DUANE-HUNT RELATION AND DETERMINATION OF PLANCK S CONSTANT

Similar documents
Atomic and nuclear physics

Solid-state physics. Bragg reflection: determining the lattice constants of monocrystals. LEYBOLD Physics Leaflets P

Atomic and nuclear physics LD. Fine structure of the characteristic x-radiation of an iron anode. Physics

Instruction sheet

Instruction sheet

Instruction sheet

Experiment #12 X-Ray Diffraction Laboratory

X-ray investigation of crystal structures / Laue method with digital X-ray detector (XRIS) (Item No.: P )

2. Refraction and Reflection

Experimental Competition

Instructions XRD. 1 Choose your setup , Sami Suihkonen. General issues

Spectroscopy Lab 2. Reading Your text books. Look under spectra, spectrometer, diffraction.

Physics 4C Chabot College Scott Hildreth

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: )

Modern Physics Laboratory MP4 Photoelectric Effect

Atomic and Nuclear Physics

EXPERIMENT 3 THE PHOTOELECTRIC EFFECT

Lab 12 Microwave Optics.

AP Chemistry Cell Phone Spectroscopy Lab Adopted from Alexander Scheeline Department of Chemistry University of Illinois at Urbana-Champaign

Test procedures Page: 1 of 5

IBIL setup operation manual for SynerJY software version

MicroLab 500-series Getting Started

3B SCIENTIFIC PHYSICS

Experiment 6: Franck Hertz Experiment v1.3

Physics Laboratory Scattering of Photons from Electrons: Compton Scattering

A PORTABLE X-RAY APPARATUS FOR BOTH STRESS MEASUREMENT AND PHASE ANALYSIS UNDER FIELD CONDITIONS.

Physics 342 Laboratory. Scattering of Photons from Free Electrons: Compton Scattering

Experiment 1: The Wave Model of light vs. the Quantum Model

Educational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539

Ph 3455 The Franck-Hertz Experiment

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES

Scanning Electron Microscope FEI INSPECT F50. Step by step operation manual

Photoelectric effect

FluorCam PAR- Absorptivity Module & NDVI Measurement

Standard Instructions for the Bruker D8 Advance Diffractometer, EPFL Valais Bragg Brentano and GID (Reflection)

ISONIC PA AUT Spiral Scan Inspection of Tubular Parts Operating Manual and Inspection Procedure Rev 1.00 Sonotron NDT

Instructions for Tecnai a brief start up manual

Part 1: Standing Waves - Measuring Wavelengths

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

The Photoelectric Effect

LECTURE 20 ELECTROMAGNETIC WAVES. Instructor: Kazumi Tolich

1 Diffraction of Microwaves

Photoelectric Effect Apparatus

Ph 3455 The Photoelectric Effect

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

Diode Pointer Quick Start Guide

ABM International, Inc.

ANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER

Physics 476LW. Advanced Physics Laboratory - Microwave Optics

Microwave Diffraction and Interference

Thorvie Instructions Always wear eye protection and do not wear loose clothing when operating machinery. FOR AV- 41 ICE AUGER MACHINE

Physics 4C. Chapter 36: Diffraction. Diffraction. Diffraction. Diffraction

Experiment 10. Diffraction and interference of light

OPTICAL BENCH - simple type

(Oct revision) Physics 307 Laboratory Experiment #4 The Photoelectric Eect

TEL-X-Ometer X-Ray System Manual

Service Manual for XLE/XLT Series Laser Engravers

Y11-DR Digital Radiography (DR) Image Quality

WE BRING QUALITY TO LIGHT DTS 500. Positioner Systems AUTOMATED DISPLAY AND LIGHT MEASUREMENT

Microscopy. The dichroic mirror is an important component of the fluorescent scope: it reflects blue light while transmitting green light.

Powder diffractometer operation instructions D8 Advance with a Cu Kα sealed tube and Lynxeye MARCH 30, 2016

Radiation characteristics of a dipole antenna in free space

Reflection Teacher Notes

Renishaw InVia Raman microscope

Diode Pointer Quick Start Guide

General Measurement (BB) Part

Basic Users Manual for Tecnai-F20 TEM

Basic P-XRD instructions for Operating the Instrument

6 Experiment II: Law of Reflection

Written By: Scott Havard

(A) 2f (B) 2 f (C) f ( D) 2 (E) 2

Physics 4BL: Electricity and Magnetism Lab manual. UCLA Department of Physics and Astronomy

Instruction sheet VideoCom Retroreflecting Foil Falling Body for VideoCom. 1 Safety notes

Powder X-Ray Diffraction Alignment Procedure

Alumajust Installation Instructions

Physics 308 Laboratory Experiment F: Grating Spectrometer

The Wave Nature of Light

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

Standard Operating Procedure

Skoog Chapter 1 Introduction

RENISHAW RAMAN MICROSCOPE STANDARD OPERATING PROCEDURE

Guide to SPEX Optical Spectrometer

Single Slit Diffraction

General Physics Laboratory Experiment Report 2nd Semester, Year 2018

Scanning Electron Microscope in Our Facility

Reflection of Light, 8/8/2014, Optics

Operating Manual. Model 721N. Visible Spectrophotometer

Observational Astronomy

JEOL 6500 User Manual

NANO 703-Notes. Chapter 9-The Instrument

EDUCATIONAL SPECTROPHOTOMETER ACCESSORY KIT AND EDUCATIONAL SPECTROPHOTOMETER SYSTEM

3B SCIENTIFIC PHYSICS

MICROWAVE OPTICS. Instruction Manual and Experiment Guide for the PASCO scientific Model WA-9314B G

Experiment 19. Microwave Optics 1

Minnesota Rules, Chapter 4732 X-ray Revision

3B SCIENTIFIC PHYSICS

A PORTABLE X-RAY APPARATUS FOR BOTH STRESS MEASUREMENT AND PHASE ANALYSIS UNDER FIELD CONDITIONS.

Chemistry Instrumental Analysis Lecture 7. Chem 4631

Franck-Hertz Control Unit

Transcription:

DUANE-HUNT RELATION AND DETERMINATION OF PLANCK S CONSTANT OBJECTIVES To determine the limit wavelength min of the bremsstrahlung continuum as a function of the high voltage U of the x-ray tube. To confirm the Duane-Hunt relation. To determine Planck s constant. PRINCIPLES R K K min Fig. 1 Emission spectrum of an x-ray tube with the limit wavelength min of the bremsstrahlung continuum and the characteristic K and K lines. The bremsstrahlung continuum in the emission spectrum of an x-ray tube is characterized by the limit wavelength min (see Fig. 1), which becomes smaller as the tube high voltage increases. In 1915, the American physicists William Duane and Franklin L. Hunt discovered an inverse proportionality between the limit wavelength and the tube high voltage: 1 min ~ U (1) Page 1 of 9

This Duane-Hunt relationship can be sufficiently explained by examining some basic quantum mechanical considerations: As the wavelength and the frequency for any electromagnetic radiation are related in the manner c (2) c = 2.9979 x 10 8 m s -1 : velocity of light the minimum wavelength min respectively a maximum energy corresponds to a maximum frequency max E max h max (3) h: Planck s constant of the emitted x-ray quanta. However, an x-ray quantum attains maximum energy at precisely the moment in which it acquires the total kinetic energy E e U (4) e = 1.6022 x 10-19 C : elementary charge of an electron decelerated in the anode. It thus follows that max e h U (5) respectively min h e c 1 U (6) Equation (6) corresponds to Duane and Hunt s law. The proportionality factor A h c (7) e can be used to determine Planck s constant h when the quantities c and e are known. Page 2 of 9

A goniometer with NaCl crystal and a Geiger-Müller counter tube in the Bragg configuration together comprise the spectrometer in this experiment. The crystal and counter tube are pivoted with respect to the incident x-ray beam in 2 coupling (cf. Fig. 2). 1 collimator 2 monocrystal 3 counter tube 3 2 1 2 Fig. 2 Schematic diagram of diffraction of x-rays at a monocrystal and 2 coupling between counter-tube angle and scattering angle (glancing angle). In accordance with Bragg s law of reflection, the scattering angle in the first order of diffraction corresponds to the wavelength 2 d sin (8) d = 282.01 pm : lattice plane spacing of NaCl Page 3 of 9

Safety Notes The x-ray apparatus fulfills all regulations governing an x-ray apparatus and fully protected device for instructional use and is type approved for school use in Germany (NW 807/97 Rö). The built-in protection and screening measures reduce the local dose rate outside of the x-ray apparatus to less than 1 Sv/h, a value which is on the order of magnitude of the natural background radiation. Before putting the x-ray apparatus into operation inspect it for damage and to make sure that the high voltage is shut off when the sliding doors are opened (see Instruction Sheet for x-ray apparatus). Keep the x-ray apparatus secure from access by unauthorized persons. Do not allow the anode of the x-ray tube Mo to overheat. When switching on the x-ray apparatus, check to make sure that the ventilator in the tube chamber is turning. The goniometer is positioned solely by electric stepper motors. Do not block the target arm and sensor arm of the goniometer and do not use force to move them. Page 4 of 9

SETUP Setup of Bragg configuration: Fig. 3 Experiment setup in Bragg configuration. Fig. 3 shows some important details of the experiment setup. To setup the experiment, proceed as follows: Mount the collimator in the collimator mount (a)(note the guide groove). Attach the goniometer to guide rods (d) so that the distance s 1 between the slit diaphragm of the collimator and the target arm is approx. 5 cm. Connect ribbon cable (c) for controlling the goniometer. Remove the protective cap of the end-window counter. Place the endwindow counter in sensor seat (e) and connect the counter tube cable to the socket marked GM TUBE. By moving the sensor holder (b), set the distance s 2 between the target arm and the slit diaphragm of the sensor receptor to approx. 6 cm. Mount the target holder (f) with target stage. Page 5 of 9

Loosen knurled screw (g). Place the NaCl crystal flat on the target stage. Carefully raise the target stage with crystal all the way to the stop and gently tighten the knurled screw (prevent skewing of the crystal by applying a slight pressure). Notes: NaCl crystals are hygroscopic and extremely fragile. Store the crystlas in a dry place; avoid mechanical stresses on the crystal; handle the crystal by the short faces only. If counting rate is too low, you can reduce the distance s 2 between the target and the sensor somewhat. However, the distance should not be too small, as otherwise the angular resolution of the goniometer is no longer sufficient. CARRYING OUT THE EXPERIMENT Start the software X-ray Apparatus. Check to make sure that the apparatus is connected correctly, and clear any existing measurement data using the F4 key. Select Crystal calibration in the software settings [F5]; set the correct Bragg crystal and the correct anode material and select Start search. After completing the calibration, the angular deviation must be saved in the goniometer by hitting Adopt. Set the tube high voltage U = 35 kv, the emission current I = 1.00 ma, the measuring time per angular step t = 10 s and the angular step width = 0.1. Press the COUPLED key to activate 2 coupling of target and sensor and set the lower limit, min, of the target angle to 2.5 and upper limit, max, to 6.0. Start measurement and data transfer to the PC by pressing [F9] or the SCAN key. Page 6 of 9

Additionally record measurement series with the tube high voltages U = 34 kv, 32 kv, 30 kv, 28 kv, 26 kv, 24 kv and 22 kv; to save measuring time, use the parameters from table 1 for each series. To show the wavelength-dependency, open the Settings dialog with the F5 key and enter the lattice plane spacing for NaCl. When you have finished measuring, save the measurement series under an appropriate name by pressing the F2 key. U/kV I/mA t/s min /grd max /grd /grd 35 1.00 10 2.5 6.0 0.1 34 1.00 10 2.5 6.0 0.1 32 1.00 10 2.5 6.0 0.1 30 1.00 10 3.2 6.0 0.1 28 1.00 20 3.8 6.0 0.1 26 1.00 20 4.5 6.2 0.1 24 1.00 30 5.0 6.2 0.1 22 1.00 30 5.2 6.2 0.1 Table 1 Recommended parameters for recording the measurement series. Page 7 of 9

EVALUATION Determining the limit wavelength min as a function of the tube high voltage U: For each recorded diffraction spectrum (see Fig. 4): In the diagram, click the right mouse button to access the evaluation functions of the software X-ray Apparatus and select the command Best-fit Straight Line. Mark the curve range to which you want to fit a straight line to determine the limit wavelength min using the left mouse button. Save the evaluations under a suitable name by pressing F2. Fig. 4 Sections from the diffraction spectra of x-radiation for the tube high voltages U = 22, 24, 26, 28, 30, 32, 34 and 35 kv (from right to left) with best-fit straight line for determining the limit. Page 8 of 9

Confirming the Duane-Hunt relation and determining Planck s constant For further evaluation of the limit wavelengths min determined in this experiment, click on the register Planck. Position the pointer over the diagram, click the right mouse button, fit a straight line through the origin to the curve min = f(1/u) and read the slope A from the bottom left corner of the evaluation window (see Fig. 5). Determine Planck s constant. Fig. 5 Evaluation of the data min = f(1/u) for confirming the Duane-Hunt relationship and determining Planck s constant. Revised 6 th January 2014 Page 9 of 9