Advanced Test Equipment Rentals ATEC (2832) EMC Calibration ServiCES. Reliable fast worldwide

Similar documents
GTEM cells. Emissions and immunity testing in a single, shielded environment

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

Advanced Test Equipment Rentals ATEC (2832) ADVANCED TEST SOLUTIONS FOR EMC COMPANY PROFILE AND PRODUCT OVERVIEW

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z540.3

A A COMPANY PROFILE AND PRODUCT OVERVIEW. a TESEQ Company. a TESEQ Company

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL A

For the National Voluntary Laboratory Accreditation Program

ACCREDITED LABORATORY. LIBERTY LABS, INC. Kimballton, IA for technical competence in the field of Calibration

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. TOKIN EMC ENGINEERING CO., LTD Hanashimashinden, Tsukuba-shi, Ibaraki Japan

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

Test Systems. VSQ 3000/3002 Reference Radiation Source up to 3GHz

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

THE MODULAR SOLUTION FOR 6 KV APPLICATIONS

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

EMC Test Facility Sale

CBA 400M MHZ to 400 MHZ

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

EMC standards. Presented by: Karim Loukil & Kaïs Siala

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

INA 703 MAgNetIc field coil

Semi Anechoic Chamber (SAC)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Accredited calibration of field strength meters

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

MD 103 ESD TargET SET USEr ManUal B

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

FCC PART 15 B MEASUREMENT AND TEST REPORT

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Advanced Test Equipment Rentals ATEC (2832) CNE III Comparison Noise Emitter

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

1 Introduction Test Specification Environment Relevant standards Emissions Immunity...

1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2

CE EMC Test Certification

Test Centre Facilities Regulatory Test Lab

CE TEST CERTIFICATION

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

EMC & Electrical Test Laboratory EMC LAB EQUIPMENT RESOURCES PER OEM TEST METHOD EQUIPMENT DCX FORD GM

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

CS114 + CS115 + CS116

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Calibration and Validation for Automotive EMC

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. MiCOM LABS 1, Boulder Court Pleasanton, California USA Gordon Hurst Phone: (+1)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 EMC TEST REPORT. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger

CE TEST CERTIFICATION

EMC TEST EQUIPMENT & E M C PRODUCT OVERVIEW

1 - GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES...

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Double-Ridged Waveguide Horn

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

MD 200A High voltage differential probe

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Advanced Test Equipment Rentals ATEC (2832) INA A

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

Technical Criteria for the Accreditation Of Electromagnetic Compatibility (EMC) And Radio Testing Laboratories

CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

EMI Measuring Receiver & Analyzer 10 Hz-3 GHz

Advanced Test Equipment Rentals ATEC (2832)

NSG Hard keys for important functions. 5.7 color display, easy to use firmware. 3 power meter

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

COMPACT NX5 FIRST OF ITS KIND. SHOWS ITS TRUE COLORS. THINKS FOR ITSELF.

EMC LAB EQUIPMENT CALIBRATION SCHEDULER

Nsg inductive switch transient test circuit

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

CONDUCTED IMMUNITY EMC TEST SYSTEM

DCD SR - SERIES COUPLING/DECOUPLING NETWORKS FOR UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES

CERTIFICATE. Issued Date: Apr. 02, 2009 Report No.: R-ITUSP01V01

Test and Measurement for EMC

RF Conducted Immunity and Automotive Transient Generator Test Systems

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

EMC ANECHOIC CHAMBERS 5-METER CHAMBERS

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Radiated Immunity Test System 6 GHz

TEST SUMMARY. Prüfbericht - Nr.: Test Report No FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed % BANDWIDTH RESULT: Passed

Radiated immunity test system 6 GHz

TEST REPORT. Power Spout PLT V. tested to the specification

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

EMC Test Report. Report Number: M030826

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

EMC test report AU01+E04

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

CENTRE OF TESTING SERVICE INTERNATIONAL

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) EMC Calibration ServiCES Reliable fast worldwide

GLOBAL 6 accredited calibration and repair centers. NATIONAL Accredited and traceable calibrations. National and international standards.

SERVICE YOU CAN TRUST Get your calibration services from the EMC experts who also develop and manufacture EMC test instruments. Teseq provides calibration and repair services for a wide range of EMC test equipment from all manufacturers, including the complete Teseq product line. Our worldwide certified calibration centers provide a wide range of value-added services, including upgrades, system tuning and modifications to meet the latest standards. We also provide on-site calibration and repair services. In support of our commitment to world-class customer service, Teseq guarantees 7 years of post phase-out support on all our products, including test instruments sold under the Schaffner label. ON-SITE On-site calibration. Fast turnaround for send-in service. KNOW-HOW Membership in standards committees. Calibration of any EMC manufacturer s equipment. 3

Teseq Service Touchpoints Reduce down-time for test equipment REPAIR, ADJUSTMENT AND CALIBRATION CALIBRATION ONLY REPAIR REPAIR, ADJUSTMENT AND CALIBRATION On-site calibration: The fastest way for critical instruments Reduce down-time for critical test equipment and avoid costly shipping charges for large systems by taking advantage of our on-site calibration service. In addition to normal RF and power line EMC instrumentation, Teseq also performs on-site calibration for anechoic test chambers and open area test sites (OATS). Ship to Teseq Service Lab: Fast, reliable, high-quality service Teseq has 6 worldwide accredited calibration and repair labs with industry leading turnaround times. We provide timely, cost-effective modifications and upgrades to accommodate new standards, as well as free firmware updates for increased performance to protect your investment. Ship to independent calibration laboratory: Longer down-time and limited service 3rd party calibration labs do not offer upgrade, adjustment or repair services that may be needed to complete the calibration service. This means additional time and cost to ship the equipment back to the manufacturer for service, and to perform a second calibration. 4

CALIBRATION SERVICE On-site calibration reduces down-time for test equipment. The inconvenience and cost of shipping large devices can be avoided by taking advantage of Teseq s on-site calibration service. In addition to normal RF and power line EMC instrumentation, Teseq routinely performs on-site calibration for anechoic test chambers and open area test sites (OATS). Teseq provides worldwide on-site calibration for Anechoic test chambers Open area test sites (OATS) Shielding effectiveness Site surveys Power line EMC instrumentation RF instrumentation Harmonics & Flicker Transients Additional Teseq calibration service benefits: Detailed calibration (more measuring points) Exhaustive certification process Concurrent repairs and upgrades as needed Free firmware/updates for many products EMC calibration service for all manufacturers equipment 5

ACCREDITED CALIBRATION Teseq Accredited Calibration = Global Competence Teseq s accredited calibration service is primarily suited to the needs of commercial test laboratories and manufacturers with accredited calibration requirements. Accreditation is conferred on test laboratories by numerous agencies worldwide. Teseq laboratories have obtained accreditation from DAkkS (Germany), SAS (Switzerland), UKAS (United Kingdom) and A2LA (USA, Singapore and Japan). Since the International Laboratory Accreditation Cooperation (ILAC) has developed a Mutual Recognition Agreement (MRA) for international cooperation between agencies to promote the acceptance of accredited test and calibration results around the globe, Teseq can provide accredited calibrations for test equipment on worldwide basis. Teseq s test laboratories are accredited in accordance with EN ISO/IEC 17025, which requires technical personnel with specific skills and experience, merged with a technically sophisticated and modern infrastructure, in a quality-driven organization. DAkkS Germany DAkkS Deutsche Akkreditierungsstelle D-K-15033-01-00 www.dakks.de SCS Switzerland Swiss Calibration Service SCS 056 www.seco.admin.ch/sas UKAS United Kingdom Accreditation Service 0445/0392 www.ukas.com A2LA USA American Association for Laboratory Accreditation 2273.01 www.a2la.org A2LA Singapore American Association for Laboratory Accreditation 2939.01 www.a2la.org A2LA Japan American Association for Laboratory Accreditation 2127.03 www.a2la.org 6

TRACEABLE CALIBRATION Teseq Traceable Calibration = Customer Confidence Teseq s traceable calibration service is ideal for all types of commercial and in-house test laboratories. Our traceable calibration procedure is based on the same calibration equipment, procedures, measurement uncertainties and personnel which have been assessed by national accreditation authorities to ensure measurement accuracy and quality. This means that Teseq customers receive accurate, cost-effective service in situations where accreditation is not required. Our traceable calibration procedures follow the requirements of EN ISO/IEC 17025 and ISO 9000, making our service superior to the typical calibration services of other laboratories. 7

Calibration and repair capabilities Teseq s extensive calibration and repair capability encompasses all common and specialized EMC test equipment from any manufacturer, from simple instruments and accessories to the most sophisticated test sites. Product Specification Range Standards ESD simulators ESD 30 kv / 140 A iec 61000-4-2, ISO 10605 Pulse generators Fast transients 8 kv iec 61000-4-4 combination wave surge 10 kv / 5 ka iec 61000-4-5, ANSI C62.41 Ring wave surge 10 kv / 5 ka iec 61000-4-12, ANSI C62.41 telecom surge 10 kv / 5 ka ccitt, ITU, FCC to manufacturers specs mains drop-out 700 V / 500 A IEC 61000-4-11, IEC 61000-4-29, IEC 61000-4-34 Automotive pulse Fast transients 1500 V iso 7637, SAE, JASO, generators Company standards Microsecond pulses 1000 V Load dumps Battery power quality 1000 V 100 V / 300 A / 10 MHz Harmonics and flicker Mains harmonics and IEC 61000-4-7, IEC 61000-3-2, flicker emission iec 61000-3-3, IEC 61000-3-11, measurement, mains IEC 61000-3-12 power variation immunity tests Receivers and analyzers Measuring receivers cispr 16-1-1 click analyzers cispr 16-1-1, CISPR 14-1 Sinus wave generators, 10 khz to 400 MHz ISO 11452, MIL 461, Immunity test systems power meters, 150 khz to 230 MHz IEC 61000-4-3, directional couplers 80 MHz to 1 (6) GHz IEC 61000-4-6 8

Product Specification Range Standards Power amplifier Low, medium, up to 1 kw high RF power up to 6 GHz Antennas BiLog/X-wing (compact) 20 MHz to 3 GHz BiLog Biconical 20 MHz to 1 GHz dipole 30 to 100 MHz EN 50147-2, ANSI C63.4, en 55022, cispr 16-1-4 (CISPR 16-1-6), VCCI:V-3 Loops (active & passive) 9 khz to 30 MHz a reference loop antenna Broadband horns up to 18 GHz Rod 9 khz to 30 MHz Probes and clamps Current sensing/injection 10 khz to 400 MHz MIL 461, CISPR 16-1-2 capacitive voltage 150 khz to 30 MHz CISPR 16-1-2 near field probes 9 khz to 1 GHz Manufacturers specs Absorbing clamps 30 MHz to 1 GHz CISPR 16-1-3, CISPR 16-1-4 EM clamps 10 khz to 1 GHz IEC 61000-4-6 Networks Coupling/decoupling 10 khz to 300 MHz IEC 61000-4-6, CISPR 15 networks (CDN) impedance stabilization 150 khz to 30 MHz CISPR 22, CISPR 16-1-2 networks (ISN) Line impedance 9 khz to 30 MHz CISPR 16-1-2 stabilization networks (LISN) TEM cells GTEM cells IEC 61000-4-20, DTEM cells to manufacturers specs Strip line Chamber calibration Normalized site 30 to 1000 MHz ANSI C63.4, EN 50147-2 services attenuation (NSA) OATS 30 to 1000 MHz ANSI C63.4, CISPR 16 field uniformity iec 61000-4-3 + Amd 1, en 61000-4-3 + Amd 1, BS EN 61000-4-3 Shielding effectiveness Electromagnetic site surveys Reverberation chambers Chamber Calibration SVSWR 1 to 18 GHz cispr 16-1-4 9

Scope of Calibration Teseq AG Switzerland Teseq GmbH Germany Teseq Ltd. UK Teseq Inc. USA Teseq Pte Ltd. Singapore Teseq K.K. Japan Teseq Company Limited China SAS accreditation EN ISO/IEC 17025 Traceable DKD accreditation EN ISO/IEC 17025 Traceable UKAS accreditation EN ISO/IEC 17025 Traceable A2LA accreditation EN ISO/IEC 17025 Traceable A2LA accreditation EN ISO/IEC 17025 Traceable A2LA accreditation EN ISO/IEC 17025 Traceable Traceable ESD pulses, e.g. IEC 61000-4-2/ISO 10605 to 30 kv Burst pulses, e.g. IEC 61000-4-4 to 8 kv Surge pulses, e.g. IEC 61000-4-5 to 10 kv Power magnetic field, e.g. IEC 61000-4-8 Mains drop-outs and dips, e.g. IEC 61000-4-11 Ring wave pulses, e.g. IEC 61000-4-12 Conducted coupling and decoupling networks Mains drop-outs and dips, DC IEC 61000-4-29 Automotive pulse generators RF Power amplifiers Electric field strength 10 khz to 8 GHz Field strength probes DC to 18 GHz EMI measuring receivers TEM wave guides (e.g. GTEM cells) IEC 61000-4-20 Chambers RF Coupling and decoupling networks (LISNs, ISNs, CDNs, clamps) Current clamps Directional couplers RF probes, RF pre-amplifiers and attenuators RF power meters RF generators Antennas LVD testers Harmonics and flicker On-site conducted EMC calibration 10

TESEQ S CUSTOMER SUPPORT TEAMS Our enthusiastic customer support teams are there for you around the clock, dedicated to get your requests done on time, anywhere, anytime! SWITZERLAND Teseq AG Nordstrasse 11F 4542 Luterbach conducted_support@teseq.com Phone +41 32 681 40 40 JAPAN Teseq K.K. Nagoya Office 1-329 Kifune Meito-Ku 465-0058 Nagoya-City NagoyaSupport@teseq.com Phone +81 52 709 5501 11

Customer support teams USA Teseq Inc. 52 Mayfield Avenue Edison, New Jersey 08847 usasales@teseq.com Phone +1 888 417 0501 SINGAPORE Teseq Pte Ltd. Blk 3015A Ubi Road 1 05-09 Kampong Ubi Industrial Estate Singapore 408 705 singaporesales@teseq.com Phone +65 6846 2488 12

The Teseq Human Touch is probably the most valuable favor we can do for our clients. We care personally for your work and we stand fully engaged to support your needs and wants. Whenever, wherever. GERMANY Teseq GmbH Landsberger Strasse 255 12623 Berlin desales@teseq.com Phone +49 30 56 59 8835 UK Teseq Ltd. 5 Ashville Way Molly Millars Lane Wokingham, Berkshire RG41 2PL uksales@teseq.com Phone +44 845 074 0660 13

CHINA Teseq Company Limited Room 1001 - Sky Plaza No. 46 Dongzhimenwai Dajie 100027 Beijing chinasales@teseq.com Phone +86 10 8460 8080 TAIWAN Teseq (Taiwan) Ltd. 3F.-2, No. 92, Baozhong Rd Xindian Dist. New Taipei City 231 taiwansales@teseq.com Phone +886 2 2917 8080 14

A FULL RANGE OF EMC SERVICES With more than 40 years of experience, Teseq has the resources to address any type of EMC challenge. Our extensive range of services and skills can be tailored to meet your specific needs. Consultation and training. Our experts can provide support to a new lab, to expand it for additional tests or to strengthen your staff s knowledge. EMC consultation Training courses and seminars EMC training is available on request in our labs or on-site. Software and automation. Teseq s Compliance 5 lab automation software can easily be customized to your processes for higher efficiency and throughput in your lab. Test methodology advice Test automation software development Fast and easy customization Maintenance contracts System integration. We design and build turn-key EMC systems to precisely fit your test requirements, budget and time frame. EMC system specification EMC system design and implementation services EMC system installation and training EMC system upgrades

EMC instrumentation and systems to suit any budget Teseq offers the world s most comprehensive range of EMC systems for immunity and emissions testing. We take great pride in our world-class research and development program, backed by state-of-the-art global manufacturing. Our membership in the relevant international committees demonstrates our commitment to the industry. Our network of agents and distributors offers market leading EMC expertise tailored to local needs in more than 30 different countries. Our unique modular approach to EMC is focused on our customers business needs. By breaking down the barriers between traditionally separate test functions we can optimize the test process to help you bring products to market more quickly. Headquarters Teseq AG 4542 Luterbach Switzerland T +41 32 681 40 40 F +41 32 681 40 48 sales@teseq.com www.teseq.com China Teseq Company Limited T +86 10 8460 8080 F +86 10 8460 8078 chinasales@teseq.com Singapore Teseq Pte Ltd. T +65 6846 2488 F +65 6841 4282 singaporesales@teseq.com France Teseq Sarl T +33 1 39 47 42 21 F +33 1 39 47 40 92 francesales@teseq.com Switzerland Teseq AG T +41 32 681 40 50 F +41 32 681 40 48 sales@teseq.com Germany Teseq GmbH T +49 30 5659 8815 F +49 30 5659 8811 desales@teseq.com Taiwan Teseq (Taiwan) Ltd. T +886 2 2917 8080 F +886 2 2917 2626 taiwansales@teseq.com Japan Teseq K.K. T +81 3 5725 9460 F +81 3 5725 9461 japansales@teseq.com UK Teseq Ltd. T +44 845 074 0660 F +44 845 074 0656 uksales@teseq.com USA Teseq Inc. T +1 732 417 0501 F +1 732 417 0511 Toll free +1 888 417 0501 usasales@teseq.com To find your local partner within Teseq s global network, please go to www.teseq.com 691-022C May 2012 2012 Teseq Specifications subject to change without notice. Teseq is an ISO-registered company. Its products are designed and manufactured under the strict quality and environmental requirements of the ISO 9001. This document has been carefully checked. However, Teseq does not assume any liability for errors or inaccuries.