MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

MY-GS CSM_MY-GS_DS_E_2_1

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

CSM_G7S-_-E_DS_E_7_1

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

Model Number Structure

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

OMRON MK-I / -S RELAY

Model Number Structure

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

General-purpose Relay

Alternate Operation Relay 61F-AN/-APN2

E3X-DRT21/SRT21/CIF11

Model Number Structure

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

General-purpose Relay

Model Number Structure

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

Fluoro plastic housing for highest chemical and detergent resistance

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

SPST-NO SPDT DPST-NO DPDT

Switch Mode Power Supply

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

Details on the New G2RS

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Phase-sequence Phase-loss Relay

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

E8EB-N0C2B E8EB-N0B2B

* (110 VAC) in this catalog have been discontinued at the end of March L 2KM: Long-distance (for 2 km)

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Model Number Structure

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

Model Number Structure

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

E6F-CWZ5C (1000P/R) 2M

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

Single-phase Current Relay

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

Sensing method Sensing distance Model

Floatless Level Switch (Ultra High-sensitivity Type) 61F-UHS/-HSL

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

SPST-NO SPDT DPST-NO DPDT

Model Number Structure

Ordering Information. Ratchet Relay G4Q. Model Number Legend

Classification Enclosure rating Contact form Contact material

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

Single-phase Voltage Relay

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

G5LE. Ordering Information. PCB Relay. A Cubic, Single-pole 10-A Power Relay J MODEL NUMBER LEGEND G5LE PCB Relay G5LE

Model Number Structure

General-purpose Relay

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

G2RL-1A G2RL-1 G2RL-2A G2RL-2

Pre-Filter. Brushless/ Sparkless Blower. HEPA Filter. Fluorescent Light

Switch Mode Power Supply

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Phase-sequence Phase-loss Relay

Contact Ag + Au-clad AgPd + Au-clad. General purpose DPDT G6AU-274P-ST-US G6AU-234P-ST-US 4PDT G6AU-474P-ST-US G6AU-434P-ST-US

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

View Terms and Conditions: Effective 12/5/2015 Effective 6/17/2017

Relays with Forcibly Guided Contacts G7SA

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Signal Isolation Module. Instruction Manual SIM

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

380 SERIES REPAIR PARTS INDEX. NOTE! Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump.

HI-HOLD MODELS AVAILABLE. Electrical All Models T5009 T Contact Configurations: 2 N/C + 1 N/O 2 N/C + 2 N/O, 3 N/C + 1 N/O, 4 N/C

Transcription:

General Purpose Relays MKS Exceptionally Reliable General Purpose Relay now available with Lockable Test Button IEC Rating of A 0 V AC 0/0 Hz, General use 100,000 cycles. Mechanical indicator standard for all models. Optional features include lockable test button, LED indicator, diode surge suppression, varistor, reverse polarity, and alternate wiring styles. UL (RU/ C RU), CE and TUV approved. RoHS Compliant. Features Two-way Action Test Button Relay in Normal Operation For Momentary Operation For Lock Operation Yellow button Pull down the test button to the first position, then press the yellow button with an insulated tool to operate the contact. Pull down the test button to the second position. (The contact is now in the locked position.) Model Number Structure Model Number Legend MKS@@@@@-@-@ 1 1. Contact Form : DPDT : PDT. Terminals P: Plug-in. Mechanical Indicator/Test Button Blank:Mechanical indicator I: Mechanical indicator and lockable test button. LED Indicator Blank: Standard N: LED indicator. Coil Polarity Blank: Standard 1: Reverse polarity (DC coil only). Surge Absorption Blank:Standard D: Surge absorber diode (DC coil only) V: Surge absorber varistor (AC coil only). Internal Connections DPDT Blank: Standard : Non Standard Internal Connections PDT : Standard Blank: Non Standard : Non Standard. Rated Voltage (Refer to Coil Ratings.) General Purpose Relays MKS

Ordering Information List of Models Type Terminals Contact form Internal connections (See note.) Basic Models Models with LED Indicator (See note.) Models with Diode (See note.) Models with LED Indicator and Diode Models with Varistor Models with LED Indicator and Varistor 10A Sockets (Order Separately) With mechanical indicator With mechanical indicator and lockable test button Coil ratings Plug-in DPDT Standard MKSP MKSPI AC/DC Non Standard MKSP- MKSPI- PDT Standard MKSP- MKSPI- Non Standard MKSP- MKSPI- MKSP MKSPI DPDT Standard MKSPN(1) MKSPIN(1) AC/DC Non Standard MKSPN(1)- MKSPIN(1)- PDT Standard MKSPN(1)- MKSPIN(1)- Non Standard MKSPN(1)- MKSPIN(1)- MKSPN(1) MKSPIN(1) DPDT Standard MKSP(1)-D MKSPI(1)-D DC Non Standard MKSP(1)-D- MKSPI(1)-D- PDT Standard MKSP(1)-D- MKSPI(1)-D- Non Standard MKSP(1)-D- MKSPI(1)-D- MKSP(1)-D MKSPI(1)-D DPDT Standard MKSPN-D MKSPIN-D DC Non Standard MKSPN-D- MKSPIN-D- PDT Standard MKSPN-D- MKSPIN-D- Non Standard MKSPN-D- MKSPIN-D- MKSPN-D MKSPIN-D DPDT Standard MKSP-V MKSPI-V AC Non Standard MKSP-V- MKSPI-V- PDT Standard MKSP-V- MKSPI-V- Non Standard MKSP-V- MKSPI-V- MKSP-V MKSPI-V DPDT Standard MKSPN-V MKSPIN-V AC Non Standard MKSPN-V- MKSPIN-V- PDT Standard MKSPN-V- MKSPIN-V- Non Standard MKSPN-V- MKSPIN-V- MKSPN-V MKSPIN-V Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications. Example: MKSP DC Rated voltage. The DC coil comes in two types: standard coil polarity and reverse coil polarity. Refer to Terminal Arrangement and Internal Connections. Example: MKSPN1- DC Reverse coil polarity. Refer to Terminal Arrangement and Internal Connections for all wiring diagrams. Item Type Model Track-mounted -pin PF0A-E Socket 11-pin PF11A-E -pin PF0A-D 11-pin PF11A-D Hold-down Clip PFC-A1 (For PF0A-E and PF11A-E) General Purpose Relays MKS

Specifications Ratings Coil Ratings Rated voltage Rated current Coil resistance Must operate Must release 0 Hz 0 Hz voltage voltage AC V ma ma.1 Ω 0% max. of rated 0% min. of rated 1 V 1 ma 1 ma 1. Ω voltage voltage at 0 Hz % min. of rated V 110 ma. ma. Ω voltage at 0 Hz 110 V. ma 1.0 ma Ω 10 V. ma 1. ma 1,10 Ω 0 V 1.1 ma 10. ma,0 Ω 0 V 11. ma 10.0 ma,0 Ω 0 V 11.0 ma. ma,0 Ω DC V ma. Ω 1% min. of rated 1 V 11 ma 10 Ω voltage V. ma 0 Ω V.1 ma 1,10 Ω 100 V 1. ma,0 Ω 110 V 1. ma,0 Ω Note: 1. The rated current and coil resistance are measured at a coil temperature of C with tolerances of +1%/ 0% for AC rated current and ±1% for DC coil resistance.. Performance characteristic data are measured at a coil temperature of C.. The maximum voltage is one that is applicable instantaneously to the Relay coil at C and not continuously.. For DC-operated Relays with the LED indicator built-in, add an LED current of approx. ma to the rated current. Contact Ratings Max. voltage 110% of rated voltage Power consumption Approx.. VA at 0 Hz Approx.. VA at 0 Hz Approx. 1. W Load Resistive load (cosφ = 1) Contact mechanism Single Contact material AgSnIn Rated load NO 10 A, 0 VAC 10A, 0 VDC NC A, 0 VAC A, 0 VDC Rated carry current 10 A Max. switching voltage 0 VAC, 0 VDC Max. switching current 10 A Max. switching capacity NO,00 VA/00 W NC 1,0 VA/10 W Inductive load (p.f. = 0.) A, 0 VAC General Purpose Relays MKS

Characteristics Contact resistance Operate time Release time Max. operating frequency Insulation resistance Dielectric strength Insulation method Impulse withstand voltage Note: 1. The values given above are initial values.. Ambient temperature of models with LED indicator is to 0 C. Approved Standards UL Recognized (File No. E11) - - Ambient Temp. = 0 C Note: 10A UL ratings are with no load on the other contact set. CSA Certified by Engineering Data Reference Data Maximum Switching Power 100 mω max. AC: 0 ms max. DC: 0 ms max. 0 ms max.(0 ms max. for built-in diode models) Mechanical: 1,000 operations/hr (no load) Electrical:1,00 operations/hr (at rated load) 100 MΩ min. (at 00 VDC),00 VAC 0/0 Hz for 1 min. between coil and contacts 1,000 VAC 0/0 Hz for 1 min. between contacts of same polarity and terminals of the same polarity,00 VAC 0/0 Hz for 1 min. between current-carrying parts, non-current-carrying parts, and opposite polarity Basic insulation. kv between coil and contacts (with 1. 0 μs impulse wave).0 kv between contacts of different polarity (with 1. 0 μs impulse wave) Pollution degree Rated insulation voltage 0 V Vibration resistance Destruction:10 to Hz, 1. mm double amplitude Malfunction:10 to Hz, 1.0 mm double amplitude Shock resistance Destruction:1,000 m/s (approx. 100 G) Malfunction:100 m/s (approx. 10 G) Life expectancy Mechanical:,000,000 operations min. Electrical:100,000 operations min. Min. permissible load 10 ma at 1 VDC P level: λ 0 =0.1 x 10 - / ops Ambient temperature Operating: 0 to 0 C (with no icing or condensation) Ambient humidity Operating: % to % Weight Approx. 0 g Coil ratings Contact ratings Operations to 110 VDC to 0 VAC N.O. contact N.C. contact Switching current (A) 100 0 0 10 10 A, 0 V AC 0/0 Hz (Resistive) 100,000 10 A, 0 V DC (Resistive) A, 0 V AC 0/0 Hz (General Use) 10 A, 0 V AC 0/0 Hz (Resistive) 100,000 10 A, 0 V DC (Resistive) A, 0 V AC 0/0 Hz (General Use) DC resistive load with NO contact AC resistive load with NO contact IEC Standard/TUV Certification: IEC110-1 (Certification No. R010) Coil ratings Contact ratings Operations, 1,,, 100, 110 VDC, 1,, 100, 110, 00, 0, 0 VAC N.O. contact N.C. contact 10 A, 0 V AC 0/0 Hz (Resistive) 100,000 10 A, 0 V DC (Resistive) A, 0 V AC 0/0 Hz (General Use) A, 0 V AC 0/0 Hz (Resistive) 100,000 A, 0 V DC (Resistive) A, 0 V AC 0/0 Hz (General Use) Note: Maximum carrying current per TUV Certification is A when new MK-S relays are mounted in PF0A-E or PF11A-E Sockets. Rated Carry Current vs. Ambient Rated Temperature Rated carry current (A) 10 UL derating curve DC resistive load with NC contact AC resistive load with NC contact AC inductive load (p.f. = 0.) 1 10 0 0 100 00 00 1.000 Switching voltage (V) 0 0 0 0 0 0 0 0 Ambient temperature ( C) Note: The lower limit of the ambient operating temperature for models with built-in operation indicators is C. 0 General Purpose Relays MKS

Dimensions Note: All units are in millimeters unless otherwise indicated. Models without Test Button Models with Lockable Test Button. max.. max.. max. 0.. max.. max. 0.. max. Track Mounted Sockets See below for Socket dimensions. Poles Finger-protection models Maximum carry current 10 A A poles PF0A-E PF0A-D PF0A poles PF11A-E PF11A-D PF11A Note: If using the PF0A or PF11A Sockets, be sure the maximum carrying current is A or less. When using finger-protection sockets, make sure the connecting wire terminals are Y-shaped. PF0A-E (Conforming to EN 00) Eight, M. sems Terminal Arrangement PF11A-E (Conforming to EN 00) Eleven, M. sems Terminal Arrangement max.. max.. 1 max.. 1 max. Mounting Holes Two, M or two.-dia. holes. max.. 1 max. Mounting Holes Two, M or two.-dia. holes ±0. ±0. General Purpose Relays MKS 1

PF0A-D PF11A-D. Terminal Arrangement 1 1. Terminal Arrangement 1 1 Eight, M screws A 1 1 11 A1 Eight, M screws 10 A 11 1 A1 1 Mounting Holes Two, M or two.-dia. hole Mounting Holes Two, M or two.-dia. hole 0 0 Hold-down Clips PFC-A1 ( pieces per set). 0.. Mounting Tracks PFP-100N, PFP-0N (Conforming to EN 00) PFP-100N (Conforming to EN 00)..±0.1 ±0. ±0.1. ±0. 1. 1 * 10 10 1000 (00)* 1 () 1 1 1 10 10 1000± 1 1. * The figure in parenthesis is for PFP-0N. Mounting Height with Sockets. (See note.) Two poles.. (See note.) Three poles. PF0A(-E) PF11A(-E) Note: PF0A(-E) and PF11A(-E) allow either track or screw mounting. General Purpose Relays MKS

Terminal Arrangement/Internal Connection (Bottom View) Basic Models (AC/DC Coil) MKSP(I) MKSP(I)- MKSP(I) MKSP(I)- MKSP(I)- 1 1 LED Indicator Type (AC Coil) MKSP(I)N MKSP(I)N- MKSP(I)N MKSP(I)N- MKSP(I)N- 1 1 LED Indicator Type (DC Coil: Standard Polarity) MKSP(I)N MKSP(I)N- MKSP(I)N MKSP(I)N- MKSP(I)N- 1 1 LED Indicator Type (DC Coil: Reverse Polarity) MKSP(I)N1 MKSP(I)N1- MKSP(I)N1 MKSP(I)N1- MKSP(I)N1-1 1 Diode Type (DC Coil: Standard Polarity) MKSP(I)-D MKSP(I)-D- MKSP(I)-D MKSP(I)-D- MKSP(I)-D- 1 1 Diode Type (DC Coil: Reverse Polarity) MKSP(I)1-D MKSP(I)1-D- MKSP(I)1-D MKSP(I)1-D- MKSP(I)1-D- 1 1 General Purpose Relays MKS

LED Indicator and Diode Type (DC Coil) MKSP(I)N-D MKSP(I)N-D- MKSP(I)N-D MKSP(I)N-D- MKSP(I)N-D- 1 1 Varistor Type (AC Coil) MKSP(I)-V MKSP(I)-V- MKSP(I)-V MKSP(I)-V- MKSP(I)-V- 1 1 LED Indicator and Varistor Type (AC Coil) MKSP(I)N-V MKSP(I)N-V- MKSP(I)N-V MKSP(I)N-V- MKSP(I)N-V- 1 1 Safety Precautions Safety Precautions for Correct Use Installation Recommend mounting MK-S Relay so that side with wiring diagram is facing down. Handling Check coil polarity when wiring LED Indicator and Diode Models. Test Button Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely. Check that the test button is released before turning ON relay circuits. If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. Use an insulated tool when you operate the test button. Models with test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the Relay is in a complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only the requirements for basic insulation are fulfilled. General Purpose Relays MKS

Omron Electronic Components, LLC Terms and Conditions of Sales I. GENERAL 1. Definitions: The words used herein are defined as follows. (a) Terms: These terms and conditions (b) Seller: Omron Electronic Components LLC and its subsidiaries (c) Buyer: The buyer of Products, including any end user in section III through VI (d) Products: Products and/or services of Seller (e) Including: Including without limitation. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments, invoices, purchase orders and other documents, whether electronic or in writing, relating to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms.. Distributor: Any distributor shall inform its customer of the contents after and including section III of these Terms. II. SALES 1. Prices; Payment: All prices stated are current, subject to change without notice by Seller. Buyer agrees to pay the price in effect at the time the purchase order is accepted by Seller. Payments for Products received are due net 0 days unless otherwise stated in the invoice. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice.. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past due amounts owing to Seller.. Interest: Seller, at its option, may charge Buyer 1.% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms.. Orders: Seller will accept no order less than 00 U.S. dollars net billing.. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer shall make remittance to Seller at the then current exchange rate most favorable to Seller; provided that if remittance is not made when due, Buyer will convert the amount to U.S. dollars at the then current exchange rate most favorable to Seller available during the period between the due date and the date remittance is actually made.. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining any government approvals regarding the importation or sale of the Products.. Taxes: All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Seller or required to be collected directly or indirectly by Seller for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Seller.. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller, Seller reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Seller may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts.. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Seller fully against all costs or expenses arising in connection therewith. 10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller: (a) All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Seller), at which point title to and all risk of loss of the Products shall pass from Seller to Buyer, provided that Seller shall retain a security interest in the Products until the full purchase price is paid by Buyer; (b) Delivery and shipping dates are estimates only; and (c) Seller will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 1. Claims: Any claim by Buyer against Seller for shortage or damage to the Products occurring before delivery to the carrier or any claim related to pricing or other charges must be presented in detail in writing to Seller within 0 days of receipt of shipment. III. PRECAUTIONS 1. Suitability: IT IS THE BUYER S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E) SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT. Buyer acknowledges that it alone has determined that the Products will meet their requirements of the intended use in all cases. Buyer must know and observe all prohibitions of use applicable to the Product/s.. Use with Attention: The followings are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible use of any Product, nor to imply that any use listed may be suitable for any Product: (a) Outdoor use, use involving potential chemical contamination or electrical interference. (b) Use in consumer Products or any use in significant quantities. (c) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (d) Systems, machines, and equipment that could present a risk to life or property.. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY SELLER.. Programmable Products: Seller shall not be responsible for the Buyer's programming of a programmable Product. IV. WARRANTY AND LIMITATION 1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Seller (or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES, NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an amount equal to the purchase price of the Product; provided that there shall be no liability for Seller or its affiliates unless Seller's analysis confirms that the Products were correctly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Seller before shipment.. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF THE PRODUCT ON WHICH LIABILITY IS ASSERTED.. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. V. INFORMATION; ETC. 1. Intellectual Property: The intellectual property embodied in the Products is the exclusive property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way without the written permission of Seller. Buyer (at its own expense) shall indemnify and hold harmless Seller and defend or settle any action brought against Seller to the extent that it is based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party.. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Seller. All information and materials supplied by Seller to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party.. Performance Data: Performance data is provided as a guide in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements.. Change In Specifications: Product specifications and descriptions may be changed at any time based on improvements or other reasons. It is Seller s practice to change part numbers when published ratings or features are changed, or when significant engineering changes are made. However, some specifications of the Product may be changed without any notice.. Errors And Omissions: The information on Seller s website or in other documentation has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses regarding (a) export of the Products or information provided by Seller; (b) sale of Products to forbidden or other proscribed persons or organizations; (c) disclosure to noncitizens of regulated technology or information. VI. MISCELLANEOUS 1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing between Buyer and Seller shall operate as a waiver of rights by Seller.. Assignment: Buyer may not assign its rights hereunder without Seller's written consent.. Law: These Terms are governed by Illinois law (without regard to conflict of laws). Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any dispute hereunder.. Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties.. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. General Purpose Relays MKS

Certain Precautions on Specifications and Use 1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iii) Use in consumer products or any use in significant quantities. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof.. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to Seller's Warranty and Limitations of Liability.. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Seller representative at any time to confirm actual specifications of purchased Product.. Errors and Omissions. The information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions.. RoHS Compliance. Where indicated, our products currently comply, to the best of our knowledge as of the date of this publication, with the requirements of the European Union's Directive on the Restriction of certain Hazardous Substances ("RoHS"), although the requirements of RoHS do not take effect until July 00. These requirements may be subject to change. Please consult our website for current information. Complete Terms and Conditions of Sale for product purchase and use are on Omron s website at http://www.components.omron.com under the About Us tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.0. To convert grams into ounces, multiply by 0.0. OMRON ELECTRONIC COMPONENTS LLC E. Commerce Drive, Suite B Schaumburg, IL 01 -- Cat. No. X01-E-1 0/0 Specifications subject to change without notice OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Printed in USA General Purpose Relays MKS