COMMUNICATIONS Volume-Selective Multipulse Spin-Echo Spectroscopy

Similar documents
Chapter 11 Coherence Editing: Pulse-field Gradients and Phase Cycling

In a typical biological sample the concentration of the solute is 1 mm or less. In many situations,

10. Phase Cycling and Pulsed Field Gradients Introduction to Phase Cycling - Quadrature images

(N)MR Imaging. Lab Course Script. FMP PhD Autumn School. Location: C81, MRI Lab B0.03 (basement) Instructor: Leif Schröder. Date: November 3rd, 2010

1 Introduction. 2 The basic principles of NMR

HETERONUCLEAR IMAGING. Topics to be Discussed:

Background (~EE369B)

SUPPORTING INFORMATION

MAGNETIC RESONANCE IMAGING

Pulse Sequence Design and Image Procedures

Workshop on Rapid Scan EPR. University of Denver EPR Center and Bruker BioSpin July 28, 2013

Supplementary Figure 1. Scanning Electron Microscopy images of the pristine electrodes. (a) negative electrode and (b) positive electrode.

H 2 O and fat imaging

Half-Pulse Excitation Pulse Design and the Artifact Evaluation

IR/SR TrueFISP. Works-in-Progress package Version 1.2. For the SIEMENS Magnetom. Installation and User s Guide NUMARIS/4VA21B.

HMBC 17. Goto. Introduction AVANCE User s Guide Bruker 185

Pulse Sequence Design Made Easier

PHY3902 PHY3904. Nuclear magnetic resonance Laboratory Protocol

Ultrahigh-resolution Total Correlation NMR Spectroscopy

Applications Guide. Spectral Editing with SVS. (Works-in-Progress) MAGNETOM TaTs and Verio Systems (3T)

NMR FACILITY NEWSLETTER

MR Advance Techniques. Flow Phenomena. Class II

Implementation of parallel search algorithms using spatial encoding by nuclear magnetic resonance

2015 Spin echoes and projection imaging

System/Imaging Imperfections

Your first NMR measurement

Fast Methods for Small Molecules

Development of a new Q-meter module

Inherent Insensitivity to RF Inhomogeneity in FLASH Imaging

Open acqi window if the button has been lost. autolocking routine, alock= y for autolocking, alock= n for typical manual locking

PULSED/CW NUCLEAR MAGNETIC RESONANCE

Evaluation of Adiabatic Frequency-Modulated Schemes for Broadband Decoupling in Isotropic Liquids

Nutation Spectra of Nuclear Quadrupole Resonance in Off-Resonance Conditions

Steady-state sequences: Spoiled and balanced methods

H Micro-Imaging. Tuning and Matching. i. Open any 1H data set and type wobb.

Cardiac MR. Dr John Ridgway. Leeds Teaching Hospitals NHS Trust, UK

1D Transient NOE on the Bruker DRX-500 and DRX-600

Principles of MRI EE225E / BIO265. Lecture 21. Instructor: Miki Lustig UC Berkeley, EECS. M. Lustig, EECS UC Berkeley

NMR Spectroscopy with Radio Frequency Gradients.

A Conceptual Tour of Pulsed NMR*

Gradient Spoiling. Average balanced SSFP magnetization Reduce sensitivity to off-resonance. FFE, FISP, GRASS, GRE, FAST, Field Echo

Characterization of Water-in-Bitumen Emulsions in Model Porous Media by NMR Microscopic Imaging Techniques

Spiral MRI on a 9.4T Vertical-bore Superconducting Magnet Using Unshielded and Self-shielded Gradient Coils

Bottomley. United States Patent (19) 4,629, Patent Number: 45 Date of Patent: Dec. 16, 1986

Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil

PINMRF. Varian 300 MHz NMR Spectrometers User Guide for Advanced 1D and Basic 2D NMR Experiments

8 COSY. 8.1 Introduction. 8.2 Magnitude COSY

Lab 8 6.S02 Spring 2013 MRI Projection Imaging

Pulsed NMR Experiment Guide Kenneth Jackson Physics 173, Spring 2014 Professor Tsai

Gradients. Effects of B0 gradients on transverse magnetisation Similar to figure 10 of Sattler review Progr. NMR 34 (1999), 93

Excitation and detection schemes in pulsed EPR

High-Field Surface-Coil MR Imaging of Localized Anatomy

NMR Basics. Lecture 2

Noninvasive Blood Flow Mapping with Arterial Spin Labeling (ASL) Paul Kyu Han and Sung-Hong Park

Development of a 1.0 T MR microscope using a Nd-Fe-B permanent magnet

M R I Physics Course. Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia

Implementing ultrafast 2D NMR experiments on a Bruker Avance Spectrometer

Supplementary Information

B12. SIMPSON Exercises

BOLD fmri: signal source, data acquisition, and interpretation

2 Hardware for Magnetic Resonance Imaging

Signs of Frequencies and Phases in NMR: The Role of Radiofrequency Mixing

RAD 229: MRI Signals and Sequences

Localization of microscale devices in vivo using addressable transmitters operated as magnetic spins

Module 2. Artefacts and Imaging Optimisation for single shot methods. Content: Introduction. Phase error. Phase bandwidth. Chemical shift review

Image Quality/Artifacts Frequency (MHz)

High Field MRI: Technology, Applications, Safety, and Limitations

GUIDELINES FOR THE REPRESENTATION OF PULSE SEQUENCES FOR SOLUTION-STATE NUCLEAR MAGNETIC RESONANCE SPECTROMETRY

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

NIH Public Access Author Manuscript Magn Reson Med. Author manuscript; available in PMC 2010 July 21.

If the magnetic field is larger, more energy is required to excite a given nucleus.

KJM D-SELECTIVE NMR Experiments on the AVIIIHD-800. Version 1.0. Topspin 3.5 Windows 7

Principios Básicos de RMN en sólidos destinado a usuarios. Gustavo Monti. Fa.M.A.F. Universidad Nacional de Córdoba Argentina

Sensitivity enhancement of the central transition NMR signal of quadrupolar nuclei under magic-angle spinning

A Progressive Gradient Moment Nulling Design Technique

Magnetic Resonance Imaging Principles, Methods, and Techniques

The Agilent OneNMR Probe

Phase-Sensitive Detection

Magnetic Resonance Imaging

SELF-QUENCHED SUPER-REGENERATIVE DETECTOR FOR NUCLEAR MAGNETIC RESONANCE BY a SURYAN SUMMARY 1. INTRODUCTION

2014 M.S. Cohen all rights reserved

Introduction to MR Hardware. RF Coils C M L C T. = g * B 0. Rotating magnetization produces alternating magnetic field

MRI Metal Artifact Reduction

Waveguiding in PMMA photonic crystals

A Novel Design of a Low Temperature Preamplifier for Pulsed NMR Experiments of dilute 3 He in Solid 4 He

A k-space Analysis of Small-Tip-Angle Excitation

Clear delineation of optic radiation and very small vessels using phase difference enhanced imaging (PADRE)

Helicon mode formation and rf power deposition in a helicon source

Mapping of the New IBA Superconducting Synchrocyclotron (S2C2) for Proton Therapy

Interference in stimuli employed to assess masking by substitution. Bernt Christian Skottun. Ullevaalsalleen 4C Oslo. Norway

MR in RTP. MR Data for Treatment Planning: Spatial Accuracy Issues, Protocol Optimization, and Applications (Preview of TG117 Report) Acknowledgements

A Complete Digital Magnetic Resonance Imaging (MRI) System at Low Magnetic Field (0.1 Tesla)

Improving high-field MRI using parallel excitation

PULSED NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

KJM D-SELECTIVE NMR Experiments on the AVI-600 and AVII-600. Version 1.0. Topspin 3.5 Windows 7 Topspin 1.3 Windows XP

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Passive Tracking Exploiting Local Signal Conservation: The White Marker Phenomenon

A digital method for separation and reconstruction of pile-up events in germanium detectors. Abstract

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

Technique for the Derivation of Wide Band Room Impulse Response

Transcription:

JOURNAL OF MAGNETC RESONANCE 72,379-384 (1987) COMMUNCATONS Volume-Selective Multipulse Spin-Echo Spectroscopy R. KMMCH* AND D. HOEPFEL? *Universitri t Urn, Sektion Kernresonanzspektroskopie, D-7900 Urn, Federal Republic of Germany, and tbruker Medizintechnik GmbH, Silberstreifen, D-7512 Rheinstetten, Federal Republic of Germany Received July 11, 1986; revised December 28, 1986 n the last few years a series of methods for spatially selective NMR spectroscopy has been suggested especially for in vivo investigations. We particularly refer to the work by Aue et al. (), Ordidge et al. (2), and Doddrell et al. (3). The general aim of these techniques is to record a spectrum of a well-defined volume element preselected on the basis of a conventional slice image. n this communication we report on a new multipulse method for volume-selective spectroscopy (VOSY) which has the advantage of being simple, fast, and versatile. n contrast to the other techniques it selectively excites the desired volume element in the proper sense rather than to suppress signals from the undesired volume. Three-pulse sequences have previously been used for pure imaging purposes (4, 5). As we will show in the following, special modifications of this sequence are also suitable for volume-selective spectroscopy. Despite the apparent similarity of the pulse programs to the imaging sequences suggested in Refs. (4, 5), the VOSY technique is based on a different philosophy which opens a new class of volume-selective NMR experiments and extensions to multipulse sequences. Figures 1 and 2 show three-pulse VOSY RF- and field-gradient-pulse programs as examples and as demonstration of the principle (compare Hahn s paper (6)). Three slice-selective RF pulses with field-gradient pulses in the three spatial directions are applied. The pulse lengths are 90 but shorter pulses will serve also. Let us first describe how the different echo signals are formed in principle and then the methods for selective detection. Each RF pulse is followed by a free-induction signal of the selected slice. Thus the signals Aj (i = 1,2, 3) in Fig. 1 represent the corresponding three perpendicular slices. Each single excitation coherence is partially refocused by each of the following RF pulses so that the two-pulse echoes Bi (i = 1,2,3) are formed. Thus three line-selective signals Bi appear. These line-selective coherences can again be partially refocused by one or more subsequent RF pulses. n the pulse scheme of Fig. 1 only one three-pulse echo of this type, namely the signal C,, arises selectively for the volume element common to the three slices. A further three-pulse signal appears as the stimulated echo C2 which again is due to the volume element selected by the three slices. ts formation is based on the lineselective transfer of transverse magnetization in the z direction where the magnetization 379 0022-2364187 $3.00 Copyrisbt 0 1987 by Academic R s, nc. AU rights of repmdw2tion in any form -al.

380 COMMUNCATONS signals ia, n ia2 Bl A, C2 C '32 83 n; jln, U U" t, FG.. Three-pulse VOSY RF-pulse scheme and overview of the diverse signals used to produce volumeselective high-resolution signals. Ai, slice-selective signals; B,, line-selective signals, Ci, volume-selective signals. A set of appropriate field-gradient-pulse sequences is shown in Fig. 2. is stored for an interval Q. The third pulse then selectively produces a spin coherence in the transverse plane leading to the stimulated echo C2. This signal thus is influenced by a T, decay in the Q interval which interrupts the evolution of the initial spin coherence, and by T2 decays in the other intervals (T, spin-lattice relaxation ; T2 transverse relaxation ). The echoes Bi and C,, on the other hand, are formed without any Ti-sensitive interval. The observation of the signals described above appears to be difficult because of two aggravating circumstances. First, the selection gradients simultaneously defocus the coherences if they are distributed asymmetrically over the echo formation intervals. Second, even with appropriate choice of the s 7 1 and TV, considerable signal overlap must be expected. These difficulties can however be safely overcome by special gmdientpulse programs. n Fig. 2 we suggest a series of schemes for the selective detection of the signals B2, B3, C,, and C3. Two proposals are made for the selection of each of the different signals. One can either correct the dephasing tendency of the selection gradients by appropriate correction gradient pulses or use an appropriate combination of nonrefocusing and totally or partly self-refocusing selection gradients. n each case, the additional gradient pulses have to be optimized separately for maximum echo amplitude. As the schemes in Fig. 2 are self-explanatory, we do not go into further details. Note, however, that unwanted coherences are, so to speak, automatically spoiled by the asymmetry of the slice-selection gradients in the course of the pulse sequence. f this homospoil effect should be insufficient, either additional gradient pulses can be applied or, preferably, the asymmetry can be increased by partial prolongation of the slice-selection gradients (Fig. 2). The latter method has been applied in the C2-selective test experiment described in the following. The C2 selection in our test experiment has been performed with the gradient-pulse

COMMUNCATONS 381, b G, GV G,/ 82 L B3-selectionG ~ j x, GN Y m a m --- / h G,j Gx 6, B, Gk G,! G,i B3!L, \ < -- C t -selectiongx; G,: G, B, G,! C, a r-l ) v. :. _. v.l- -&.---~ ---v---s. \ j--f--- FG. 2. Different field-gradient-pulse schemes for VOSY experiments. The curly brackets indicate equal intervals. sequence shown in Fig. 2 (version (a)). n order to ensure the perfect suppression especially of the C, echo, the G, gradient has been extended into the 72 interval according to the dashed line in Fig. 2. We thus have taken advantage of the fact that the C2 signal is insensitive to the length and strength of any gradient applied during the 72 interval. The experiments were carried out with a Bruker BMT 24/40 in viva NMR spectrometer operating at 100 MHz proton resonance frequency. The magnet bore diameter was 40 cm. A phantom sample was used consisting of a cubic array of 33 spherical plastic vessels with a diameter of 24 mm. The vessel in the center was filled with benzene; the surrounding spheres contained water (Fig. 3).

382 COMMUNCATONS Figure 4 shows the 100 MHz one-scan H spectra selectively recorded in cubic volume elements (about (3 mm)3) subsequently located at positions in the benzene, water, and interstitial space area, respectively, as indicated in Fig. 3. n this experiment the shape of the selective RF pulses was Gaussian for simplicity. The intervals were 71 = 25 ms and 72 = 67 ms. The signal intensities correctly reflect the H densities in the three space areas. The H densities of water and benzene are related as 2.1: 1.O. The suppression of signals originating from the space outside the selected volume elements was complete. Note that, once the position of the sensitive volume element has been calibrated to the field gradients, any location can immediately be predetermined by calculating the corresponding frequencies of the RF pulses. Thus the spectra in Fig. 4 represent onetrial experiments. The VOSY method has some remarkable advantages compared with other techniques: (a) The complete suppression of signals not originating from the selected volume element can be reached in a one-scan experiment. (b) There is only minor saturation of spins located outside of the observed volume element (namely those within the three perpendicular slices) so that a series of nonoverlapping volume elements can be investigated subsequently without any delay. f the reading pulse (P3 in Fig. 1) is replaced by a sequence of reading pulses, a distribution of volume elements along a line defined by the first two slices in principle can be scanned with a rate equal to the reciprocal acquisition. (c) The average RF power irradiated during one scan is intrinsically small and is expected to cause no complication under in vivo conditions. A certain limitation for nuclei with short T2 value is given by the signal reduction due to the T2-sensitive intervals of the sequences, namely the 71 periods. n the test experiments described above the typical T2-sensitive per scan was chosen to be 27, = 50 ms. This can be reduced to the minimum needed for the gradient changes. At the present state of the art the T2-sensitive then would be about 30 ms for version (a) and somewhat less for version (b) of the C2-selective gradient-pulse sequence (Fig. 2). Thus the technique will not be very advantageous for 3 P spectroscopy. For proton resonance, on the other hand, the weakening of the water signal due to the short T2 is quite desirable. The minimum 72 value is about 7.5 ms for the same reason as in the case of TV. Practically it will not limit the applicability of the VOSY method particularly in the C2 version where this interval is governed by spin-lattice relaxation. FE. 3. Mid-cross section of the phantom sample used in the test experiment. Central sphere: benzene; surrounding spheres: water. Diameter of the spheres: 24 mm; size of the selected volume elements: (3 mm)3.

COMMUNCATONS 383 0.0 PPM a/------ 0.0 PPM ll 0.0 PPM FG. 4. Application of the C, VOSY three-pulse sequence (Figs. 1 and 2) to volume-selective H spectroscopy of the volume elements indicated in Fig. 3 (, water;, benzene;, interstitial space). The spectra are onescan records with identical amplifier and vertical display settings. The zero position of the parts per million scale is arbitrary. Because the pulse scheme in Fig. 1 is based on 90 refocusing pulses, the amplitude of the C2 echo is reduced by a factor of 0.5, that of the C, echo even by a factor of 0.25 compared with a two-pulse echo refocused by a 180 pulse. On the other hand, in a given more signals (of different volume elements) can be recorded than with the other volume-selective techniques which saturate all nuclei outside of the volume element under investigation. Thus, if one is interested in spectra of a series of volume elements all at once, as is likely the case in medical applications, the VOSY technique is expected to be effectively more sensitive. The pulse scheme in Fig. 1 implies a series of special experiments promising the combination of spectroscopic and other information. We propose the following modifications based on the observation of the volume-selective echoes C1 or Cz.

384 COMMUNCATONS (a) Variation of 71 or formation of additional echoes by adding further 180 pulses in order to permit records of stacked plots of T2-weighted C1 or C2 spectra. (b) Variation of T2 in order to permit records of stacked plots of Tr-weighted C2 spectra. (c) Addition of equal gradient pulses with varying amplitudes in the intervals P r... P2 and P3... C2 in order to permit records of D-weighted stimulated echoes (7) (D self-diffusion is the coefficient). The data then can be represented as stacked plots of D-weighted C2 spectra. (d) Variation of one selective pulse in order to permit records of stacked plots of Cr or C2 spectra distributed along a line defined by the other two selective pulses. (e) Adding the DEPT pulse sequence (8, 9) where the first heteronuclear 90 pulse is replaced by the Cr or C2 echo, in order to permit records of sensitivity-enhanced and volume-selective 13C spectra (or of other proton-coupled nuclei). (f) Choosing 71 = (4.) (Jis a typical proton-proton coupling constant) in order to permit water and lipid signal suppression by multiple-quantum filtering (O). (g) Suppression of signals from uncoupled spins (e.g., water protons) can also be achieved by choosing 7, = (4J)- and applying selective heteronuclear pulses simultaneously with the second and third RF pulses (modified spin-echo double-resonance technique). The homonuclear version of the SEDOR technique can also be considered (). Note that proposals (b) and (d) can also be carried out in a single scan by a sequence of reading pulses shorter than 90 (3). ACKNOWLEDGMENTS We thank Dipl.-Phys. B. Kntittel for the continuous support and discussions in the course of this work. The experiments reported and proposed above are part of a research project sponsored by the Bundesministerium fti Forschung und Technologie (Grant 01 VF 85 203). REFERENCES. W. P. AUE, S. MOLLER, R. A. CROSS, AND J. SEELG, J. Magn. Reson. 56,350 (1984). 2. R. J. ORDDGE, A. CONNELY, AND J. A. B. LQHMAN, J. Mngn. Reson. 66,283 (1986). 3. D. M. DODDRELL, W. M. BROOKS, J. M. BULSNG, J. FELD, M. G. RVMG, AND H. BADDELEY, J. Magn. Reson. 68,367 (1986). 4. W. SATTN, T. H. MAREC, AND K. N. SCOTT, J. Magn. Reson. 64, 177 ( 1985). 5. J. FRAHM, K. D. MERBOLDT, W. HXNCKE, AND A. HAASE,. Magn. Reson. 64,81 (1985). 6. E. L. HAHN, Phys. Rev. 80,580 (1950). 7. J. E. TANNER, J. Chem. Phys. 52,2523 (1970). 8. D. M. DODDRELL, D. T. PEGG, AND M. R. BENDALL, J. Magn. Reson. 48,322 (1982). 9. W. P. AUE, S. MOLLER, AND J. SEELG, J. Mugn. Reson. 61, 392 (1985). O. C. L. DUMOULN, J. Magn. Reson. 64,38 (1985).. D. L. ROTHMAN, F. ARJASMENDOZA, G.. SHULMAN, AND R. G. SHULMAN, J. Magn. Reson. 60,430 (1984).