Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Similar documents
Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. Switch Power Rail

Assembly. Front view. Switch Power Rail

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

Assembly. Front view. Power Rail

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Assembly. Front view. Parametrization interface. Power Bus

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

Isolating Repeater Input Series 9163

Binary Output Series 9175

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

Binary Output without Power Supply Series 9176

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Technical Data. General specifications. Rated operating distance s n 3 mm

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Isolators A3/1.

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Temperature Input Module for Zone 1 Series 9482/32

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Digital Input Output Module for Zone 2 Series 9470/33

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Analog Universal Module HART for Zone 2 Series 9468/33

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Digital Input Output Module for Zone 1 Series 9470/32

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Digital Input Output Module for Zone 2 Series 9470/33

Remote I/O. 74 Remote I/O. Remote I/O System

Temperature Transmitter itemp RTD DIN rail TMT 127

Isolators A3/1.

Inductive sensor slot-type SI2-K08-AP7

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Technical Information Barrier RB223

Level Limit Switch nivotester FTL 325 P

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Single-Channel Safety Barriers Series 9001

Digital I/O Coupler (4-wire) Series 9413/21

Type Nominal voltage (V) Code HSV V

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

itemp HART DIN rail TMT112

Fieldbus Isolating Repeater Series 9185/11

Temperature transmitter itemp PCP DIN rail TMT 121

Positioner with HART Communication Type 3780

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Temperature Measurement

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Signal conditioner - MACX MCR-UI-UI-NC

Level Limit Switch nivotester FTL 370, FTL 372

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

RMA42. Technical Information

Temperature transmitter itemp RTD DIN rail TMT 127

Technical Information RMA42

Remote Switching Unit nivotester FTL 320

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

0 2 1 â Ó. itemp HART TMT182. Technical Information

SALES SERVICE +358 (0)

Temperature Measurement Transmitters for mounting in sensor head

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

Temperature Measurement Transmitters for mounting in sensor head

SINEAX B 811 Power Pack with additional Functions

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Temperature head transmitter itemp PCP TMT 181

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

0 2 1 â Ó. itemp HART TMT182. Technical Information

Temperature head transmitter itemp TC TMT 188

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

Temperature Measurement

Two-channel safety barriers Series 9002

Rail mounted Temperature Transmitter TH102/TH102-Ex

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Operating Instructions

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Two-channel safety barriers Series 9002

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

TTH200 Head-mount temperature transmitter

SINEAX TI 807 Passive DC signal isolator

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

SINEAX TV809, 1 channel Programmable Isolating Amplifier

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX

MINI MCR-SL-UI-I-LP-NC

onlinecomponents.com

itemp PA TMT184 Technical information

Transcription:

Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC 6508/IEC 65 Function This isolated barrier is used for intrinsic safety applications. It transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area. The proximity sensor or switch controls a form C changeover relay contact for the safe area load. The barrier output changes state when the input signal changes state. The normal output state can be reversed using switch. Switch is used to enable or disable line fault detection of the field circuit. During an error condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE44. Front view LED yellow: Relay output LED red: LB/SC 4 5 6 OUT CHK PWR I 7 8 9 0 3 4 5 Removable terminal blue LED green: Power supply Switch (mode of operation) Switch (no functions) Switch (LB/SC-monitoring) Removable terminals green Connection Zone 0,, Div., 0 kω 400 Ω R kω 0 kω + + 3-7 8 9 4 5 30 V AC

General specifications Signal type Digital Input Functional safety related parameters Safety Integrity Level (SIL) SIL Supply Connection terminals 4, 5 Rated voltage U r 07... 53 V AC, 45... 65 Hz Power dissipation W Power consumption W Input Connection side field side Connection terminals +, +, 3- Rated values acc. to EN 60947-5-6 (NAMUR) Open circuit voltage/short-circuit current approx. 8 V DC / approx. 8 ma Switching point/switching hysteresis..... ma / approx. 0. ma Line fault detection breakage I 0. ma, short-circuit I > 6 ma Pulse/Pause ratio 0 ms / 0 ms Connection side control side Connection terminals 7, 8, 9 signal ; relay Contact loading 53 V AC/ A/cos φ > 0.7; 6.5 V AC/4 A/cos φ > 0.7; 40 V DC/ A resistive load Energized/De-energized delay approx. 0 ms / approx. 0 ms Mechanical life 0 7 switching cycles Transfer characteristics Switching frequency < 0 Hz Galvanic isolation Input/ Input/power supply /power supply Indicators/settings Display elements LEDs Labeling space for labeling at the front Directive conformity Electromagnetic compatibility Directive 04/30/EU EN 636-:03 (industrial locations) Low voltage Directive 04/35/EU EN 600-:00 Conformity Electromagnetic compatibility NE :006 Degree of protection IEC 6059:00 Input EN 60947-5-6:000 Ambient conditions Ambient temperature -0... 60 C (-4... 40 F) Mechanical specifications Degree of protection IP0 Connection screw terminals Mass approx. 50 g Dimensions 0 x 9 x 5 mm (0.8 x 4.7 x 4.5 inch), housing type B Mounting on 35 mm DIN mounting rail acc. to EN 6075:00 Data for application in connection with hazardous areas EU-Type Examination Certificate PTB 00 ATEX 08 Marking ()G [Ex ia Ga] C ()D [Ex ia Da] IC I (M) [Ex ia Ma] I Input Ex ia Voltage U o 0.6 V Current I o 9. ma Power P o 5 mw (linear characteristic) Supply Maximum safe voltage U m 53 V AC (Attention! U m is no rated voltage.) Contact loading 53 V AC/ A/cos φ > 0.7; 6.5 V AC/4 A/cos φ > 0.7; 40 V DC/ A resistive load Maximum safe voltage U m 53 V AC (Attention! The rated voltage can be lower.)

Galvanic isolation Input/ safe electrical isolation acc. to IEC/EN 60079-, voltage peak value 375 V Input/power supply safe electrical isolation acc. to IEC/EN 60079-, voltage peak value 375 V Directive conformity Directive 04/34/EU EN 60079-0:0+A:03, EN 60079-:0 International approvals FM approval Control drawing 6-0035 UL approval Control drawing 6-045 CSA approval Control drawing 6-0047 IECEx approval IECEx PTB.003 Approved for [Ex ia Ga] C, [Ex ia Da] IC, [Ex ia Ma] I General information Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. 3

Configuration Switch position 4 5 6 OUT CHK PWR S Function Position Mode of operation with high input current I I (relay) with low input current energized no function 3 Line fault detection ON I OFF 7 8 9 0 3 4 5 I Operating status Control circuit Initiator high impedance/ contact opened Initiator low impedance/ contact closed Lead breakage, lead short-circuit Input signal low input current high input current Line fault Factory settings: switch, and 3 in position I 4

Maximum switching power of output contacts Resistive load DC Resistive load AC I (A) 4 Electrical life max. 0 5 switching cycles 0.5 Electrical life max..5 x 0 5 switching cycles 0. 0 40 00 00 5 50 U (V) The maximum number of switching cycles is depending on the electrical load and may be higher when reduced currents and voltages are applied. 5