Ledex Tubular Linear Solenoids

Similar documents
Ledex Low Profile Linear Solenoids

BTA Rotary Actuators. Torque - mnm. 100% Duty Cycle. 25% Duty Cycle 5 50% Duty Cycle 2

Ledex Low Profile Linear Solenoids

Ultimag Rotary Actuators

Solenoid Data Book 1425 Lake Avenue Woodstock, IL Phone: (815) Toll Free: Sales Fax: (815)


Installation Instructions

From dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz).

SERIES WW24 Industrial Wirewound Rotary Potentiometer 24mm Diameter / 5 Watts

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

Ledex Drive Electronics and Coil Suppressors

Lok Fast Column Clamp General Information

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

SERIES 100 & 200 AXIAL LEADED RESISTORS

MA3. Miniature Absolute Magnetic Shaft Encoder Page 1 of 8. Description. Order Using #MA3 starting at $36.00 per unit. Features

Features. Continuous Duty Cycle Actuators

Installation Instructions. Installation Type

Installation Instructions. Installation Type

BOLTS AND NUTS Square Bolts( Table 1 ) Hex Nuts ( Table 7 ) Heavy Hex Nuts (Table 7) Heavy Hex Structural Bolts ( Table 2 )

Engineering Data Stock Ejectors

AGASTAT GP/ML/TR Series, 10 Amp Control Relay, Non-latching, Latching & Timing Versions

Index. Installation and Tools. Installation and Tools... Page

R30D RVDTs DC-Operated Rotary Variable Differential Transformers

MA3. Miniature Absolute Magnetic Shaft Encoder Page 1 of 8. Description. Mechanical Drawing. Features

Section 11 Electronic Position Controls & Encoders

RPE Parallel Gripper- Electric Gripper Series

Spring Return DuraDrive Proportional Actuator


ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Table of Contents. Kilovac Time Delay Relays

DynaPower Generation II

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

PPM-5710 JK HEAVY DUTY SKID PLATE ASSEMBLY Version 2.0

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

Series 291 Optical Encoder

TWIN ROD CYLINDERS 6 CONTENTS

PAK Drum Roll Top Assembly Instructions. Note: 2 people will be required to assemble roll top

PMT-L31 (for Low Ceilings) PMT-H35 (for High Ceilings)

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT RELAY TYPE. DPDT relay with internal diode for coil transient suppression

Replacement of Pitch Link Retainer and Service Improvement of the Pitch Control System. Effectivity: Helicopters manufactured prior to January, 1981

SMA - 50 Ohm Connectors

Why Use. Stock Ejectors. The New Industry Standard

LEG CURL IP-S1315 INSTALLATION INSTRUCTIONS

SLIDE SHAFT PRODUCTS. 777 Schwab Road, Suite T, Hatfield, PA Toll Free: Fax:

CALRAD 25 series - potentiometers

How To Use This Catalog

AHU. Specifications. Materials. Ordering Information E UL Approved Illuminated Pushbutton. page 1

SMA 50 Ohm Connectors Alphabetical Index INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE ON REQUEST

Micro-Change. Cordset Family

Sold & Serviced By: ELECTROMATE. Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099

Linear Hook- on Worksurfaces

Model 97 & 99-5/8 Square Single-Turn Panel Control with Rotary Switch

Type SCR Commutating Capacitors

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

Installation Instructions

INSTALLATION TORSION SPRING FRONT OR REAR MOUNT LOW HEADROOM. 1 Cutting Vertical Track. 2 Fully Adjustable Jamb Brackets

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

KRPA, KRP, KA, KR series

Slim compact safety relay

Rotary Position Technology Incremental Encoders

Rotary Measurement Technology Incremental Encoders

Parts Catalog. S-Series Slicer Smart Manual SG13. Model:

Band-Master ATS Nano Pneumatic Banding Tool Operating Instructions

Techline Flat Cross Splice. Techline Yoke Clamps* Techline Gang Clamps* TECHLINE. *Yoke Clamps Are Available To Fit Any Width.

Mill Specifications. FEATURE 5000(5100) 5400(5410) 2000 (2010) Max clearance, table to spindle

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Chapter Tests and Problems

TO-5 RELAYS ESTABLISHED RELIABILITY MILITARY DPDT

NORTH AMERICA ONLY PIPE SLUG CHUTE DETAILS ALL DIMENSIONS IN INCHES

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

TO-5 RELAYS ESTABLISHED RELIABILITY MILITARY DPDT

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Compact Actuator DRL Series

DRILLING CATALOG. GRAINGER.COM/CHOICE l Grainger

Fully Sealed Container Cermet Potentiometers Military and Professional Grade

Nuclear Qualified Control Relays Series EGP/EML/ETR

MS Connector: (Voltage or Current Output) Pin No. Extension Cable Function. Wire Color. MS Connector: (Start/Stop or PWM) Wire Color WIRING: + A

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

C9209 PRESENTATION. DIMENSIONS (in mm) SINGLE ELEMENT ROTARY - SIZE 09 PRECISION POTENTIOMETER

(1) Method to fix Mechanically with BOLT or NUT

Screws. Introduction. 1. Nuts, bolts and screws used to clamp things together. Screws are used for two purposes:

AGASTAT E7000 Series, Nuclear Qualified Time Delay Relays

JR12 Jam Nut Mount Optical Encoder

AUXILIARY FRAMING AND ACCESSORIES

HD25. Industrial Rugged Metal Optical Encoder Page 1 of 6. Description. Mechanical Drawing. Features

Mobile Weapons Storage System Specifications

Assembly, Installation, Operation and Maintenance Instructions Kit, Base Rail Bracket Part # 31852

Standard Pole Mount Parabolic Antenna Mounting Instructions 3 ft. (90cm) & 4 ft. (120cm)

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

.093 [2.36] Commercial Pin and Socket Connectors

DCM20 Series. Three-Function DC Power Meters. DCM20 DISPLAY PRODUCT OVERVIEW FEATURES

Oxford Stalls Installation Instructions

XXXX e. X d.. X X X a

SLIM COMPACT SAFETY RELAY

1. This is an integrated product combining a bearing with a rotation sensor that detects the speed and direction of rotation.

Transmission Line Support Systems

Advanced Modeling Techniques Sweep and Helical Sweep

XXXX e. X d.. X X X a

Transcription:

Ledex Tubular Linear Solenoids Force lbs. (newtons) 10 (.) (35.5) 6 (6.69) (17.79) 10% Duty Cycle 70W 5% Duty Cycle W 50% Duty Cycle 1W 100% Duty Cycle 7W saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

Ledex Tubular Solenoids STA Series has enhanced design features and improved performance Push and pull models Strokes up to 1 " Life rating of 5 million actuations for STA designs Performance Curves Duty Cycle The Ledex STA Series of tubular solenoids is available in three sizes of 1/", 3/" and 1" diameter. Both push and pull types are available. Additionally, each size and type is available with a choice of two plunger configurations: flat face and 60, as well as with or without an anti-rotation flat on the mounting bushing. These options offer maximum force for a wide range of applications. The new design also improves performance and provides longer life than previous tubular designs. They offer quiet operation and improved reliability for demanding applications. Design Considerations Pull versus Push Type In Pull type solenoids, the plunger is pulled into the solenoid coil when the coil is energized. In Push type solenoids, the same is true, however, the plunger has a shaft extension which then pushes out through a hole in the end of the solenoid case. Please note, however, that the magnetic field cannot be reversed to cause the opposite action to occur. Plunger Pull Type De-energized Energized The performance curves in this section serve as guides to determine the solenoid size needed to produce a desired force at a given stroke, duty cycle, and power source. All curves were developed under the following standard test conditions: ambient temperature of C, 65% relative humidity. Starting Force When determining an application s force requirement, apply a 1.5 safety factor. For example: a load requiring.5 lb of force should utilize a solenoid providing.5 x 1.5 or 6.75 lb of force. Push Type Plunger De-energized Energized Shaft Extension Duty cycle is determined by: ON time/(on + OFF time). For example: a solenoid is actuated for 30 seconds, then off for 90 seconds. 30 sec ON / (30 Sec ON + 90 sec OFF) = 30/1 = 1/ or 5% duty cycle. Ledex tubular solenoids are rated for various duty cycles ranging from continuous to 10% duty. Note that maximum ON time for a particular application can be a factor which overrides the duty cycle rating. For example, at 5% duty cycle, the maximum ON time for a given Ledex solenoid is 36 seconds. If, however, the solenoid is operated at a cycle rate which enables the unit to return to ambient temperature between ON cycles, then the maximum ON time is extended somewhat. In the above example, this extended ON time is seconds. Maximum ON time ratings are listed on the individual model specification pages. E saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

Ledex Tubular Solenoids Life When selecting a tubular solenoid, as with any other solenoid style, it is important to consider the effects of heat on life. When used with a constant voltage supply, an increase in coil temperature reduces the work output and the life of the unit. Standard life is 5,000,000 actuations for STA designs. Power Requirements Voltage applied to the solenoid must be matched to the coil wire size for proper operation. Solenoids are cataloged in coil awgs ranging from #3 up to #37 to accommodate your input power. Refer to the individual model specification pages for coil wire awg recommendations. Many other coil awg sizes are available. Please feel free to contact our application engineering department for availability. Tubular Applications The STA Series is particularly ideal for applications where field service is prohibitive. Its long life and high reliability are definite advantages in applications involving: Computer peripherals Industrial sewing machines Automated teller machines Blood analyzers Gate mechanisms Packaging machinery Door interlocks Sorting machines Glue dispensers Laboratory equipment Business machines STA Construction The STA is constructed with a low friction nylon bobbin which insures a 5 million actuations life rating on all models. The problems associated with powdered metal flaking in typical tubular designs is eliminated with the metal-to-plastic bearing surface. In addition, the new design s case is rolled over both ends of the unit for greater shock and vibration integrity, allowing the STA to withstand severe applications in which typical solenoids may come apart. Both push and pull models offer a built-in combination air gap spacer and plunger stop. This feature eliminates the need for external E-rings and impact washers which typically fail prematurely, as well as get in the way of your attached mechanisms. All units are provided with 10" PVC lead wires as standard, and are rated for a maximum coil temperature of 130 C. ULapproved materials are used in the construction. For higher temperature applications up to 10 C, please consult the factory for alternate materials which are available in some models. Mechanical and electrical ratings may also be affected. Other options include: special plunger configurations, springs, special mounting features, and anti-rotation flats on mounting bushings. Please consult the factory with details about your application as tooling may apply to some features. STA Plunger Configurations With two standard plunger configurations to choose from, the new STA Series offers stroke lengths up to 0.70" and up to pounds of force. A. Flat Face Force A B A: Flat Face Stroke Flat Face (10 ) For strokes typically less than 0.060", the flat face plunger is recommended with a pull or push force three to five times greater than 60 plungers. B. 60 Angle For longer strokes up to 0.750", the 60 plunger offers the greatest advantage over the flat face plunger. 60 C: 60 Cone Size 15, 150, 175 Standard Tubular Models for Large Loads Ledex Size 15, 150, and 175 standard tubular models are offered for heavy duty applications requiring larger forces. These standard models are all pull type and offered with 60 plungers. These models feature heavy duty welded mounting brackets, and heavy duty plunger stops to limit plunger travel, provide positive stopping, and keep pole faces from slamming together at the end of stroke. An impact cushion made of resilient non-magnetic material absorbs energy at the end of the stroke. This cushion also helps eliminate residual magnetism. Size 15, 150, and 175 models are available with other plunger configurations, in push type models, and with other mountings. Please consult the factory as tooling may apply. saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E3

Ledex Tubular Solenoids Selection Tubular solenoids are available in seven sizes. The three STA Series sizes are available in both push and pull types. Use the selection overview chart to determine which size offers the desired performance and mechanical specifications. Refer to the individual size specification pages for complete performance and mechanical data. Tubular Selection Overview Package Max Nominal Force (lbs) @ Nominal Stroke Solenoid Dimension (in) Stroke Stroke and Specified Duty Cycle Size Type Dia. Length (in) (in) 100% 50% 5% 10% STA 1 " x 1 " Pull 5 0.10 0.05 0.1 0.30 0 1.0 STA 1 " x 1 " Push 5 0.10 0.05 0.0 0.1 5 0.6 STA 1 " x 1" Pull 1.05 9 0.31 6 1.00 STA 1 " x 1" Push 1.05 3 5 0. 0.9 STA 3 " x 1 1 " Pull 0.77 1.56 0.70 0 0 1.00 1.63.69 STA 3 " x 1 1 " Push 0.77 1.56 0.70 0 0.3 0.0 1.50.75 STA 1" x " Pull 1.0.05 0.70 0.30 0.90 1.75 3.00 5. STA 1" x " Push 1.0.05 0.70 0.30 0.75 1..90 5. 1 1 " x 1 " Pull 1.5.5 0.75 0.0 1.00.00.00 6.50 1 1 " x 1 " Pull 1.50.50 0.75 0.0 1.00.50 5. 9.0 1 3 " x 3 " Pull 1.75.71.50 1.00 1.5.50 3.75 6.50 All data is at C coil temperature. Force outputs degrade with elevated temperatures. How to Use Tubular Performance Charts 1. Select one of the four columns which provides the appropriate duty cycle. (For example 50%.). Reading down this column provides a variety of performance and electrical data including maximum on time, watts, and amp turns. 3. Following down the column further into the VDC ratings, select the voltage which most closely matches your supply voltage. (For example, 11.5 for a 1 VDC power supply.). Read across (to the left) to select the awg suffix. (In this example, 3 awg is required, thus to order, specify: 1953-3. Note that the digit preceding the awg refers to the plunger configuration and anti-rotation flat selected. Review the STA plunger section on page E3 and on the individual specification page to select the appropriate plunger configuration. Note: The size 15, 150 and 175 standard models do not use this plunger configuration and anti-rotation flat suffix system. Performance Maximum Duty Cycle 100% 50% 5% 10% Maximum ON Time (sec) 50 5 when pulsed continuously Maximum ON Time (sec) 10 30 for single pulse Watts (@ C) 16 0 Ampere Turns (@ C) 97 70 99 1573 Coil Data awg Resistance # VDC VDC VDC VDC (0XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom) 7 1.3 306. 3.. 7.6 1.95 3. 3.9 5.6. 9 3. 50 3.9 5.5 7. 1. 30 5.9 57.6 6.5 9. 1.5 31 9.56 795 6.. 1. 19.6 3 16.5 106.1 11.5 16.3 5.7 33.60 119 9.5 13. 19.0 30.0 3 37.1 157 1. 17.3.0 39.0 35 60.71 1976 15.6.0 31.0 9.0 36 96.19 75 19.6.0 39.0 6.0 37 19.93 3060.5 35.0 9.0 77.0 E saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

Ledex Tubular Solenoids Design Modifications Options and Modified Designs Even though many solenoid designs are in stock and available via distribution, our customers often require a product with unique features or performance capabilities. In fact, almost 0% of all solenoids that we make are either modified or custom built to meet our customers exact application requirements. So, if you don t find what you re looking for in the catalog, give us a call to discuss your needs with one of our application engineers. Typical Examples of Custom Features Elliptical Flatted Drilled hole Threaded rod Clevis-grooved Clevis-tongue Notched Tapped hole saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E5

STA Pull Tubular Solenoids 1 " Dia. x 1 " Part Number: 1950 - X XX Coil AWG Number (from performance chart below) Plunger Configurations and anti-rotation flat on mounting 60 plunger without anti-rotation flat 6 60 plunger with anti-rotation flat Performance Maximum Duty Cycle 100% 50% 5% 10% Maximum ON Time (sec) 50 5 when pulsed continuously 1 Maximum ON Time (sec) 10 30 for single pulse Watts (@ C) 3 6 1 30 Ampere Turns (@ C) 6 379 536 7 Coil Data awg Resistance # VDC VDC VDC VDC (0XX) 3 (@ C) Turns (Nom) (Nom) (Nom) (Nom) 7 0. 10 1. 1.7. 3. 0.67 13 1.5.1.9.6 9 1.33 1 1.9.7 3.9 6.1 30 1.0. 3.3.7 7.5 31 3.33 90 3.1. 6. 9.7 3.57 35 3. 5.3 7.5 11.9 33 7.0 3. 6. 9.7 15.3 3 13.10 567 6.. 1. 19.6 35 17.0 630 7.6 11.0 15.0.0 36 9.05 0 9.6 1.0 19.0 30.0 37 5.70 100 1. 17.0.0 3.0 1 Continuously pulsed at stated watts and duty cycle Single pulse at stated watts (with coil at ambient room temperature C) 3 Other coil awg sizes available please consult factory Reference number of turns Specifications Dielectric Strength 500 VRMS Recommended Maximum watts dissipated by solenoid Minimum Heat Sink are based on an unrestricted flow of air at C, with solenoid mounted on the equivalent of an aluminum plate measuring square by 1 thick Coil Resistance ±5% tolerance Weight 1 oz (1.5 gms) Dimensions Ø" x 5" L (See page E5) How to Order Add the plunger configuration, anti-rotation flat number, and the coil awg number to the part number (for example: to order a unit with a 60 plunger configuration without an anti-rotation flat rated for 5 VDC at 5% duty cycle, specify 1950-30. Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. E6 saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

STA Pull Tubular Solenoids 1 " Dia. x 1 " Pull Tubular Solenoid 1 " dia. x 1 " 60 Plunger 0 (11.1) 3 (.90) Typical Force @ C Typical Speed @ No Load, C 100% Duty Cycle 50% Duty Cycle 5% Duty Cycle 10% Duty Cycle Force - oz. (newtons) (6.67) 16 (.5) 10% Duty Cycle 5% Duty Cycle 50% Duty Cycle 100% Duty Cycle Speed ms 16 1 (.) 0 0 0.05 (0.6) 0.050 (1.7) 0.075 (1.91) Stroke - in (mm) 0.100 (.5) 0.15 (3.1) 0 0.0 () 0.0 0.06 (1.0) (1.5) 0. (.0) 1.0 (.5) saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E7

STA Push Tubular Solenoids 1 " Dia. x 1 " Part Number: 1951- X XX Coil AWG Number (from performance chart below) Plunger Configurations and anti-rotation flat on mounting 60 plunger without anti-rotation flat 6 60 plunger with anti-rotation flat Performance Maximum Duty Cycle 100% 50% 5% 10% Maximum ON Time (sec) 50 5 when pulsed continuously 1 Maximum ON Time (sec) 10 30 for single pulse Watts (@ C) 3 6 1 30 Ampere Turns (@ C) 6 379 536 7 Coil Data awg Resistance # VDC VDC VDC VDC (0XX) 3 (@ C) Turns (Nom) (Nom) (Nom) (Nom) 7 0. 10 1. 1.7. 3. 0.67 13 1.5.1.9.6 9 1.33 1 1.9.7 3.9 6.1 30 1.0. 3.3.7 7.5 31 3.33 90 3.1. 6. 9.7 3.57 35 3. 5.3 7.5 11.9 33 7.0 3. 6. 9.7 15.3 3 13.10 567 6.. 1. 19.6 35 17.0 630 7.6 11.0 15.0.0 36 9.05 0 9.6 1.0 19.0 30.0 37 5.70 100 1. 17.0.0 3.0 1 Continuously pulsed at stated watts and duty cycle Single pulse at stated watts (with coil at ambient room temperature C) 3 Other coil awg sizes available please consult factory Reference number of turns Specifications Dielectric Strength 500 VRMS Recommended Maximum watts dissipated by solenoid Minimum Heat Sink are based on an unrestricted flow of air at C, with solenoid mounted on the equivalent of an aluminum plate measuring square by 1 thick Coil Resistance ±5% tolerance Weight 1 oz (1.5 gms) Dimensions Ø" x 5" L (See page E5) How to Order Add the plunger configuration, anti-rotation flat number, and the coil awg number to the part number (for example: to order a unit with a 60 plunger configuration without an anti-rotation flat rated for 5 VDC at 5% duty cycle, specify 1951-30. Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. E saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

STA Push Tubular Solenoids 1 " Dia. x 1 " Push Tubular Solenoid 1 " dia. x 1" 60 Plunger Typical Force @ C Typical Speed @ No Load, C 1 (5.00) 15 (.17) 100% Duty Cycle 50% Duty Cycle 5% Duty Cycle 10% Duty Cycle Force - oz. (newtons) 1 (3.3) 9 (.50) 6 (1.66) 10% Duty Cycle 5% Duty Cycle 50% Duty Cycle 100% Duty Cycle Speed ms 16 1 3 (0.3) 0 0 0.05 (0.6) 0.050 (1.7) 0.075 (1.91) Stroke - in (mm) 0.100 (.5) 0.15 (3.1) 0 0.0 () 0.0 0.06 (1.0) (1.5) 0. (.0) 1.0 (.5) saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E9

STA Pull Tubular Solenoids 1 " Dia. x 1" Part Number: 195 - X XX Coil AWG Number (from performance chart below) Plunger Configurations and anti-rotation flat on mounting 1 Flat face plunger without anti-rotation flat 60 plunger without anti-rotation flat 5 Flat face plunger with anti-rotation flat 6 60 plunger with anti-rotation flat Performance Maximum Duty Cycle 100% 50% 5% 10% Maximum ON Time (sec) 50 5 when pulsed continuously 1 Maximum ON Time (sec) 10 30 for single pulse Watts (@ C) 16 0 Ampere Turns (@ C) 97 70 99 1573 Coil Data awg Resistance # VDC VDC VDC VDC (0XX) 3 (@ C) Turns (Nom) (Nom) (Nom) (Nom) 7 1.3 306. 3.. 7.6 1.95 3. 3.9 5.6. 9 3. 50 3.9 5.5 7. 1. 30 5.9 57.6 6.5 9. 1.5 31 9.56 795 6.. 1. 19.6 3 16.5 106.1 11.5 16.3 5.7 33.60 119 9.5 13. 19.0 30.0 3 37.1 157 1. 17.3.0 39.0 35 60.71 1976 15.6.0 31.0 9.0 36 96.19 75 19.6.0 39.0 6.0 37 19.93 3060.5 35.0 9.0 77.0 1 Continuously pulsed at stated watts and duty cycle Single pulse at stated watts (with coil at ambient room temperature C) 3 Other coil awg sizes available please consult factory Reference number of turns Specifications Dielectric Strength 500 VRMS Recommended Maximum watts dissipated by solenoid Minimum Heat Sink are based on an unrestricted flow of air at C, with solenoid mounted on the equivalent of an aluminum plate measuring square by 1 thick Coil Resistance ±5% tolerance Holding Force Flat Face:1.1 lb (5.5 N) @ C 60 :0.90 lb (.00 N) @ C Weight 0.7 oz (.7 gms) Plunger Weight 0.16 oz (.5 gms) Dimensions Ø" x 1.05" L (See page E6) How to Order Add the plunger configuration, anti-rotation flat number, and the coil awg number to the part number (for example: to order a unit with a 60 plunger configuration without an anti-rotation flat rated for 5 VDC at 5% duty cycle, specify 195-7. Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. E10 saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

STA Pull Tubular Solenoids 1 " Dia. x 1" Pull Tubular Solenoid 1 " dia. x 1" Flat Face Plunger (13.3) 0 (11.1) Typical Force @ C 10% Duty Cycle 0W 5% Duty Cycle 16W 50% Duty Cycle W 100% Duty Cycle W Typical Speed @ No Load, C 100% Duty Cycle W 50% Duty Cycle W 5% Duty Cycle 16W 10% Duty Cycle 0W Force oz. (newtons) 3 (.90 (6.67) 16 (.5) Speed ms 16 1 (.) 0 0.05 (1.7) 0.10 0.15 (.5) (3.1) 0 (5.0) 5 (6.35) 0 0.05 (1.7) 0.10 0.15 (.5) (3.1) 0 (5.0) 5 (6.35) Pull Tubular Solenoid 1 " dia. x 1" 60 Plunger Force oz. (newtons) 3 (.90) (6.67) 16 (.5) (.) Typical Force @ C 10% Duty Cycle 0W 5% Duty Cycle 16W 50% Duty Cycle W 100% Duty Cycle W Speed ms 60 50 0 30 10 Typical Speed @ No Load, C 100% Duty Cycle W 50% Duty Cycle W 5% Duty Cycle 16W 10% Duty Cycle 0W 0 0.1 (.5) 0.3 (5.0) (7.6) 0. (10.16) 0 0.1 (.5) 0.3 (5.0) (7.6) 0. (10.16) saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E11

STA Push Tubular Solenoids 1 " Dia. x 1" Part Number: 1953 - X XX Coil AWG Number (from performance chart below) Plunger Configurations and anti-rotation flat on mounting 1 Flat face plunger without anti-rotation flat 60 plunger without anti-rotation flat 5 Flat face plunger with anti-rotation flat 6 60 plunger with anti-rotation flat Performance Maximum Duty Cycle 100% 50% 5% 10% Maximum ON Time (sec) 50 5 when pulsed continuously 1 Maximum ON Time (sec) 10 30 for single pulse Watts (@ C) 16 0 Ampere Turns (@ C) 97 70 99 1573 Coil Data awg Resistance # VDC VDC VDC VDC (0XX) 3 (@ C) Turns (Nom) (Nom) (Nom) (Nom) 7 1.3 306. 3.. 7.6 1.95 3. 3.9 5.6. 9 3. 50 3.9 5.5 7. 1. 30 5.9 57.6 6.5 9. 1.5 31 9.56 795 6.. 1. 19.6 3 16.5 106.1 11.5 16.3 5.7 33.60 119 9.5 13. 19.0 30.0 3 37.1 157 1. 17.3.0 39.0 35 60.71 1976 15.6.0 31.0 9.0 36 96.19 75 19.6.0 39.0 6.0 37 19.93 3060.5 35.0 9.0 77.0 1 Continuously pulsed at stated watts and duty cycle Single pulse at stated watts (with coil at ambient room temperature C) 3 Other coil awg sizes available please consult factory Reference number of turns Specifications Dielectric Strength 500 VRMS Recommended Maximum watts dissipated by solenoid Minimum Heat Sink are based on an unrestricted flow of air at C, with solenoid mounted on the equivalent of an aluminum plate measuring square by 1 thick Coil Resistance ±5% tolerance Holding Force Flat Face:1.00 lb (.5 N) @ C 60 :0.71 lb (3.16 N) @ C Weight 0.9 oz (5. gms) Plunger Weight 0.11 oz (3.1 gms) Dimensions Ø" x 1.05" L (See page E6) How to Order Add the plunger configuration, anti-rotation flat number and the coil awg number to the part number (for example: to order a unit with a 60 plunger configuration without anti-rotation rated for 5 VDC at 5% duty cycle, specify 1953-7. Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. E1 saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

STA Push Tubular Solenoids 1 " Dia. x 1" Push Tubular Solenoid 1 " dia. x 1" Flat Face Plunger Force oz. (newtons) 3 (.90) (6.67) 16 (.5) (.) Typical Force @ C 10% Duty Cycle 0W 5% Duty Cycle 16W 50% Duty Cycle W 100% Duty Cycle W Speed ms 16 1 Typical Speed @ No Load, C 100% Duty Cycle W 50% Duty Cycle W 5% Duty Cycle 16W 10% Duty Cycle 0W 0 0.05 (1.7) 0.10 0.15 (.5) (3.1) 0 (5.0) 5 (6.35) 0 0.05 (1.7) 0.10 0.15 (.5) (3.1) 0 (5.0) 5 (6.35) Push Tubular Solenoid 1 " dia. x 1" 60 Plunger Force oz. (newtons) 3 (.90) (6.67) 16 (.5) (.) Typical Force @ C 10% Duty Cycle 0W 5% Duty Cycle 16W 50% Duty Cycle W 100% Duty Cycle W Speed ms 60 50 0 30 10 Typical Speed @ No Load, C 100% Duty Cycle W 50% Duty Cycle W 5% Duty Cycle 16W 10% Duty Cycle 0W 0 0.1 (.5) 0.3 (5.0) (7.6) 0. (10.16) 0 0.1 (.5) 0.3 (5.0) (7.6) 0. (10.16) saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E13

STA Pull Tubular Solenoids 3 " Dia. x 1 1 " Part Number: 195 - X XX Coil AWG Number (from performance chart below) Plunger Configurations and anti-rotation flat on mounting 1 Flat face plunger without anti-rotation flat 60 plunger without anti-rotation flat 5 Flat face plunger with anti-rotation flat 6 60 plunger with anti-rotation flat Performance Maximum Duty Cycle 100% 50% 5% 10% Maximum ON Time (sec) 30 5 6 when pulsed continuously 1 Maximum ON Time (sec) 65 63 15 for single pulse Watts (@ C) 7 1 70 Ampere Turns (@ C) 55 10 1700 700 Coil Data awg Resistance # VDC VDC VDC VDC (0XX) 3 (@ C) Turns (Nom) (Nom) (Nom) (Nom) 1.10 330.7 3. 5.6. 5.13 3.9 5.5 7.7 1. 6.90 5.5 6. 9.0 1. 7 5.7 760 6.1.6 1.1 19. 9.15 106.0 11.3 16.0 5.0 9 1.50 116 9. 13. 1.7 30.0 30.70 191 1.0 17.0.0 3.0 31 33.60 190 15.0.0 31.0.0 3 53.50 39 19. 7.0 39.0 61.0 33 3.50 970.0 3.0.0 76.0 1 Continuously pulsed at stated watts and duty cycle Single pulse at stated watts (with coil at ambient room temperature C) 3 Other coil awg sizes available please consult factory Reference number of turns Specifications Dielectric Strength 1000 VRMS Recommended Maximum watts dissipated by solenoid Minimum Heat Sink are based on an unrestricted flow of air at C, with solenoid mounted on the equivalent of an aluminum plate measuring 3 square by 1 thick Coil Resistance ±5% tolerance Holding Force Flat Face:5. lb (3.31 N) @ C 60 :. lb (1.1 N) @ C Weight.95 oz (3.6 gms) Plunger Weight 0.71oz (.13 gms) Dimensions Ø0.77" x 1.56" L (See page E7) How to Order Add the plunger number and the coil awg number to the part number (for example: to order a unit with a 60 plunger configuration without an anti-rotation flat rated for 1 VDC at 5% duty cycle, specify 195-7. Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. E1 saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

STA Pull Tubular Solenoids 3 " Dia. x 1 1 " Pull Tubular Solenoid 3 " dia. x 1 1 " Flat Face Plunger Force lbs. (newtons) 10 (.) (35.5) 6 (6.69) (17.79) Typical Force @ C 10% Duty Cycle 70W 5% Duty Cycle W 50% Duty Cycle 1W 100% Duty Cycle 7W Speed ms 50 0 30 Typical Speed @ No Load, C 100% Duty Cycle 7W 50% Duty Cycle 1W 5% Duty Cycle W 10% Duty Cycle 70W (.90) 10 (.5) 0.3 (5.0) (7.6) 0. (10.16) (.5) 0.3 (5.0) (7.6) 0. (10.16) Pull Tubular Solenoid 3 " dia. x 1 1 " 60 Plunger Force lbs. (newtons) 6 (6.69) 5 (.) (17.79) 3 (13.3) (.90) 1 (.5) Typical Force @ C 10% Duty Cycle 70W 5% Duty Cycle W 50% Duty Cycle 1W 100% Duty Cycle 7W Speed ms 50 0 30 10 Typical Speed @ No Load, C 100% Duty Cycle 7W 50% Duty Cycle 1W 5% Duty Cycle W 10% Duty Cycle 70W (.5) (5.0) 0.3 0. (7.6) (10.16) 0.6 (15.) 0.7 (17.7) (.5) (5.0) 0.3 0. (7.6) (10.16) 0.6 (15.) 0.7 (17.7) saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E15

STA Push Tubular Solenoids 3 " Dia. x 1 1 " Part Number: 1955 - X XX Coil AWG Number (from performance chart below) Plunger Configurations and anti-rotation flat on mounting 1 Flat face plunger without anti-rotation flat 60 plunger without anti-rotation flat 5 Flat face plunger with anti-rotation flat 6 60 plunger with anti-rotation flat Performance Maximum Duty Cycle 100% 50% 5% 10% Maximum ON Time (sec) 30 5 6 when pulsed continuously 1 Maximum ON Time (sec) 65 63 15 for single pulse Watts (@ C) 7 1 70 Ampere Turns (@ C) 55 10 1700 700 Coil Data awg Resistance # VDC VDC VDC VDC (0XX) 3 (@ C) Turns (Nom) (Nom) (Nom) (Nom) 1.10 330.7 3. 5.6. 5.13 3.9 5.5 7.7 1. 6.90 5.5 6. 9.0 1. 7 5.7 760 6.1.6 1.1 19. 9.15 106.0 11.3 16.0 5.0 9 1.50 116 9. 13. 1.7 30.0 30.70 191 1.0 17.0.0 3.0 31 33.60 190 15.0.0 31.0.0 3 53.50 39 19. 7.0 39.0 61.0 33 3.50 970.0 3.0.0 76.0 1 Continuously pulsed at stated watts and duty cycle Single pulse at stated watts (with coil at ambient room temperature C) 3 Other coil awg sizes available please consult factory Reference number of turns Specifications Dielectric Strength 1000 VRMS Recommended Maximum watts dissipated by solenoid Minimum Heat Sink are based on an unrestricted flow of air at C, with solenoid mounted on the equivalent of an aluminum plate measuring 3 square by 1 thick Coil Resistance ±5% tolerance Holding Force Flat Face:.95 lb (.0 N) @ C 60 :.5 lb (1.6 N) @ C Weight 3.0 oz (7.3 gms) Plunger Weight 3 oz (15.03 gms) Dimensions Ø0.77" x 1.56" L (See page E7) How to Order Add the plunger number and the coil awg number to the part number (for example: to order a unit with a 60 plunger configuration without an anti-rotation flat rated for 1 VDC at 5% duty cycle, specify 1955-7. Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. E16 saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

STA Push Tubular Solenoids 3 " Dia. x 1 1 " Push Tubular Solenoid 3 " dia. x 1 1 " Flat Face Plunger Force lbs. (newtons) (35.5) 6 (6.69) (17.79) (.90) Typical Force @ C 10% Duty Cycle 70W 5% Duty Cycle W 50% Duty Cycle 1W 100% Duty Cycle 7W Speed ms 50 0 30 10 Typical Speed @ No Load, C 100% Duty Cycle 7W 50% Duty Cycle 1W 5% Duty Cycle W 10% Duty Cycle 70W (.5) 0.3 (5.0) (7.6) 0. (10.16) (.5) 0.3 (5.0) (7.6) 0. (10.16) Push Tubular Solenoid 3 " dia. x 1 1 " 60 Plunger Force lbs. (newtons) 6 (6.69) 5 (.) (17.79) 3 (13.3) (.90) Typical Force @ C 10% Duty Cycle 70W 5% Duty Cycle W 50% Duty Cycle 1W 100% Duty Cycle 7W Speed ms 50 0 30 Typical Speed @ No Load, C 100% Duty Cycle 7W 50% Duty Cycle 1W 5% Duty Cycle W 10% Duty Cycle 70W 1 (.5) 10 (.5) (5.0) 0.3 (7.6) 0. (10.16) 0.6 (15.) 0.7 (17.7) (.5) (5.0) 0.3 (7.6) 0. (10.16) 0.6 (15.) 0.7 (17.7) saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E17

STA Pull Tubular Solenoids 1" Dia. x " Part Number: 1956 - X XX Coil AWG Number (from performance chart below) Plunger Configurations and anti-rotation flat on mounting 1 Flat face plunger without anti-rotation flat 60 plunger without anti-rotation flat 5 Flat face plunger with anti-rotation flat 6 60 plunger with anti-rotation flat Performance Maximum Duty Cycle 100% 50% 5% 10% Maximum ON Time (sec) 360 3 when pulsed continuously 1 Maximum ON Time (sec) 70 1 3 for single pulse Watts (@ C) 10 0 100 Ampere Turns (@ C) 1166 169 33 36 Coil Data awg Resistance # VDC VDC VDC VDC (0XX) 3 (@ C) Turns (Nom) (Nom) (Nom) (Nom) 3 1.96 536. 6.3.9 1.0.69 600 5. 7.3 10. 16. 5.9 0 7.0 9.9 1.0.0 6. 11 9. 13.0 1. 9.0 7 11.50 160 10.7 15. 1.0 3.0 19. 165 13. 19.6.0.0 9 31. 10 17.7 5.0 35.0 56.0 30 9.60 66.0 31.0 5.0 70.0 31 77.0 30.0 39.0 56.0.0 3 119.00 06 35.0 9.0 69.0 109.0 33.00 5317 5.0 6.0 90.0 1.0 1 Continuously pulsed at stated watts and duty cycle Single pulse at stated watts (with coil at ambient room temperature C) 3 Other coil awg sizes available please consult factory Reference number of turns Specifications Dielectric Strength 1000 VRMS Recommended Maximum watts dissipated by solenoid Minimum Heat Sink are based on an unrestricted flow of air at C, with solenoid mounted on the equivalent of an aluminum plate measuring square by 1 thick Coil Resistance ±5% tolerance Holding Force Flat Face:13.3 lb (61.5 N) @ C 60 :6.61 lb (9.0 N) @ C Weight 6.96 oz (197.3 gms) Plunger Weight 1.60 oz (5.36 gms) Dimensions Ø1.0" x.05" L (See page E) How to Order Add the plunger configuration number and the coil awg number to the part number (for example: to order a unit with a 60 plunger rated for 1 VDC at 5% duty cycle, specify 1956-7. Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. E1 saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

STA Pull Tubular Solenoids 1" Dia. x " Pull Tubular Solenoid 1" dia. x " Flat Face Plunger Typical Force @ C Typical Speed @ No Load, C (1.5) (106.75) 10% Duty Cycle 100W 5% Duty Cycle 0W 50% Duty Cycle W 100% Duty Cycle 10W 50 0 100% Duty Cycle 10W 50% Duty Cycle W 5% Duty Cycle 0W 10% Duty Cycle 100W Force lbs. (newtons) (.96) 16 (71.17) 1 (53.3) (35.5) (17.79) Speed ms 30 10 (.5) 0.3 (5.0) (7.6) 0. (10.16) (.5) 0.3 (5.0) (7.6) 0. (10.16) Pull Tubular Solenoid 1" dia. x " 60 Plunger Force lbs. (newtons) 1 (53.3) 10 (.) (35.5) 6 (6.69) (17.79) Typical Force @ C 10% Duty Cycle 100W 5% Duty Cycle 0W 50% Duty Cycle W 100% Duty Cycle 10W Speed ms 50 0 30 Typical Speed @ No Load, C 100% Duty Cycle 10W 50% Duty Cycle W 5% Duty Cycle 0W 10% Duty Cycle 100W (.90) 10 (.5) (5.0) 0.3 0. (7.6) (10.16) 0.6 (15.) 0.7 (17.7) (.5) (5.0) 0.3 0. (7.6) (10.16) 0.6 (15.) 0.7 (17.7) saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E19

STA Push Tubular Solenoids 1" Dia. x " Part Number: 1957 - X XX Coil AWG Number (from performance chart below) Plunger Configurations and anti-rotation flat on mounting 1 Flat face plunger without anti-rotation flat 60 plunger without anti-rotation flat 5 Flat face plunger with anti-rotation flat 6 60 plunger with anti-rotation flat Performance Maximum Duty Cycle 100% 50% 5% 10% Maximum ON Time (sec) 360 3 when pulsed continuously 1 Maximum ON Time (sec) 70 1 3 for single pulse Watts (@ C) 10 0 100 Ampere Turns (@ C) 1166 169 33 36 Coil Data awg Resistance # VDC VDC VDC VDC (0XX) 3 (@ C) Turns (Nom) (Nom) (Nom) (Nom) 3 1.96 536. 6.3.9 1.0.69 600 5. 7.3 10. 16. 5.9 0 7.0 9.9 1.0.0 6. 11 9. 13.0 1. 9.0 7 11.50 160 10.7 15. 1.0 3.0 19. 165 13. 19.6.0.0 9 31. 10 17.7 5.0 35.0 56.0 30 9.60 66.0 31.0 5.0 70.0 31 77.0 30.0 39.0 56.0.0 3 119.00 06 35.0 9.0 69.0 109.0 33.00 5317 5.0 6.0 90.0 1.0 1 Continuously pulsed at stated watts and duty cycle Single pulse at stated watts (with coil at ambient room temperature C) 3 Other coil awg sizes available please consult factory Reference number of turns Specifications Dielectric Strength 1000 VRMS Recommended Maximum watts dissipated by solenoid Minimum Heat Sink are based on an unrestricted flow of air at C, with solenoid mounted on the equivalent of an aluminum plate measuring square by 1 thick Coil Resistance ±5% tolerance Holding Force Flat Face:11. lb (5.5 N) @ C 60 :6.9 lb (.7 N) @ C Weight 6.73 oz (190. gms) Plunger Weight 1.19 oz (33.7 gms) Dimensions Ø1.0" x.05" L (See page E) How to Order Add the plunger configuration number and the coil awg number to the part number (for example: to order a unit with a 60 plunger rated for 1 VDC at 5% duty cycle, specify 1957-7. Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. E saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

STA Push Tubular Solenoids 1" Dia. x " Push Tubular Solenoid 1" dia. x " Flat Face Plunger Typical Force @ C Typical Speed @ No Load, C (1.5) (106.75) 10% Duty Cycle 100W 5% Duty Cycle 0W 50% Duty Cycle W 100% Duty Cycle 10W 50 0 100% Duty Cycle 10W 50% Duty Cycle W 5% Duty Cycle 0W 10% Duty Cycle 100W Force lbs. (newtons) (.96) 16 (71.17) 1 (53.3) (35.5) (17.79) Speed ms 30 10 (.5) 0.3 (5.0) (7.6) 0. (10.16) (.5) 0.3 (5.0) (7.6) 0. (10.16) Push Tubular Solenoid 1" dia. x " 60 Plunger Force lbs. (newtons) 1 (53.3) 10 (.) (35.5) 6 (6.69) (17.79) Typical Force @ C 10% Duty Cycle 100W 5% Duty Cycle 0W 50% Duty Cycle W 100% Duty Cycle 10W Speed ms 50 0 30 Typical Speed @ No Load, C 100% Duty Cycle 10W 50% Duty Cycle W 5% Duty Cycle 0W 10% Duty Cycle 100W (.90) 10 (.5) (5.0) 0.3 0. (7.6) (10.16) 0.6 (15.) 0.7 (17.7) (.5) (5.0) 0.3 0. (7.6) (10.16) 0.6 (15.) 0.7 (17.7) saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E1

Ledex Size 15 Pull Tubular Solenoids 1 1 " Dia. x 1 " Part Number: 1719-0XX Performance Maximum Duty Cycle 100% 50% 5% 10% Maximum ON Time (sec) 390 60 1 when pulsed continuously 1 Maximum ON Time (sec) 510 160 5 for single pulse Watts (@ C) 13 6 5 130 Ampere Turns (@ C) 1500 11 3000 73 Coil Data awg Resistance # VDC VDC VDC VDC (0XX) 3 (@ C) Turns (Nom) (Nom) (Nom) (Nom) 3 3.5 70 6. 9.6 13.6.0 6.0 1056.6 1. 17. 7.0 5.7 1176 10.9 15..0 3.0 6 1.10 150 13. 19.5.0.0 7.50 1970 17.3.0 35.0 55.0 36.10.0 31.0.0 69.0 9 55.10 3060 7.0 3.0 5.0 6.0 30.10 305 35.0 9.0 70.0 110.0 31 17.00 50.0 6.0.0 139.0 3 1.00 599 5.0 76.0 107.0 170.0 33 35.00 77 69.0 9.0 13.0 1.0 1 Continuously pulsed at stated watts and duty cycle Single pulse at stated watts (with coil at ambient room temperature C) Specifications Dielectric Strength 1000 VRMS Recommended Maximum watts dissipated by solenoid Minimum Heat Sink are based on an unrestricted flow of air at C, with solenoid mounted on the equivalent of an aluminum plate measuring 5 square by 1 thick Coil Resistance ±5% tolerance Holding Force 9 lbs (0.03 N) @ C Weight 10.1 oz (95 gms) Dimensions Ø1.5" x.5" L (See page E9) How to Order Add the coil awg number (0XX) to the part number (for example: to order a 5% duty cycle unit rated at 35 VDC, specify 1719-07). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Size 15 Pull Typical Force @ C.0 (9.0) Size 15 Pull Typical Speed @ No Load, C 0 Force - lb (newtons) 15.0 (66.75) 10.0 (.50) 5.0 (.5) 10% Duty Cycle 130 W 5% Duty Cycle 5 W 50% Duty Cycle 6 W 100% Duty Cycle 13 W Time - ms 60 0 100% Duty Cycle 13 W 50% Duty Cycle 6 W 5% Duty Cycle 5 W 10% Duty Cycle 130 W 0 0 (.5) (5.1) 0.30 0.0 0 (7.6) (1) (1.7) Stroke - in (mm) 0.60 (15.) 0.70 (17.) 0 0 0.0 (5.0) (10.16) 0.60 (15.) Stroke - in (mm) 0.0 (.3) 1.00 (5.) E saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

Ledex Size 150 Pull Tubular Solenoids 1 1 " Dia. x 1 " Part Number: 173-0XX Performance Maximum Duty Cycle 100% 50% 5% 10% Maximum ON Time (sec) 100 5 when pulsed continuously 1 Maximum ON Time (sec) 570 5 75 for single pulse Watts (@ C) 17 3 6 170 Ampere Turns (@ C) 100 56 3600 569 Coil Data awg Resistance # VDC VDC VDC VDC (0XX) 3 (@ C) Turns (Nom) (Nom) (Nom) (Nom) 3 5.5 1030 9. 13.9 19.7 31.0 9.30 13 1. 17.6 5.0 39.0 5 1.90 171 15.7.0 31.0 50.0 6.00 10 19.9.0 0.0 63.0 7 36.90 60 5.0 35.0 50.0 79.0 5.0 33 3.0 5.0 63.0 100.0 9 7.50 00 39.0 56.0 79.0 1.0 30 1.00 59 50.0 71.0 101.0 159.0 31.00 6360 63.0 90.0 17.0 0.0 3 3.00 7956 7.0 110.0 155.0 6.0 33 55.00 10070 100.0 11.0 199.0 315.0 1 Continuously pulsed at stated watts and duty cycle Single pulse at stated watts (with coil at ambient room temperature C) Specifications Dielectric Strength 1000 VRMS Recommended Maximum watts dissipated by solenoid Minimum Heat Sink are based on an unrestricted flow of air at C, with solenoid mounted on the equivalent of an aluminum plate measuring 6 square by 1 thick Coil Resistance ±5% tolerance Holding Force 1.5 lbs (6.50 N) at C Weight 17 oz (1. gms) Dimensions Ø1.50" x.50" L (See page E9) How to Order Add the coil awg number (0XX) to the part number (for example: to order a 5% duty cycle unit rated at 50 VDC, specify 173-07). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Size 150 Pull Typical Force @ C.0 (9.0) Size 150 Pull Typical Speed @ No Load, C 0 Force - lb (newtons) 15.0 (66.75) 10.0 (.50) 5.0 (.5) 10% Duty Cycle 170W 5% Duty Cycle 6W 50% Duty Cycle 3W 100% Duty Cycle 17W Time - ms 60 0 100% Duty Cycle 17W 50% Duty Cycle 3W 5% Duty Cycle 6W 10% Duty Cycle 170W 0 0 (.5) (5.1) 0.30 0.0 0 (7.6) (1) (1.7) Stroke - in (mm) 0.60 (15.) 0.70 (17.) 0 0 0.0 (5.0) (10.16) 0.60 (15.) Stroke - in (mm) 0.0 (.3) 1.00 (5.) saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E3

Ledex Size 175 Pull Tubular Solenoids 1 3 " Dia. x 3 " Part Number: 1950-0XX Class 10 H UL Recognized Coil Insulation System UL File No. E131577 Performance Maximum Duty Cycle 100% 50% 5% 10% Maximum ON Time (sec) 9 5 when pulsed continuously 1 Maximum ON Time (sec) 1,0 5 16 for single pulse Watts (@ C) 0 0 0 Ampere Turns (@ C) 93 133 5 93 Coil Data awg Resistance # VDC VDC VDC VDC (0XX) 3 (@ C) Turns (Nom) (Nom) (Nom) (Nom) 3 1.60 5 17.1. 3. 5.0 3.30 3 1.6 3 3. 6.3 5 36.0 3990 7.0 3. 5.0 5.3 6 56. 906 33.5 7. 67.1 106.0 7 95.30 67 3.7 61.7 7.3 13.1 1.90 779 53.5 75.6 106.9 169.1 9 31.0 995 6.1 96.3 136. 15.3 30 36.0 1510 5. 11. 171.7 71. 31 575.0 155 107.3 151.7 1.6 339. 3 90 1995 137.1 193.9 7.3 33.6 33 1,5.00 15 16. 3.7 337.6 533.9 1 Continuously pulsed at stated watts and duty cycle Single pulse at stated watts (with coil at ambient room temperature C) 3 Other coil awg sizes available please consult factory Reference number of turns Specifications Dielectric Strength 1000 VRMS Recommended Maximum watts dissipated by solenoid Minimum Heat Sink are based on an unrestricted flow of air at C, with solenoid mounted on the equivalent of an aluminum plate measuring 10 square by 1 thick Coil Resistance ±5% tolerance Holding Force 1 lbs (0.06 N) @ C Weight.5 lb (1.0 kg) Dimensions Ø1.75" x.71" L (See page E30) How to Order Add the coil awg number (0XX) to the part number (for example: to order a 5% duty cycle unit rated at 7 VDC, specify 1950-07). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Size 175 Pull Typical Force @ C Force - lb (newtons) 5.0 (111.).0 (.96) 15.0 (66.7) 10.0 (.) 5.0 (.) 10% Duty Cycle 0W 5% Duty Cycle 0W 50% Duty Cycle 0W 100% Duty Cycle W Size 175 Pull Typical Speed @ No Load, C Time - ms 10 1 100 0 60 0 100% Duty Cycle W 50% Duty Cycle 0W 5% Duty Cycle 0W 10% Duty Cycle 0W 0 (1.7) 1.0 1.5 (5.) (3.1) Stroke - in (mm).0 (50.).5 (63.5) 0 (1.7) 1.0 (5.) 1.5 (3.1) Stroke - in (mm).0 (50.).5 (63.5) Force values for reference only. E saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

Ledex Tubular Solenoids Dimensions Inches (mm) STA Series Pull 1 " Dia. x 1 " 1.15 (.5) R Min. 0.15 ± 0.01 Flat (3.6 ± 0.30) 0.15 ± 0.01 (3.1 ± 0.30) Ø0.15 ± 0.003 (.70 ± 0.0) Ø0.15 ± 0.003 (.70 ± 0.0) 50 ± 0.01 (6.35 ± 0.30) Ø0.06 / 0.06 Thru (1.57 / 1.65) 6 ± 0.015 (1.7 ± 0.3) 50 (13.97) Max. 50 ± 0.010 (6.35 ± 5) Ø (13.) Max. Ø0.07 (1.9) Ref. 0.06 (1.57) 0.3750-3 UNCF Thd's STA Series Push 1 " Dia. x 1 " Mounting Nut: 0.09 (.3) thick x 0 (1.7) flats. Shipped as loose item. 10.00 Min. Leads (5.0) #6 AWG 0.15 ± 0.01 (3.6 ± 0.30) Flat Ø (13.1) Max. 00 ± 0.015 (1.70 ± 0.3) 50 (13.97) Max. 50 ± 0.010 (6.35 ± 5) Ø ( Ø0.06 ± 0.003 (1.57 ± 0.0) Mounting Nut: 0.09 (.3) thick x 0 (1.7) flats. Shipped as loose item. 0.3750-3 UNEF Thd's 10.00 Min. Leads (5.0) #6 AWG All solenoids are illustrated in energized state saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E5

Ledex Tubular Solenoids Dimensions Inches (mm) STA Series Pull 1 " Dia. x 1" 1.15 (.5) R min 0.0/0.30 x 5 ±5 Chamfer (1/0.76) 0.15 ± 0.010 (3.1 ± 0.30) 0.15 ±0.003 dia (Ø.70 ± 0.0) 50 ± 0.010 (6.35 ± 0.30) 0.06/0.065 dia thru (Ø1.57/1.65) 6 ± 0.015 (1.9 ± 0.3) 50 ± 0.010 (6.35 ± 0.30) 1.050 max (6.67) dia max (Ø13.1) 0.07 dia ref (Ø1.9) 0.15 (3.6) 0.06 (1.59) 0.3750 3 UNEF threads 0.050 min. panel thickness Mounting Nut: 0.09 (.3) thick x 0 (1.7) flats. Shipped as loose item. 10.0 min leads, (5.0) #6 awg STA Series Push 1 " Dia. x 1" dia max (Ø13.1) 0.750 ± 0.015 (19.05 ± 0.3) 1.050 (6.67) max 50 ± 0.010 (6.35 ± 0.30) 0.109 (.77) max 0.15 (3.6) 0.06 ± 0.003 dia (Ø1.59 ± 0.0) 0.3750 3 UNEF threads 0.050 min. panel thickness Mounting Nut: 0.09 (.3) thick x 0 (1.7) flats. Shipped as loose item. 10.0 min leads, (5.0) #6 awg All solenoids are illustrated in energized state E6 saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

Ledex Tubular Solenoids Dimensions Inches (mm) STA Series Pull 3 " Dia. x 1 1 " 1.15 (.5) R min Chamfer 0.0/0.30 (1/0.76) x 5 ±5 0.1 ± 0.010 (.76 ± 0.30) 0.30 ± 0.003 dia (Ø7. ± 0.0) 0.375 ± 0.010 (9.5 ± 0.30) 0.09/0.097 dia thru (Ø.3/.6) 0.750 ± 0.015 (19.05 ± 0.3) 0.375 ± 0.010 (9.5 ± 0.30) 1.550 (39.37) max 0.770 dia max (Ø19.56) 0.090 dia ref (Ø.9) 35 (5.97) 0.093 ± 0.010 (.36 ± 0.30) 65 1 UNF threads 0.05 min. panel thickness Mounting Nut: 0.13 (3.3) thick x 0.69 (17.5) flats. Shipped as loose item. 10.0 min leads, (5.0) # awg STA Series Push 3 " Dia. x 1 1 " 0.770 dia max (Ø19.56) 1.15 ± 0.015 (.5 ± 0.3) 0.375 ± 0.010 (9.5 ± 0.30) 1.550 (39.37) max 0.10 (3.56) max 35 (5.97) 0.09 ± 0.003 dia (Ø.39 ± 0.0) 65 1 UNF threads 0.05 min. panel thickness Mounting Nut: 0.13 (3.3) thick x 0.69 (17.5) flats. Shipped as loose item. 10.0 min leads, (5.0) # awg All solenoids are illustrated in energized state saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E7

Ledex Tubular Solenoids Dimensions Inches (mm) STA Series Pull 1" Dia. x " 1.15 (.5) R min 0.0/0.30 x 5 ±5 Chamfer (1/0.76) 0.31 ± 0.003 dia (Ø10.95 ± 0.0) 0.1 ± 0.010 (.76 ± 0.30) 0.375 ± 0.010 (9.5 ± 0.30) 0.15/0.19 dia thru (Ø3.1/3.) 0.750 ± 0.015.050 (19.05 ± 0.3) (5.07) max 0.375 ± 0.010 (9.5 ± 0.30) 1.0 dia max (Ø5.91) 0.156 dia ref (Ø3.97) 0.31 (7.9) 0.15 ± 0.010 (3.1 ± 0.30) 0.7500 16 UNF threads 0.100 min. panel thickness Mounting Nut: 0.16 (.1) thick x 0. (.) flats. Shipped as loose item. 10.0 min leads, (5.0) # awg STA Series Push 1" Dia. x " 1.0 dia. max (Ø5.91) 1.15 ± 0.015 (.5 ± 0.3).050 max (5.07) 0.375 ± 0.010 (9.5 ± 0.30) 0.10 (3.56) max 0.31 (7.9) 0.15 ± 0.003 dia (Ø3.1 ± 0.0) 0.7500 16 UNF threads 0.100 min. panel thickness Mounting Nut: 0.16 (.1) thick x 0. (.) flats. Shipped as loose item. 10.0 min leads, (5.0) # awg All solenoids are illustrated in energized state E saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6

Ledex Tubular Solenoids Dimensions Inches (mm) Ledex Size 15 Pull 1 1 " Dia. x 1 " Ledex Size 150 Pull 1 1 " Dia. x 1 " 0.05 (1.73) 0.71 + -+- (1.37 0.015 0.31) 0.05 (1.73) 0.3 + -+- (1.1 0.015 0.31) 0.656 (16.66) 1.656 (.06) 1.31 max (33.35) 1.5 + -+- (31.75 0.015 0.31) 0.656 (16.66) 1.656 (.06) 1.31 max (33.35) 1.50 + -+- (3.1 0.015 0.31) 0.1 + (3.657 + - 0.00 Chamfer 0.0/0.30-0.051) holes (1/0.76) x 5 ±5 0.17 00 + - (.79) (1.7 + 0.003-0.76) 0.375 (9.55) 0.17 + - 0.00 (3.6 + - 0.051) dia 0.156 (3.96) 0.31 + -+- (7.95 0.015 0.31) Chamfer 0.0/0.30 (1/0.76) x 5 ±5 0.65 + - (15.75 + 0.003-0.76) 0.17 + (3.6 + - 0.00-0.051) dia 0.156 (3.96) 0.1 + (3.657 + - 0.00-0.051) holes 0.17 (.79) 0.375 (9.55) 0.31 + -+- (7.95 0.015 0.31) 7 + -+- (1.61 0.015 0.31) 1.156 (9.36) 6.00 (15.) min leads # AWG PVC.5 + -+- (57.15 0.031 0.77) Plunger stop 0.703 + -+- (17.56 0.015 0.31) 1.156 (9.36) 6.00 (15.) min leads # AWG PVC.50 + -+- (63.5 0.031 0.77) Plunger stop All solenoids are illustrated in energized state saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6 E9

Ledex Tubular Solenoids Dimensions Inches (mm) All solenoids are illustrated in energized state Ledex Size 175 Pull 1 3 " Dia. x 3 " 0.16 (.7) ref 0.656 (16.66) 1.656 (.06) 1.31 max (33.33) 0.975 + -+- (.77 0.015 0.3) ref 1.750 + -+- (.5 0.015 0.3) Non-magnetic air gap spacer 0.0/0.30 x 5 ±5 Chamfer (1/0.76) 9 + (15.19 + - 0.003-0.76) 0.17 + (3.3 + - 0.00-0.05) dia 0.156 (3.96) 0.17 (.75) 0.375 (9.53) 0.31 + -+- (7.93 0.015 0.3) 1.156 (9.36) 3 ± 0.10 (1. ± 5).13 + (71.5 + - 0.010-5) 1.156 (9.36).707 (119.56) max #-3 UNC-B Thds () places.00 (50.0) min leads # AWG (Teflon) E30 saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex Fax: 1-937-9-6