Installation Manual REbus Beacon. Part of the Pika Energy Island M

Similar documents
I n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0

I n s t a l l a t i o n M a n u a l. T E D P r o L i t e A B C. f o r. Shop for The Energy Detective products online at: Rev 3.

APS M1P Single-phase Micro-inverter Installation and User Manual

Instruction Manual. for Media Monkey. 1

Disclaimers. Important Notice

INSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48

Make sure you have these items handy

APS M1P Single-phase Micro-inverter Installation and User Manual

Installation/User Manual

Quick Start Guide. Contents

Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular)

Signal Mirror Installation Instructions Honda Odyssey

Installation Instructions

Copyright Next Wave Automation All Rights Reserved. Version SEPTEMBER Updates of this manual are Available at

Disclaimers. Important Notice

BMW E90 Android Touch Screen Radio Installation Instructions

DS Series Printer: Clearing a Cutter Jam

Signal Mirror Installation Instructions

ET Water SmartWorks Panel Installation Guide

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

(Wireless Solution)

MRI SIMULATOR PST OPERATOR MANUAL

V00029KX READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID

Signal Mirror Installation Instructions

Signal Mirror Installation Instructions Toyota Tacoma

MODULAR LED UNDERCABINET LIGHTING SYSTEM Max 540watts IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions

The Lutron Quick Reference Guide

AMANO. Electronic Calculating Time Recorder. Setup and Operations Manual

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

See Page 8 for Part Numbers

Broadband Step-Up Transformer. User Manual

Variable Refrigerant Flow (VRF) System Simple Touch Remote Control SAFETY WARNING

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

2 LSS Addendum N O L I M I T

Monitor mount for 2017 P-series Dell monitors. Installation guide

IEM 200 R UHF receiver. user manual

ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /

Vinyl Cutter Instruction Manual

Installing the 3 Indexer: PRS Standard Tools

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

Flat Sample Holder Part Number

A Channel Amplifier

TM5. Guide Book. Hardware Version: 2.00 Software Version: 1.62

* For best quality print using Fit To Page setting in printer dialog box. SERVICE MANUAL CHGCT36

Agilent U1231A/U1232A/U1233A Handheld Multimeter. Quick Start Guide

BL-ER-P Ethernet Radio Unit for Pedestal Installation Guide

Ford Mustang, SVT, Cobra

WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

USER MANUAL ENGLISH 1450 COIN COUNTER & SORTER

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

Field Service Spares Procedure Replacement Coax Switch Kit, 8897B, 9497B, 14400B, ST88, ST94 & ST144

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

Table of Contents. Product Spec cations

2015 RIGOL TECHNOLOGIES, INC.

EA SPORTS MADDEN NFL SEASON 2 Cabinet Upgrade Instructions

S&C Scada-Mate Switching Systems Outdoor Distribution Interrupter Replacement 14.4 kv through 34.5 kv

Always there to help you. Register your product and get support at AJ7045D. Question? Contact Philips.

INSTALLATION MANUAL DASH. friant.com/dash

KANEKA OLED Lighting Module SL (LE-01L, LE-02L, LE-03L, LE-01H, LE-02H, LE-03H) Instruction Manual

BMW E39/E53 Android Touch Screen Radio Installation Instructions

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Radio Control Installation and Operating Instructions System 4

INSTALLATION MANUAL VERITY. friant.com/verity

Field Hub Installation Guide. P/N Rev. C 05/15

Remote Control Outlets Operating Instructions

Install Guide. EMPower03 Power Monitor 1.1

Signal Mirror Installation Instructions Dodge Charger, Dodge Magnum, Chrysler 300

I NSTALLATION M ANUAL

VESDA Technical Tip. Upgrade of the VLF-250 to support. VESDAnet Interface Card

Keysight U1231A/ U1232A/U1233A Handheld Multimeter. Quick Start Guide

User Manual. Smart-UPS On-Line. Uninterruptible Power Supply. Isolation Transformer Models: SURT001 and SURT002

MEQ15BT. INSTALLATION / OWNER'S MANUAL Wireless Smart EQ Processor FCC ID : GJW-SBT504 IC ID : 4038A-SBT504

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

TESS I. Wireless Control System. Installation and User Manual. RPM Control Company Toll Free 1

F-Series Trucks - Ford Full Size Bronco - Ford

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

Radio System Strobe Wizard Plus Freemask

DM 800H Twin Handheld UHF System (863.0Mhz-865.0Mhz)

Setup Guide. support.spruceirrigation.com.

Taurus - Ford Sable - Mercury

INSTALLATION INSTRUCTIONS ATV WINCH MULTI-MOUNT Multi-Mount Mounting-Kit: PN Application: YAMAHA BIGBEAR 00+

Monitor mount for 2016 E-series and E2417H Dell monitors. Installation guide

PERSONAL RECORD KEEPING

LIEBERT ITA2 MBC Quick-Start Guide 60Hz, 208V, 8-10kVA, Three-Phase

Signal Mirror Installation Instructions

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS

Standard PS-P61 Punch Stapler

Blue Point Engineering

Mirage Installation Manual

Maintenance Information

Guide To Returning Your Satellite Modem and Radio Assembly Model: HN9000

Notification System Installation Guide

STRUCTURE SENSOR QUICK START GUIDE

Installation Instructions. Materials Needed. Parts Included. Tools You Will Need

Instruction Manual. Quick Setup

Transcription:

Installation Manual REbus Beacon Part of the Pika Energy Island M00020-01

REbus Beacon Serial Number: RCP Number:

We are committed to quality and constant improvement. All specifications and descriptions contained in this document are verified to be accurate at the time of printing. However, we reserve the right to make modifications at any time that may result in a change of specification without notice in our pursuit of quality. If you find any inconsistencies or errors in this document, please notify us at sales@pika-energy.com Check the resources tab at www.pika-energy.com for the latest specifications and manuals. 12/19/17 Pika Energy, Inc. All rights reserved. All information in this document is subject to copyright and other intellectual property rights of Pika Energy, Inc. This material may not be modified, reproduced or copied, in whole or in part, without the prior written permission of Pika Energy, Inc. and its licensors. Additional information is available upon request. REbus Beacon Installation Manual M00020-01 3

About This Manual Section 1: Introduction About This Manual This Installation Manual provides instructions for adding the REbus Beacon to a Pika Energy Island system. Use these instructions for retrofits or for new installations. If installing Beacon as part of a new Energy Island installation, install and commission all other parts of the system before attempting to use Beacon. The companion document to this installation manual is the REbus Beacon Operation Manual. Please reference the Operation Manual for information on user configurable settings, including the Time of Use (TOU) Scheduler. Symbols used in this Manual WARNING: This indicates a fact or feature very important for the safety of the user to prevent injury or death and/or which can cause serious hardware damage if not applied appropriately. CAUTION: Presents information to prevent damage to this product EARTH GROUND SYMBOL 4 REbus Beacon Installation Manual M00020-01

Section 2: Safety Information Section 2: Safety Information General Warnings SHOCK RISK: HIGH VOLTAGE ELECTRICITY WARNING: To reduce the risk of injury, read all instructions and caution markings before installing Beacon. Consult installation documentation for all other REbus devices on the system. WARNING: Beacon must be installed by trained and qualified technicians, and in accordance with all instructions. WARNING: Electrical installation in the United States shall be done in accordance with all local electrical codes and/or the National Electrical Code (NEC), ANSI/NFPA 70. WARNING: Electrical installation in Canada shall be done in accordance with all local electrical codes and/or the Canadian Electrical Code. WARNING: Connecting the Pika Energy Island to the electric utility grid must only be done after receiving prior approval from the utility company and installation completed only by qualified personnel/licensed electrician(s). WARNING: This equipment is NOT intended for use with life support equipment or other medical equipment or devices. WARNING: Disconnect all smart batteries and turn their Battery Disconnect switches to OFF before servicing the inverter or touching electrical terminals. Refer to smart battery documentation for complete safety instructions. REbus Beacon Installation Manual M00020-01 5

Instructions Section 3: Installing Beacon Contents of Shipping Box New wiring compartment cover with REbus Beacon attached Ethernet and power cable assembly USB type-a to type-b cable ¾ plastic split-ring grommet Spare mounting screws for wiring compartment cover Tools needed #2 phillips screwdriver for wiring compartment cover #0 phillips screwdriver for screw terminals Instructions Power down the Energy Island system 1. Initiate a Safety Shutdown to de-energize the Energy Island system by holding the red Shutdown button on the inverter front cover. This will disable energy sources on the REbus DC nanogrid. The inverter screen will display the system DC voltage; wait until it falls to a safe level before proceeding. 2. Turn off the AC breaker feeding the inverter to disconnect AC power from the system. 3. Disconnect all DC power sources by turning off their breakers. WARNING: Disconnect all smart batteries and turn their Battery Disconnect switches to OFF before servicing the inverter or touching electrical terminals. Refer to smart battery documentation for complete safety instructions. 4. Remove the wiring compartment cover. 5. Check that all terminals are de-energized before proceeding. Pro Tip: You no longer need the old wiring compartment cover. You can save it as a spare, recycle it, or hang it next to your desk for quick reference! 6 REbus Beacon Installation Manual M00020-01

Section 3: Installing Beacon Install the ethernet and power cable assembly 1. Connect the power leads to the black 16-pin accessory terminal block. i. Connect the red wire (labeled 5V ) to the 5V terminal on the accessory terminal block. ii. Connect the black wire (labeled GND ) to the GND terminal of the accessory terminal block. Fig 1. Connect the power leads to the GND and 5V terminals black 16-pin accessory terminal block. 2. Connect the female ethernet connector to the internet. i. Locate the incoming ethernet cable that connects the inverter to the internet. It is connected to the ethernet port located behind the DC wiring terminals. Unplug the incoming ethernet cable from this location. ii. Connect the incoming ethernet cable to the female ethernet connector at the end of the Beacon ethernet and power cable assembly. Install the new wiring compartment cover with Beacon attached 1. Pass the ethernet and power cable assembly through the passthrough opening at the top of the cover. 2. Attach the cover using the wiring compartment cover screws. REbus Beacon Installation Manual M00020-01 7

Instructions Connect the ethernet and power cable assembly to Beacon 1. Connect the ethernet cable to the ethernet port on the top face of Beacon. 2. Connect the power cable to the micro USB port on the right-hand face of Beacon, near the bottom. 3. Feed any slack wire back through the passthrough into the wiring compartment. Keep all wires neatly managed. Connect the USB cable 1. The type-b (square shaped) connector plugs in to a port inside the inverter Power Core. Remove the black plastic plug from the ¾ hole in the bottom center of the Power Core cover to access the port and plug in the cable 2. Connect the type-a (rectangular shaped) connector to the back right-hand port on the top face of Beacon. 3. Slip the plastic split-ring grommet over the USB cable, then snap it into place in the Power Core cover. 8 REbus Beacon Installation Manual M00020-01

Section 4: Commissioning Beacon Section 4: Commissioning Beacon Note: If this is a new Energy Island installation, follow all commissioning procedures for the Islanding Inverter and all connected REbus devices before continuing. For complete information on powering on and commissioning the inverter, using the inverter front control panel, and working safely with the Islanding Inverter, refer to the Islanding Inverter Installation and Operation Manuals. For information on commissioning and configuring other REbus devices, refer to individual device documentation. Commissioning Beacon consists of three steps: 1. Power on the system and verify connections 2. Enable all REbus devices 3. Configure Beacon Step 1: Power on the system and verify connections 1. Power on the Islanding Inverter by turning on the AC breaker. 2. If prompted, follow the on screen directions to exit the Safety Shutdown. 3. Use the left and right arrow buttons to scroll through the device pages. Verify that there is a Beacon device page. 4. Make sure the blue Internet LED on the front of the inverter is illuminated. If the LED is not illuminated, navigate to the inverter Ethernet Settings page and Disable ethernet. Step 2: Enable all REbus devices 1. Turn on the DC breakers for each connected device. 2. Enable the inverter, wait a few seconds for it to connect to the other devices, then enable each device. 3. Turn the front Battery Disconnect switch ON for each smart battery. Note: Refer to the Islanding Inverter Operation Manual for more information on enabling devices. 4. Navigate to the Ethernet Settings page on the inverter control panel and disable Ethernet. Refer to the Islanding Inverter Installation Manual for more information on enabling and disabling ethernet. REbus Beacon Installation Manual M00020-01 9

Instructions Step 3: Configure Beacon 1. Return to the Beacon device page. 2. Enter the Settings menu to access all settings, including the Time of Use (TOU) schedule and time zone. Note: Refer to the REbus Beacon Operation manual for complete instructions on navigating the menus and adjusting settings. 3. Beacon will immediately enable and begin running the TOU schedule. Section 5: Troubleshooting Problem: There is no REbus Beacon device page on the inverter front control panel. Check that Beacon s power cable is plugged in to Beacon, the power wires are secure in their terminals inside the wiring compartment, and their polarity is correct. Check for voltage at the power terminals; verify there is 5V between them. The 16-pin accessory terminal block is removable. Push gently on the terminal block to make sure it is fully seated in its socket. Check that the USB cable is connected at both ends. Be certain that it is correctly connected to the port inside the Power Core. Problem: The Inverter isn t connecting to the server. Make sure the Ethernet Settings page on the inverter control panel reads Disabled. Make sure all ethernet connections are secure. If using a field-built cable for your connection, check that the cable is made correctly. If your system requires manual DHCP setup, contact Pika Energy for assistance. Note: Pika Energy does not recommend or support connection to the internet using a wifi bridge or router set up in bridge mode. The Islanding Inverter does not communicate reliably through this type of device. Use these devices at your own discretion. Technical Support Information Support department hours: 9AM to 5PM Eastern Time, Monday Friday (excluding holidays) Phone: (207) 808-0362 Email: support@pika-energy.com 10 REbus Beacon Installation Manual M00020-01

Section 5: Troubleshooting REbus Beacon Installation Manual M00020-01 11

www.pika-energy.com 35 Bradley Drive #1 Westbrook, Maine 04092