Measuring the cover and shade protection factors of synthetic shadecloth

Similar documents
Measuring optical filters

Measuring photometric accuracy using the double aperture method

INDIUM SENSOR. Type X.5 Series

Measuring the reflectance of very small samples using the Agilent Cary 60 Remote Diffuse Reflectance Accessory (DRA)

Measurement Method of High Absorbance (Low Transmittance) Samples by UH4150 INTRODUCTION

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

Crizal UV: the new anti-reflection lens that protects against UV radiation

UV RADIATION AND LIGHT

Film Holder Accessories

Automated Double Aperture Accessory

The importance of the sun The damaging effects of the sun What ultraviolet rays and the UV Index are The SunSense Guidelines

Unique Scattering Measurements Using the Agilent Universal Measurement Accessory (UMA)

Solar Matters I Teacher Page

Automotive Window Film Selector Guide LX Series

UV-A, UV-B & UV-I Sensors

Colours Learning Outcomes

Colours Learning Outcomes. Colours Learning Outcomes. Electromagnetic Spectrum

METAL HALIDE LAMPS FEATURES AND BENEFITS APPLICATIONS AQUALITE METAL HALIDE LAMPS FOR MARINE AQUARIUMS AND REEF SYSTEMS

FULLY REFLECTIVE SOLAR SIMULATORS SS0.5K / SS1.0K / SS1.6K / SS2.5K

ISO Determination of sunscreen UVA photoprotection in vitro. Détermination in vitro de la photoprotection UVA. First edition

Electromagnetic Waves

Experiment E-6 Rayleigh Scattering

Photo-Documentation of Ultraviolet Radiation Induced Visible Fluorescence on Daguerreotypes

Solar protection Effect of selected fabric and use characteristics on UV transmission

Ground-Based Solar UV Radiation Monitoring Technique Using Photocell. Pulchowk Campus, Institute of Engineering, Tribhuvan University, Nepal

Note 2 Electromagnetic waves N2/EMWAVES/PHY/XII/CHS2012

UV-Index Photodiodes Data Sheets

As the Sun Burns. Supplemental science materials. for grades 2-4

Application Note 26. Optical Hazard Measurements with JETI specbos 1211UV

A stray light corrected array spectroradiometer for complex high dynamic range measurements in the UV spectral range.

improved stability (compared with

The prevention of actinic damage has become

Ultraviolet (UV-Index) TOCON Datasheets

KODAK PROFESSIONAL ELITE Chrome 200 Film

Automated Spectrophotometric Spatial Profiling of Coated Optical Wafers

Understanding Absorptive Lenses. What is Light? Light and Sight. Wave Theory 1/14/2013. Ed De Gennaro Richmond, Virginia

Extensions in pen ink dosimetry:

UPK Series - Precision Integrating Spheres with Synthetic ODM98 Coating

Horticultural Lighting Test Report

Problems in Color Proofing from the Colorimetric Point of View

UV-Index Photodiodes Data Sheets

SCREEN 15 + SunSense. 4 to 6. Grades. The SunSense Program is created and distributed by:

KODAK EKTACHROME 160T Professional Film / EPT

KODAK EKTACHROME 100 Plus Professional Film

INVESTIGATION INTO THE UV-PROTECTION OF WOVEN FABRICS COMPOSED OF METALLIC WEFT YARNS

This is the author s version of a work that was submitted/accepted for publication in the following source:

polarized collection version 17.1

Bandpass Interference Filters

ELITE Chrome 100 Film

This document is a preview generated by EVS

transmission and reflection characteristics across the spectrum. 4. Neutral density

INSTRUCTION MANUAL UV RADIOMETERS

From consumer s point of view: Consumers have become very demanding. They want best quality lenses. At best prices. Vision Rx Lab

Mathematical Model of Optimally Designed Sun Protective Workwear Fabric

BEAUTIFUL WORLD: NATURAL COLOUR ENHANCEMENT UNMATCHED CLARITY OF VISION SAFER WORLD: ELIMINATES BOTHERSOME GLARE 100% UVA/UVB PROTECTION EXPERIENCE

Window component characteristics

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Photosynthetically Active Radiation (PAR) Smart Sensor (Part # S-LIA-M003)

High quality Full Sale or Return 7 Price points, RRPs ranging from lines and 3 styles; Classic, Sporty and Trendy

PURAVIS. Eco-friendly glass optical fibers

WAVES & EM SPECTRUM. Chapters 10 & 15

Operation Instructions

AQUALITE METAL HALIDE

Broadbandradiometer specbos 1211

Agilent Cary 7000 Universal Measurement Spectrophotometer ADVANCE YOUR MATERIALS

KODAK EKTACHROME 64 Professional Film

\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Transilluminators: UV light, White light (WE-LED), Blue Light (BE-LED) Made in Germany Made by Herolab NEW

UV-Vis-NIR Spectrophotometer Quick Start Guide

The Architectural Range

ELITE Chrome 400 Film

Promoting UV Exposure Awareness with Persuasive, Wearable Technologies

Optical brighteners: From delight to dismay

MagicReflex. MagicReflex. Original Hanau SunCare. More Power and Life for Your Solaria. MagicReflex UV-Technology

High Performance Thin Film Optical Coatings Technical Reference Document 09/13. Coatings Capabilities. Heat Control - Hot Mirror Filters

LEE Filters. The Architectural Series

polarized collection version 17.1

AMIRAN the glass you can t see

2010 Callaway sunwear 2010 Callaway EYEWEAR (2)

REPORT OF CALIBRATION of One Standard of Spectral Irradiance ( nm)

Multi-Lamp Microwave UV Systems Physics and Technology

REVISITING POTENTIAL HAZARD OF LED SOURCES TO CAUSE BLH IN SPECIFIC POPULATION

Light, Color, Spectra 05/30/2006. Lecture 17 1

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Transitions Lenses & Harmful Blue Light

Uses of Electromagnetic Waves

KODAK EKTACHROME 64T Professional Film

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

LP PHOT 03 LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03

Digital Photography: Fundamentals of Light, Color, & Exposure Part II Michael J. Glagola - December 9, 2006

Section Electromagnetic Waves and the Electromagnetic Spectrum

Spectro UV-VIS Double Beam Research Spectrophotometer UV-VIS Double Beam

WhiteOptics Reflector based on a highly reflective plastic substrate.

Light has some interesting properties, many of which are used in medicine:

Influence of the light spectral distribution used in the radiometers calibration

KODAK EKTACHROME 64 Professional Film

MK350 Portable Spectrometer

Comparison of Quantum Sensors with Different Spectral Sensitivities

Innovative optical solutions. Inspector M2 Manual

Transcription:

Measuring the cover and shade protection factors of synthetic shadecloth Application Note Author Zafira Bilimis Agilent Technologies, Inc. Mulgrave, Victoria 3170, Australia Introduction The ozone layer acts as a filter for dangerous ultraviolet radiation (UVR) from the sun, reducing its impact at the earth's surface. As this ozone layer thins, the effectiveness of this filter is reduced significantly, resulting in skin cancer (e.g. Melanoma), whose incidence increases around the world. The UVR exposures of the population could be significantly reduced by implementing behavioural changes, such as using hats and sunglasses along with protective clothing and shade. Traditionally, shadecloth has been used in the nursery and horticultural industries to provide optimum growing conditions for a variety of plants. In recent years, due to the severe problems associated with the depletion of the ozone layer, shadecloth is being widely used as an architectural medium providing cool shaded outdoor spaces 1. Some examples of the use of shadecloth are: Horticultural shadehouses Fern gardens (ferneries) Livestock protection Shade structures at public swimming pools Shade structures in parks and gardens This paper focuses on how to assess the amount of UVR protection provided by synthetic shadecloth. The cover and shade protection of two shadecloth samples with variable construction (woven and knitted) were determined using a spectrophotometric method.

Equipment Cary 1/3E UV-Vis Spectrophotometer Labsphere DRA-CA-30 Diffuse Reflectance Accessory Schott UG 11 filter Easy Menu software package Results and discussion Method for the determination of the Cover Factor of shadecloth. This method requires five pieces of each shadecloth sample to be cut from the sample roll and tested according to the following procedure 2. 1. Insert UG 11 filter in sample slot and zero the instrument. 2. Insert the shadecloth and UG 11 filter in the sample slot. Note: Ensure that the shadecloth is fixed closely against a UG 11 filter which is fixed very closely to the entrance port of the sphere. The light from the instrument is firstly transmitted through the shadecloth, then through the UG 11 filter and into the integrating sphere. This arrangement ensures the elimination of the effects of fluorescence from the fluorescent whitening agents (FWAs) that may be present in the shadecloth. 3. Record the reading at 350 nm. 4. Repeat (1) to (3), having rotated the sample 90 before insertion into the sample slot. 5. Repeat steps (1) to (4) for the remaining four samples. The cover factor for each of the shadecloth samples was calculated according to the following formula: Cover factor = 100 - %Tav Where %Tav is the average of the 10 readings measured as described in the above procedure. The Australian standard for synthetic shadecloth (AS4174-1994), also requires: The designation of the shadecloth according to the calculated cover factor, (see Table 1). Note: The cover factor ranges displayed in Table 1 are not continuous. This means that any shadecloth which has a cover factor outside of these ranges does not comply with the Australian standard for synthetic shadecloth (AS 4174-1994). A trim colored according to the designation color code shown in Table 1 shall be knitted, woven or attached to the edge of the shadecloth. Table 1. Designation and color code according to cover factor range Type of Designation of Cover Factor Range Color Code Knitted Extra-light 26-34 Dark Green Light 50-56 Red/Orange Medium 64-70 Blue Heavy 74-80 White Extra-heavy 84-90 Lime Green Woven Extra-light 25-30 Dark Green Light 50-55 Red/Orange Medium 67-73 Blue Heavy 77-83 White Extra-heavy 87-93 Lime Green The Easy menu software enables all the measurements and calculations to be performed automatically. This software also allows one to use a standard woven stainless steel mesh (e.g. BS410 British Standard Sieve) of known cover protection factor (CPF) rating to ensure validation of the shadecloth apparatus. Also, there is an instrument test option which allows the operator to validate the wavelength accuracy of the UV-VIS spectrophotometer. 2

Table 2 summarizes the results for the two shadecloth samples which were measured. Table 2. measurement results details Green woven White knitted %T AV Cover Factor (%T) Designation of 12.7 87.3 Extra-heavy Lime Color Code 48.7 51.3 Light Red or Orange Figure 1 shows an example of a report generated by the Easy Menu software package for the cover factor calculations. Sample Name : Shade Cloth 1 Operator Client Batch : 92678 Comment : Zafira Bilimis Type : Woven : Agilent Technologies Australia : Green shadecloth Date : 8 July 1994 Instrument Wavelength Pass Reading 1 (%T) : Cary UV-Vis : 350.00 nm Reading 2 (%T) Average (%T) 1 13.45 13.14 13.30 2 12.64 14.63 13.64 3 14.93 11.69 13.31 4 11.64 12.04 11.84 5 11.03 11.81 11.42 %Tav (350 nm) = 12.70 %T Cover factor = 100 - %Tave = 87.30 %T Designation of shade cloth: Extra Heavy A Lime green trim should be knitted, woven or attached to the edge of the shadecloth. Reference: AS 4174 Figure 1. Report generated by Easy Menu software package Method for the determination of the UV-Visible transmission of shadecloth. This test requires that 10 pieces of shadecloth are cut from the sample roll and tested according to the following procedure 3 : 1. Mount the sample at the sample port of the sphere. 2. Record the UV-Vis transmission of the sample from 290 to 770 nm. 3. Repeat steps (1) and (2) for each of the remaining 9 samples. The shadecloth Easy menu software performs the following calculations automatically: a. The 10 readings which are collected are averaged (%Tav). b. The shade factor is calculated using the following formula: Shade Factor = 100 - %Tav Note: %Tav is the average of the 10 readings over the wavelength range 290 to 770 nm. c. Using the average transmission data from (a) the following parameters are calculated: i. Average % UVR transmission data from 290 to 400 nm %UVR block = 100 - % UVRav. ii. Average % Photosynthetically Active Radiation (PAR) transmission from 400 to 700 nm. Ultraviolet radiation can produce biological damage such as sunburn, hence an accurate assessment of the amount of protection provided by various shadecloth requires the calculation of the %UVR block over the wavelength range 290 to 400 nm, (or 280-390 nm) which includes both the UVB (280 to 315 nm) and the UVA (315-380 nm) regions. This calculation is specifically important when the shadecloth is used as an architectural medium, providing shaded outdoor spaces. 3

For horticultural use, a certain amount of PAR must reach the plants to provide optimum growing conditions. The %PAR transmission calculated over the wavelength range 400 to 700 nm indicates the effectiveness of the shadecloth for the horticultural industry. Table 3 summarizes the results for the two shadecloth samples which were measured using the method described in Appendix B of the Australian standard for synthetic shadecloth. Table 3. Results of shadecloth sample measurements Details Green woven White knitted %T AV 290-770 Shade Factor % PARav 400-700 %T UVRav 290-400 %T UVR Block 16.54 83.46 18.09 11.33 88.67 58.88 41.12 62.62 48.71 51.29 Figure 2 shows an example of a report generated by the Easy Menu software package for the transmission of shadecloth calculations. Sample name : Shade Cloth 1 Operator Client Batch # : 92678 Comment : Zafira Bilimis : Agilent Technologies : Green shadecloth Date : 8 July 1994 Instrument Wavelength range SBW Scan Speed Number of scans : 10 : Cary UV-Vis : 290.00-770.00 nm : 4.0 nm : 900.000 nm/min %Tav (290-770 nm) = 16.54 %T Shade factor = 100 - %Tave = 83.46 %T %PARav (400-700 nm) = 18.09 %T %UVRav (290-400 nm) = 11.33 %T %UVR block Reference: AS 4174 = 100 - %UVRav = 88.67 %T Figure 2. Report generated by Easy Menu software package The Easy Menu displays the wavelength scans, as the shadecloth is being measured, and allows the operator to obtain a printout of the graphics at the end of the run. Figure 3 shows the spectral transmittance of the white and green shadecloth samples. Figure 3. The spectral transmittance of white and green shadecloth samples Conclusion The Cary 1E spectrophotometer, in conjunction with the Labsphere DRA-CA-30 and the Easy Menu software, provides users with a user friendly, highly productive solution. This shadecloth analyzer enables the most novice user to perform shadecloth measurements because the Easy menu software automatically performs all calculations. 4

Acknowledgements Agilent would like to thank Dr Michael Pailthorpe, Professor, Department of Textile Technology, University of New South Wales for his ongoing support in the area of shadecloth protection. References 1. Pailthorpe, M.T. and Auer, P.D., 1991, On the %UV shade provided by shade cloth, Australasian Textiles, 11(6):35. 2. Australian standard for synthetic shadecloth (AS 4174-1994), Appendix A. 3. Australian standard for synthetic shadecloth (AS 4174-1994), Appendix B. 5

www.agilent.com/chem Agilent Technologies, Inc., 1994, 2011 Published March, 2011 Publication Number SI-A-1149