CYHCS-RC2S Split Core Hall Effect DC Current Sensor

Similar documents
DC Current Sensor CYCT04-xnL20

Current Transducer CTSR 1-P = 1A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER HAB 60-S/SP5

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet

AUTOMOTIVE CURRENT SENSOR HC6H300-S

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S

High Performance Current Transducer ITL 900-T = A

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DR 200-S

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

DC CURRENT SENSOR DC VOLTAGE SENSOR

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

Transducer for Measurement Bridges SCM90, SIGS15

AUTOMOTIVE CURRENT TRANSDUCER DHAB S/15

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124

Current Sensor: ACS750xCA-100

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

ULTRASTAB I U Precision

ULTRASTAB IHF Precision Current Transducer

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Closed Loop Current Sensors

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

Linear Current Sensor with differential outputs

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

PowerAmp Design. PowerAmp Design PAD112 HIGH VOLTAGE OPERATIONAL AMPLIFIER

DC Current Transducers 4XCT-100-C-HP User s Manual All Rights Reserved CAEN ELS s.r.l. Rev. 1.0 February 2017

= 1000 V. Voltage transducer DVC 1000-P V P N

Interactive Catalog Replaces Catalog Pages

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

V1000-ISO ± 1000V PRECISION HIGH BANDWIDTH ISOLATED VOLTAGE TRANSDUCER

PowerAmp Design. PowerAmp Design PAD117A RAIL TO RAIL OPERATIONAL AMPLIFIER

Voltage transducer DVL 50

MCTS II Multi Channel Current Transducer System. Installation Manual

PRECISION CURRENT TRANSDUCERS. DC Current Transducers CT-100 CT-150. User s Manual. All Rights Reserved CAEN ELS d.o.o. Rev. 1.

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

SPECIFICATION Item no.: T60404-N4646-X764

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

DRG-SC Series Signal Conditioners

Typical Application VCC IP+ ACS755 GND C F 3 R F

DS10000ULFS-10V/10kA

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

400 (±2,5 V/ V/ ,3% V4A

Sendyne SFP200MOD Precision Current and Voltage Measurement Module

PowerAmp Design. PowerAmp Design PAD183 COMPACT HIGH VOLTAGE OP AMP

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI

Transcription:

Current Sensors CYHCS-RC2S Split Core Hall Effect DC Current Sensor This Hall Effect current sensor can be used for measurement of DC and AC current, pulsed currents etc. The output of the transducer reflects the real wave of the current carrying conductor. Product Characteristics Excellent accuracy Very good linearity Light in weight Less power consumption Window structure Electrically isolating the output of the transducer from the current carrying conductor No insertion loss Current overload capability Electrical Data/Input Applications Frequency conversion timing equipments Various power supply Uninterruptible power supplies (UPS) Electric welding machines Numerical controlled machine tools Electrolyzing and electroplating equipments Electric powered locomotive Microcomputer monitoring Electric power network monitoring Primary Nominal Primary Current Measuring Aperture Part number RMS Current I r (A) Range I p (A) at Vcc=12V Diameter (mm) 3 6 21 CYHCS-RC2S-3A-XC 5 1 21 CYHCS-RC2S-5A-XC 1 2 21 CYHCS-RC2S-1A-XC 2 4 21 CYHCS-RC2S-2A-XC 3 6 21 CYHCS-RC2S-3A-XC 4 8 21 CYHCS-RC2S-4A-XC 5 9 21 CYHCS-RC2S-5A-XC 6 9 21 CYHCS-RC2S-6A-XC Supply Voltage: X=3, V cc = +12VDC 5%, ; X=4, V cc =+15VDC 5%; X=5, V cc =+24VDC 5%, (Connector: Molex connector C=M; Phoenix Connector: C=P) Current Consumption RMS Voltage for 2.5kV AC isolation test, 5/6Hz, 1min, I c < 25mA V is <1mA Output Voltage at I r, T A =25 C: V out = V oe ±2V Output Impedance: R out < 15 Load Resistor: R L > 1k Accuracy at I r, T A =25 C (without offset), X <1.% Linearity from to I r, T A =25 C, E L <1.% FS Electric Offset Voltage, T A =25 C, V oe =5.V±1.% Magnetic Offset Voltage (I r ) V om <15mV Thermal Drift of Offset Voltage, V ot <±1.mV/ C Thermal Drift (-1 C to 5 C), T.C. <.1% / C Response Time at 9% of I P (f=1k Hz) t r < 7μs Frequency Bandwidth (-3dB), f b = -2 khz Mean Time Between Failures (MTBF): 5k - 1k hours Ambient Operating Temperature, Ambient Storage Temperature, T A = -25 C ~ +85 C T S =-4 C ~ +1 C Products constantly update. All specifications are subject to change without notice. For more information on this product, please contact: PC&S, Inc. at +1 (8) 523-9194 or +1 (973) 448-94 www.pc-s.com

Relation between Input Current and Output Voltage Take the sensor CYHCS-RC2S-1A-3 as sample, the relation between the input current and output voltage is shown in the table 1, Fig.1 and Fig. 2 Table 1. Relation between the input current and output voltage Input current (A) -2-15 -1-5 5 1 15 2 Output voltage (V) 1. 2. 3. 4. 5. 6. 7. 8. 9. 1 9 8 Output Voltage (V) 7 6 5 4 3 2 1 Offset 5V DC -25-2 -15-1 -5 5 1 15 2 25 Input current (A) Fig. 1 Relation between the input current (DC) and output voltage (DC) Input current (A) 25 2 15 1 5-5 -1-15 -2-25 Output Voltage (V) 1 9 8 7 6 5 4 3 2 1 Offset 5V DC Time Time Fig. 2 Relation between the input current (AC) and output voltage (AC)

PIN Definition and Dimensions Current direction OFS GIN 7.5 1(+): Vcc 2(G): NC 3(O): Output 4(G): GND OFS: Offset Adjustment GIN: Gain Adjustment Connection Vcc: +12V, +15V, +24V NC CYHCS- RC2S Output GND Vo V Notes: 1. Connect the terminals of power source, outputs respectively and correctly, never make wrong connection. 2. Two potentiometers can be adjusted, only if necessary, by turning slowly to the required accuracy with a small screwdriver. 3. The best accuracy can be achieved when the window is fully filled with bus-bar (current carrying conductor). 4. The in-phase output can be obtained when the direction of current of current carrying conductor is the same as the direction of arrow marked on the transducer

DIN Rail Adapter CY-DRA88 The DIN Rail Adapter CY-DRA88 is designed for mounting the sensor on 35mm DIN Rail. It has the size 7 x 24 x 23mm. The height from bottom to mounting surface is 14.8mm. 14.8 35.5

Mounting of Sensors Sensor with Molex Connector (The distance between the bottom und the middle of hole is 54.8mm) Sensor with Phoenix Connector (The distance between the bottom und the middle of hole is 54.8mm) and www.pc-s.com For more information and certifications, please contact: Panel Components & Systems, Inc. n Phone: (8) 523-9194 n info@pc-s.com Main Office: Stanhope, NJ Phone: (973) 448-94 DSCYHCSRC2S, Rev, 215