESET

TE-7700 Series Radio Frequency (RF) Wireless Room Temperature Sensing System

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2

Energate Foundation Meter Data Collector Installation Guide

Wireless heating valve actuator MVA004 EnOcean

Infrared Carbon Dioxide Sensor Module CM1106-Single Beam

Wireless Sensor for Humidity / Temperature / CO 2

Keycards come with an imbedded RFID chip and antenna, there is no battery in the keycards. The keycards are encrypted and only

200, 201 Series Radio Telemetry Transmitters

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

RN-41-SM. Class 1 Bluetooth Socket Module. Features. Applications. Description. Block Diagram. rn-41sm-ds 9/9/2009

Transcription:

Wireless CO 2 + TRH Sensor Installation Guide Version 1

2 CO2 + TRH Sensor Installation Guide Introduction The wireless CO 2 + TRH (Carbon Dioxide + Temperature and Relative Humidity) sensor is a wall mounted device with ambient (indoor) comfort monitoring and HVAC control applications. Please note the sensor is available in two variations: 1. CO 2 + TRH sensor (SED-CO2-G-5045) 2. TRH only sensor (SED-TRH-G-5045) All information related herein applies to both models, except for CO2 functionalities which are only available on the CO2 + TRH sensor. The sensor can measure ambient temperature, relative humidity and depending on the model - CO 2 concentration. The measured data is communicated wirelessly using ZigBee Green Power protocol to a Room/ Zone controller. Description The sensor integrates an ultra-low power CO 2 and a digital temperature(t) and relative humidity (RH) sensor. The Human Machine Interface (HMI) of the sensor is based on a bi-color Light-Emitting Diode (LED) and a pushbutton, both covered by a plastic housing. A small tool or stylus is needed to push the button located through a small hole. The LED flashes through the top plastic cover and is not visible when not active. All communication with the device is done wirelessly via a bidirectional ZigBee Green Power protocol after a successful pairing/commissioning procedure. The sensor is powered by an embedded AA size lithium-thionyl chloride spiral battery (not rechargeable, not removable). The battery capacity allows up to 10 years of operating time at nominal conditions. The device must be replaced and recycled when the battery is discharged. Box Contents The wireless CO 2 + TRH sensor box contains the following: Wireless CO 2 + TRH sensor or TRH sensor Wall-mounting bracket Two screws for wall-mounting bracket Installation guide System Requirements If used in conjunction with a Schneider Electric Room Controller, the wireless CO 2 + TRH sensor requires a SE8000 Series Room Controller running firmware version 1.7 or higher. The CO 2 + TRH sensor is not compatible with SE7000 Series Room Controllers.

CO2 + TRH Sensor Installation Guide 3 Installation The wireless CO 2 + TRH sensor can be secured directly on a wall or flat surface using double-sided adhesive tape (Fig.2), or by securing the plastic bracket to the wall (Fig.1) and mounting the sensor (Fig. 3). Using the screws is the recommended method. Attaching A Sensor Using The Wall Bracket 1. Using two screws provided, secure wall bracket to wall (Fig. 1). To perform an accurate ambient comfort measurement, the sensor should not be installed in areas exposed to direct sunlight or near doors, windows or areas exposed to air flow. 2. Once bracket is secured, slide sensor on bracket using downward motion. 3. Ensure click sound is heard to verify sensor is secured to bracket and ensure side tab of bracket is aligned with opening on side of sensor (Fig. 3). Figure 1 It is strongly recommended to attach the sensor to the wall by using the two screws. The adhesive in double-sided tape may not be as long-lasting or as strong to support the sensor throughout its lifetime. Double-sided adhesive tape zone Figure 2

4 CO2 + TRH Sensor Installation Guide ZigBee De-mounting the sensor from the wall bracket: Figure 3 To remove the sensor from the wall bracket, press on the side tab as circled in Fig.3 and slide the sensor up and then out. Technical Characteristics The sensor is intended for indoor applications. The operating temperature range is 0 45 C. For an accurate CO 2 concentration measurement the sensor should operate in 0 to 95% RH, non-condensing environment. Sensor Features CO 2 Concentration Digital Temperature Relative Humidity Operating Range 0 5000 ppm - 10 ~ 85 C 0-100 % Accuracy (typ. @ 25 C) ±50 ppm +/- 3% of reading ± 0.3 C ± 2% Accuracy (max @ Tmin,max) ± 80 or up to +/- 3% of readings ± 0.4 C ± 3% Resolution (typ. @ 25 C) ±17 ppm (or up to 1σ @ 1000ppm) 0.01 C 0.025% Resolution (max @ Tmin,max) ± 50ppm (@Tmax) 0.01 C 0.025% Radio communication protocol used by the wireless sensor is compliant with the ZigBee Green Power standard supporting bi-directional communication, commissioning and security encryption features. The device is ZigBee 3.0 compliant. Wireless Technology Operating Frequency Technical Data ZigBee Green Power 2.4 GHz Transmission Range (typ) 20m (indoor) / 100m (free field) Measuring & Transmitting Period (typ) Operating Conditions Storage Conditions Product Lifespan¹ Power Rating 2,5-10 min or up to 100m (line of sight) Note: Range may vary depending on local interference sources or RF attenuation from building materials. 0 C to 50 C (32 F to 122 F) 0% 95 % rh non-condensing environment -30 C to 50 C (-22 F to 122 F) 0% 95 % rh non-condensing environment typ 10 years 3.6vDC (Non-replaceable battery) Peek Current: 0.1A ¹ The battery lifetime depends on measurement and communication parameters setting and can vary depending on sampling rate, communication rate, or environmental operating conditions.

CO2 + TRH Sensor Installation Guide 5 Interface A wireless CO 2 + TRH sensor is deployed by setting the interface with a push button and a multi-color LED. Both are hidden under the sensor housing and intended for use by a trained installer only. Multi-color LED Push button hole Figure 4 ZigBee Source ID label 0x01A00BBF (3007) Figure 5

6 CO2 + TRH Sensor Installation Guide Refer to the information below for detailed sensor operating instructions. Push button The push button can be pressed through a hole from the bottom side of the sensor, with a slim tool (Figure 4). Each recorded button press is signaled by 2 yellow LED flashes. Short push One short push starts the commissioning procedure if the sensor is in the decommissioned (energy saving / hibernation) mode. If the sensor is already commissioned, it will enter demo mode for a 5min timeout interval. Long push One long push puts the sensor into decommissioned / hibernate mode. The long push is confirmed by one red LED flash roughly 1 second after 2 yellow LED push signaling flashes. After a red LED signal, the button should be released in order to prevent another unintended short push detection. Multi-colour LED The multicolor LED is hidden under the top plastic cover, positioned on left (Figure 4). In normal state the LED is off in order to conserve battery life. It is only used to signal the following special events: 2 YELLOW flashes confirm each button push taken into account by the sensor. 1 RED flash acknowledges a long push. The decommissioning procedure and a sensor reset will be executed, then the sensor will enter hibernation mode. 3 RED flashes signal a commissioning procedure failure. The sensor stays in decommissioned / hibernation mode. 3 GREEN flashes signal a commissioning procedure success. The sensor will enter demo mode for 5 min. This demo mode will automatically timeout after 5 minutes. The sensor then stays in commissioned mode, periodically transmitting the measured values to the receiver. 1 GREEN flash acknowledges a valid GP command received by the sensor in demo mode. This feature can be used as a feedback to an installer to confirm that the sensor is still in range during the commissioning (it works only in demo mode). In this case the receiver has to be programmed to send an acknowledgement command to the sensor after the sensor data report frames. The multiple LED flashes are executed only in 1/2 second intervals. Operating Modes Factory Mode The wireless CO 2 + TRH sensor is in a deep sleep mode waiting for a button push. No measurements, no radio communications are preformed. Commissioning During commissioning the wireless CO 2 + TRH sensor will automatically find and pair with the nearest compatible ZigBee Green Power receiver. ZigBee parameters (e.g. operational channel, Src-ID, PAN-ID, security level and key) are exchanged between the sensor and receiver in order to establish a reliable and secure link. During commissioning the sensor is presented as an UNSPECIFIED DEVICE (GP ModelID = 0xFE) with the GP Product ID = 17305 (0x4399) and its unique source ID (SrcID). The SrcID of each sensor is marked on its backside (Figure 5). The receiver should be ZigBee 3.0 compliant. The commissioning procedure can be triggered only from the Decommissioned / Hibernation Mode by a long push of the button. The commissioning procedure can be resumed through the following steps: 1. Set a ZigBee operational channel (11-26) and the PAN-ID of your network (0xFFFF by default) on your ZigBee 3.0 compliant receiver. 2. Put the receiver into the automatic commissioning mode (opened for the commissioning and accepting the commissioning with GP ModelID = 0xFE and GP Product ID = 17305 devices). 3. On the wireless CO 2 + TRH sensor press the push button once to start the bidirectional ZGP commissioning. The button actuating is immediately confirmed by two yellow LED pulses. The sensor then automatically scans all ZigBee channels (channel 11-26) in order to find the nearest ZGP Proxy device (receiver in commissioning mode) and initiates the pairing. 4. Wait approximately 10s during this time the sensor automatically performs the commissioning. The LED will not flash during this period (even if you push the button again). 5. Commissioning success is indicated by 3 green LED pulses. You can check measured data reported from the sensor to the receiver. If the commissioning fails (indicated by 3 red LED pulses) please ensure the sensor is in Factory Mode and in proximity of the receiver, then repeat the procedure.

CO2 + TRH Sensor Installation Guide 7 Demo Mode The data measurement and TX period is temporarily reduced to 5 seconds. The green LED flashes once after each valid ZGP command reception by the sensor. This feature can be used as a feedback to an installer confirming that the sensor is still in the radio range of the receiver. Remember the sensor can receive a ZGP command only after a measured values report, so maximum green LED flashing rate is 5s. The receiver has to be programmed to send an acknowledgment command to the sensor. The sensor automatically switches to Commissioned Mode once the 5min timeout elapses. Normal Mode The sensor periodically measures T, rh and CO 2 and reports the measured values to the receiver which it is paired with. By default the nominal measurement and Transmission(TX) period is 150s (2min and 30sec). This parameter can be edited by a ZigBee command. The sensor is always sleeping in between two data measurements and TX. It can be woken up at any time with the push button. When the CO 2 concentration drops below the customizable comfort value the transmission period is multiplied by 4. The sensor automatically returns back to nominal transmission period if the CO 2 concentration value exceeds the comfort threshold value. CO2 Sensor Autocalibration Principle of operation The CO 2 module inside the wireless CO 2 + TRH sensor, is fully calibrated prior to shipping from the factory. Over time, the measurement offset needs to be calibrated to maintain the long term stability of the sensor. In most applications, this can happen automatically using the built in autocalibration function. This technique can be used in situations in which sensors will be exposed to typical background levels (400-450ppm) at least once during the auto-calibration period. For example, many buildings will drop quickly to background CO 2 levels when unoccupied overnight or at weekends. The auto-calibration function uses the information gathered at these periods to recalibrate. The auto-calibration function uses the lowest point of CO 2 concentration to recalibrate the offset. During every measurement cycle, the CO 2 sensor stores the latest values, and also the lowest value recorded since the last calibration point. The first 50 measurements after calibration are ignored when calculating the lowest value. Autocalibration default setting The CO 2 sensor is shipped with the auto-calibration feature enabled. There isn t any CO 2 measurement in the Factory Mode before the Commissioning. After the Commissioning all previous CO 2 measurement data stored in the sensor is erased. By default the first autocalibration will happen 1 day after the commissioning, and the following auto-calibrations in 8-day intervals.

Technical Support For any issues with SmartStruxure Solution or SmartStruxure Lite, contact Schneider Electric Technical Support according to your region. North America (NAM) Product Support Building Management Systems (BMS): www.nampss.com Global Product Support Building Management Systems (BMS): productsupport.bms@schneider-electric.com https://exchangecommunity.schneider-electric.com/community/bms/smartstruxure-lite Schneider Electric is the global specialist in energy management and automation. With revenues of ~ 25 billion in FY2016, our 160,000+ employees serve customers in over 100 countries, helping them to manage their energy and process in ways that are safe, reliable, efficient and sustainable. From the simplest of switches to complex operational systems, our technology, software and services improve the way our customers manage and automate their operations. Our connected technologies reshape industries, transform cities and enrich lives. At Schneider Electric, we call this Life Is On.