Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252

Similar documents
Temperature sensor with integrated transmitter for maritime applications, MBT 5560

Heavy duty pressure controls Type MBC 5000 and MBC 5100

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Screw-in resistance thermometers with plug connector

Relative pressure transmitter type 522 for shipbuilding

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Electronic Pressure Switch Type MEP

Resistance thermometers for process technology

Resistance thermometer Model TR30, compact design

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Coriolis Massflowmeter

Tank contents transmitter

ED701 General Industry Pressure Transmitter

Miniature resistance thermometer Model TR33, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Coriolis Massflowmeter

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

CombiTemp TCR6 Standard RTD temperature sensor

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

INDUSTRIAL PRESSURE TRANSMITTER

Temperature Measurement Transmitter for field mounting/field indicator

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.)

Mineral-insulated resistance thermometers to EN

Our transformers are approved by classification societies given below: Lloyd s Register. Registro Italiano Navale. American Bureau of Shipping

TMU. Coriolis Mass Flow Meter. for liquids and gas

Coriolis Mass Flow Meter Model TM

ECT Applications. Features

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Low Pressure NSL Applications. Features

Industrial Pressure Transmitter

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Rudder or propeller angular position transmitter KINAX WT720

Resistance thermometer Model TR30, compact design

DATASHEET AIR / FLUE GAS TEMPERATURE SENSOR. TSD2-Series

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

TECHNICAL BULLETIN [ 1 / 10 ]

Level Switch Catalogue

Electronic Temperature Transmitters

KINAX WT 707 Transmitter for angular position

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

Resistance Thermometers Model Series TR7X0, Sheathed Design

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

NAT Applications. Features

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

LEVEL SWITCH CATALOGUE

Screw-in resistance thermometers with terminal head Form B

SATRON VB Pressure Transmitter

Your Global Automation Partner. PT2000 Pressure Transmitter

NAT Applications. Features

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

ph or ORP Transmitter

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

SMB Connectors. Adaptors-50Ω. Plug to Plug. Jack to Jack. Plug to Jack. Bulkhead Jack to Jack

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Directional valves Electrically operated Series 563, 565, 567. Brochure

IPC 704. Signal conditioner FEATURES. For CA piezoelectric accelerometers and CP dynamic pressure transducers

Resistance thermometer Model TR30, compact design

NEW. Automation Technology 768 series

Electrical Temperature Measurement

242, , FAX.

SERIESN50, COAXIAL CONNECTORS

TEMPERATURE SWITCHES AND SENSORS BIMETAL TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SENSORS SCREW-IN RESISTORS

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

SALES SERVICE +358 (0)

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Page Type Resolution (mm) min. max. Output

Resistance thermometer Model TR31, miniature design

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Digital conductivity transmitter

Coriolis Massflowmeter

Digital flow ELEMENT transmitter for continuous flow measurement

Rotary Measurement Technology Incremental Encoders

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Data Sheet for Angle Sensors

FLOAT LEVEL SENSOR TFC. Applications. Reference. Features

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

SRS SEALED ROTARY SENSORS

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Valves with a difference. Electrical Actuators DVC INTERNATIONAL

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Special Documentation Levelflex FMP51, FMP52, FMP55, FMP57

4.00 ULTRASONIC ANALYZER

Flow Measurement SITRANS F M

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Installation guide 971 SmartRadar LTi

INSERTION paddle wheel flowmeter for continuous flow measurement

Electromechanical pressure and vacuum switches 0

Electrodynamic Velocity Sensor

Valve Island with Electronic I/O

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Transcription:

Data sheet Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252 MBT 5250 MBT 5260 MBT 5252 Heavy-duty temperature sensors for controlling cooling water, lubrication oil, hydraulic oil and refrigeration plants within general industry and marine applications. These temperature sensors are based on a standardized Pt 100 or Pt 1000 element, which gives a reliable and accurate measurement. All three sensor types can be delivered with NTC / PTC elements on request. In the low temperature version (-50 200 C) the measuring insert is based on a silicone cable, which makes the sensor very resistant towards vibrations. The MBT 5250 with changeable measuring insert and MBT 5260 with fixed measuring insert are equipped with EN 175301-803-A, Pg 9 as standard. The MBT 5252 is equipped with a B-head as standard, but can also be delivered with B-mini Head on request. If needed, a transmitter (MBT 9110) can be ordered as an integrated part of the MBT 5252 sensor. Features Gaseous or liquid media, e.g. air, gas, vapour, water or oil. Up to 200 C media temperature (MBT 5250 and MBT 5260) Up to 200 C or 400 C media temperature (MBT 5252) Pt 100 or Pt 1000 sensing element Can be used with 2- or 3-wire connections Gold plated male and female connector (MBT 5250 and MBT 5260) MBT 5250 and MBT 5252 with interchangeable measuring insert MBT 5260 with fixed measuring insert Available with built-in transmitter (MBT 5252) Approvals Lloyds Register of Shipping, LR Germanischer Lloyd, GL Det Norske Veritas, DNV Registro Italiano Navale, RINA Nippon Kaiji Kyokai, NKK American Bureau of Shipping, ABS Korean Register of Shipping, KR Bureau Veritas, BV China Classification Society, CCS Danfoss DCS (im) 2016.09 IC.PD.P30.I6.02 520B7621 1

Technical data MBT 5250, MBT 5260 General data MBT 5250, MBT 5260 Measuring range -50 200 C Sensing element Pt 100, Pt 1000 ø8 1 mm Response times Type Indicative response times Water 0.2 m/s Air 1 m/s t 0.5 t 0.9 t 0.5 t 0.9 MBT 5250 with interchangeable measuring insert ø8 1 mm 9 s. 33 s. 95 s. 310 s. MBT 5260 with fixed meas. ins. ø8 1 mm 6 s. 20 s. 35 s. 140 s. Materials in contact with media W.no. 1.4571 (AISI 316 Ti) Process connection W.no. 1.4404 (AISI 316 L) Extension length W.no. 1.4571 (AISI 316 Ti) Union Nickel plated brass Gasket Silicone Plug EN 175301-803 PA 6.6 (max 125 C) Mechanical and environmental specifications Sensor tolerance EN 60751 Class B: ± (0.3 + 0.005 t) t = temperature of medium, numerical value Vibration stability Shock: Vibrations: Enclosure IP65 according to IEC 60529 Cable entry EN 175301-803 Pg 9, Pg 11 or Pg 13.5 100 g / 6 ms 4 g sine function 5 200 Hz, measured acc. to IEC 60068-2-6 2 520B7621 IC.PD.P30.I6.02 Danfoss DCS (im) 2016.09

Ordering standard (MBT 5250, MBT 5260) Type MBT 52X0 Sensor Measuring range, sensor element Tolerance -50 200 C 0 0 EN 60751 Class B 9 Other Sensing element 1 Pt 100 0 1 Pt 1000 (Class B only) 1 Process connection 2 Pt 100 2 0 None 2 Pt 1000 (Class B only) 3 1 G 1/4 A Other 9 2 G 1/2 A 3 1/2 14 NPT Protection Tube, W.nr. 1.4571 (AISI 316 Ti) 4 G ¾ A Acid-proof steel, ø8 1mm 0 5 M18 1.5 Other 9 9 Other Extension length None 0 50 mm 1 Insertion length Electrical Connections 050 mm 050 0 EN175301/803 excl. female plug 080 mm 080 1 EN175301/803 plug Pg 9 (IP65) 100 mm 100 2 EN175301/803 plug Pg 11 (IP65) 150 mm 150 3 EN175301/803 plug Pg 13,5 (IP65) 200 mm 200 8 ITT Canon 4 pins Au 250 mm 250 A EN175301/803 GL. plug Pg 13,5 (IP65) Sn pins xx0 mm xx0 B EN175301/803 Pg 9 4 pins without earth (IP65) C EN175301/803 Pg 11 4 pins without earth (IP65) Preferred versions 9 Other Danfoss DCS (im) 2016.09 IC.PD.P30.I6.02 520B7621 3

Technical data MBT 5250, MBT 5260 Max. temperature (Ext. length None ) Plug EN 175301-803 Max. load on protection tube (ø8 1, ø10 2) acc. to EN 175301-803 [ o C] [bar] [ o C] [ o C] T m = Media temperature T p = Temperature for electric plug T A = Ambient temperature L = Insertion length Note: for extension length = 50 mm no limitations up to 200 C media temperature and 90 C ambient temperature Permissible media velocity Process connection Max. tightening torque G ¼ A L = Insertion length Air Water 25 m/s 3 m/s G ½ A G ³ ₈ A M18 G ¾ A M24 25 Nm 50 Nm 100 Nm Dimensions MBT 5250, MBT 5260 Without extension length Gasket With extension length Plugs Pg 9, Pg 11 Pg 13.5 A = Extension length B = Insertion length C = D = Process connection E = Union Please note: y Tightening torque for the mounting screw at the rear end of the electrical connection plug: 25 Ncm y Tightening torque for the union (position E ): 17 Nm Process connection Width across flats 34,5 34,5 34,5 G ¼ All dimensions in millimeters G ¼ A G ½ A G ³ ₈ A M18 G ¾ A M24 HEX 22 HEX 27 HEX 32 Electrical connections 2-wire, 3 terminals (Ground not connected) 4 520B7621 IC.PD.P30.I6.02 Danfoss DCS (im) 2016.09

Technical data MBT 5252 General data MBT 5252 Measuring range -50 200 C or -50 400 C Sensing element Pt 100, Pt 1000 Low temperature: ø10 2 mm High temperature: ø11 1 mm Permissible media velocity Air 25 m/s. Steam 25 m/s. Water 3 m/s. Process connection G ¼ G ¼ A G ½ A G 3/₈ A M18 G ¾ A M24 Max. tightening torque 25 Nm 50 Nm 100 Nm Response time Type Indicative response times Water 0.2 m/s Air 1 m/s t 0.5 t 0.9 t 0.5 t 0.9 MBT 5252 ø10 2 mm 14 s. 42 s. 110 s. 390 s. MBT 5252 (HT) ø11 1 mm 25 s. 80 s. 150 s. 450 s. Mechanical and environmental specifications Max. ambient temperature 1 ) Sensors without transmitter 90 C Sensors with transmitter 85 C Sensor tolerance EN 60751 Class B: ± (0.3 + 0.005 t) t = temperature of medium, numerical value Vibration stability Shock: Vibrations: Enclosure IP65 according to IEC 60529 Cable entry B-head Pg16 Cable entry BM Pg 9 Temperature transmitter MBT 9110 Supply voltage: Output: 100 g / 6 ms 4 g sine function 5 200 Hz, measured acc. to IEC 60068-2-6 8 35 V d.c. 4 20 ma 1 ) The temperature of the transmitter is influenced by media temperature, ambient temperature and ventilation in the engine room. If the temperature of the transmitter exceeds the max. allowed temperature the transmitter must be data placed in a separated enclosure, as described in the separate sheet for MBT 9110. Materials in contact with media W.no. 1.4571 (AISI 316 Ti) Process connection W.no. 1.4404 (AISI 316 L) Extension length W.no. 1.4571 (AISI 316 Ti) Union nut Nickel plated brass Connection head Die cast aluminium Danfoss DCS (im) 2016.09 IC.PD.P30.I6.02 520B7621 5

Ordering standard Type MBT 5252 Sensor Transmitter Measuring range, sensor element -50 200 C 0 0 0 0 C (or none) -50 400 C 1 1 1 Transmitter setting, end of range Sensing element 3 3 Temperature range 220 C = 22 1 Pt 100 0 9 4 Temperature range 150 C = 15 2 Pt 100 (-50 200 C) 1 5 1. digit defines 100 s 1 Pt 1000 2 6 2. digit defines 10 s 2 Pt 1000 (-50 200 C) 3 7 Other 9 8 Protection Tube, W.nr. 1.4571 (AISI 316 Ti) 2 2 9 9 Other Acid-proof steel, ø8 mm (-50 200 C) 0 Transmitter setting, Acid-proof steel, ø10 mm (-50 200 C) 1 start of range Acid-proof steel, ø11mm (-50 400 C) 2 0 None Other 9 1 0 C 4-50 C Extension length 9 Other None 0 50 mm 1 100 mm 2 Other 9 Insertion length 50 mm 0050 0 None 100 mm 0100 G Standard Transmitter type As terminal block 150 mm 0150 L Standard EEx ia IIC T4/T6 200 mm 0200 In hightened lid 250 mm 0250 A Standard 300 mm 0300 J Standard EEx ia IIC T4/T6 400 mm 0400 B Galvanically isolated 500 mm 0500 9 Other xx0 mm Connection head xxx0 Connection B (IP65) 0 0 2-wire, 3 terminals B-mini (IP65) (only up to 4 terminals) (transmitter not possible) 1 1 4-wire, also to be used for 3 wire Other 9 2 2 wire, 2 terminals Process connection Tolerance G ¼ A (only ø8 mm protection tube) 0 0 EN 60751 Class B G ³ ₈ A 1 3 EN 60751 Class A G ½ A 2 9 Other G ¾ A 3 ½ 14 NPT 7 Other 9 Preferred versions 6 520B7621 IC.PD.P30.I6.02 Danfoss DCS (im) 2016.09

Technical data MBT 5252 Max. load on protection tube according to DIN 43763 ø11 1 [bar] ø8 1, ø10 2 [bar] [ o C] [ o C] L = Insertion length L = Insertion length Dimensions [mm] MBT 5252 Insertion length Extension length Welded Union nut ø10 x 2 Process connection Transmitter type MBT 9110, as terminal block Connection head, type B Pg 16 Also available with: Process connection G ½ A, ½ 14 NPT G ¾ A Width across flats HEX 27 HEX 32 Type: BM Danfoss DCS (im) 2016.09 IC.PD.P30.I6.02 520B7621 7

Electrical connections With temperature transmitter Without temperature transmitter 1 x Pt100 Without temperature transmitter 2 x Pt100 Danfoss DCS (im) 2016.09 IC.PD.P30.I6.02 520B7621 8