Ledex Low Profile Linear Solenoids

Similar documents
Ledex Low Profile Linear Solenoids

Ledex Tubular Linear Solenoids

BTA Rotary Actuators. Torque - mnm. 100% Duty Cycle. 25% Duty Cycle 5 50% Duty Cycle 2

Ultimag Rotary Actuators

Solenoid Data Book 1425 Lake Avenue Woodstock, IL Phone: (815) Toll Free: Sales Fax: (815)



Compact Relay Family with Forcibly Guided Contacts

SERIES 100 & 200 AXIAL LEADED RESISTORS

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT RELAY TYPE. DPDT relay with internal diode for coil transient suppression

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

Shielded Power Inductors

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

AUTOMOTIVE RELAY WITH ISO TERMINAL ARRANGEMENT

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

SERIES WW24 Industrial Wirewound Rotary Potentiometer 24mm Diameter / 5 Watts

R30D RVDTs DC-Operated Rotary Variable Differential Transformers

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

TO-5 RELAYS ESTABLISHED RELIABILITY MILITARY DPDT

AGASTAT E7000 Series, Nuclear Qualified Time Delay Relays

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

Compact Flat Size Relay for Automotive. (Unit: mm inch)

TO-5 RELAYS ESTABLISHED RELIABILITY MILITARY DPDT

Ledex Drive Electronics and Coil Suppressors

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

Type SCR Commutating Capacitors

Transistor drive 2c/4c 5A slim power relays

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

MICRO-ISO AUTOMOTIVE RELAY

Types MCH and MCHN Multilayer High RF Power Capacitors

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

-Thermo-set plastic coated parts can withstand a minimum breakdown voltage of 1000 Vrms, uniformly applied across the 'C' dimension of the toroid.

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

CALL (512 ) x6400

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

HD25. Industrial Rugged Metal Optical Encoder Page 1 of 6. Description. Mechanical Drawing. Features

Nuclear Qualified Control Relays Series EGP/EML/ETR

SUPER MINIATURE PC BOARD TYPE AUTOMOTIVE RELAY

HIGH REPEATABILITY, TO-5 RELAYS DPDT

Fully Sealed Container Cermet Potentiometers Military and Professional Grade

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS

Micro-ISO Automotive Relay. (Unit: mm inch)

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations

MAGNETIC-LATCHING DC-8 GHz TO-5 RELAYS 4PST

50W TO220 High Power Resistors

Legacy Printed Circuit Board & Reed Relays. Catalog

( This link will provide you with a list of all ISO-6983 G-Codes

B3F. Miniature, Space-saving Switch

DC-DC Converter Module

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

-Thermo-set plastic coated parts can withstand a minimum breakdown voltage of 1000 Vrms, uniformly applied across the 'C' dimension of the toroid.

Electronics Review 2 Cornerstone Electronics Technology and Robotics II

HIGH CAPACITY, LONG LIFE SUBMINIATURE SWITCH

SLIM COMPACT SAFETY RELAY

PTS Series High Grade Slide Potentiometer

Series 291 Optical Encoder

discontinued October 31, 2017 or until inventory is

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

MCHXXX. Simple to install MECHANICAL. HANDLE STROKE ± 30 (60 total travel)

Electromechanical Printed Circuit Board Relays Application Data

Position switches FM series

Nuclear Qualified Control Relays Series EGP/EML/ETR

PLEDxUSW Series, Unidirectional, White DO-214AA

KRPA, KRP, KA, KR series

RPE Parallel Gripper- Electric Gripper Series

SPST-NO SPDT DPST-NO DPDT

AGASTAT GP/ML/TR Series, 10 Amp Control Relay, Non-latching, Latching & Timing Versions

3Specifications CHAPTER THREE IN THIS CHAPTER

Magnecraft Printed Circuit Board & Reed Relays. Catalog

MH Series, W. Input Ranges : 9-75 VDC

Variable Transformers Product Design & Engineering Data

For Reference Only DUAL-OUTPUT HALL-EFFECT SWITCH FEATURES. ABSOLUTE MAXIMUM RATINGS at T A = +25 C

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

Slim compact safety relay

CENTIGRID ESTABLISHED RELIABILITY RELAYS

Review 6. unlike poles cause the magnets to attract. like poles cause the magnets to repel.

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Table of Contents. Kilovac Time Delay Relays

Type KLF Generator Field Protection-Loss of Field Relay

-Thermo-set plastic coated parts can withstand a minimum breakdown voltage of 1000 Vrms, uniformly applied across the 'C' dimension of the toroid.

Spring Return DuraDrive Proportional Actuator

Doler Self Colleting Machines*

200A type has been added. High Capacity of Max. 1,000 V DC Cut-off Possible

TV-15, 30 AMP (1 Form A) Power Relay

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Sold & Serviced By: ELECTROMATE. Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099

Selecting the Best Inductor for Your DC-DC Converter Leonard Crane Coilcraft

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Types MC and MCN Multilayer RF Capacitors

From dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz).

LoopBack Relay. LB363 Series. With Built-in AC Bypass Capacitors. LoopBack Relay, Sensitive Coil, thru-hole with AC Bypass Capacitors

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

The EVI 30/8 coils can be equipped with the suitable plunger guide tube (see S8 - S9 Catalogue).

MAGNETIC-LATCHING DPDT HALF-SIZE CRYSTAL CAN HIGH POWER RF RELAY DC-3 GHZ

Transcription:

Ledex Low Profile Linear Solenoids 8. (55.9) 6. (66.9). (77.9). (89.) % Duty Cycle W 5% Duty Cycle 8W 5% Duty Cycle 6W % Duty Cycle W

Ledex Low Profile Solenoids Linear actuation Space-saving, low-profile configuration Ideal for high force, short stroke applications Forces to 9 lbs. Stroke lengths to.7 inches The low profile shape, besides contributing to smaller size, optimizes the magnetic flux paths for imum force versus stroke characteristics. The construction of the plunger assembly provides an auxiliary flux path which permits a significant increase in force. The low profile solenoid construction not only provides long life, but also provides a rugged design for both military and commercial applications. Flat Face: Higher efficiency for shorter strokes Conical Face vs. Flat Face Plunger Design Conical-faced designs extend the useful range of a solenoid to provide higher forces for strokes typically over.6 inches. The pole surface area is greater and the distance between the tapered cone faces is approximately one-half that of the gap between the land faces (for angles), providing the effect of a closer air gap. Conical Face: Higher force for longer strokes April, 6 are RoHS Compliant While some of the force component is lost because the force vector is not parallel with the plunger motion, the shorter gap and higher flux density combine to provide more output force for longer strokes. For shorter strokes, the magnetic flux density increases and causes the iron to saturate rapidly as the poles move closer, thus reducing the efficiency of the conical-faced design. At this point, the flat-faced plunger is more efficient. The main advantage of the flat-faced pole over the conical is that the full component of force is usable because the force vector is parallel with the pole motion. Applications The reliability and high performance of Low Profile solenoids make them an ideal choice for applications in which consistent, reliable operation is critical. Pumps Machine tools Packaging machines Cranes Instruments Flow controls Trucks and buses Computer peripherals De-Energized Energized De-Energized Energized Ledex Solenoids G

Ledex Low Profile Solenoids Why Low Profile solenoids provide such high force and rapid response. A key to the efficiency and compact form factor of the low profile solenoid is our special precision coil-winding process. With imum copper packed into the allowable space, each solenoid develops tremendous force for its size and power input. The low profile form, in addition to contributing to smaller size, permits imum pole face surface area for the magnetic flux. Another factor that contributes to high efficiency is the additional iron surface on the external portion of the plunger; it provides an auxiliary flux path and a significant increase in force. The force is also affected by other interrelated features, such as the length of the iron path, the magnetic saturation properties of the solenoid case and plunger, and the area and shape of the pole pieces. The enclosed construction of the solenoid not only provides an iron path with minimum losses at the ring gap, but also provides a rugged design for critical environment applications Curves The performance curves in this section serve as guides to determine the solenoid size needed to produce a desired force at a given stroke, duty cycle, and power source. All curves were developed under the following standard test conditions: ambient temperature of C, 65% relative humidity. Starting Force When determining an application s force requirement, apply a.5 safety factor. For example: a load requiring.5 lb of force should utilize a solenoid providing.5 x.5 or 6.75 lb of force. Duty Cycle Duty cycle is determined by: ON time/(on + OFF time). For example: a solenoid is actuated for seconds, then off for 9 seconds. sec ON / ( Sec ON + 9 sec OFF) = / = / or 5% duty cycle. Ledex Low Profile solenoids are rated for various duty cycles ranging from continuous to % duty. Note that imum ON time for a particular application can be a factor which overrides the duty cycle rating. For example, at 5% duty cycle, the imum ON time for a given Ledex solenoid is 6 seconds. If, however, the solenoid is operated at a cycle rate which enables the unit to return to ambient temperature between ON cycles, then the imum ON time is extended somewhat. In the above example, this extended ON time is seconds. Maximum ON time ratings are listed on the individual model specification pages. Typical Examples of Custom Features Even though many solenoid designs are in stock, our customers often require a product with unique features or performance capabilities. So, if you don t find what you re looking for in the catalog, give us a call to discuss your needs with one of our application engineers. Plunger Retainer (to limit stroke) Riveted retainer for armature end shaft extension Axial stroke Truarc retainer for base shaft extension Mounting Plate mounting Foot mounting Axial stroke Termination Glass bead terminals (base) Stranded leads (base) Stranded leads Solder terminals Life When selecting a Low Profile solenoid, as with any other solenoid style, it is important to consider factors that will affect the life of the unit. Heat, side-loading, stroke and operating environment all play an important role in determining the life you can expect in your application. A simple, yet often overlooked method to improve Low Profile solenoid life is to minimize the side load. Maximum life can be achieved by mounting Low Profile solenoids so that the shaft travels along a vertical plane. Keeping the stroke as short as possible will also improve life. Elliptical Flatted Drilled hole Threaded rod Power Take Off Clevis-grooved/cross hole Clevis-tongue Notched Tapped hole Power Requirements Voltage applied to the solenoid must be matched to the coil wire size for proper operation. Solenoids are cataloged in coil awgs ranging from # up to #8 to accommodate your input power. Refer to the individual model specification pages for coil wire awg recommendations. Many other coil awg sizes are available. Please feel free to contact our application engineering department for availability. Ledex Solenoids G

Ledex Low Profile Selection Low Profile solenoids are available in nine sizes. Use the selection chart to determine which size offers the desired performance and mechanical specifications. Refer to the individual size specification pages for complete performance and mechanical data. Well-suited for battery operation. See the "Battery Operated Solenoids" section for complete information. How to Use Low Profile Charts. Select one of the four columns which provides the appropriate duty cycle. (For example 5%.). Reading down this column provides a variety of performance and electrical data including imum on time, watts, and amp turns.. Following down the column further into the VDC ratings, select the voltage which most closely matches your supply voltage. (For example, 8.9 for a 9 VDC power supply.). Read across (to the left) to select the awg suffix to complete the part number when ordering. (In this example using our EC chart, awg is required, thus to order, specify: 75-. April, 6 are RoHS Compliant Low Profile Selection Overview Package Max Nominal Force (lbs) @ Nominal Stroke Dimensions Stroke Stroke at Specified Duty Cycle @ C Size* Dia. Length (in) (in) % 5% 5% % OEC.75.5.5.6.9..9.6 EC..5..8.5.5.5. EF.5.58.75...5 7..5 EC.5.58...5...75 EF..69.75..5 5... EC..69...8..8 5.6 EF.56.85..6. 6.5. 5. EC.56.85.5.5..5 5.5.5 5SF.875.88..8. 9.5 7. 9. 5EC.875.5...5 5... 6SF.5.5.8.8... 8. 6EC.5... 6.... 7EC.75.78.7. 9. 8.. 5. 8EC.75.65.7. 7. 5. 9. 5. All data is at C coil temperature. Force outputs degrade with elevated temperatures. * EC sizes have conical face plungers, EF and SF sizes have flat face plungers. Maximum Duty Cycle % 5% 5% % Maximum ON Time (sec) 6 7 when pulsed continuously Maximum ON Time (sec) 6 8 for single pulse Watts (@ C).5 9 8 5 Ampere Turns (@ C) 8.5 57 9 (XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom) 6.5 9.6.. 5. 7.97 6..8.9 6. 8. 5.6.7 5. 8. 9. 5.. 6. 9.9.9. 5.7 8..7 5.6 5. 7. 9.9 5.8 9.9 6. 8.9. 9.7.95 5 8.. 5.7 5..6 68.... 5 7. 8.8 8. 5.. 6 58.5 56 6... 5. 7 78.7 9 9.8 8. 9. 6. 8. 7 5. 5. 9. 78. Ledex Solenoids G

Ledex Low Profile Size EC Push or Pull Medium Stroke, Conical Face Part Number: 75-XX April, 6 are RoHS Compliant Maximum Duty Cycle % 5% 5% % Maximum ON Time (sec) 6 7 Maximum ON Time (sec) 6 8 for single pulse Watts (@ C).5 9 8 5 Ampere Turns (@ C) 85 57 9 (XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom) 6.5 9.6.. 5. 7.97 6..8.9 6. 8. 5.6.7 5. 8. 9. 5.. 6. 9.9.9. 5.7 8..7 5.6 5. 7. 9.9 5.8 9.9 6. 8.9. 9.7.95 5 8.. 5.7 5..6 68.... 5 7. 8.8 8. 5.. 6 58.5 56 6... 5. 7 78.7 9 9.8 8. 9. 6. 8. 7 5. 5. 9. 78. temperature C) Dielectric Strength VRMS flow of air at C, with solenoid aluminum plate measuring square by 8 Coil Resistance ±% tolerance on all coil awg sizes.875 oz (.8 gms) Holding Force.7 lb (7.6 N) @ 5 C Dimensions Ø.75" x.5" L (See page G6) Add the coil awg number (XX) to the part number (for example: to order a 5% duty cycle unit rated at. VDC, specify 75-6). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Well-suited for battery operation. See the "Battery Operated Solenoids" section for complete information. Size OEC Typical Force @ C Size OEC Typical Speed @ No Load, C 5. (.). (7.8). (.). (8.9). (.5) % Duty Cycle 5W 5% Duty Cycle 8W 5% Duty Cycle 9W % Duty Cycle.5W 6 8 % Duty Cycle.5W 5% Duty Cycle 9W 5% Duty Cycle 8W % Duty Cycle 5W. (.5). (.).6.8. (.5) (.) (.5). (.5). (.56). (.).8. (.) (.5).6 (.6). (5.8) Ledex Solenoids G5

Ledex Low Profile Size EC Push or Pull Size EC Medium Stroke, Conical Face Part Number: -XX April, 6 are RoHS Compliant Maximum Duty Cycle % 5% 5% % Maximum ON Time (sec) 6 7 Maximum ON Time (sec) 6 8 for single pulse Watts (@ C) 5 5 Ampere Turns (@ C) 8 68 75 (XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom) 5.8..9. 6.5 6.8 86.6.7 5. 8. 7.9..5 6.. 8.7 7. 5.7 8..8 9 5.7 5 5. 7.. 6. 8.5 6.5 9....95 55 8..6 6. 6..7 68.6.9...6 88.7 8. 6.. 5.95 78 6.5.. 5. 5 8.9 9... 67. 6. 5 6. 7. 5. 8. temperature C) Dielectric Strength VRMS flow of air at C, with solenoid aluminum plate measuring square by 8 Coil Resistance 5-5 awg, ±5%; 6 awg, ±%.5 oz (.5 gms) Holding Force 5. lb (. N) @ 5 C Dimensions Ø." x.5" L (See page G6) Add the coil awg number (XX) to the part number (for example: to order a 5% duty cycle unit rated at 6. VDC, specify 9-7). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Well-suited for battery operation. See the "Battery Operated Solenoids" section for complete information. Size EC Typical Force @ C. (.5) 8. (5.6) 6. (6.7). (7.8). (8.9) % Duty Cycle 5W 5% Duty Cycle W 5% Duty Cycle W % Duty Cycle 5W Size EC Typical Speed @ No Load, C 6 8 % Duty 5W 5% Duty W 5% Duty W % Duty 5W.5 (.7). (.5).5 (.8). (5.8).5 (6.5). (7.6).8 (.).6. (.6) (6.). (8.). (.6) Ledex Solenoids G6

Ledex Low Profile Size EF/EC Push or Pull Size EF Short Stroke, Flat Face Part Number: 9-XX Size EC Medium Stroke, Conical Face Part Number: -XX Maximum Duty Cycle % 5% 5% % Maximum ON Time (sec) 6 7 Maximum ON Time (sec) 6 8 for single pulse Watts (@ C) 7 8 7 Ampere Turns (@ C) 5 6 89 5 (XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom).68...5 7. 5.6 7.8. 5.7 9. 6.96.6 5. 7..5 7.6 96.5 6. 9.. 8 5. 78 5.7 8..5 8. 9 6.9 7. 9.9.9.. 5 8.8.5 7.7 8. 6.85 69. 5.6. 5. 8.5 858.9 9.8 8...75 6 7.5 5. 5. 56. temperature C) April, 6 are RoHS Compliant Dielectric Strength VRMS flow of air at C, with solenoid aluminum plate measuring 8 square by 8 Coil Resistance - awg, ±5%.5 oz (6.8 gms) Holding Force EF. lb (5. N) @ 5 C Holding Force EC 5.7 lb (5. N) @ 5 C Dimensions Ø.5" x.58" L (See page G6) Add the coil awg number (XX) to the part number (for example: to order a 5% duty cycle unit rated at 9. VDC, specify 9-7). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Size EF and EC Typical Speed @ No Load, C 6 8 % Duty 7W 5% Duty W 5% Duty 8W % Duty 7W Well-suited for battery operation. See the "Battery Operated Solenoids" section for complete information..8 (.).6. (.6) (6.). (8.). (.6) Size EF Typical Force @ C Size EC Typical Force @ C. (77.9). (.). (6.8) 6. (7.) 8. (5.6) % Duty Cycle 7W 5% Duty Cycle 8W 5% Duty Cycle W % Duty Cycle 7W. (.5) 8. (5.6) 6. (6.7). (7.8). (8.9) % Duty Cycle 7W 5% Duty Cycle 8W 5% Duty Cycle W % Duty Cycle 7W. (.5). (.5)...5 (.76) (.) (.7).6 (.5).7 (.78). (.).8 (.)..6. (.5) (.6) (5.8). (6.).8 (7.) Ledex Solenoids G7

Ledex Low Profile Size EF/EC Push or Pull Size EF Short Stroke, Flat Face Part Number: 9-XX Size EC Medium Stroke, Conical Face Part Number: -XX Maximum Duty Cycle % 5% 5% % Maximum ON Time (sec) 6 8 Maximum ON Time (sec) 6 9 for single pulse Watts (@ C) 9 8 6 9 Ampere Turns (@ C) 55 756 7 69 (XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom).7 5.6.7 5. 8..8 9..6 6.6. 5.97 5. 5.9 8.. 6.6 8 5. 7.5.6 6.8 7 5. 5 6.7 9... 8 8. 5 8..9 6.8 7. 9. 67..7.. 9. 78. 8.6 6...8 8 6.9.. 5. 6.97 5. 9.. 65. 75. 5 6. 7. 5. 8. temperature C) April, 6 are RoHS Compliant Dielectric Strength -7 awg, VRMS ; 8- awg, VRMS flow of air at C, with solenoid aluminum plate measuring 5 8 square by 8 Coil Resistance - awg, ±5%.75 oz (6. gms) Holding Force EF 6. lb (5.6 N) @ 5 C Holding Force EC. lb (5. N) @ 5 C Dimensions Ø." x.69" L (See page G6) Add the coil awg number (XX) to the part number (for example: to order a 5% duty cycle unit rated at. VDC, specify 9-7). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Size EF and EC Typical Speed @ No Load, C 6 8 % Duty 9W 5% Duty 8W 5% Duty 6W % Duty 9W.8 (.).6. (.6) (6.). (8.). (.6) Size EF Typical Force @ C. (77.9). (.). (6.8) 6. (7.) 8. (5.6) % Duty Cycle 9W 5% Duty Cycle 6W 5% Duty Cycle 8W % Duty Cycle 9W Size EC Typical Force @ C. (89.) 6. (7.). (5.) 8. (5.6). (7.8) % Duty Cycle 9W 5% Duty Cycle 6W 5% Duty Cycle 8W % Duty Cycle 9W.. (.5) (.5)...5 (.76) (.) (.7).6 (.5).7 (.78). (.).8 (.)..6. (.5) (.6) (5.8). (6.).8 (7.) Ledex Solenoids G8

Ledex Low Profile Size EF/EC Push or Pull Size EF Short Stroke, Flat Face Part Number: 9-XX Size EC Medium Stroke, Conical Face Part Number: 99-XX Maximum Duty Cycle % 5% 5% % Maximum ON Time (sec) 6 9 Maximum ON Time (sec) 6 for single pulse Watts (@ C).5 5 5 5 Ampere Turns (@ C) 7 5 5 (XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom).59 66. 6. 8.5.. 5. 7.. 6. 5.5 8 6.6 9... 6 5.67 86 8..7 6.6 6. 7 8.76 6..6.. 8.8 78. 8.5 6.. 9.6 975 6.6.. 5..8 9. 9.. 66. 56.7 5 7. 7. 5. 8. 88. 98. 6. 66.. 8. 6. 59. 8.. temperature C) April, 6 are RoHS Compliant Dielectric Strength - awg, VRMS ; 5- awg, VRMS flow of air at C, with solenoid aluminum plate measuring 6 square by 8 Coil Resistance - awg, ±5% 6. oz (7 gms) Holding Force EF 7. lb (6.6 N) @ 5 C Holding Force EC 6. lb (7. N) @ 5 C Dimensions Ø.56" x.85" L (See page G7) Add the coil awg number (XX) to the part number (for example: to order a 5% duty cycle unit rated at VDC, specify 9-7). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Size EF and EC Typical Speed @ No Load, C 6 8 % Duty.5W 5% Duty 5W 5% Duty 5W % Duty 5W Size EF Typical Force @ C Size EC Typical Force @ C 8. (56.) 6. (66.9). (78.). (89.) % Duty Cycle 5W 5% Duty Cycle 5W 5% Duty Cycle 5W % Duty Cycle.5W. (78.). (.5). (89.). (.5).8 (.).6. (.6) (6.). (8.). (.6) % Duty Cycle 5W 5% Duty Cycle 5W 5% Duty Cycle 5W % Duty Cycle.5W. (.5). (.).6.8. (.5) (.) (.5). (.5). (.56).5. (.7) (.5).5 (.8). (5.8).5 (6.5). (7.6) Ledex Solenoids G9

Ledex Low Profile Size 5SF Push or Pull Short Stroke, Flat Face Part Number: 95-XX April, 6 are RoHS Compliant Maximum Duty Cycle % 5% 5% % Maximum ON Time (sec) 6 Maximum ON Time (sec) 6 for single pulse Watts (@ C) 8 Ampere Turns (@ C) 86 7 7 (XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom). 88 6. 8.6. 9.. 6 7.6.8 5.. 5.9 9.6.6 9.. 6 7.7 55. 7.. 8. 7. 66 5... 8. 8 8.79 8 9. 7. 9. 6. 9.8 88.. 8. 77..86 75.. 6. 96. 7.9 596 8. 5. 76.. 9. 97 7. 67. 95. 5. 75. 96 6. 86.. 9. temperature C) Dielectric Strength awg, VRMS ; - awg, VRMS flow of air at C, with solenoid aluminum plate measuring 7 square by 8 Coil Resistance - awg, ±5% 9. oz (55 gms) Holding Force 58. lb (58. N) @ 5 C Dimensions Ø.875" x.88" L (See page G7) Add the coil awg number (XX) to the part number (for example: to order a 5% duty cycle unit rated at VDC, specify 95-7). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Size 5SF Typical Force @ C Size 5SF Typical Speed @ No Load, C. (.8) 8. (55.9) 6. (66.9). (77.9). (89.) % Duty W 5% Duty 8W 5% Duty W % Duty W 6 8 % Duty W 5% Duty W 5% Duty 8W % Duty W. (.5). (.).6.8. (.5) (.) (.5). (.5). (.56). (.).8. (.) (.5).6 (.6). (5.8) Ledex Solenoids G

Ledex Low Profile Size 5EC Push or Pull Medium Stroke, Conical Face Part Number: 95-XX April, 6 are RoHS Compliant Maximum Duty Cycle % 5% 5% % Maximum ON Time (sec) 6 Maximum ON Time (sec) 6 for single pulse Watts (@ C) 8 Ampere Turns (@ C) 5 (XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom).7 8 7..... 86 9..7 8. 8. 5 6.66 59.5 6.. 6. 6. 77.. 8.. 7 5.7 9 7.7 5. 5. 56. 8 6.6 9.. 5. 7. 9 8. 8 8.. 56. 89. 6. 768 6. 5. 7.. 96. 66 5. 6. 9.. 57. 86 57. 8.. 79.. 7... 6. temperature C) Dielectric Strength awg, VRMS ; - awg, VRMS flow of air at C, with solenoid aluminum plate measuring 7 square by 8 Coil Resistance - awg, ±5%.5 oz (6. gms) Holding Force 7. lb (. N) @ 5 C Dimensions Ø.875" x.5" L (See page G7) Add the coil awg number (XX) to the part number (for example: to order a 5% duty cycle unit rated at 5 VDC, specify 95-7). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Size 5EC Typical Force @ C. (77.9). (.). (6.8) 6. (7.) 8. (5.6) % Duty W 5% Duty 8W 5% Duty W % Duty W Size 5EC Typical Speed @ No Load, C 6 8 % Duty W 5% Duty W 5% Duty 8W % Duty W. (.5). (5.8). (7.6). (.6).5 (.7).6 (5.). (.5).. (5.8) (7.6). (.6).5 (.7) Ledex Solenoids G

Ledex Low Profile Size 6SF Push or Pull Short Stroke, Flat Face Part Number: 87789-XX April, 6 are RoHS Compliant Maximum Duty Cycle % 5% 5% % Maximum ON Time (sec) 87 6 Maximum ON Time (sec) 6 for single pulse Watts (@ C) 6 8 Ampere Turns (@ C) 76 9 9 (XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom).59..6.. 5. 5. 8. 6.. 5 9.5 78 6.7.. 5. 6. 858... 66. 7.69 7. 8. 5. 8. 8 8.7. 8. 68. 6. 9 5.6 68. 59. 8.. 9.67 8 5. 76. 7. 68.. 65 67. 95.... 8 8. 8. 67. 6. 8. 5. 9... temperature C) Dielectric Strength - awg, VRMS ; - awg, 5 VRMS flow of air at C, with solenoid aluminum plate measuring 8 square by 8 Coil Resistance - awg, ±5% lb oz (5. gms) Holding Force 88. lb (9. N) @ 5 C Dimensions Ø.5" x.5" L (See page G8) Add the coil awg number (XX) to the part number (for example: to order a 5% duty cycle unit rated at 5 VDC, specify 87789-7). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Size 6SF Typical Force @ C Size 6SF Typical Speed @ No Load, C 8 (67.5) % Duty Cycle W 5% Duty Cycle 8W 5% Duty Cycle 6W % Duty Cycle W 6 (7.7) 8 (55.9) 6 % Duty W 5% Duty 6W 5% Duty 8W % Duty W. (.).8. (.) (.5).6 (.6). (5.8).. (.5) (5.8). (7.6). (.6) Ledex Solenoids G

Ledex Low Profile Size 6EC Push or Pull Medium Stroke, Conical Face Part Number: 79-XX April, 6 are RoHS Compliant Maximum Duty Cycle % 5% 5% % Maximum ON Time (sec) 87 6 Maximum ON Time (sec) 6 for single pulse Watts (@ C) 6 8 Ampere Turns (@ C) 8 8 9 6 (XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom).69 567. 7.. 8. 7. 7 5.5.. 8. 5.9 96 9.9 8. 9. 6. 6 9.7 7 5. 5. 9. 78. 7. 5.. 6. 99. 8 5.6 9. 56. 79. 5. 9 7. 9. 69. 98. 5. 6. 9 6. 89. 6. 98. 95. 6 8.. 59. 5. 88. 5 98. 8. 95. 6. 7. 5 6. 77. 5. 9. temperature C) Dielectric Strength - awg, VRMS ; - awg, 5 VRMS flow of air at C, with solenoid aluminum plate measuring 8 square by 8 Coil Resistance - awg, ±5% lb 5.5 oz (69.5 gms) Holding Force 9. lb (8. N) @ 5 C Dimensions Ø.5" x." L (See page G8) Add the coil awg number (XX) to the part number (for example: to order a 5% duty cycle unit rated at 6 VDC, specify 79-7). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Size 6EC Typical Force at C. (.8) 8. (55.9) 6. (66.9). (77.9). (89.) % Duty Cycle W 5% Duty Cycle 8W 5% Duty Cycle 6W % Duty Cycle W Size 6EC Typical Speed @ No Load, C 6 8 % Duty W 5% Duty 6W 5% Duty 8W % Duty W. (.5). (5.8). (7.6). (.6).5 (.7).6 (5.).8 (.).6. (.6) (6.). (8.). (.6) Ledex Solenoids G

Ledex Low Profile Size 7EC Push or Pull Medium Stroke, Conical Face Part Number: 957-XX April, 6 are RoHS Compliant Maximum Duty Cycle % 5% 5% % Maximum ON Time (sec) 8 8 6 Maximum ON Time (sec) 8 5 8 for single pulse Watts (@ C) 5 7 5 Ampere Turns (@ C) 85 555 6 57 (XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom).8 9. 7. 9. 6. 6.5 7.. 8. 76. 5 7. 65.. 6. 97. 6.8 9 9. 55. 78.. 7 68. 6 9. 69. 98. 55. 8 8. 55 6. 87.. 9. 9 6. 9 75. 6. 5. 8. 65. 5 96. 6. 9. 5. 85. 58 6. 6.. 67. 58. 7.. 86. 5. 88. 8 76. 8. 5. 6. temperature C) Dielectric Strength -9 awg, VRMS ; - awg, 5 VRMS flow of air at C, with solenoid aluminum plate measuring 5 8 square by 8 Coil Resistance - awg, ±5%; - awg, ±%.5 lb (. kg) Holding Force 5. lb (. N) @ 5 C Dimensions Ø.75" x.78" L (See page G8) Add the coil awg number (XX) to the part number (for example: to order a 5% duty cycle unit rated at 8 VDC, specify 957-). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Size 7EC Typical Force @ C. (.8) 8. (55.9) 6. (66.9). (77.9). (89.) % Duty Cycle 5W 5% Duty Cycle W 5% Duty Cycle 7W % Duty Cycle 5W Size 7EC Typical Speed @ No Load, C 8 6 % Duty 5W 5% Duty 7W 5% Duty W % Duty 5W. (.5). (5.8).. (7.6) (.6).5 (.7).6 (5.).7 (7.78). (5.8)..6 (.6) (5.).8 (.). (5.) Ledex Solenoids G

Ledex Low Profile Size 8EC Push or Pull Medium Stroke, Conical Face Part Number: 96-XX April, 6 are RoHS Compliant Maximum Duty Cycle % 5% 5% % Maximum ON Time (sec) 7 Maximum ON Time (sec) 56 for single pulse Watts (@ C) 8 6 Ampere Turns (@ C) 95 5 55 695 (XX) (@ C) Turns (Nom) (Nom) (Nom) (Nom) 9. 5 8.. 56. 88.. 95 6. 5. 7.. 5 9. 8 5. 6. 9.. 6 78. 6 57. 8.. 79. 7 9. 7 7. 99... 8 8. 58 87.. 7. 75. 9. 596. 57.. 5. 5. 675. 87. 6. 7. 68. 875 67. 7. 5. 59.... 7. 59. 5 9. 5. 98. temperature C) Dielectric Strength -7 awg, VRMS ; 8- awg, 5 VRMS flow of air at C, with solenoid aluminum plate measuring square by 8 Coil Resistance - awg, ±5%; - awg, ±%.9 lb (. kg) Holding Force. lb (5.7 N) @ 5 C Dimensions Ø.75" x.65" L (See page G8) Add the coil awg number (XX) to the part number (for example: to order a 5% duty cycle unit rated at 9 VDC, specify 96-5). Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors. Size 8EC Typical Force at C. (889.5) 6. (7.6). (5.7) 8. (55.9). (77.9) % Duty Cycle W 5% Duty Cycle 6W 5% Duty Cycle 8W % Duty Cycle W Size 8EC Typical Speed @ No Load, C 8 6 % Duty W 5% Duty 8W 5% Duty 6W % Duty W. (.5 ). (5.8).. (7.6) (.6).5 (.7).6 (5.).7 (7.78). (5.8)..6 (.6) (5.).8 (.). (5.) Ledex Solenoids G5

Ledex Low Profile Dimensions Inches (mm) All solenoids are illustrated in energized state Size OEC Size EC.5 (.7).5 + -.5 (6.5 + -.8).5 (.6).5 + -.5 (6.5 + -.8).5 + -. (.75 + -.5).5 (6.5).75 +./-. (9.5 +.787/-.5).56 + -. (.96 + -.5). (8.8). + -. (5. + -.58).5 (.7).656 (6.66).75 + -.5 (9.55 + -.8) #-56 NC-A thd.5 + -.5 (.7 + -.8) #-8 NC-A thd Leads " min AWG Teflon.86 + -.5 (.8 + -.8).75 + -. (9.55 + -.5) Leads " min AWG PVC.6 + -.5 (5.86 + -.8).7 + -. (. + -.5) Size EF/EC. + -. (.58 + -.5) (EF Only).56 + -. (.96 + -.5).58 (.7).5 + -.5 (6.5 + -.8).6 (9.).5 +./-. (8.575 +.787/-.5) Size EF/EC.8 + -.7 (.7 + -.78) (EF Only).87 + -. (.75 + -.5).69 (7.5).7 + -.5 (. + -.8). (.8). +./-. (.5 +.787/-.5).78 (8.7).875 (.5).5 + -.5 (.7 + -.8) #-8 NC-A thd.5 + -.5 (.7 + -.8) #5- NC A thd Leads " min AWG PVC.6 + -.5 (7. + -.8).7 + -. (. + -.5) Leads " min AWG PVC.7 + -.5 (9.7 + -.8).65 + -. (5.875 + -.5) Solenoid Shown Energized Ledex Solenoids G6

Ledex Low Profile Dimensions Inches (mm) All solenoids are illustrated in energized state Size EF/EC. + -. (.86 + -.5) (EF Only).85 (.9).5 + -.5 (.7 + -.8).8 + -. (5.57 + -.5).5 (.6).56 +./-. (9.675 +.787/-.5).6 (6.975).5 + -.5 (.7 + -.8) #6- NC-A thd Leads " min AWG PVC. + -.5 (.579 + -.8).75 (9.5) Size 5SF.6 + -. (.9 + -.5).5 + -. (6.5 + -.5).88 (.5).5 + -.5 (.7 + -.8).65 + -. (5.875 + -.5).5 (.75).875 +./-. (7.65 +.787/-.5) Size 5EC.5 + -. (6.5 + -.5).5 (6.9).5 + -.5 (.7 + -.8).65 + -. (5.875 + -.5).5 (.75).875 +./-. (7.65 +.787/-.5).5 + -.5 (.7 + -.8) #8- NC-A thd.5 + -.5 (.7 + -.8) #8- NC-A thd Leads " min AWG PVC.6 + -.5 (.6 + -.8).75 (9.5) Leads " min AWG PVC.5 + -.5 (8.68 + -.8).75 (9.5) Ledex Solenoids G7

Ledex Low Profile Dimensions Inches (mm) All solenoids are illustrated in energized state Size 6SF Size 6EC.6 + -. (.9 + -.5).5 (9.8).65 + -.5 (5.875 + -.8). (.78).65 + -.5 (5.875 + -.8). + -. (7.95 + -.5).7 (8.9).5 +./-. (57.5 +.787/-.5). + -. (7.95 + -.5).7 (8.9).5 +./-. (57.5 +.787/-.5).7 (6.5).7 (6.5).65 + -.5 (5.875 + -.8) #- NF-A thd.65 + -.5 (5.875 + -.8) #- NF-A thd Leads " min AWG PVC.755 + -.5 (.577 + -.8).75 (9.5) Leads " min AWG PVC.99 + -.5 (9.5 + -.8).875 + -. (.5 + -.5) Size 7EC.75 + -. (9.55 + -.5).75 (.5).75 + -.5 (9.5 + -.8).875 + -. (.5 + -.5).75 +./-. (69.85 +.5/-.58) Size 8EC.7 + -. (. + -.5).65 + -.5 (5.99 + -.8).75 + -.5 (9.5 + -.8).6 + -. (6.975 + -.5).75 +./-. (85.75 +.787/-.5).75 (.5).5 (5.975).75 + -.5 (9.5 + -.8).5-8 NF-A thd.855 + -.5 (.77 + -.8).5-8 NF-A thd Leads " min. awg.5 + -.5 (6.5 + -.8).875 (.5) Leads " min. awg PVC. + -.5 (76.78 + -.8).875 (.5) Ledex Solenoids G8