National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

Similar documents
Alternating Current Power

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Article 225: Outside Branch Circuits And Feeders

NEC 2014 Code Changes

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Electrical Occupations

Electrical Wiring: Commercial, Seventh Canadian Edition

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

User's Guide. AC Circuit Load Tester. Model CT70

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

EASQ ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) MARKING SCHEDULE. SECTION 1 Marks Reference Marking notes Qu 1 A 10 MΩ (2 marks)

Boat Dock Exposure Voltage Mitigation

MES 2008 Errata Student Manual

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Wisconsin Contractors Institute Continuing Education

American Electrical Institute

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

Grounding and Bonding of Service Equipment

Licensed Electricians Practical Assessment (LEP)

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

EFCOG BEST PRACTICE # 211. Best Practice Title: Managing Hazards of Multiwire Branch Circuits Installed Before the 2008 NEC

FINAL - EST Electrical Service Technician Answer Schedule

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

Licensed Electricians Practical Assessment (LEP)

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

2. Determine the number of Modules/Microinverters required. (1134 modules is 2 less than 250 KW but works well with max comm.

ET 40 - Electrician Theory Examination Marking Schedule

ECET Fall 2017 Name: _ Lab Assignment #01

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only* 2013 CEC

PROVINCE.OF BRITISH COLUMBIA. ORDER OF THE LIEUTENANfelOVERNOR IN COUNCIL

SureTest Model ST-1THD & ST-1THDC Instructions

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

Installation Manual DOC R1 Date: 05/27/99. Plug-in Meter Installation Manual

ELECTRICIAN S THEORY EXAMINATION 20 November 2010 QUESTION AND ANSWER BOOKLET

Continued from Part 1 Rules 1 25.

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

Ground Fault Isolation with Loads Fed from Separately Derived Grounded Sources

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only*

Journeyman's Practice Exam

Article 250 Grounding & Bonding

B. Manufacturers: Square-D, G.E. or Westinghosue.

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM. Unit Objectives. Unit Objectives 2/29/2012

FINAL - ER 70 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes

Wiring Methods, Components, and Equipment for General Use -- OSHA Standard

EAS Electrical Appliance Serviceperson Answer Schedule

7. INSPECTION AND TEST PROCEDURES

2014 NEC Changes Part 1

AN EXAMPLE OF A STANDARD ARC FLASH PPE LABELING STRATEGY

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

Frequently Asked Question on Isolated Power Supply(IPS)

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Grounding Recommendations for On Site Power Systems

CHAPTER 2 Wiring and Protection. Article 200 Use and Identification of Grounded Conductors

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

AC Voltage-Current Interface Unit (VCIU) for the Galaxy Millennium Controller With L10 L14, L20 L24, L30 L38, L40 L44, and L57 Interface Units

Article 700: Emergency Systems. 2.! Audible and visual signal devices shall be provided, where practicable to indicate.

Section 6: System Grounding Bill Brown, P.E., Square D Engineering Services

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

high RESISTANCE GROUNDING SYSTEM the power to protect SLEUTH Instruction Manual C-408EM

FINAL - IT 30 ELECTRICAL INSPECTOR EXAMINATION ANSWER SCHEDULE. Question 1 Marks Reference Marking notes. (2 marks) EA 2

Preface...x Chapter 1 Electrical Fundamentals

Grounding and Bonding

BUCK-BOOST TRANSFORMERS

A. Product Description: Stranded conductor insulated wire.

TN, TT & IT Earthing Arrangements

Current Probes. User Manual

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011

Circuit Analyzer MS5908A. Operation S Manual MS5908A TEST. ma VA ms Hz% 12 A 15 A 20 A HOLD ms VA. V Vd Z RCD GFCI

ER 87 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) ESR 27(2) (2 marks) ESR 74A(1AA)

ELPT 1429 RESIDENTIAL WIRING

Chapter 1 Electrical Theory and Part C Series Parallel and Code Questions Multiwire Branch Circuits Unit 1 Electrician s Math

1 Exam Prep NFPA 70: National Electric Code 2011 Tabs and Highlights

Grounding Complications

Ground Fault Location. Turbo Sleuth. Instruction Manual

EPG. by Chris C. Kleronomos

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL

ECET 211 Electric Machines & Controls Lecture 3-1 (Part 1 of 2) Motor Transformers and Distribution Systems

ELECTRICIAN S THEORY EXAMINATION 17 November 2012 QUESTION AND ANSWER BOOKLET

high RESISTANCE GROUNDING SYSTEM the power to protect www. ElectricalPartManuals. com Instruction Manual C-102

BC145 SIGNAL ISOLATOR BOARD

3Ø Short-Circuit Calculations

120 / 240 VAC SINGLE SPLIT PHASE & MULTI-WIRE BRANCH CIRCUITS. Excerpt from G4 InverCharge Series Manual BY: VIJAY SHARMA ENGINEER

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Jake Leahy s Electrical Code Connection. A look at Grounding and Bonding of Electrical Services Article Florida Building Code 5 th Edition

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

Home Electrical Wiring. Types of Receptacles and Wiring them for 120v 15Amp/20Amp

INTRODUCTION...xiii Author s Comments...xiii Exam Preparation...xiii Difficult Concepts...xiv Textbook Errors and Corrections...xv Internet...

CONTINUING EDUC ATION

Wiring of the Main Distribution Panelboard

2017 NEC TABLE OF CONTENTS

CP /240-MC4 User Manual

The Variable Threshold Neutral Isolator (VTNI)

2011 / Circuit Tracer

Freedom HW 1000 Inverter/Charger. Installation Guide

2394 EXAM PAPER. 1. State THREE circumstances that would require a periodic inspection and test to be carried out on an installation

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

Transcription:

1. Two Electrical Technicians are discussing markings that are required for AC wiring. Tech A says that AC conductors must be rated for 600 volts and must have their jackets and individual conductors marked with the voltage, type or style, gauge, and temperature rating of the insulation. Tech B says that AC flexible cords must be rated for 300 volts and only their jackets must be marked with the voltage, type or style, gauge and temperature rating of the insulation. Which Tech is right? a. Tech A b. Tech B c. Both Techs d. Neither Tech 2. The AC Grounding Conductor does not normally carry current, but is a very important part of the AC electrical system. Which of the following statements are true regarding this conductor: a. This conductor is used to connect the metallic non-current carrying parts of AC electrical equipment to the AC grounding bus, engine negative terminal or its bus and to the source ground. b. This conductor may be referred to as the ground conductor. c. This conductor may have a Galvanic Isolator or an Isolation Transformer installed in series. d. All of the above are true statements. 3. The AC ungrounded conductor from the source of power to the main switchboard (not a branch circuit) must have over current protection at the source or within 7 or within 40 if the conductor is sheathed. The circuit breaker that is used for this purpose is rated: a. Not to exceed the maximum current requirements of the load b. For at least 150% of the nominal voltage of the supply circuit c. For no more than the maximum current carrying capacity of the conductor being protected d. For no more than 150% of the ampacity of the conductor if the correct size breaker is not available. 1

4. According to ABYC Standards, the AC grounded (neutral/white) conductor shall: a. not be connected to AC grounding conductor (green) at the dock shore power supply. b. be connected to the AC grounding conductor (green) at the inverter output in the invert mode, generator output, and at the secondary of an isolation or polarization transformer, a procedure called grounding the neutral at the source of power on the boat. c. be connected to the engine negative terminal or its bus. d. never be grounded on board the boat. 5. Each boat equipped with an AC shore power system MUST have: a. A flexible cord that contains the conductors for the power circuit and a grounding conductor which shall be provided. b. A flexible cord terminated with a locking and grounding female type connector to match the boat power inlet. c. A shore power inlet Warning Label installed in a location of frequent service. d. A power inlet installed that is always waterproof.. 6. Consider an isolation transformer and a polarization transformer. Which statement below is correct? a. They are wired differently, but both provide isolation and polarization. b. An isolation transformer provides isolation for the ungrounded, grounded and grounding conductors. c. In order for a polarization transformer to provide isolation, a galvanic isolator must be added in series with the grounding conductor between the shore power inlet and the transformer. d. Both b and c above are correct. 7. AC wiring requirements include which of the following: a. AC conductors shall be bundled, sheathed or kept separate from DC conductors b. All AC current carrying conductors and the grounding conductor shall be contained in the same sheath, bundle or raceway. c. The main AC grounding bus shall be connected to the engine negative terminal or the DC main negative bus on grounded DC systems. d. All of the above are correct. 2

8. When more than one shore power inlet is installed, ABYC recommends that the neutrals (grounded/white conductor) for each system: a. not be connected together on the boat. b. be connected together at a combined neutral bus bar. c. be connected to the AC grounding bus on the boat. d. be connected to the engine negative terminal. 9. AC circuit breakers must be installed that have the following requirements: a. Ampere interrupting capacity based on the installed shore power and Table IV B and be manually reset trip-free type. b. Main breakers must be marked to indicate their function and replacement type, class and rating and other breakers shall have a means to identify their function and location in the system. c. Current rating not exceeding the maximum current carrying capacity of the conductor being protected unless the 150% exception applies for branch circuits. d. All of the above are necessary for AC circuit breakers. 10. Downrating the ampacity (reducing the allowed current carrying capability) of AC conductors to avoid excessive heat build-up is required because of which of the following: a. Bundling of conductors for any distance. b. The grounding conductor is counted when considering the number of conductors that are bundled. c. Bundling of conductors for a distance of 24 or more and the temperature of the compartment in which the conductors are installed (inside or outside the engine room). d. The AC grounding conductor must be one size smaller than the current carrying conductors. 3

11. ABYC E-11 requires the installation of an Equipment Leakage Circuit Interrupter (ELCI) or a Type A Residual Current Device (RCD) on all boats with AC shore power. Which statement below is true? a. These devices block galvanic current above 30 ma and detect the reversal of the ungrounded and grounded conductors which provides protection from in-water shock hazards. b. These devices detect equipment ground fault leakage current greater than 30 ma and disconnect all current carrying conductors from the supply source within 100 milli seconds. c. All RCD devices available for marine use are acceptable for meeting the requirement for ground fault protection for all boats. d. Installation of either of these devices removes the requirement for GFCI breakers in the head, galley, and other wet areas. 12. An Equipment Leakage Circuit Interrupter or a Type A Residual Current Device: a. Shall be installed in addition to or incorporated with the main shore power disconnect breakers or the breakers within 10 of the shore connection, whichever is closer to the shore power connection. b. Shall be installed in a readily accessible location. c. Is not required if an isolation transformer is installed within 10 of the shore power entry or the electrical attachment point of a permanently installed shore cord. d. all of the above are true. 13. The transfer of AC power to a circuit from one source to another shall be made: a. by a means that connects to the new power source before disconnecting from the present power source. b. by a means that disconnects the present source before connecting to the new source in all AC electrical systems utilizing more than one source of power. c. by a means that opens all current carrying conductors, including neutrals, before closing the alternate source circuit, to maintain isolation of power sources, unless the system uses equipment meeting the requirements of ABYC A- 32 Power Conversion Equipment and Systems. d. by a means that opens all current carrying conductors when an isolation or polarization transformer is installed. 4

14. Marine electrical tech A says that non-metallic conductor support is ok for all AC conductors since they are not usually installed over engines. Marine electrical tech B says that all AC cables from the shore power inlet to the main shore power breaker (or to the main breaker installed within 10 of the shore inlet) must be installed in conduit or supported by metal straps or clamps. Which tech is right? a. Tech A b. Tech B c. Both are right d. Neither is right 15. Two marine electrical technicians are having a discussion. Tech A says that reverse polarity indicating devices providing a continuous audible or visible signal shall be installed on all boats with 120 volt shore power systems to respond to the reversal of the ungrounded and grounded conductors. Tech B says that reverse polarity indicating devices providing a continuous audible or visible signal shall be installed in 120 volt shore power systems to respond to the reversal of the ungrounded and grounded conductors if the polarity of the system must be maintained, or branch circuit breakers are single pole, or no transformer is installed. Which Tech is correct? a. Tech A b. Tech B c. Both techs d. Neither tech 16. AC panel boards have several markings and required equipment under certain conditions. Which statement below is correct regarding AC panel boards? a. A system voltmeter or ammeter is required on an AC panel board. b. Single phase and 3 phase system panel boards have the same requirements. c. The face of an AC system panel board must be permanently marked with the system voltage and either VAC or system frequency. d. A system voltmeter, of any type, shall be installed if the panelboard is permanently connected to an electric motor, or a generator or an inverter or inverter/charger. 5

17. Which statement below is correct regarding the function or installation of a galvanic isolator? a. A galvanic isolator is a device installed in series with the grounded conductor to block AC fault current below 1 amp and pass low voltage galvanic current b. A galvanic isolator is a device installed in series with the AC grounding conductor to eliminate galvanic corrosion remove the requirement for a warning label at the shore power connection. c. A galvanic isolator is a device installed in series with the AC grounding conductor to block low voltage DC galvanic current and permit the passage of AC current normally associated with the AC grounding conductor. d. A galvanic isolator is a device installed between the grounded conductor and the grounding conductor to reduce low voltage galvanic current and reduce galvanic corrosion. 18. AC electrical equipment and appliances have specific mechanical and electrical installation requirements. Which statement below best describes these requirements? a. Some AC appliances designed for permanent installation shall be securely mounted to the boat s structure. b. Current carrying parts of the AC electrical equipment shall be designed so that the current carrying parts of the device are effectively insulated from all exposed electrically conductive parts. c. All exposed electrically conductive, non-current carrying parts of fixed AC electrical equipment and appliances, shall be connected to the grounded conductor. d. If an AC appliance has a neutral to ground bonding strap, it must not be removed. 19. Two 10 gauge triplex AC conductors, each containing a green, black and white wire are rated at 105 degrees C that are bundled together inside the diesel engine compartment for a distance of 3, must have the ampacity of each current carrying conductor down rated from the maximum current allowed without any bundling of conductors in the same environment: a. From 60 amps to 36 amps b. From 51 amps to 30.6 amps c. From 51 amps to 42 amps d. From 60 amps to 30.6 amps 6

20. What size circuit breaker should be used to protect an AC branch circuit that has 24 current carrying 14 gauge, 105 degree C, conductors bundled together for a distance of 15 outside the engine compartment of a gasoline powered boat? a. 20 amp b. 15 amp c. 150 % of 17.5 amps d. 25 amps 7