SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Laboratory Accreditation Programmes

National Voluntary Laboratory Accreditation Program

~W~~~ Laboratory Accreditation Program

National Voluntary Laboratory Accreditation Program

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. MiCOM LABS 1, Boulder Court Pleasanton, California USA Gordon Hurst Phone: (+1)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

National Voluntary Laboratory Accreditation Program

ANSI-ASQ National Accreditation Board/ACLASS

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC rd Drive S.E., Suite A Bothell, WA Steve Behm Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Accr. 002-Test EN-ISO (2005)

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

BIODEX MULTI- JOINT SYSTEM

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

IEC Second Edition

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC. 110 North Olinda Place Brea, CA Steve Behm Phone:

National Voluntary Laboratory Accreditation Program

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC Sierra Pines Drive Mariposa, CA Steve Behm Phone:

EMC Requirement for LED Lighting and Accessories & EMC Facilities in SIRIM

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

AS/NZS CISPR 14.2:2015

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Power Quality Issues from an EMC Point of View

American National Standard for Methods of Measurement. Frequency allocations and radio treaty matters; general rules and regulations

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

Biological Safety. Electromagnetic Compatibility (EMC) Observe the following precautions related to biological safety.

INTRODUCTION TO CONDUCTED EMISSION

Spurious Emissions & Emission Mark Report

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC Fulton Place Fremont, CA Steve Behm Phone:

EMC Test Report. Report Number: M030826

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

TEST REPORT FROM RFI GLOBAL SERVICES LTD

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

Astra Microwave Products Ltd. Environmental, EMI/EMC Test Facilities & Laser Welding

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC rd Drive S.E., Suite A Bothell, WA Steve Behm Phone:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EMC Test Report. SRT SO TDMA Class B AIS Transceiver Model: Iris AIS700

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. MiCOM LABS 575 Boulder Court Pleasanton, California USA Gordon Hurst Phone: (+1)

2620 Modular Measurement and Control System

EMC aspects associated to 5G networks

Schedule of Accreditation issued by. United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

English

General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits

ANSI-ASQ National Accreditation Board/ACLASS

Technical Criteria for the Accreditation Of Electromagnetic Compatibility (EMC) And Radio Testing Laboratories

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

Product Specification sheet

EUROPEAN ETS TELECOMMUNICATION November 1997 STANDARD

HEC-70LCN-350TDAF Rev B

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

HEC-45LTN-45PFAS Rev A

HeRO duet

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

Project: IEEE P Working Group for Wireless Personal Area Networks (WPANs)

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA

ENGINEERING TEST REPORT #: A LSR JOB #: C-2411

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Appendix A: Specifications

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

EMC Test report for LED Panel Light Models , , , , ,

HEC-30/35LTA-33TDAA Rev A

EMC Test Report FLOCKMAN. David Filmer Limited. for

HEC-35LTA-XXTSAA Rev A

Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques Electrostatic discharge immunity test

Immunity Testing for the CE Mark

Bilaga 2 / Appendix 2

TEST REPORT... 1 CONTENT...

Powered Traction Unit OPERATION MANUAL

EMC test report AU01+E04

Ackrediteringens omfattning/scope of accreditation

AS/NZS CISPR 14.1:2013

FS24W Series LED Driver Input: V High Power Factor High efficiency Subminiaturization IP66 SPECIFICATIONS

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

Global EMC Labs EMC / EMI Test Report

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

AP7301 ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY L T P C COURSE OBJECTIVES:

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

Transcription:

Trafalgar House Trafalgar Close Chandlers Ford Eastleigh SO53 4BW Contact: Mr R P St John James Tel: +44 (0)23 8027 1111 Fax: +44 (0)23 8027 1144 E-Mail: rob@hursley-emc.co.uk Website: www.emctesting.co.uk below Flexible Scope The Flexible Scope applies to the laboratory s accreditation to ISO/IEC17025:2005 for Civil and Military EMC testing activities in accordance with the standards listed on the schedule for EMC Testing, carried out at sites A and B. The scope may also include tests on the same or similar product types against standards, or customer-specified methods that are not specifically listed in this Schedule, providing that: (1) The method or standard does not introduce new principles of measurement. (2) The method or standard does not require measurements to be made outside the parametric boundaries defined in this Schedule. Information about flexible scopes of accreditation is available in UKAS document LAB 39. Laboratory locations: s covered by the organisation and their relevant activities details Activity code Address Trafalgar Close Chandler s Ford Eastleigh Hampshire SO53 4BW Local contact Mr R P St John James Tel: +44 (0)23 8027 1111 Fax: +44 (0)23 8027 1144 Email: rob@hursley-emc.co.uk Website: www.emctesting.co.uk EMC Testing A Address F Block Hursley Park Hursley Winchester Hampshire SO21 2JN Local contact Mr R P St John James Tel: +44 (0)23 8027 1111 Fax: +44 (0)23 8027 1144 Email: rob@hursley-emc.co.uk Website: www.emctesting.co.uk EMC Testing B Assessment Manager: CA Page 1 of 17

DETAIL OF ACCREDITATION Computers and Peripherals 1 CIVIL EMC TESTS Domestic Appliances: Electrical 1.1 Conducted Emissions EN 55011:1991 A, B Electrical/Electronic Products 9 khz to 30 MHz EN 55011:1998 including Electro-Mechanical Devices Amendment A1:1999 and IT Equipment A2:2002 Measuring Equipment EN 55011:2009 + A1:2010 EN 55011:2016 Medical/Dental Equipment EN 55011:2016+A1:2017 Office Equipment: Electrical CISPR 11:2009 + A1:2010 Radio and TV Equipment EN 55013:2001 including Security Equipment Amendment A1:2003 and Telecommunications A2:2006 Equipment (Radio receivers only) Luminaires EN 55014:1987 EN 55014-1:2000 including Amendment A1:2001 and A2:2002 EN 55014-1:2006 including Amendment A1:2009 and A2:2011 CISPR 14-1:2005 + A1:2008 + A2:2011 EN 55015:2013 including Amendment A1:2015 CISPR 15:2013 + A1:2015 LISN Method and Annex B EN 55015:2013 method in place of radiated EN 55015:2013 including emissions Amendment A1:2015 CISPR 15:2013 + A1:2015 EN 55022:1987 and 1994 EN 55022:1998 including Amendment A1:2000 and A2:2003 EN 55022:2006 including Amendment A1:2007 and A2:2010 EN55022:2010 Assessment Manager: CA Page 2 of 17

1.1 Conducted Emissions CISPR 22:2005 including A, B 9 khz to 30 MHz (cont d) Amendment A2:2006 CISPR 22:2008 VDE 0871:1978 CISPR 22:1985 and 1993 A1:1995, A2:1996 CISPR 22:1997 FCC/CFR 47:Part 15 FCC/CFR 47:Part 18 ANSI C63.4:1992 ANSI C63.4:2001 ANSI C63.4:2003 ANSI C63.4:2014 VCCI V-3/2010.04 VCCI V-4/2013.04 AS/NZ 2064:1997 AS/NZ 3548:1995 AS/NZ 4521:1997 CNS 13438:1997 CNS 13438:2006 CNS 13783-1:2004 CNS 13803:2003 SANS/SABS 222:1997 SANS/SABS 222:2006 CISPR 32:2012 EN 55032:2012 EN 55032:2015 (excluding outdoor home satellite receivers) CISPR 32:2015 (excluding outdoor home satellite receivers) 1.2 Radiated Emissions EN 55011:1998 including A, B Electric Field Amendment A1:1999 and 30 MHz to 40 GHz A2:2002 EN 55011:A2:2007 EN 55011:2009 + A1:2010 EN 55011:2016 EN 55011:2016+A1:2017 CISPR 11:2009 + A1:2010 EN 55013:2001 including Amendment A1:2003 and A2:2006, (up to 1GHz, Radio receivers only) Assessment Manager: CA Page 3 of 17

1.2 Radiated Emissions (cont d) Magnetic Field EN 55014:1987 A, B 10 khz to 30 MHz EN 55014-1:2000 including Amendment A1:2001 and A2:2003 EN 55014-1:2006 including Amendment A1:2009 and A2:2011 CISPR 14-1:2005 + A1:2008 + A2:2011 Magnetic Field LLA EN 55015:2013 9 khz to 30 MHz EN 55015:2013 including Amendment A1:2015 CISPR 15:2013 + A1:2015 Electric Field EN 55022:1987 and 1994 30 MHz to 40 GHz EN 55022:1998 including Amendment A1:2000 and A2:2003 EN 55022:2006 including Amendment A1:2007 and A2:2010 EN55022:2010 CISPR 22:1985 and 1993 A1:1995, A2:1996 CISPR 22:1997 CISPR 22:2005 including Amendment A2:2006 CISPR 22:2008 VDE 0871:1978 FCC/CFR 47:Part 15 FCC/CFR 47:Part 18 ANSI C63.4:1992 ANSI C63.4:2001 ANSI C63.4:2003 ANSI C63.4:2014 VCCI V-3/2010.04 VCCI V-4/2013.04 AS/NZ 2064:1997 AS/NZ 3548:1995 AS/NZ 4521:1997 Assessment Manager: CA Page 4 of 17

1.2 Radiated Emissions (cont d) Electric Field EC Directive 2004/104/EC, 30 MHz to 40 GHz Annex 7 and 8 EC Directive 95/54/EC, Annex 7 and 8 CNS 13438:1997 CNS 13438:2006 CNS 13783-1:2004 CNS 13803:2003 SANS/SABS 222:1997 SANS/SABS 222:2006 CISPR 32:2012 EN 55032:2012 EN 55032:2015 (excluding outdoor home satellite receivers) CISPR 32:2015 (excluding outdoor home satellite receviers) Assessment Manager: CA Page 5 of 17

1.3 Discontinuous Emissions EN 55014-1:2000 including A, B (Clicks) Amendment A1:2001 and 10 khz to 30 MHz A2:2002 EN 55014-1:2006 including Amendment A1:2009 and A2:2011 CISPR 14-1:2005 + A1:2008 + A2:2011 1.4 Interference Power EN 55014-1:2000 including A, B Measurements Amendment A1:2001 and 30 MHz to 300 MHz A2:2002 EN 55014-1:2006 including Amendment A1:2009 and A2:2011 CISPR 14-1:2005 + A1:2008 + A2:2011 1.5 Conducted RF Immunity ENV 50141:1995 A, B 150 khz to 230 MHz EN 61000-4-6:1996 including up to 10 Vrms Amendment A1:2001 IEC 61000-4-6:2003 including IEC 61000-4-6:1996 Amendment A1:2004 EN 61000-4-6:2007 EN 61000-4-6:2009 EN 61000-4-6:2014 IEC 61000-4-6:2003 including Amendment A1:2004 & A2:2006 1.6 Radiated RF Immunity IEC 801-3:1984 A, B 10 Vm -1 ENV 50140:1995 26 MHz to 6 GHz ENV 50204:1995 20 Vm -1 EN 61000-4-3:1996 26 MHz to 3000 MHz including Amd 1:1999 IEC 61000-4-3:1995 including Amendment A1:1998 EN 61000-4-3:2002 EN 61000-4-3:2006 EN 61000-4-3:2006 including Amendment A1:2008 & A2:2010 Assessment Manager: CA Page 6 of 17

1.6 Radiated RF Immunity (cont d) IEC EN 61000-4-3:2006 A, B 10 Vm -1 including Amendment 26 MHz to 6 GHz A1:2008 & A2:2010 20 Vm -1 EN 50121-4:2006 26 MHz to 3000 MHz 1.7 Immunity to Fast Transients/ IEC 801-4:1988 A, B Bursts EN 61000-4-4:1995 including up to 4.5 kv Amendment A2:2001 IEC 61000-4-4:1995 EN 61000-4-4:2004 EN 61000-4-4:2004 including Amendment A1:2010 IEC 61000-4-4:2004 including Amendment A1:2010 EN 61000-4-4:2012 1.8 Immunity to Mains Surge EN 61000-4-5:1996 including A, B up to 6 kv Amendment A1:2001 IEC 61000-4-5:1995 EN 61000-4-5:2006 IEC 61000-4-5:2005 EN 61000-4-5:2014 1.9 Mains Harmonic Emissions EN 60555-2:1987 A, B 50 Hz to khz EN 61000-3-2:1995 EN 61000-3-2:2000 EN 61000-3-2:2006 including Amendment A1:2009 & A2:2009 IEC 61000-3-2:2005 including Amendment A1:2008 & A2:2009 EN 61000-3-2:2014 Assessment Manager: CA Page 7 of 17

1.10 Mains Flicker Emissions EN 60555-3:1987 A, B EN 61000-3-3:1995 including Amendment A1:2001 and A2:2005 EN 61000-3-3:2008 IEC 61000-3-3:2008 EN 61000-3-3:2013 IEC 61000-3-3:2013 1.11 Electrostatic Discharge IEC 801-2:1984 and 1991 A, B up to 30 kv EN 61000-4-2:1995 including Amendment A1:1999 and IEC 61000-4-2:1995 including Amendment A1:1998 & A2:2000 A2:2001 EN 61000-4-2:2009 IEC 61000-4-2:2008 1.12 Voltage Dips, Interruptions EN 61000-4-11:1994 including A, B and Variations Amendment A1:2001 IEC 61000-4-11:1994 EN 61000-4-11:2004 EN 61000-4-11:2004 + A1:2017 IEC 61000-4-11:2004 1.13 Power-Frequency Magnetic EN 61000-4-8:1993 including A, B Fields (Immunity) Amendment A1:2001 IEC 61000-4-8:1993 including Amendment A1:2000 EN 61000-4-8:2010 Field strength: up to 30 A/m IEC 61000-4-8:2009 1.14 Pulse Magnetic EN 61000-4-9:2004 A Immunity IEC 61000-4-9:1993 Field strength: 1000 A/m EN 61000-4-9:1993 including Amendment A1:2001 Assessment Manager: CA Page 8 of 17

1.15 Damped Oscillatory Magnetic EN 61000-4-10:1994 A Field Immunity EN 61000-4-10:1994+A1:2001 100 khz and 1 MHz EN 61000-4-10:2016 1.16 Ring Wave Immunity EN 61000-4-12:1996 A 100 khz at up to 6 kv EN 61000-4-12:2006 1.17 Damped Oscillatory Wave EN 61000-4-18:2006 A immunity EN 61000-4-18:2006+A1:2010 100 khz and 1 MHz Slow waves only Up to 6 kv Maritime Navigation and 1.18 EMC Tests BS EN 60945:1997 A, B Radio IEC 945:1996 Communication Equipment IEC 60945:2002 DNVGL-CG-0339:2015 Household Products Luminaires 1.19 Electro-Magnetic field emissions relating to Human Exposure EN 50366:2003 including Amendment A1:2006 EN 62233:2008 10 Hz to 10 MHz Time Domain Evaluation Method EN 62493:2010 A, B Electrical / electronic 1.20 Compass safe distance BS EN 60945:1997 A, B equipment mounted in ships IEC 945:1996 where Compass is present IEC 60945:2002 Assessment Manager: CA Page 9 of 17

1.21 EMC Tests IEC 61000-6-1:2005 A, B IEC 61000-6-2:2005 These generic and product specific IEC 61000-6-3:2006 standards are included but limited IEC 61000-6-3:2006+A1:2010 IEC 61000-6-4:2006 to those referenced standards that IEC 61000-6-4:2006+A1:2010 are explicitly listed in Sections 1.1 EN 61000-6-1:2001 to 1.17 of this Schedule. EN 61000-6-2:1999 EN 61000-6-2:2001 EN 61000-6-3:2001 including Amendment A11:2004 EN 61000-6-3:2006 including Amendment A1:2010 EN 61000-6-4:2001 EN 61000-6-1:2007 EN 61000-6-2:2005 EN 61000-6-3:2007 EN 61000-6-3:2007 including Amendment A1:2011 EN 61000-6-4:2007 EN 61000-6-4:2007 including Amendment A1:2011 IEC 61000-6-4:2006 including Amendment A1:2010 pren 50082-1:1996 CISPR 16-1:1999 CISPR 16-2:1999 CISPR 24:1997 including Amendment A1:2001 and A2:2002 (excluding Psophometric tests) EN 55024:2010 excluding Psophometric tests EN 55024:2010 + A1:2015 (excluding Psophometric tests) CISPR 24:2010 (excluding Psophometric tests) CISPR 24: 2010 + A1:2015 (excluding Psophometric tests) SANS/SABS 224:1997 EN 50091-2:1995 EN 55014-1:1993 including Amendment A1:1997 EN 55014-1:2006 including Amendment A1:2009 and A2:2011 Assessment Manager: CA Page 10 of 17

1.21 EMC Tests (cont d) CISPR 14-1:2005 A, B + A1:2008 + A2:2011 EN 55014-2:1997 including Amendment A1:2001 and A2:2008 EN 55014-2:2015 CISPR 14-2:2015 EN 55103-1:1996 EN 55103-1:2009 EN 55103-1:2009 including Amendment A1:2012 EN 55103-2:1996 EN 55103-2:2009 EN 60601-1-2:1993 EN 60601-1-2:2001 EN 60601-1-2:2007 IEC 60601-1-2:2014 EN 61204-3:2000 IEC 61204-3:2000 EN 61326-1:1998 including Amendment A2:2001 and A3:2003 EN 61326-1:2013 EN 61326-1:2006 EN 61326-2-3:2006 TRG 1068:1991 ETS 300 339:1997 ETS 300 342-1:1994 ETS 300 342-2:1994 ETS 300 385:1996 EN 300 386 V1.3.3:2005 EN 300 386:V1.3.2:2003 ETS 300 386:1997 EN 301 489-1:V1.4.1:2002 EN 301 489-1:V1.9.2:2011 EN 301 489-3:V1.4.1:2002 EN 301 489-3:V1.6.1:2013 EN 301 489-4:V1.3.1:2002 EN 301 489-5:V1.3.1:2002 EN 301 489-17:V2.2.1:2009 EN 301 489-23:V1.2.1:2002 EN 301 489-24:V1.2.1:2002 EN 301 489-24:V1.6.1:2010 Assessment Manager: CA Page 11 of 17

1.21 EMC Tests (cont d) EN 50130-4:1995 including Amendment A1:1998 and A2:2003 EN 50130-4:2011 EN 50130-4:2011 including Amendment A1:2014 EN 50131-1:1997 EN 55024:1998 including Amendment A1:2001 and A2:2003 (excluding psophometric tests) EN 50270:1999 EN 50270:2006 EN 50293:2000 EN 50293:2012 EN 60730-1:2001 Sections 26 EN 60669-2-1:2004 Section 26 EN 61547:1995 A1:2000 EN 61547:2009 EN 54-21:2006* EN 50136-2-1:1998* *the radiated immunity test is accredited for frequencies of 80 MHz and above. EN 50270:2015 (excluding DC power port EN 61000-4-29 tests) KN 32: 2013 KN 35: 2013 (excluding psophometric tests) EN 55035:2017 A, B Assessment Manager: CA Page 12 of 17

2 MILITARY AND AEROSPACE EMC TESTS 2.1 Conducted Emissions: DEF STAN 59-41:Issue 5, A Power, Control and Signal DCE01 and DCE02 Leads: DC to 400 MHz DEF STAN 59-41:Part 3, Section 3, Issue 1:2003 DCE01 and DCE02 RTCA/DO-160D, E & F and G:Section 21 DEF STAN 59-411 Part 3 Iss 1 DCE01.B, DCE02.B DEF STAN 59-411 Part 3 Iss 2 DCE01.B, DCE02.B MIL STD 461D, E & F CE 101 & CE 102 2.2 Radiated Emissions: DEF STAN 59-41:Issue 5, A Electric Field: DRE01 10 khz to 18 GHz DEF STAN 59-41:Part 3, Section 3, Issue 1:2003 DRE01 RTCA/DO-160D, E & F and G:Section 21 DEF STAN 59-411 Part 3 Iss 1 DRE01.B DEF STAN 59-411 Part 3 Iss 2 DRE01.B MIL STD 461D, E & F RE 102 & RE103 2.3 Radiated Emissions: DEF STAN 59-41:Issue 5, A Magnetic Field: DRE02 20 Hz to 100 khz DEF STAN 59-41:Part 3, Section 3, Issue 1:2003 DRE02 RTCA/DO-160D, E & F and G:Section 21 DEF STAN 59-411 Part 3 Iss 1 DRE02.B DEF STAN 59-411 Part 3 Iss 2 DRE02.B MIL STD 461D, E & F RE101 Assessment Manager: CA Page 13 of 17

2 MILITARY AND AEROSPACE EMC TESTS (cont d) 2.4 Exported Transients DEF STAN 59-41:Issue 5 A Power Lines DCE03 DEF STAN 59-41:Part 3, Section 3, Issue 1:2003 DCE03 2.5 Conducted DEF STAN 59-41:Issue 5 A Susceptibility: DCS01 Primary Power Lines, DEF STAN 59-41:Part 3, 20 Hz - 50 khz Section 3, Issue 1:2003 DCS01 DEF STAN 59-411 Part 3 Iss 1 DCS01.B DEF STAN 59-411 Part 3 Iss 2 DCS01.B MIL STD 461D, E & F CS101 2.6 Conducted DEF STAN 59-41:Issue 5 A Susceptibility: Power, DCS02 and DCS03 Control and Signal DEF STAN 59-41:Part 3, Lines including Bulk Section 3, Issue 1:2003 Current Injection DCS02 and DCS03 10 khz to 400 MHz DEF STAN 59-411 Part 3 Iss 1 DCS02.B & DCS03.B DEF STAN 59-411 Part 3 Iss 2 DCS02.B & DCS03.B MIL STD 461D, E & F CS106, CS109 CS114 & CS 115 2.7 Damped Sinusoidal Transients MIL STD 461D, 461E & 461F A Cables and Power Leads CS 116 10 khz to 100 MHz Assessment Manager: CA Page 14 of 17

2 MILITARY AND AEROSPACE EMC TESTS (cont d) 2.8 Radiated Susceptibility: DEF STAN 59-41:Issue 5 A Magnetic Field: DRS01 20 Hz to 100 khz DEF STAN 59-41:Part 3, Section 3, Issue 1:2003 DRS01 DEF STAN 59-411 Part 3 Iss 1 DRS01.B DEF STAN 59-411 Part 3 Iss 2 DRS01.B MIL STD 461D, E & F RS101 2.9 Radiated Susceptibility: DEF STAN 59-41:Issue 5 A Electric Field: DRS02.3 150 khz to 1 GHz SEF STAN 59-41:Part 3, Maximum Field Section 3, Issue 1:2003 Strength: 20 V/m DRS02.3 1 GHz to 18 GHz DEF STAN 59-411 Part 3 Iss 1 Maximum Field DRS02.B DEF STAN 59-411 Part 3 Iss 2 DRS02.B Strength: 10 V/m MIL STD 461D, E & F RS103 2.10 Electrostatic Discharge DEF STAN 59-41:Issue 5, A DCS10 DEF STAN 59-41:Part 3, Section 3, Issue 1:2003 DCS10 DEF STAN 59-411 Part 3 Iss 1 DCS10.B DEF STAN 59-411 Part 3 Iss 2 DCS10.B 2.11 Magnetostatic Field DEF STAN 59-411:Part 3 Iss 1 A Susceptibility DRS03 800 A/m DEF STAN 59-411:Part 3 Iss 2 DRS03 2.12 Compass safe distance DO 160F Section 15 A,B Assessment Manager: CA Page 15 of 17

SECTION 3 EU US MRA Accredited Scope UNINTENTIONAL RADIATORS FCC test requirements Conducted Emissions ANSI C63.4-2014 A, B 9 khz to 30 MHz FCC CFR 47 Part 15 B Radiated Emissions 9 khz to 40 GHz INDUSTRIAL, SCIENTIFIC Conducted Emissions FCC MP-5 (February 1986), A, B AND MEDICAL 9 khz to 30 MHz FCC CFR 47 Part Part 18 EQUIPMENT Consumer ISM Equipment Radiated Emissions 9 khz to 40 GHz INTENTIONAL RADIATORS Conducted Emissions ANSI C63.10-2013 A, B BELOW 26.5 GHz 9 khz to 30 MHz FCC CFR 47 Part 15 C Radiated Emissions 9 khz to 40 GHz Radio tests as per standard. Includes but not limited to: Peak transmit power Emission bandwidth / Occupied BW Modulation Power spectral density Band edge tests Permitted Frequency range In-band unwanted emissions Out-of-band emissions Spurious Emissions Reaction time Frequency and Time Stability Assessment Manager: CA Page 16 of 17