COM-POWER OPERATION MANUAL ACS W

Similar documents
100U1000. Features. 100 watts CW 100kHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

Solid State General Communication Power Amplifier

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

150W1000B. Features. 150 watts CW 80MHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

411LA Broadband Power Amplifier

Broadband Power Amplifier

3100LA Broadband Power Amplifier

MTPA Broadband Power Amplifier

A 500 Broadband Power Amplifier

2100L Broadband Power Amplifier

STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

150W Solid State Broadband EMC Benchtop Power Amplifier 6-18GHz. Parameter Min Typ Max Min Typ Max Units

CBA 400M MHZ to 400 MHZ

1140LA Broadband Power Amplifier

OM1006 Solid State 50 MHz Power Amplifier

Solid State Broadband High Power Amplifier

BROADBAND PREAMPLIFIER MODEL BPA khz 1 GHz

Parameter Min. Typ. Max. Units. Frequency Range 8-11 GHz. Saturated Output Power (Psat) 52 dbm. Input Max Power (No Damage) Psat Gain dbm

Technical Datasheet GT-1000B Microwave Power Amplifier. 100 MHz to 20 GHz. Broadband High-Power Instrumentation Amplifier Rev.

FS-7006PA FS-7012PA YA-7000 POWER AMPLIFIERS. AMPLIFIER AUTO SWITCHING MODULE (Optional) OPERATING INSTRUCTIONS

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

Electrical Safety Tester

PI-10 Broadband Power Indicator

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

MC450/MC650 (MC750) OPERATING INSTRUCTIONS

GT-1000A Microwave Power Amplifier 2 GHz to 20 GHz. Broadband High-Power Instrumentation Amplifier. Preliminary Technical Datasheet

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

RF Amplifier Data Sheet. BT00100-AlphaA-CW 10kHz-1MHz 100W. Scientific and Industrial Applications

A 075 Broadband Power Amplifier

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

AVP TO 2600 MHz, 15 WATTS HIGH POWER GaNPak B AMPLIFIER AVP2524 SPECIFICATIONS * INTERMODULATION PERFORMANCE ABSOLUTE MAXIMUM RATINGS AVP2524

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Models 1421 and 1422 User s Manual. Broadband Amplifiers

Signal and Tracking Generator

RF Amplifier Data Sheet. BT02000-AlphaA-100ms 10kHz-3MHz 2kW. Scientific and Industrial Applications

FU-300W TV Transmitter User s Manual

RF Amplifier Data Sheet. BT01000-Gamma 5MHz-400MHz 1kW. Scientific and Industrial Applications

100W Power Amplifier 8GHz~11GHz

2200L Broadband and Power Amplifier

TOA PROFESSIONAL POWER AMP

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

MQH0XX-YYDS3-ZZZ-2S. High Power 2 Channel RF Driver: For 2 Acousto-optic Q-Switches. Description: Key Features: Applications:

PI-150 Broadband Power Indicator

IP Series DUAL POWER AMPLIFIERS

Installation & Service Manual

1040L Broadband Power Amplifier

4W Ultra Wide Band Power Amplifier 0.1GHz~22GHz

Amplifier HF MHz

Instruction Manual OM3500 HF SHORTWAVE POWER AMPLIFIER. OM POWER, s. r. o Bác 126 SLOVAKIA

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

RF Amplifier Data Sheet. BT00500-AlphaSA-CW 0.5MHz-150MHz 500W. Scientific and Industrial Applications

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

2W Ultra Wide Band Power Amplifier 0.2GHz~35GHz. Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Units. Frequency Range

400Amp True RMS AC Clamp Meter + NCV

Revision 1.b Release Date July 29, 2007 This data sheet covers models 4379, 4472 Revision Notes Repl 0.d (Rev p/n 250W, B version of Comb)

Log Periodic Antenna

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

INTRODUCTION STANDARD FEATURES. Option: High ambient temperature operation (up to 60 C) APPLICATION KU-BAND BOOSTER AMPLIFIER

20W Solid State Power Amplifier 26.2GHz~34GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz.

Synthesized Function Generator

PLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

INSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV

USER'S MANUAL DMR-6700

9W Power Amplifier 26.2GHz~34GHz

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Model FM350 FM Broadcast Pallet Amplifier

2 GHz to 6 GHz, 500 W Power Amplifier HMC8113

20W Solid State Power Amplifier 6-18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

Frequency Range: MHz. Efficiency: 80% Temperature Range: -20 to 65 C Max VSWR: 3:1. Class: Supply Voltage: 32.0V

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

DC-20 GHz Distributed Driver Amplifier. Parameter Min Typ Max Min Typ Max Units

No. 1. BROADBAND RF-POWER-AMPLIFIERS 10 khz - 6 GHz. For immunity tests according to IEC, EN, ISO, SAE, MIL

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.

READ THIS BEFORE ATTEMPTING TO COMBINE

OPERATOR S INSTRUCTION MANUAL

TT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-

AOM Driver 2910 Series

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

Parameter Min. Typ. Max. Min. Typ. Max. Units

Specification for Radiated susceptibility Test

1208 P10-VHF-H-20. Frequency Range: MHz. Efficiency: 10% Temperature Range: 0 to 70 C Max VSWR: 5:1. Class: Supply Voltage: 28.

Optical Transmitter RF-T860/24. Installation & Operation Manual. Caution

WARNING: DO NOT PROCEED WITHOUT READING THIS PAGE.

PROFESSIONAL POWER AMP

AMIS250P 250w Power Amplifier. Operating Manual. AMIS250P, 250 Watt Power Amplifier

MICROTUBE 200. OWNER S MANUAL (version 1)

100W Wide Band Power Amplifier 6GHz~18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz Gain db

Manatronics 48V / 300 Amp Load

USER MANUAL. GOLDMUND Metis 5 Analog Integrated Amplifier

200Amp AC Clamp Meter + NCV Model MA250

BTM Series Pulsed RF Power Amplifier Modules. Application Note

Universal/Standard Ku-band 8W BUC MODEL No. NJT8318 series

WARNING: DO NOT PROCEED WITHOUT READING THIS PAGE.

Transcription:

COM-POWER OPERATION MANUAL For the ACS-250-100W 150 khz to 250 MHz 100W Power Amplifier Page 1 of 15 MANUAL_ACS-250-100W Rev. M02.15

Table of Contents Important Safety Precautions.....3 Introduction..5 Product Specifications.....6 Front/Rear Panel.......... 8 Amplifier Operation............10 Page 2 of 15 MANUAL_ACS-250-100W Rev. M02.15

Important Safety Precautions Safety Symbol Guide ATTENTION Refer Manual WARNING High Voltage Do not attempt to disassemble the instrument. Please contact our service department. AC power input should be within the voltage range specified on the rear panel. Please ensure that the correct fuse is installed prior to applying power for the first time. To avoid electrical shock, the power cord protective grounding conductor must be grounded. In order to protect against fire, replace the fuse with the specified type only. Make sure to disconnect the power cord before replacing the fuse. A blown fuse is indicative of a problem with the instrument. The problem must be repaired before replacing the fuse. It is important to always keep the front panel connectors clean. Disconnect the AC power cord from the instrument before cleaning. Use a soft cloth dipped in a solution of mild detergent and water. Do not spray any liquid onto the unit. Do not use any cleaners containing benzene, toluene, xylene, acetone and/or any other harsh chemicals. Page 3 of 15 MANUAL_ACS-250-100W Rev. M02.15

Do not exceed +3 dbm into the RF INPUT. Do not place heavy objects on top of the instrument. Avoid any rough handling that could damage the ACS-250-100W unit. Use electrostatic discharge precautions while handling and making connections to the ACS-250-100W unit. Do not insert wires into the connectors of the ACS-250-100W. Make proper connection with mating connectors and/or adapters. Do not block or obstruct the cooling fan vents located on the top, side and rear side of the unit. Page 4 of 15 MANUAL_ACS-250-100W Rev. M02.15

Introduction The Com-Power model ACS-250-100W broadband power amplifier operates from 150 khz to 250 MHz. This amplifier can be used for EMC immunity testing that requires generating electric fields. This small and lightweight amplifier utilizes class AB linear power devices that provide high gain, and wide dynamic range. By employing advanced components, the Com-Power ACS-250-100W amplifier is able to achieve high efficiency operation and reliability. Page 5 of 15 MANUAL_ACS-250-100W Rev. M02.15

Product Specifications Frequency Range 150 khz - 250 MHz Power Output: Rated Output 100 watts into 2:1 VSWR Power Protection Limit 140 watts Output Power @ 1dB compression No Compression upto 100W Gain 50 db ± 2 db Input for rated output 0 dbm (Typical) Input: Impedance 50 ohms, nominal VSWR 1.7 maximum Modulation on input AM, FM, or pulse modulation Connector Type N-Female (on Front Panel) Output: Impedance 50 ohms, nominal VSWR 1.7 maximum Harmonic distortion 15 dbc (min) at 100 watts Mismatch Tolerance VSWR of 5:1 Connector Type N-Female (on Front Panel) Line Power Single-phase Type: Universal 100-250 Volts ac, 50/60 Hz, 400 VA Power Fuse: 250V, 5 Amps (T) Page 6 of 15 MANUAL_ACS-250-100W Rev. M02.15

Display and Interfaces USB Remote Interface Front panel display Continuous monitoring and display of Temperature, Current, Input / Output Power, VSWR and Gain Mechanical: Cooling Requirement Forced air (self contained fans) Size 19 Rack 4U Weight 21.4 kg (47 lb.) Operating Temperature 0 o C to 50 o C Page 7 of 15 MANUAL_ACS-250-100W Rev. M02.15

Front/Rear Panel Front Panel: 8 3 1 4 8 5 2 6 7 1. RF output ON/OFF switch 2. Indicates RF output is ON when green light is lit 3. LCD display 4. Fault indicators 5. USB interface- for factory programming/maintenance. 6. RF input port- secure all connections required for the 50 ohm system prior to turning on the RF output. Caution: Although it has a auto shutoff in case of input levels above +3 dbm. Application of high power input signal or transients may damage the power amplifier. 7. RF output port- secure all the connections required for the 50 Ohm system prior to turning on the RF output. Page 8 of 15 MANUAL_ACS-250-100W Rev. M02.15

Caution: High power output present at the output port when unit is operating, which could lead to serious injuries to user. Do not touch the connector when the unit is ON. 8. Handles Rear Panel: 10 11 12 10. Mains power input to unit with inbuilt fuse socket. The power input can be between 100V AC to 250VAC,47-63Hz, 400VA. The unit auto detects the power supply voltage. The fuse provides primary AC circuit protection. In case of failure of Fuse, replace only with the rated fuse {5x 20 mm 250 V, 5A, (T)} 11. AC supply power ON switch 12. Serial number of unit. Page 9 of 15 MANUAL_ACS-250-100W Rev. M02.15

Amplifier Operation 1. Before turning on the unit, make sure the RF input and output ports on the front panel are connected to their respective 50Ω input/output devices. 2. Turn on power switch on rear panel. The following messages will be displayed on LCD. Page 10 of 15 MANUAL_ACS-250-100W Rev. M02.15

In normal condition following message will be displayed NOTE: Prior to turning the front panel power switch ON, please ensure that the RF output of the RF signal source connected to the Amplifier input is turned off or below -45 dbm. When the front panel power switch is turned ON, the ACS-250-100W performs a self test. ACS-250-100W does not allow the presence of an input signal greater than -45 dbm during the self test and the presence of an input signal will automatically disable the output and display the following message until RF input is reduced below -45 dbm. Page 11 of 15 MANUAL_ACS-250-100W Rev. M02.15

3. Turn on switch from the front panel as shown in picture. Upon successful completion of the self test mode the LCD screen will display the Driver 1 & 2 Current/Temperature, Module Current/Temperature and System Status. Please note that Pin, Pout, SWR and Gain will not be displayed until the amplifier sees an input of -45dBm. 4. When the RF input is applied (in excess of -40 dbm), the front panel LCD displays the actual measured values for Pin, Pout, SWR, and Gain. The current and temperature status of PA and Driver is always displayed regardless of the input state. Page 12 of 15 MANUAL_ACS-250-100W Rev. M02.15

Displayed indications and their meanings: Driver1 = Driver1 Current/Temperature (Line 1, columns 1/2 on LCD) Driver2 = Driver2 Current/Temperature (Line 2, columns 1/2 on LCD) PA = PA Module Current/Temperature (Line 3, columns 1/2 on LCD) PS = Power Supply status (Line 4 on LCD) Prev = Reflected Power sensed at the RF output (Line 1, column 3 on LCD) Pin = Input Power to the unit (Line 2, column 3 on LCD) Pout = Output Power of the unit (Line 3, column 3 on LCD) Gain = Gain of the unit (Line 4, column 3 on LCD) 5. Before switching off the power from the front panel, make sure the RF output is reduced to a safe level (-50 dbm) or completely disabled. 6. In the event of any fault occurring, the unit will automatically shut down. Page 13 of 15 MANUAL_ACS-250-100W Rev. M02.15

7. Depending on the nature of the fault the appropriate red LED will be light up and the corresponding fault message will be displayed on front panel LCD. 8. In order to restart the unit, first turn off the front panel switch, and then restart the unit as described in Section 3. Page 14 of 15 MANUAL_ACS-250-100W Rev. M02.15

9. Please refer to the Diagnostics chart below to check fault conditions SR.#. FAULT LIGHT LIT MESSAGE ON LCD SCREEN FAULT POSSIBLE CAUSE 1 Current 2 Temperature 3 4 Power Supply RF Input / RF Output 5 VSWR PA CURRENT RANGE EXCEEDED OR DRIVER CURRENT RANGE EXCEEDED PA TEMPERATURE RANGE EXCEEDED OR DRIVER TEMPERATURE RANGE EXCEEDED POWER SUPPLY BAD RF INPUT EXCEEDS +3 dbm OR RF OUTPUT EXCEEDS +48.2 dbm Reflected Power > 85 Watts Indicates that the current through the module exceeds 9.0 Amperes or the driver current exceeds 2.00 Amperes. Indicates that the temperature range of the module or driver has risen higher than 65 C. Indicates that the DC power supply is not working properly. Indicates either input or output power has exceeded internal limit. Indicates that the reflected power to the Power amplifier has exceeded internal limits. * Power limit was exceeded * Mismatch on 50-ohm System * VSWR of the system is too high * Mismatch on 50-ohm system * VSWR of the system is too high * DC power supply failed * AC input zero cross detector failed * Excessive current draw due to device failure. * Input power limit was exceeded. * Output power limit was exceeded. * Check output connection of unit and connected system. Page 15 of 15 MANUAL_ACS-250-100W Rev. M02.15