Electrical Description

Similar documents
DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

VI 3 - i TABLE OF CONTENTS

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

K Factor Power Transformers

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

Low Voltage Products. Third Harmonic Filter THF and THF star System components for assembly and retrofitting. Catalogue THFS2GB 03_05 1SCC330004C0201

Embedded Generation Connection Application Form

I -limiter The world s fastest switching device

Impact Assessment Generator Form

Residual Current Operated Circuit-Breakers (RCCBs)

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

Series P. Applications

Test description for dry-type transformers chapter for type tests

Embedded Generation Connection Application Form

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

TECHNICAL DATA TYPE SHZV VACUUM ON-LOAD TAP CHANGER FOR OIL-IMMERSED TRANSFORMER

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

Company Directive STANDARD TECHNIQUE: SD7F/2. Determination of Short Circuit Duty for Switchgear on the WPD Distribution System

ON LOAD TAP CHANGERS RSV 5.3 TECHNICAL DATA

ON LOAD TAP CHANGERS RS 6.3 / RS 6 TECHNICAL DATA

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

CP CU1. Coupling unit for line and ground testing

Test description for dry-type transformers chapter for special tests

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

TECHNICAL DATA TYPE CMD OIL-IMMERSED ON-LOAD TAP CHANGER

PUBLIC POWER CORPORATION ENGINEERING & CONSTRUCTION OF TRANSMISSION PROJECTS DEPARTMENT

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Introduction. Centrado leading-edge transformer. Introduction

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

7. INSPECTION AND TEST PROCEDURES

Need for grounding Codes and Standards for grounding Wind Turbine Generator grounding design Foundation + Horizontal Electrode grounding design

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

1% Switchgear and Substations

DEIF A/S. Insulation monitor. Type SIM-Q

Insulation Co-ordination For HVDC Station

On-Load Tap Changer Type M

Course No: 1 13 (3 Days) FAULT CURRENT CALCULATION & RELAY SETTING & RELAY CO-ORDINATION. Course Content

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Figure 1. Two- and Three-phase MagneX Interrupter.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

Transformer Trainer. Electrical Power Systems PSL20. Learning Outcomes. Key Features. Key Specifications

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Single Line Diagram of Substations

Cast resin transformers HARMONY TM

Functional data Factory settings Variable Settings

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Automatic Transformer Winding Analyser

Substation Preventive Maintenance

Technical features table for miniature circuit-breakers SH 200 Series

Protection of Electrical Networks. Christophe Prévé

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Connection Impact Assessment Application

Problems connected with Commissioning of Power Transformers

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

Embedded Generation Connection Application Form

1ZSC AAJ en, Rev. 1. Vacuum on-load tap-changers, type VUBB Technical guide

Transformer Factory Testing

Earth fault protection for isolated neutral systems with frequency converters

Electrical IP Red Seal Practice Exam

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

PRODUCT / TEST MANUAL 2V162K4 VOLTAGE REGULATOR RELAY

V P N. Voltage transducer DVM 4200 = 4200 V

V P N. Voltage transducer DVM 2000-B = 2000 V

Case Study 1. Power System Planning and Design: Power Plant, Transmission Lines, and Substations

Technical Data Sheets

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

presentation contents application advantages

POWER SYSTEM ANALYSIS TADP 641 SETTING OF OVERCURRENT RELAYS

Tesar s.r.l. Installation and maintenance manual. Installation, use and maintenance. Manual. Page :1\20

Basic Principles and Operation of Transformer

Installation requirements

LED Driver Constant voltage

Methods of secondary short circuit current control in single phase transformers

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

Transcription:

History of this Document Rev. no.: Date: Description of change 0 First edition 2 2003-10-08 Section 3: The rated power of the transformer can be increased by 40% if they are equipped with 6 fans for forced cooling (AF - Air Forced) has been deleted. Section 6: Neutral earth changed to earth. 180 replaced by 180º. Section 9 updated. 3 2003-11-26 Section 9: AGO added. 4 2005-06-02 Medium Voltage replaced with High Voltage Nameplates for V80-1.8MW and V90-2.0MW added in section 7 Page 4: In section title, 50Hz removed Page 5: In section title, 50Hz removed Page 6: In section title, 50Hz removed Added name plates: V66-1.75MW / 60 Hz V66-2.0MW / 60 Hz V80-2.0MW / 60 Hz V80-2.0MW / 50 Hz V90-1.8MW / 60 Hz V90-2.0MW / 60 Hz Page: 1 of 17

Contents...Page 1. High Voltage Grid Connection... 3 2. Transformer...3 3. Transformer Data... 3 4. High Voltage-Circuit Breaker... 7 5. Earthing... 7 6. The Earthing System of the Wind Turbine/Lightning Protection... 7 7. Nameplate on the Nacelle Controller... 9 8. Short Curcuit Protection of the Nacelle Controller... 14 9. Monitoring of the Grid... 14 10. Component Prefix... 15 11. Component Numbers... 16 12. Assembly and Terminal Designation... 17 Page: 2 of 17

1. High Voltage Grid Connection The turbine can be connected to the grid in the range from 6 kv to 33 kv, where 36 kv (Um) is the highest equipment voltage. The high voltage grid cables are led through a 200 mm tube in the foundation to the high voltage circuit breaker which is placed at the bottom of the tower. The voltage of the high-voltage grid shall be within +5 / -5 %. Steady variations within +1 / -3 Hz are acceptable. Intermitted or rapid fluctuations off the grid s frequency may cause serious damage to the turbine. Grid dropouts must only take place once a week as an average over the lifetime of the turbine. 2. Transformer The transformer is located in the nacelle. The winding is delta connected on the HV-side unless anything else is specified. The winding is connected in star on the LV-side (690V). The 690V system in the nacelle is a TN-system, which means that the star point is connected to earth. The transformer is a three-phase dry type transformer, which is self-extinguishing. 3. Transformer Data Three phased transformers for indoor use. Fittings: 2 pcs. PT100 sensors per phase Design, manufacturing, routine tests and tolerances according to IEC 76 and IEC 726 standards. Page: 3 of 17

Transformer 10.5 kv. Rated power 690V: S r = 1902 kva (AF - Air Forced) Rated power 480V: S r = 205 kva (AF - Air Forced) f = 50 or 60 Hz Primary voltage: U = 10500 V Secondary voltage: U s = 690/480 V No load losses: P 0 3900 W Impedance losses at rated load (75 C): P Cu(75 C) 14400 W Impedance losses at rated load (120 C): P Cu(120 C) 16500 W Impedance voltage 690V, 1902kVA: e k 7 % Short circuit current 690V, 1902kVA: I max,3p 23 ka Short circuit current 480V, 205kVA: I max,3p 36 ka Full load current at 10,5 kv: I 10,5kV = 110/115 A (Cosϕ=1/0,96) Tap changer: n tp = ±2x2,5 % Highest equipment voltage: U m = 12 kv Power frequency voltage (50 Hz,1 min.) : U d = 28 kv (RMS) Lightning impulse voltage BIL (1,2/50 µs) : U p = 75 kv LV clearance voltage: = 1,1 kv LV test voltage (50 Hz, 1 min.) : = 3 kv Connection: = Dyn5 or Dyn11 Weight: < 5500 kg Max. ambient temperature: = 50 C Max. daily average temperature: = 40 C Max. yearly average temperature: = 30 C Max. temperature rise (hotspot): T (Pt100) = 95 K Reduction of generator power (hotspot): T (Pt100) = 145 C Cut out of generator (hotspot): T (Pt100) = 150 C Cut out of HV-grid (hotspot) : T (Pt100) = 155 C Temperature class: = F Environment class : = E2 Climate class: = C2 Fire behavior class: = F1 Page: 4 of 17

Transformer 20 kv. Rated power 690V: S r = 1902 kva (AF - Air Forced) Rated power 480V: S r = 205 kva (AF - Air Forced) f = 50 or 60 Hz Primary voltage: U = 20000 V Secondary voltage: U s = 690/480 V No load losses: P 0 3900 W Impedance losses at rated load (75 C): P Cu(75 C) 14400 W Impedance losses at rated load (120 C): P Cu(120 C) 16500 W Impedance voltage 690V, 1902kVA: e k 7 % Short circuit current 690V, 1902kVA: I max,3p 23 ka Short circuit current 480V, 205kVA: I max,3p 36 ka Full load current at 20 kv: I 20kV = 58/60 A (Cosϕ=1/0,96) Tap changer: n tp = ±2x2,5 % Highest equipment voltage: U m = 24 kv Power frequency voltage (50 Hz,1 min.) : U d = 50 kv (RMS) Lightning impulse voltage BIL (1,2/50 µs) : U p = 125 kv LV clearance voltage: = 1,1 kv LV test voltage (50 Hz, 1 min.) : = 3 kv Connection: = Dyn5 or Dyn11 Weight: < 5500 kg Max. ambient temperature: = 50 C Max. daily average temperature: = 40 C Max. yearly average temperature: = 30 C Max. temperature rise (hotspot): T (Pt100) = 95 K Reduction of generatorpower (hotspot): T (Pt100) = 145 C Cut out of generator (hotspot) : T (Pt100) = 150 C Cut out of HV-grid (hotspot) : T (Pt100) = 155 C Temperature class: = F Environment class : = E2 Climate class: = C2 Fire behavior class: = F1 Page: 5 of 17

Transformer 33 kv. Rated power 690V: S r = 1902 kva (AF - Air Forced) Rated power 480V: S r = 205 kva (AF - Air Forced) f = 50 or 60 Hz Primary voltage: U = 33000 V Secondary voltage: U s = 690/480 V No load losses: P 0 3900 W Impedance losses at rated load (75 C): P Cu(75 C) 14400 W Impedance losses at rated load (120 C): P Cu(120 C) 16500 W Impedance voltage 690V, 1902kVA: e k 7 % Short circuit current 690V, 1902kVA: I max,3p 23 ka Short circuit current 480V, 205kVA: I max,3p 36 ka Full load current at 33 kv: I 33kV = 35/36 A (Cosϕ=1/0,96) Tap changer: n tp = ±2x2,5 % Highest equipment voltage: U m = 36 kv Power frequency voltage (50 Hz,1 min.) : U d = 70 kv (RMS) Lightning impulse voltage BIL (1,2/50 µs) : U p = 170 kv LV clearance voltage: = 1,1 kv LV test voltage (50 Hz, 1 min.) : = 3 kv Connection: = Dyn5 or Dyn11 Weight: < 5500 kg Max. ambient temperature: = 50 C Max. daily average temperature: = 40 C Max. yearly average temperature: = 30 C Max. temperature rise (hotspot): T (Pt100) = 95 K Reduction of generatorpower (hotspot): T (Pt100) = 145 C Cut out of generator (hotspot): T (Pt100) = 150 C Cut out of HV-grid (hotspot) : T (Pt100) = 155 C Temperature class: = F Environment class : = E2 Climate class: = C2 Fire behavior class: = F1 Page: 6 of 17

4. High Voltage-Circuit Breaker Selection of high voltage-circuit breaker depends on the short circuit level. 1) Circuit breaker. A circuit breaker is able to protect the transformer cable (3x25+25 mm 2 ) up to 11 ka. 2) Fuses. Fuses protect the cable if high short circuit currents occur. However, there might be problems with the selectivity to short circuit protection of the high voltage-grid. 3) Circuit breaker and fuses. Fuses protect the cable at high short circuit currents, and it is possible to get the selectivity to short circuit protection of the high voltage-grid. The high voltage-circuit breaker must be equipped with a trip coil (230 V) which can be activated by the VMP-controller and manually from the nacelle. If the high voltage-circuit breaker is selected as a ring main unit, it is possible to loop further on to e.g. other turbines. 5. Earthing It has to be possible to make an earthing on the grid side and on the turbine side. It is possible to make an earthing in the nacelle. Equipment for the earthing in the nacelle is not supplied from Vestas. 6. The Earthing System of the Wind Turbine/Lightning Protection The system should be made at the same time as the foundation work. The earthing system must be accommodated to local soil conditions. The resistance to earth must be according to the requirements of the local authorities, but no more than 10 Ω. The earthing system must be made as a closed ring conductor with earthing rods providing the following advantages: 1. Personnel safety. The ring conductor limits step and contact voltage for persons, staying near the tower foundation in case of a lightning stroke. Page: 7 of 17

2. Operational safety. The earthing rods ensure a steady and low resistance to earth for the whole earthing system. The earthing system is made as follows: 1. Ring conductor in 50 mm 2 Cu is established at a distance of 1 m from the foundation and approx. 1 m below ground level. 2. The ring conductor is equipped with 2 copper coated earthing rods, each of 6 m (Ø14). The earthing rods are rammed down on each side of the tower (180º between the earthing rods). 3. The ring conductor is connected to two opposite points on the tubular tower. The nacelle controller is connected to one of these points. If the resistance to earth is not sufficiently low, the earthing system can be improved. 1. The two earthing rods can be extended to 10 m. Two extra earthing rods each of a length of 10 m can be added (90º between the 4 earthing rods). Page: 8 of 17

7. Nameplate on the Nacelle Controller 1,75 MW V66-1.75MW 50 Hz +1/-3 Hz 1418A 213A V66-1.75MW 60 Hz +2/-3 Hz 1418A 213A Page: 9 of 17

1.8MW V90-1.8MW 50 Hz +2/-3 Hz 1378A 220A V90-1.8MW 60 Hz +2/-3 Hz 1378A 220A Page: 10 of 17

2.0MW V66-2.0MW 50 Hz +1/-3 Hz 1600A 240A V66-2.0MW 60 Hz +2/-3 Hz 1600A 240A Page: 11 of 17

V80-2.0MW 60 Hz +2/-3 Hz 1600A 240A V80-2.0MW 50 Hz +1/-3 Hz 1600A 240A Page: 12 of 17

V90-2.0MW 50 Hz +1/-3 Hz 1600A 240A V90-2.0MW 60 Hz +1/-3 Hz 1600A 240A Page: 13 of 17

8. Short Curcuit Protection of the Nacelle Controller Breakers 690V Generator / Q8 ABB S7H 1600 Controller / Q15 ABB S3X VCS / Q7 ABB S5H 400 Breaking capacity, I cu, I cs 23 ka 75 ka 40 ka Making capacity, I cm 52 ka 440 ka 40 ka Thermo release, I th 1600A 100 A 400 A Magnetic release, I m 9.6 ka 1.0 ka 1600 A 9. Monitoring of the Grid The generator will be disconnected if the voltage or the frequency exceeds the following limits (measured at the 690 V side): Nominal phase voltage: U P,nom = 400 V. Phase voltage: U P Grid voltage: U N The generator and the converter will be disconnected if: The voltage is 10 % above the nominal voltage for 60 s. The voltage is 10 % below the nominal voltage for 60 s. The voltage is 13.5 % above the nominal voltage for 0.2 s. The frequency is above 51 Hz for 0.2 s. The frequency is below 47 Hz for 0.2 s. U P U N 440 V 762 V 360 V 624 V 454 V 786 V If a fault on the grid interrupts and the voltage supply to the VMP-controller, the emergency stop circuit will be opened immediately, and the generator will be disconnected simultaneously. In case the turbine has an Advanced Grid Option (AGO) the control system is supplied from an UPS system and the generator is kept connected until the voltage tolerance curve for the specific AGO solution is exceeded. Page: 14 of 17

10. Component Prefix This chapter explains the rules for stating the name of the components used in the controller. Components, in- and output are named with the following letter prefix: Prefix A B D E F G H K L M Q R S T U V W X Y Subject Group of components, e.g. top and ground controller Electronical signal ground controller, e.g. windvane, thermostat, sensor Auxiliary Relay Heating element/fan Thermo relay/circuit breaker/fuse Generator Signal lamp Contactor, relay Coil, discharge coil Motor Circuit breaker for main current circuit Resistance (temperature sensors) Switch function Transformer Rectifier Thyristor Cable Terminal Magnetic valve Page: 15 of 17

11. Component Numbers Components, in- and output are named with the following number: Component number Number group 0.. 99 100..199 200..299 300..399 400..499 500..599 600..699 700..799 800..899 900..999 Electric installation Yaw System Hydraulic System Ambient Transmission System/VOG Generator/VCS Control System/VCS Control System Control System - Hub Emergency Stop In- and output have the same number, if these have connection with the same component (e.g. control signal and feedback from contactor). The distinction is made by means of the signal's letter prefix. Two components with a complete parallel function have the same number, but they can be distinguished by means of a subsequent letter (E.g.: K100A, K100B). The auxiliary relays are defined as a component, which exclusively functions as a connecting link between e.g. a computer output and a contactor coil. The auxiliary relays have the letter prefix D and the same number as the component, which they serve. Page: 16 of 17

12. Assembly and Terminal Designation VMP-1,75/2,0MW controller include the following assemblys: A1 : Busbar section. A2 : Hub controller. A3 : VCS section. A4 : Control section.. A5 : Ground controller. A6A : Box for ultrasonic sensor. A6B : Box for ultrasonic sensor. A7 : Box on rotating transformer. A8 : Box on gear (sensors). A9 : Box for sensors at the main shaft. A10 : Box on generator. A11 : Box for sensors for the yaw system. A14 : Box for heating elements on the gear box. A15 : Box for transformer ventilation (trafo wall). A16 : Box for termistor on transformer vent. motors. A18 : Box for LT Heating systems in systems A32 : Box for Hydraulic systems A33 : Box on sliprings champer generator A34 : Box on sliprings champer Gear A35 : Box on offline filter gear Example of designation of terminals: Nacelle controller (A1), terminal block X4, terminal 8: A1.X4:8 Hub controller (A2), terminal block X1, terminal 4: A2.X1:4 Component K44, terminal 3: K44:3 Component K903, terminal 5: K903:5 Page: 17 of 17