M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Similar documents
Amplifier / controller electronics

via connection «Digital input» requires the Wandfluh USB adapter PD2

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Rudder or propeller angular position transmitter KINAX WT720

Resistance thermometer Model TR30, compact design

Technical Data. General specifications. Rated operating distance s n 3 mm

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Field indicator for current loops with HART communication Models DIH50, DIH52

DENISON HYDRAULICS Proportional Pressure Control Valves

INSTRUCTION MANUAL (ATEX / IECEx)

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Field indicator for current loops with HART communication Models DIH50, DIH52

Binary Output Series 9175

Binary Output without Power Supply Series 9176

Miniature resistance thermometer Model TR33, thread-mounted

Positioner with HART Communication Type 3780

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Analog amplifier RA. RE Edition: Replaces:

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Isolators A3/1.

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Technical Information Nivector FTC968, FTC968Z

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

OPTIWAVE 1010 Technical Datasheet

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Electronic amplifier type EV1D

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital Input Output Module for Zone 1 Series 9470/32

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Submersible pressure sensor For oils and fuels Model LF-1

Technical Specification FLUXUS ADM 8x27

SINEAX TV809, 1 channel Programmable Isolating Amplifier

Isolators A3/1.

Submersible pressure sensor For water and wastewater Model LW-1

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

SALES SERVICE +358 (0)

Local control stations for Zone 1 and Zone 21. Features. Description

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

Resistance thermometer Model TR30, compact design

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Proportional Directional Control Valves Nominal sizes 16 and 25

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Drive electronics pq11

Resistance thermometer Model TR30, compact design

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Digital Input Output Module for Zone 2 Series 9470/33

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS

Coriolis Massflowmeter

General Specifications

CROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights

KINAX WT 717 Programmable Transmitter for Angular Position

ED701 General Industry Pressure Transmitter

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

OEM radar transmitter, for aggressive media level measurement

Direct Operated Proportional DC Valve Series D1FP

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

0 2 1 â Ó. itemp HART TMT182. Technical Information

Ultrasonic level measuring device, non-contact

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Signal Beacon - LED Series 6162

2/2-Way Solenoid Control Valve

Fieldbus Isolating Repeater Series 9185/11

IP26 Series Current to Pneumatic Converter

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Analog Universal Module HART for Zone 2 Series 9468/33

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Temposonics. Magnetostrictive Linear Position Sensors. TH SSI Data Sheet

Directional valves Coils Series CO1. Brochure

Coriolis Massflowmeter

Technical Specification FLUXUS ADM 8127B

Multiturn absolute encoder

Digital I/O Coupler (4-wire) Series 9413/21

KFS. Flap-type flow meter. Design and range of application

Load pin Heavy Duty with thin film technology from 10 kn Models F5308, F53C8, F53S1

Pressure transmitter AKS 32 and AKS 33

Transcription:

Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db IIC T6/T4 II 2 D Ex td A21 IP65 T80 C/T130 C I M2 Ex db I Mb DESCRIPTION For explosion-hazard zones Solenoid coil in acc. with directive 2014/34/EU (ATEX) for explosion-hazard zones. The flameproof enclosures (acc. to EN/IEC 60079-1/31) prevents an explosion in the interior from getting outside. The design prevents a surface temperature capable of igniting. The steel housing is zinc-/nickel-coated Optional with integrated amplifier electronics. CERTIFICATES FUNCTION In combination with an armature tube, the function of a switching solenoid or of a proportional solenoid results. Solenoid coils in AC construction have an integrated rectifier. All cable threaded joints certified for this explosion protection class with a protection class of at least IP65 can be used. The optional amplifier electronics have an analogue interface and can be adjusted by means of push-buttons and 7 segment display or by means of the parameterisation software PASO. APPLICATION The solenoid coil is suitable for use in all explosion-hazard zones, open cast and also in mines. This signifies, that the coils are certified for applications in zones with explosion-hazard gas, steam, vapour, air and dust mixtures of the zones 1/21 and 2/22. Valves for explosion-hazard zones are utilised in: the shipping- and offshore industries the oil- and gas industries the chemical industry wood processing grain mills the mining application Surface Mining Standard -25 C bis M224-40 C bis M238-60 C bis M248 Electronic Atex x x x x x x IECEx x x x x x x EAC x x x x x x Australia x x x x Inmetro x x x x x x Nepsi x x x x MA x x x The certificates can be found on www.wandfluh.com TYPE CODE M K Y / 18 x 60 - / / / - # Mobile execution, metal housing Terminal box without cable Explosion proof version Ex d Housing width mm Internal coil diameter 18 mm Coil length 60 mm Nominal voltage 12 VDC G 12 115 VAC R 115 24 VDC G 24 230 VAC R 230 Nominal power P N 9 W L 9 15W L15 21 W L 21 Certification ATEX, IECEx, EAC Australia AUS Inmetro IM NEPSI NP MA MA (only for G24 / L15) Cable gland M187 Thread NPT ½" Temperature range -25 C bis... -40 C bis... M224-60 C bis... M238 Function Amplifier M248 only G12 or G24 / up to max. L15 / not for M238 Freewheel diode M256 only G12 or G24 / do not use for proportional functions Bipolar protecting diode M264 only G24 Design-Index (Subject to change) Postfach Fax +41 33 672 72 12 Internet: www.wandfluh.com Data subject to change 1.1-183E 1/5

DIMENSIONS without amplifier electronics Ø 22 Ø18,2 20 M 20 x1,5 / NPT 1/2 22,5 42 93,3 CHARACTERISTICS Coil winding isolation class H Protection class acc. to EN 60529 Relative duty factor IP65/66/67, with corresponding cable gland and correct installation 100 % DF, combined with armature tube and valve Reference temperature Execution L9: -25 +40 C (operation as T1 T6/T80 C) -25 +90 C (operation as T1 T4/T130 C) Execution L15 / L12 Temperature range -25 to... -25 +70 C (operation as T1 T4/T130 C) Temperature range -40 to... -40 +70 C (operation as T1 T4/T130 C) Temperature range -60 to... -60 +70 C (operation as T1 T4/T130 C) : Execution L 21: -25 +50 C (operation as T1 T4/T130 C) At < 20V the max. ambient temperature has to be reduced by 10 C. Housing Relative humidity factor Corrosion protection Steel housing, zinc-/nickel-coated max. 95 % (not dew-forming) Salt spray test in accordance with EN ISO 9227 > = 1000 hours Maximum operating voltage Nominal voltage +10 % Nominal frequency in acc. with name plate ±2 % Standard nominal voltages Standard P N = 9 W nominal powers P N = 15 W P N = 21 W 1,4 = 12 VDC = 24 VDC = 115 VAC = 230 VAC Other nominal voltages in the ranges of 12 230 VDC and 24 230 VAC on request 60 12 VDC Nominal resistance (Ω) 16,5 13,5 9,9 7,1 Recommended rated 1600 2000 2'500 4'000 Limiting current (ma) 610 720 960 1'230 (Proportional function) 24 VDC Nominal resistance (Ω) 64 49,2 38,5 27,5 Recommended rated 800 800 1'250 2'000 Limiting current (ma) 300 370 0 600 (Proportional function) 115 VAC Nominal resistance (Ω) 1'180 869 700 500 Recommended rated 200 200 315 400 230 VAC Nominal resistance (Ω) 4'750 3'370 2'850 2'050 Recommended rated 100 100 160 200 Connection Option M256 (freewheel diode) + PE OPERATION SECURITY The solenoid coil must only be put into operation, if the requirements of the operating instructions supplied are observed to their full extent. In case of non-observance, no liability can be assumed. A corresponding fuse in accordance with its design current has to be connected in series as short-circuit protection for every solenoid coil. INSTALLATION For stack assembly please observe the remarks in the operating instructions. ACCESSORIES The operating instructions incl. the EC declaration of conformity for solenoid coils of the type MKY/18 x 60 is supplied in German, English and French Type test certifications EC-declaration of conformity Recognition of production quality assurance SEV 16 ATEX 4130 Postfach Fax +41 33 672 72 12 Internet: www.wandfluh.com Data subject to change 1.1-183E 2/5

With amplifier electronics and with analogue interface Digital amplifier electronics to MKY...M248 Electronics integrated in solenoid housing For proportional or switching valves Screw terminals for simple assembly Protection IP 65/66/67 1 analogue input 1 digital input Adjustable with push-buttons and display directly on the device or via PC ELECTRICAL SPECIFICATIONS Protection class IP 65/66/67 acc. to EN 60 529 Supply voltage G12: 12 V +10 %, G24: 24 V +10 % Residual ripple < +/-5 % Fuse low No-load current approx. 20 ma Max. current consumption No-load current + limiting current of the solenoid Analogue input 1 input non-differential Voltage / current (switchable by means of parameter) 0...+/- 10V or 0/4...20mA Resolution 10-Bit Input resistance Voltage input >100 kω (Input current < 5 ma) Load for current input = 124 Ω Stabilised output 5 VDC voltage max. load 20 ma Solenoid current: Minimal current I min Adjustable 0 I max ma Factory setting 30 ma Maximal current I max G24/L15 Adjustable I min 510 m A Factory setting 0 ma G12/L15 Adjustable I min 1020 m A Factory setting 960 ma DIMENSIONS with amplifier electronics G24/L9 Adjustable I min 510 m A Factory setting 600 ma G12/L9 Adjustable I min 685 m A Factory setting 610 ma Dither Frequency adjustable 4 500 Hz Factory setting 80 Hz Level adjustable 0 400 ma Factory setting 150 ma Temperature drift <1 % at T = 40 C Digital inputs 1 input high-active, no pull-up/down Switching threshold high 6...32 VDC Switching threshold low 0 1 VDC Usable as frequency input (frequency 5...5000 Hz) and as PWM input (automatic frequency recognition) USB interface Via digital input Requires the Wandfluh USB adapter PD2 EMC Immunity EN 61 000-6-2 Emission EN 61 000-6-4 X1 1 2 3 4 5 X1 1 2 3 4 5 42 M20 x1.5/npt 1/2" Ø 22 Ø18.2 124 up down enter 20 1.4 CONNECTOR ASSIGNMENT (X1) 1 = + VDC 2 = Command value 3 = Dig Inp 4 = Stab out 5 = 60 22.5 GENERAL SPECIFICATIONS Execution Electronics board built-in directly in solenoid housing Connections Screw terminal 5-pole, max. 1.0 mm 2 USB interface via connection «Digital Input», requires an additional Wandfluh adapter PD2 Postfach Fax +41 33 672 72 12 Internet: www.wandfluh.com Data subject to change 1.1-183E 3/5

BLOCK DIAGRAM +VCC X2-1 Internal supply Supply PWM Solenoid Stabilised output X1-4 A/D Analogue input Voltage or current A/D X2-2 Digital input Adapter USB-PD2 Push-buttons FLASH RAM 7 segment display PASO / USB START-UP Information regarding installation and commissioning are contained in the information leaflet supplied with the amplifier electronics and in the operating instructions. Additional information can be found on our website: «www.wandfluh.com» Free-of-charge download: «PASO-PD2» Parameterisation software Operating instruction (*.pdf) ADDITIONAL INFORMATION Wandfluh documentation Proportional spool valve register 1.10 Proportional pressure valves register 2.3 Proportional flow control valves register 2.6 ACCESSORIES USB adapter PD2 Article no. 726.9900 incl. USB cable type A-B, 1,8 m (for parameterisation via PASO) PARAMETER SETTINGS The MKY electronics have push-buttons and a display which enable setting the most important parameters. In addition, the digital input can be used as a communication interface, through which, by means of the parameterisation software "PASO-PD2", the complete parameterisation and diagnostics can be carried out. For this, the Wandfluh USB-PD2 adapter is required. (not included in the delivery) Attention: During the communication, the digital input cannot be used. FUNCTION DESCRIPTION Command value Command scaling Fixed command values Ramp generator Valve type Solenoid driver Solenoid output Current measurement DigInp DigInp DigInp DigInp Error Number Enable Solenoid Enable Error Postfach Fax +41 33 672 72 12 Internet: www.wandfluh.com Data subject to change 1.1-183E 4/5

AMPLIFIER WITH ANALOGUE INTERFACE Command value scaling The command value can be applied as a voltage, current, digital, frequency or PWM signal. The scaling takes place via the parameter Interface. Furthermore, the command value can be monitored for a cable break. A dead band can also be set. Fixed command value There is 1 fixed command value available, which can be selected via the digital input. This function has to be configurated before in PASO. Ramp generator Two linear ramps for up and down are available which can be adjusted separately. Valve type Adjustment possibilities: switching solenoid or proportional solenoid. Mode of operation Command value unipolar/bipolar (1-Sol) Dependent on a command value signal (voltage, current, digital, frequency or PWM), the solenoid is driven (e.g. 0.10V correspond to 0.100 % command value, 0.+100 % command value correspond to Imin.Imax solenoid driver) Signal recording Furthermore, the PD2 amplifier electronics have a signal recording function. This, by means of PASO, enables the recording of various system signals, such as command value, solenoid current, etc., which can be represented on a common time axis. Solenoid driver A Pulse-Width-Modulated current output is available. A dither signal is superimposed, whereby the dither frequency and the dither level are separately adjustable. The minimum (Imin) and maximum (Imax) current can be adjusted. The solenoid output can also be configurated as switching solenoid output. In this case, a power reduction can be adjusted. Optimisation of characteristic curve An adjustable characteristic curve Command value input solenoid current output enables an optimised (e.g. linearised) characteristic of the hydraulic system. Channel enabling The device is enabled as per factory setting. Via PASO or menu item, the digital input can the enabling can be set on, out or external (digital input). Hints: Digital input: if not wired, the state of the digital input is not defined Analogue input: if not wired, the voltage input will read 1.11 V constantly. 0 % 100 % Command value 0 V 10 V 4 ma 20 ma Analogue value 0 ma 20 ma 5 Hz 5000 Hz - 10 V 10 V CONNECTION EXAMPLES Supply voltage Supply voltage F F = Fuse low Analogue input with potentiometer X1-4 Digital input as function input USB/PASO Analogue input voltage with external voltage source 0...10 VDC +/-10 VDC 0...1 VDC 6...32 VDC Analogue input current with external current source 0...20 ma 4...20 ma Digital input as USB interface VCC PC PASO USB USB - Adapter ON TX RX DIG OV + VCC DigInp MKY Plug USB type B Screw Terminal Postfach Fax +41 33 672 72 12 Internet: www.wandfluh.com Data subject to change 1.1-183E 5/5