Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Similar documents
Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only* 2013 CEC

Energizing a world that demands more

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Series NRX with PXR - Instructions for Neutral Current Sensor Type NF

Installation Manual. Arc Chamber

FSEC APPROVAL # XL15-NT

Power-Sure 700. Technical Data TD158001EN. Contents

CP /240-MC4 User Manual

Electrical Wiring: Commercial, Seventh Canadian Edition

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT

Jake Leahy s Electrical Code Connection. A look at Grounding and Bonding of Electrical Services Article Florida Building Code 5 th Edition

Electronics Solutions

Short Circuit Current Calculations

POWER SERVICE DETAILS

Ampgard The name motor applications rely on

A compact, integrated solution for medium voltage connection, transformer and low voltage distribution

Code Check Electrical is a field guide to common code issues in residential

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

Energy Management Service

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings

2014 NEC Changes Part 1

3Ø Short-Circuit Calculations

DC PV Arc fault detection Unit

DC Current Transducers

2. Determine the number of Modules/Microinverters required. (1134 modules is 2 less than 250 KW but works well with max comm.

Code Red: Notable Changes in the 2011 NEC

Table K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

Supplemental Calculation Sheets for Inverter #2

Short-Circuit Current Calculations

Article 225: Outside Branch Circuits And Feeders

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only*

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Strategies for design 600V large modular UPS for critical power applications

B. Manufacturers: Square-D, G.E. or Westinghosue.

Page Electric Utility Service Specifications

System Components and Accessories

Heavy Duty Safety Switches

NEMA Size 1 Cat. No. CN55DN3AB

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Note: The let-through of the protective device must be equal to or less than the short-circuit current rating of the component being protected.

American Electrical Institute

Article 250 Grounding & Bonding

Installation/User Manual

Open Type Without Enclosure

Advanced Pulse WattNode - Option PV (Photovoltaic)

Harmonic mitigating transformers. Energy savings through harmonic mitigation

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof

Ground Fault Isolation with Loads Fed from Separately Derived Grounded Sources

Recp/Nightlight Combo 15A 125V TR, Iv

SECTION PANELBOARDS

Tel: Fax:

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials.

PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer

MODEL AT-10 ANALOG TRANSMITTER

Alternating Current Power

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Wiring of the Main Distribution Panelboard

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

PV Array Commissioning and Troubleshooting. Solmetric PV Analyzer

ULTRA-K Series 600K - he

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

PF/PFQ. High Amperage plug and receptacle. Main Advantages

IRRIGATION 810-3R RECEIVER GUIDE

Liebert Datawave. GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL

The Variable Threshold Neutral Isolator (VTNI)

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

More Complete Protection

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

8.3. Terminal Blocks, Fuse Blocks and Fuse Holders. Contents Description. CHDB Series Power Distribution Blocks. Power Distribution

HPS Universal BUCK-BOOST TRANSFORMERS

For Medium Voltage Motors, Generators, Switchgear, Bus Duct and Cable Terminations

SI TRUE DC Solar Isolator

Specialty Switches. Inertia Engineering & Machine Works, Inc Hardaway Road, Stockton CA 95215

Datawave Magnetic Synthesizer

RESIDENTIAL SOLAR ROOF TOP EXPEDITED PERMITTING GUIDELINE. 10 KW OR LESS

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

Design and Development of Prototype Three Level NPC Inverter for Industrial Application

Installation requirements

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

SECTION TRANSFORMERS

Power-IO

SECTION CABLE TRAYS

CBCT TM CIRCUIT BREAKER COIL TESTER

Wisconsin Contractors Institute Continuing Education

RW single and dual-output converters AC and DC inputs, 2 28Vout, watts

Planning and Building Services Solar PV Standard Plan Simplified Central/String Inverter Systems (One- and Two-Family Dwellings)

NEMA Contactor and Starter Specifications

Transcription:

Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations

Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these new green technologies is the use of photovoltaic (PV) panels (modules) to generate power from the sun. PV modules directly convert the sun s light into electricity, providing power during daylight hours. PV systems are being installed on virtually every type of building, resulting in a growing need for products to meet the requirements of these systems. 2 EATON CORPORATION

Switching 600 Vdc When photovoltaic panels convert the sun s energy into electricity, the power generated is direct current (DC). Typically, the systems are designed with DC system voltages in the 400 600V range. This is much higher voltage than typically found in building systems. The higher voltage, when combined with the lack of a current sine wave with zero crossings, creates a number of challenges in wiring, particularly when switching circuits on and off. DC circuits consist of two wires a positive and a negative. In most PV systems, one of these wires is grounded (like a neutral in an AC system). Which of the two wires is grounded is specified by the solar panel manufacturer. The more common application is a negative ground, and the location of this bond is usually found at the inverter. Per the National Electrical CodeT (NECT) Section 690.5(A), only the current-carrying ungrounded conductor should be switched. Thus, in a negative-grounded system, only the positive wire is switched. Unlike AC systems that possess a current sine wave with zero crossings, the interruption of higher voltage DC circuits requires an increased air gap to safely and quickly interrupt and break the arc. The increased gap is accomplished by wiring multiple poles of a single switch in series for safe arc interruption. All switch manufacturers require the use of multiple poles at 600 Vdc to maintain the ULT listing. For this reason, a switch should only be used to switch one circuit. The UL listing of these products does not permit multiple circuits to be switched by one switch. Eaton s new offering of PV switches have multiple poles factory-wired, and they are approved for NEC Article 690 applications right from the box. Other manufacturers require the contractor to add jumpers to a two- or three-pole switch, add a neutral, and add labels to meet this requirement. For fusible switches, the new Eaton PV switch requires only one fuse per switch saving the customer at least one fuse on each switch. Eaton s solar disconnect Eaton Corporation is proud to offer a new line of solar disconnects that provide the best solution for switching solar PV circuits. This exciting new offering is the first UL 98 listed switch that is labeled as suitable for NEC Article 690 photovoltaic applications per UL 1741 requirements. Features include: Marked as suitable for NEC 690 PV applications up to 600 Vdc UL 98 listed All switches are single-pole and suitable for switching one circuit Clear polycarbonate deadfront to guard against accidental contact with live parts NEC 690.17 compliant labeling warning that the switch terminals may be energized in the open position NEC 690.14.(C) 2 required PV System Disconnect label included Isolated ground terminals (neutral) for grounded conductors Ground lug for equipment grounding conductor NEMAT 3R, 12 and 4X stainless enclosures Fusible and non-fusible configurations Class R fuse clips standard Fuse clips are located on the center pole to ensure that both fuse clips are de-energized meets NEC Article 690.16, which requires isolation of the fuse from all potential supply sources Available for Flex Center modifications (windows, pilot lights, 316 grade stainless, and so on) 3 EATON CORPORATION

Non-Fusible 600 Vdc Wiring Diagram Ampere Rating NEMA 3R NEMA 12 NEMA 4X Lug Capacity Main and Neutral (Isolated Ground) Ground Lug NEC Rated Short Circuit Current (ISC) B Non-Fused Construction 30 DH161URKN DH161UDKN DH161UWKN #2 #14 Cu/Al #4 #14 Cu/Al 19.2A 60 DH162URKN DH162UDKN DH162UWKN #2 #14 Cu/Al #4 #14 Cu/Al 38.4A Line 100 DH163URKN DH163UDKN DH163UWKN 1/0 #14 Cu/Al #4 #14 Cu/Al 64.0A 200 DH164URKN DH164UDKN DH164UWKN 250 kcmil #6 Cu/Al #2 #14 Cu/Al 128.0A Grounded 400 DH165URKN DH165UDKN DH165UWKN (1) 750 kcmil 1/0 or 250 kcmil #6 Cu/Al 256.0A Conductor (2) 300 kcmil 1/0 Cu/Al Junction Block 600 DH166URKN DH166UDKN DH166UWKN (1) 750 kcmil 1/0 and 250 kcmil #6 Cu/Al 384.0A Load (1) 600 kcmil #2 Cu/Al Fusible 600 Vdc (Class R Fuse Clips one fuse required per switch) Wiring Diagram Ampere Rating NEMA 3R NEMA 12 NEMA 4X Lug Capacity Main and Neutral (Isolated Ground) Ground Lug Fused Construction 30 DH161NRK DH161NDK DH161NWK #2 #14 Cu/Al #4 #14 Cu/Al 19.2A Line 60 DH162NRK DH162NDK DH162NWK #2 #14 Cu/Al #4 #14 Cu/Al 38.4A 100 DH163NRK DH163NDK DH163NWK 1/0 #14 Cu/Al #4 #14 Cu/Al 64.0A Grounded 200 DH164NRK DH164NDK DH164NWK 250 kcmil #6 Cu/Al #2 #14 Cu/Al 128.0A Conductor 400 DH165NRK DH165NDK DH165NWK (1) 750 kcmil 1/0 or 250 kcmil #6 Cu/Al 256.0A Junction Block (2) 300 kcmil 1/0 Cu/Al 600 DH166NRK DH166NDK DH166NWK (1) 750 kcmil 1/0 and (1) 600 kcmil #2 Cu/Al 250 kcmil #6 Cu/Al 384.0A Load A UL 98 limits the conductor current sizing to 75 C. 90 C wire may be terminated per Article 110.14(C); however, the maximum current capacity is limited to NEC Table 310.16, 75 C column. B The NEC Rated ISC is calculated by applying two 25% derating factors per NEC 690.8. Thus, a 30A disconnect has an ISC Rating of 19.2A because: 30 / 1.25 / 1.25 = 19.2. The first 25% derating is due to the fact that PV output circuits can deliver output currents higher than the rated short circuit current for more than 3 hours near solar noon. The second derating 690.9(B)(1) for the circuit conductors is because PV system currents are considered to be continuous. Rated ISC B 600 Vdc Solar Switches Features and Benefits NEC Required Labeling B B Factory-Installed Jumpers F C C Standard K-Switch Mechanism D Clear Deadfront Shield Covering all potentially live parts F B E D E Fused Center Pole Isolates fuse clips from potential back feed only one fuse required per switch F Factory Installed Isolated ground and equipment ground lug EATON CORPORATION 4

B C B C A A Type 3R Solar Switch Dimensions Type 12-3R and 4X Solar Switch Dimensions Type 3R Solar Switch Dimensions Amps A B C Main Lug Capacity Ground Lug Capacity 30 16.35 8.87 9.89 #2 AWG #14 AWG Cu/Al #4 AWG #14 AWG Cu/Al 60 16.35 8.87 9.89 #2 AWG #14 AWG Cu/Al #4 AWG #14 AWG Cu/Al 100 22.15 11.84 9.89 1/0 AWG #14 AWG Cu/Al #4 AWG #14 AWG Cu/Al 200 28.27 16.66 11.26 250 kcmil #6 AWG Cu/Al #2 AWG #14 AWG Cu/Al 400 45.00 24.12 12.39 (1) 750 kcmil 1/0 or (2) 300 kcmil 1/0 Cu/Al 250 kcmil #6 AWG Cu/Al 600 52.50 25.12 14.07 (1) 750 kcmil 1/0 and (1) 600 kcmil #2 AWG Cu/Al 250 kcmil #6 AWG Cu/Al Type 12-3R and 4X Solar Switch Dimensions Amps A B C Main Lug Capacity Ground Lug Capacity 30 Non-fusible 14.14 8.76 10.22 #2 AWG #14 AWG Cu/Al #4 AWG #14 AWG Cu/Al 30 Fusible 19.08 8.76 10.22 #2 AWG #14 AWG Cu/Al #4 AWG #14 AWG Cu/Al 60 Non-fusible 14.14 8.76 10.22 #2 AWG #14 AWG Cu/Al #4 AWG #14 AWG Cu/Al 60 Fusible 19.08 8.76 10.22 #2 AWG #14 AWG Cu/Al #4 AWG #14 AWG Cu/Al 100 24.95 11.79 10.22 1/0 AWG #14 AWG Cu/Al #4 AWG #14 AWG Cu/Al 200 35.38 16.95 11.63 300 kcmil #6 AWG Cu/Al #2 AWG #14 AWG Cu/Al 400 57.47 24.12 12.43 (1) 750 kcmil 1/0 or (2) 300 kcmil 1/0 Cu/Al 250 kcmil #6 AWG Cu/Al 600 63.00 26.34 14.25 (1) 750 kcmil 1/0 and (1) 600 kcmil #2 AWG Cu/Al 250 kcmil #6 AWG Cu/Al A UL 98 limits the conductor current sizing to 75 C. 90 C wire may be terminated per Article 110.14(C); however, the maximum current capacity is limited to NEC Table 310.16, 75 C column. EATON CORPORATION 5

Eaton s Electrical Sector is a global leader in power distribution, power quality, control and automation, and monitoring products. When combined with Eaton s full-scale engineering services, these products provide customer-driven PowerChain ManagementT solutions to serve the power system needs of the data center, industrial, institutional, public sector, utility, commercial, residential, IT, mission critical, alternative energy and OEM markets worldwide. PowerChain Management solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle, resulting in enhanced safety, greater reliability and energy efficiency. For more information, visit www.eaton.com/electrical. Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com 2010 Eaton Corporation All Rights Reserved Printed in USA Publication No. PA00801007E / Z9555 February 2010 PowerChain Management is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.