Jake Leahy s Electrical Code Connection. A look at Grounding and Bonding of Electrical Services Article Florida Building Code 5 th Edition

Similar documents
2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

Article 250 Grounding & Bonding

American Electrical Institute

Electrical Wiring: Commercial, Seventh Canadian Edition

Wisconsin Contractors Institute Continuing Education

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

CONTINUING EDUC ATION

Grounding and Bonding of Service Equipment

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Continued from Part 1 Rules 1 25.

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING

ECET Fall 2017 Name: _ Lab Assignment #01

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

1 Exam Prep NFPA 70: National Electric Code 2011 Tabs and Highlights

2017 NEC TABLE OF CONTENTS

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL

Ground Fault Location. Turbo Sleuth. Instruction Manual

Journeyman's Practice Exam

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only*

POWER SERVICE DETAILS

high RESISTANCE GROUNDING SYSTEM the power to protect www. ElectricalPartManuals. com Instruction Manual C-102

Grounding and Bonding

Article 225: Outside Branch Circuits And Feeders

A. Product Description: Stranded conductor insulated wire.

Bulletin Filming in Minnesota

Short-Circuit Current Calculations

NEC 2014 Code Changes

Grounding Systems and Their Implementation By: Charles Atkinson Canadian Broadcasting Corporation Toronto, Canada

2014 NEC Changes Part 1

high RESISTANCE GROUNDING SYSTEM the power to protect SLEUTH Instruction Manual C-408EM

Module 2 Unit 6, 7, 8

Wiring of the Main Distribution Panelboard

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

Grounding Recommendations for On Site Power Systems

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

Note: The let-through of the protective device must be equal to or less than the short-circuit current rating of the component being protected.

Page Electric Utility Service Specifications

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

BX /2 Solid Ac/BX Aluminum Cable

SECTION DISTRIBUTION SWITCHBOARDS

Department of Labor and Industry Electrical Licensing

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

6B.6 Substation Grounding

Short Circuit Current Calculations

Licensed Electricians Practical Assessment (LEP)

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

SECTION TRANSFORMERS

Box Fill. We have learned how to fill or NOT overfill a conduit. We must also determine how to fill boxes and conduit bodies.

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings

SECTION DISTRIBUTION SWITCHBOARDS

Article 700: Emergency Systems. 2.! Audible and visual signal devices shall be provided, where practicable to indicate.

6. Internal lightning protection

The Importance of the Neutral-Grounding Resistor. Presented by: Jeff Glenney, P.Eng. and Don Selkirk, E.I.T.

LEARNING GUIDE G-3 INSTALL GROUNDING AND BONDING

3Ø Short-Circuit Calculations

EPG. by Chris C. Kleronomos

Continuing Education, For UDC Electrical Inspectors, Commercial Electrical Inspectors, Master Electricians and Journeyman Electricians.

Section 6: System Grounding Bill Brown, P.E., Square D Engineering Services

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

Grounding and Lightning arrestors

We have 3 ways to help you prepare

Copper Sheathed Cable Sheath Currents

NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit

INTELLIMETER REGISTER

Grounding and Bonding Requirements for Network Facilities

This document covers common questions concerning the design of an effectively grounded system.

ATT-TP Grounding and Bonding Requirements for Network Facilities

RADIO AND TELEVISION SATELLITE EQUIPMENT

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

Zinc Cable & Conduit Connectors For Armored Cable, Flexible Metal Conduit & Metal Clad Cable

MEMORANDUM. National Fire Protection Association

ECET 211 Electric Machines & Controls Lecture 3-1 (Part 1 of 2) Motor Transformers and Distribution Systems

Code Check Electrical is a field guide to common code issues in residential

Table K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

SECTION PANELBOARDS

Mechanical Grounding Connectors

Licensed Electricians Practical Assessment (LEP)

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Chapter 6. WIRING SYSTEMS Safe Electrical Design

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

Course 11 Distribution Transformer Applications Instructor: David R. Smith, PE Due: April 24, 2017 (EV), April 25, 2017 (LC)

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

Upgrading Your Electrical Distribution System To Resistance Grounding

Three Phase Transformers

PC IEEE Guide for Grounding of Instrument Transformer Secondary Circuits and Cases

SECTION INTERCOMMUNICATIONS SYSTEMS. A. Section Includes: Manually switched intercommunications systems with the following components:

The Variable Threshold Neutral Isolator (VTNI)

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

Electrical IP Red Seal Practice Exam

tings fi t fl ex/mc/ac

NEW OR UPGRADED ELECTRICAL SERVICE

ECE 528 Understanding Power Quality

ER 87 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) ESR 27(2) (2 marks) ESR 74A(1AA)

Transcription:

Jake Leahy s Electrical Code Connection A look at Grounding and Bonding of Electrical Services Article 250 2014 Florida Building Code 5 th Edition

Wiring Integrity. Completed wiring installations shall be free from short circuits, ground faults, or any connections to ground other than as required or permitted elsewhere in this Code. The Code limits the connections to the grounded conductor (neutral) on the load side of the service disconnecting means. It cannot be bonded or connected to the equipment ground to limit its intended path and purpose.

Effective Ground-Fault Current Path. An intentionally constructed, low-impedance electrically conductive path designed and intended to carry current under ground-fault conditions from the point of a ground fault on a wiring system to the electrical supply source and that facilitates the operation of the overcurrent protective device or ground-fault detectors on high-impedance grounded systems.

Ground-Fault Current Path. An electrically conductive path from the point of a ground fault on a wiring system through normally non current-carrying conductors, equipment, or the earth to the electrical supply source. Ground Fault. An unintentional, electrically conducting connection between an ungrounded conductor of an electrical circuit and the normally non current-carrying conductors, metallic enclosures, metallic raceways, metallic equipment, or earth.

IN: Examples of ground-fault current paths could consist of any combination of equipment grounding conductors, metallic raceways, metallic cable sheaths, electrical equipment, and any other electrically conductive material such as metal water and gas piping, steel framing members, stucco mesh, metal ducting, reinforcing steel, shields of communications cables, and the earth itself.

(5)Effective Ground-Fault Current Path. Electrical equipment and wiring and other electrically conductive material likely to become energized shall be installed in a manner that creates a low-impedance circuit facilitating the operation of the overcurrent device. It shall be capable of safely carrying the maximum groundfault current likely to be imposed on it from any point on the wiring system where a ground fault may occur to the electrical supply source. The earth shall not be considered as an effective ground-fault current path.

The grounded conductor shall not be connected to normally non current carrying metal parts of equipment, to equipment grounding conductor(s), or be reconnected to ground on the load side of the service disconnecting means except as otherwise permitted in article 250.

Grounded Conductor Brought to Service Equipment. Where an ac system operating at less than 1000 volts is grounded at any point, the grounded conductor(s) shall be routed with the ungrounded conductors to each service disconnecting means and shall be connected to each disconnecting means grounded conductor(s) terminal or bus. A main bonding jumper shall connect the grounded conductor(s) to each service disconnecting means enclosure. The grounded conductor(s) shall be installed in accordance with 250.24(C)(1) through (C)(3).

(1) Sizing for a Single Raceway. The grounded conductor shall not be smaller than the required grounding electrode conductor specified in Table 250.66 but shall not be required to be larger than the largest ungrounded service-entrance phase conductor. In addition, for sets of ungrounded service-entrance conductors larger than 1100 kcmil copper or 1750 kcmil aluminum, the grounded conductor shall not be smaller than 12-1/2 percent of the circular mil area of the largest set of serviceentrance ungrounded conductor(s).

(2) Parallel Conductors in Two or More Raceways. If the ungrounded service-entrance conductors are installed in parallel in to or more raceways, the grounded conductor shall also be installed in parallel. The size of the grounded conductor in each raceway shall be based on the total circular mil area of the parallel ungrounded conductor in the raceway, as indicated in 250.24(C)(1), but not smaller than 1/0 AWG. (3) Delta-Connected Service. The grounded conductor of a 3-phase, 3-wire delta service shall have an ampacity not less than that of the ungrounded conductors.

Number of Neutrals

How many neutrals?

Ungrounded

Even FPL follows the rules

A 2000 ampere service has 8 #250 kcmil THHW cu conductors to make up each phase conductor. What size grounded (neutral) conductor is needed for the service? 250 Kcmil THHW Cu. = 255 amperes (310.16) 255 amperes X 8 = 2040 amperes (240.4 (C) ) 8 X 250 Kcmil = 2000 Kcmil (total for each phase) 2000 X.125 = 250 Kcmil for the grounded (neutral) conductor

A 400 ampere service has a #500 Kcmil THHW Cu. Conductor for each phase conductor. What is the minimum size grounded (neutral) conductor that can be run to the service? Per 250.24 (C) (1) Table 250.66 shows the size of the grounded conductor when the phase conductor is smaller than a #1750 Kcmil Cu. conductor. #500 Kcmil Cu. phase conductor = 1/0 Cu. Grounded conductor Per 250.24 (C) (3) for Delta three wire three phase services the grounded conductor shall be the same size as the phase conductors and is only required to be brought to the first means of disconnect

Bonding Jumper, Main. Article 100. The connection between the grounded circuit conductor and the equipment grounding conductor at the service. Main bonding jumpers and system bonding jumpers shall not be smaller than the sizes shown in Table 250.66. Where the supply conductors are larger than 1100 kcmil copper or 1750 kcmil aluminum, the bonding jumper shall have an area that is not less than 12-1/2 percent of the area of the largest phase conductor.

250.28(D)(2) Where a service consists of more than a single enclosure as permitted in 230.71(A), the main bonding jumper for each enclosure shall be sized in accordance with 250.28(D)(1) based on the largest ungrounded service conductor serving that enclosure.

Main Bonding Jumper

NEUTRAL IMPROPERLY SIZED Delta Service

(A) Bonding of Equipment for Services. The normally non current-carrying metal parts of equipment indicated in 250.92(A)(1) and (A)(2) shall be bonded together. (1) All raceways, cable trays, cablebus framework, auxiliary gutters, or service cable armor or sheath that enclose, contain, or support service conductors, except as permitted in 250.80.

(2) All enclosures containing service conductors, including meter fittings, boxes, or the like, interposed in the service raceway or armor. Course Note! These are the unprotected conductors from the utility, generator, or transformer. Unprotected meaning non-fused

(B) Bonding jumpers meeting the other requirements of this article shall be used around impaired connections, such as reducing washers or oversized, concentric, or eccentric knockouts. Standard locknuts or bushings shall not be the only means for the bonding required by this section but shall be permitted to be installed to make a mechanical connection of the raceway(s). Electrical continuity at service equipment, service raceways, and service conductor enclosures shall be ensured by one of the following methods:

(1) Bonding equipment to the grounded service conductor in a manner provided in 250.8 (2) Connections utilizing threaded couplings or threaded hubs on enclosures if made up wrench tight (3) Threadless couplings and connectors if made up tight for metal raceways and metal-clad cables (4) Other listed devices, such as bonding-type locknuts, bushings, or bushings with bonding jumpers

Meter Hub

Bonding Bushing

Bonding Screw